Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
squeezin g both sides of the door. Connectin g the wirel ess dongl e 12 + - + - on the Chr omebox. NOTE: The pairing between the Chr omebox and the remote contr ol is done automatically 3 Legend Selects itmes on the screen Opens and closes all app pages - Hangouts Meet page - During Meetin gs Mutes/Unmutes the microphone Press/hold to enter blu e number and symbols Enter s space Del etes previous char acter Press/hold to enter char acter s in uppercase Reduces volume Increases volume Usin g the wirel ess remote contr ol Ends the meetin g CAUTION: Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used Batteries According to the Instructions. Remote Model GPJ100, Dongle Model GPJ110 Direct current To indicate on the rating plate that the equipment is suitable for direct current only; to identify relevant terminals. For use only with UL Listed I.T.E. computer. Pour utilisation uniquement avec un ordinateur I.T.E. répertorié Federal Communications Commission Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: *Reorient or relocate the receiving antenna. *Increase the separation between the equipment and receiver. *Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. *Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. Changes or modification not expressly approved by the grantee of this device could void the user's authority to operate the equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Innovation, Science and Economic Development (ISED) Statement for Canada This device complies with Innovation, Science and Economic Development Canada (ISED) licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2 ) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'ISED applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. CAN ICES-3 (B)/NMB-3(B) Este produto está homologado pela ANATEL, de acordo com os procedimentos regulamentados pela Resolução n°. 242/2000 e atende aos requisitