Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Introduction As required by FCC KDB Publication 680106 D01 wireless charging devices require RF exposure evaluation. For A4WP charging devices it is typically necessary to have FCC oversight through the pre-Approval Guidance (PAG) procedures (formerly referenced to as Permit But Ask or PBA) Intel has performed the evaluation for the charging coil and associated electronics at maximum charging current of 0.68 Amps (rms) and has followed FCC's Pre-Approval Guidance procedures. FCC the approved the RF exposure evaluation of this combination of coil and maximum charging current and the approval for a 20cm separation distance can be leveraged to support this specific device's characteristics and form factor and is only applicable to identical devices as defined in 47 CFR 2.908. During the certification process for the Bluetooth transceiver (and possibly Part18 wireless charging transmitter) the Certification body should request a copy of the KDB enquiry. The enquiry shall ne filed as confidential document in accordance with FCC procedures and should be accompanied by a copy of this document and user information document containing the required information. This KDB enquiry still requires that the final device be tested for compliance with the requirements of Part 18 for Consumer ISM devices and FCC Part 15.247 for the Bluetooth transmitter. If the wireless charging feature is integrated into another device the FCC rules and approvals requirements applicable to the other device need to be followed and a separate KDB enquiry shall be submitted to the FCC to confirm the appropriate RF exposure evaluation distance and device configurations. No. 669, Ruey Kuang Road Neihu Taipei, Taiwan, R.O.C. Tel: 883-2-2798-9008 Fax: 886-2-8798-1565 A1TX User Manual Radiation Exposure Statement: To comply with RF exposure requirements the charging mat must be used on a table top or similar and provide a minimum separation distance of 20cm from the charging surface to users. The information required for devices that have been approval using FCC's certification procedures for Part 18 and for the Bluetootj transceiver will need the following information (refer to FCC CFR Title 47 Part 18.213,: Model: A1TX / Wireless Power Charger (A4WP) This device complies with Part 15 and Part 18 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Modifications mode to this device, unless expressly approved by PRIMAX ELECTRONICS LTD.. may void the user's rights to operate this equipment. No. 669, Ruey Kuang Road Neihu Taipei, Taiwan, R.O.C. Tel: 883-2-2798-9008 Fax: 886-2-8798-1565 ● Package Contents: Check your package for the follow items: 1. A1TX PTU 2. 12V Adapter 3. User Manual ● Status display: There are 3 LED on the left side, Please ref to next chap “LED Mode”, it will define the LED message. ● LED Mode: There are three LED will show system status. System Status Green Blue Red Standby Constant light OFF OFF Charging OFF Constant light OFF Fail OFF OFF Constant light No. 669, Ruey Kuang Road Neihu Taipei, Taiwan, R.O.C. Tel: 883-2-2798-9008 Fax: 886-2-8798-1565 ● Charge Area: For best user experience, please keep the PRU coil in the best charge area. Note: The best performance in the center, and there are difference performance of four corners. All discuss of efficiency in this document is mean center area. Top View No. 669, Ruey Kuang Road Neihu Taipei, Taiwan, R.O.C. Tel: 883-2-2798-9008 Fax: 886-2-8798-1565 ● Warning: Do not put metal on the charge path. 1. Vertically, please keep any metal out of top and bottom side. It’ll impact the charge efficiency. 4. Do not close to Pacemaker Artificial pacemaker. 2. Horizontal, around the charge plate, please keep 10 cm distances with metal at least. 3. For some magnetic device, it’ll be disturbed. (ex: magnetic measuring instruments, touch panel...). Please keep an appropriate distance to use. No. 669, Ruey Kuang Road Neihu Taipei, Taiwan, R.O.C. Tel: 883-2-2798-9008 Fax: 886-2-8798-1565 Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and o…
Text truncated - open the document above for the full version.
No. 669, Ruey Kuang Road Neihu Taipei, Taiwan, R.O.C. Tel: 883-2-2798-9008 Fax: 886-2-8798-1565 Date: 2015-11-06 Model number: A1TX FCC ID: EMJCA1TX Declaration Letter We, PRIMAX ELECTRONICS LTD. hereby declare that the said product have identical design as described in KDB386456 submitted by Intel, which built-in with Resonator Coil (Intel regular type RES-14-0006) and Intel Chip CC2541SOC and its RF characteristics together with form factor are same as the product mentioned in the KDB. If you should have any question(s) regarding this declaration, please don’t hesitate to contact us. Very truly yours, ------------------------------------------------------------------- C.T. Huang Compliance Dept. / Director Phone: 886-2-2798-9008 ext.1710 Fax: 886-2-8797-1565 Email: [email protected]
No. 669, Ruey Kuang Road Neihu Taipei, Taiwan, R.O.C. Tel: 883-2-2798-9008 Fax: 886-2-8798-1565 Date: November 6, 2015 FCC ID: EMJCA1TX To the attention of Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: Schematics Block Diagram The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely yours, ------------------------------------------------------------------- C.T. Huang Compliance Dept. / Director Phone: 886-2-2798-9008 ext.1710 Fax: 886-2-8797-1565 Email: [email protected]
No. 669, Ruey Kuang Road Neihu Taipei, Taiwan, R.O.C. Tel: 883-2-2798-9008 Fax: 886-2-8798-1565 Date: 2015-11-06 FCC ID: EMJCA1TX To the attention of Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we request short-term confidential treatment for the following information until 180 days after the Grant Date of Equipment Authorization in order to ensure sensitive business information remains confidential until the actual marketing of the device: External photos Test Setup photos User’s manual Internal Photos Sincerely yours, ------------------------------------------------------------------- C.T. Huang Compliance Dept. / Director Phone: 886-2-2798-9008 ext.1710 Fax: 886-2-8797-1565 Email: [email protected]
No. 669, Ruey Kuang Road Neihu Taipei, Taiwan, R.O.C. Tel: 883-2-2798-9008 Fax: 886-2-8798-1565 Date: 2015-11-06 FCC ID: EMJCA1TX A U T H O R I Z A T I O N L E T T E R To whom it may concern: We, the undersigned, hereby authorize Amanda Wu / Senior Specialist of Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (BV CPS Taoyuan) of Taiwan to act on our behalf in all manners relating to FCC application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Amanda Wu / Senior Specialist of BV CPS Taoyuan on our behalf shall have the same effect as acts of our own. If you have any questions regarding the authorization, please don’t hesitate to contact us. Sincerely yours, ------------------------------------------------------------------- C.T. Huang Compliance Dept. / Director Phone: 886-2-2798-9008 ext.1710 Fax: 886-2-8797-1565 Email: [email protected]
Page 1 CONSTRUCTION PHOTOS OF EUT Page 2 Page 3
Page 4 Page 5
FCC ID: EMJCA1TX Report No.: RF150526D03 Operational Description This device is a Wireless Power Charger (A4WP). The transmitter of the EUT is powered by 12Vdc from Adapter. The antenna is Chip antenna without antenna connector. For more detailed instruction, please take a look at the user’s manual.
1 Briggs, Mark From: Se nt: To : Subject: [email protected] Friday, October 2, 2015 9:47 AM Briggs, Mark Response to Inquiry to FCC (Tracking Number 386456) The l inked image cannot be displayed. The file may have been moved, renamed, or deleted. Verify that the link points to the correct file and location. FCC Home | Search | RSS | Updates | E-Filing | Initiatives | Consumers | Find People The linked image cannot be displayed. The file may have been moved, renamed, or deleted. Verify that the link points to the correct file and location. Office of Engineering and Technology Inqui ry on 07/23/2015 : Inquiry: Dear OET staff, This inquiry is being submitted for a wireless charging coil following the A4WP wireless charging standard. The inquiry will be for a nominal 5W charging device with a rectangular, multi-turn coil measuring approximately 9cm x 14cm. The A4WP standard uses a charging frequency of 6.78 MHz that is loosely inductively coupled (resonant charging. Load\power management and control is performed via a Bluetooth Low Energy link with Bluetooth transceivers located on both the transmit unit and the receive (client) unit. Specific device details are included in an attachment to this KDB. As the measured electric and magnetic fields exceed the reference levels in FCC Part 2 we will need to perform evaluation of rf exposure using computational modelling as was done for FCC ID 2AB8ZND3. Included in the attachment are proposed rf exposure evaluation distances for the assessment and we would appreciate confirmation that these are appropriate prior to us submitting the data (anticipated time- frame would be week ending August 8). 2 It is anticipated that this coil will be used by different manufacturers in their versions of the same charging pad. Where possible we would like to use approval of the rf exposure evaluation via this KDB inquiry for these other devices to enable our customers that use the exact same coil architecture and design at the same (or lower) maximum current used in our modelling. To do this we would provide very specific information to restrict re-use of the KDB approval to only those designs that use the exact same coil design and operation at the same or lower current for desktop charging applications. Are there any other aspects we should address to allow the KDB to cover this coil design versus a specific charging mat? If a phone call would be useful to clarify any aspect of this enquiry please do not hesitate to call. FCC response on 08/06/2015 Before consideration of test data being applied across different transmitter implementations (a policy which is currently most akin to modular approvals), assessment procedures for the EUT should be reviewed. Although KDB Publication 680106 D01 indicates that WPT type devices used for typical desktop applications should have their exposure analysis conducted at 10cm, if an EUT can be shown to be designed for use at farther distances (or such a distances can be assured via appropriate marking), testing at such a distance may be authorized (consistent with 47 CFR 2.1091). Other items which will be taken into consideration are size, form factor, output power, and/or associated receivers. Please clarify if it is desirable to show compliance at a distance consistent with mobile applications (i.e. 20cm) and, if so, please provide documentation demonstrating that this EUT would be designed for such conditions. Incorporation of user instructions, labeling, and a compliance information statement (consistent with 2.1077(c)) may also be used to justify such testing. ---Reply from Customer on 08/17/2015--- OET Staff, Thank you forthe response. You asked: Please clarify if it is desirable to showcompliance at a distance consistent with mobile applications (i.e. 20cm) and,if so, please provide documentation demonstrating that this EUT would bedesigned for such conditions. Incorporation of user instructions, labeling, anda compliance information statement (consistent with 2.1077(c)) may also be usedto justify such testing. The intendeduse for chargers using this coil design will be for table- top us e, consistentwith mobile applications supporting a minimum separation distance of 20cm. The5W charging capability is for handset charging and not for charging largerdevices, such as tablets or laptops. As such we have prepared a guidancedocument, submitted as an attachment to this KDB enquiry, to be provided toODMs and OEMs who intend to use this specific coil design in their endproducts. This document contains the restrictions on leveraging any 3 OETapproval through this KDB enquiry, includes the language that needs to beprovided to end users and installers related to minimum separation distances,and describes the approval procedures related to rf exposure. Note thatthe coil (aka resonator) has been certified with A4WP and leverage of the A4WPcertification to support final device certification is also limited to use ofthis specific coil design at the same maximum coil current we are describing inthis KDB. As the finaldevice will require certification for the Bluetooth transmitter (possibly forPart 18 if the manufacturer decides not to follow these DoC procedures) the TCBshould ask for an rf exposure exhibit that addresses compliance of the completeproduct (not just the Bluetooth transmitter). The applicant will need toprovide this KDB enquiry information, including the associated test report andthe Intel installation guide, so that the TCB can confirm compliance with therequirements for product intended use. We hope the guidance in thisenquiry and associated attachments are sufficiently clear that the TCB would beallowed to issue the certification grants without additional FCC oversight. If,however, the TCB does not consider that the device meets the implementationrequirements described in this, or any other related enquiry, then they shouldbe following the PAG procedures. A test reportcontaining the RF field values at 20cm, measu…
Text truncated - open the document above for the full version.
Report No.: SA150526D03 Page No. 1 / 9 Report Format Version: 6.1.1 RF Exposure Report Report No.: SA150526D03 FCC ID: EMJCA1TX Test Model: A1TX Received Date: May 26, 2015 Test Date: Oct. 14, 2015 Issued Date: Oct. 20, 2015 Applicant: PRIMAX ELECTRONICS LTD. Address: No. 669, Ruey Kuang Road, Neihu, Taipei, Taiwan, R.O.C. Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan (R.O.C.) This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: SA150526D03 Page No. 2 / 9 Report Format Version: 6.1.1 Table of Contents Release Control Record .................................................................................................................................. 3 1 Certificate of Conformity ...................................................................................................................... 4 2 RF Exposure .......................................................................................................................................... 5 2.1 Test Setup ........................................................................................................................................... 5 2.2 Test Instruments .................................................................................................................................. 5 2.3 Limits For Maximum Permissible Exposure (MPE) ............................................................................. 6 2.4 Test Point Description ......................................................................................................................... 6 3 Calculation Result Of Maximum Conducted Power .......................................................................... 7 4 Photographs of the Test Configuration .............................................................................................. 9 Report No.: SA150526D03 Page No. 3 / 9 Report Format Version: 6.1.1 Release Control Record Issue No. Description Date Issued SA150526D03 Original release. Oct. 20, 2015 Report No.: SA150526D03 Page No. 4 / 9 Report Format Version: 6.1.1 1 Certificate of Conformity Product: Wireless Power Changer(A4WP) Brand: PRIMAX Test Model: A1TX Sample Status: Engineering sample Applicant: PRIMAX ELECTRONICS LTD. Test Date: Oct. 14, 2015 Standards: FCC Part 1 (Section 1.1307(b), 1.1310) The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. Prepared by : , Date:Oct. 20, 2015 Annie Chang / Senior Specialist Approved by : , Date:Oct. 20, 2015 Rex Lai / Assistant Manager Report No.: SA150526D03 Page No. 5 / 9 Report Format Version: 6.1.1 2 RF Exposure 2.1 Test Setup Note: Measurements should be made from all sides and the top of the primary/client pair, with the 20 cm measured from the center of the probe(s) to the edge of the device. 2.2 Test Instruments Description Brand Model No. Frequency Range Calibrated Date Calibrated Until Broadband Field Meter NARDA NBM-550 - Feb. 28, 2014 Feb. 27, 2016 Magnetic Field Meter NARDA ELT-400 1 – 400kHz Feb. 26, 2014 Feb. 25, 2016 Magnetic Probe NARDA HF-3061 300kHz – 30MHz Feb. 26, 2014 Feb. 25, 2016 Magnetic Probe NARDA HF-0191 27 – 1000MHz Feb. 28, 2014 Feb. 27, 2016 Broadband Field Meter NARDA NBM-550 - Feb. 28, 2014 Feb. 27, 2016 Electric Field Meter COMBINOVA EFM 200 5Hz – 400kHz Oct. 14, 2015 Oct. 13, 2016 E-Field Probe NARDA EF-0391 100kHz – 3GHz Mar. 6, 2014 Mar. 5, 2016 E-Field Probe NARDA EF-6091 100MHz – 60GHz Feb. 28, 2014 Feb. 27, 2016 NOTE: 1. The calibration interval of the above test instruments is 12/24 months and the calibrations are traceable to NML/ROC and NIST/USA. 2. The test was performed in Chia Pau RF Chamber EUT Field Probe 20 cm Report No.: SA150526D03 Page No. 6 / 9 Report Format Version: 6.1.1 2.3 Limits For Maximum Permissible Exposure (MPE) § 1.1310 The criteria listed in table 1 shall be used to evaluate the environmental impact of human exposure to radiofrequency(RF) radiation as specified in § 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of § 2.1093 of this chapter. 2.4 Test Point Description Bottom Top Right Left Z-axis (Above) Report No.: SA150526D03 Page No. 7 / 9 Report Format Version: 6.…
Text truncated - open the document above for the full version.
Report No.: SA150526D03-1 Page No. 1 / 6 Report Format Version: 6.1.1 RF Exposure Report Report No.: SA150526D03-1 FCC ID: EMJCA1TX Test Model: A1TX Received Date: May 26, 2015 Test Date: May 26 ~ 29, 2015 Issued Date: Oct. 20, 2015 Applicant: PRIMAX ELECTRONICS LTD. Address: No. 669, Ruey Kuang Road, Neihu, Taipei, Taiwan, R.O.C. Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan ( R.O.C. ) This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: SA150526D03-1 Page No. 2 / 6 Report Format Version: 6.1.1 Table of Contents Release Control Record .................................................................................................................................. 3 1 Certificate of Conformity ...................................................................................................................... 4 2 Evaluation Result .................................................................................................................................. 5 3 Sar Test Exclusion Thresholds ........................................................................................................... 6 4 Conclusion ............................................................................................................................................ 6 Report No.: SA150526D03-1 Page No. 3 / 6 Report Format Version: 6.1.1 Release Control Record Issue No. Description Date Issued SA150526D03-1 Original release Oct. 20, 2015 Report No.: SA150526D03-1 Page No. 4 / 6 Report Format Version: 6.1.1 1 Certificate of Conformity Product: Wireless Power Charger (A4WP) Brand: PRIMAX Test Model: A1TX Sample Status: Engineering Sample Applicant: PRIMAX ELECTRONICS LTD. Test Date: May 26 ~ 29, 2015 Standards: FCC Part 2 (Section 2.1093) KDB 447498 D03 IEEE C95.1 The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. Prepared by : , Date:Oct. 20, 2015 Annie Chang / Senior Specialist Approved by : , Date:Oct. 20, 2015 Rex Lai / Assistant Manager Report No.: SA150526D03-1 Page No. 5 / 6 Report Format Version: 6.1.1 2 Evaluation Result Following FCC KDB 447498 D01 “General SAR test exclusion guidance” The corresponding SAR Exclusion Threshold condition, listed below: 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz . Power and distance are rounded to the nearest mW and mm before calculation . The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is determined according to the following: a) [Threshold at 50 mm in step 1) + (test separation distance - 50mm)·( f(MHz)/150)] mW, at 100MHz to 1500 MHz b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤ 6 GHz 3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion. a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm. b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test separation distances ≤ 50 mm. c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any test results to be acceptable. Report No.: SA150526D03-1 Page No. 6 / 6 Report Format Version: 6.1.1 3 SAR Test Exclusion Thresholds Maximum measured transmitter power: Frequency (GHz) Max. Power (mW) Min. test separation distance (mm) SAR test exclusion calculation value (NOTE 2) 1-g SAR t…
Text truncated - open the document above for the full version.
Report No.: RF150526D03 Page No. 1 / 33 Report Format Version: 6.1.1 FCC Test Report Report No.: RF150526D03 FCC ID: EMJCA1TX Test Model: A1TX Received Date: May 26, 2015 Test Date: May 26 ~ 29, 2015 Issued Date: Oct. 20, 2015 Applicant: PRIMAX ELECTRONICS LTD. Address: No. 669, Ruey Kuang Road, Neihu, Taipei, Taiwan, R.O.C. Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan (R.O.C.) This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF150526D03 Page No. 2 / 33 Report Format Versio…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.00 mW |
Wireless Headset
Equipment Class
DTS - Digital Transmission Systemwegear MW1 Creator Mouse
Equipment Class
DTS - Digital Transmission Systemwegear MW1 2.4G Dongle
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Dongle
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Level Bridge
Equipment Class
DTS - Digital Transmission System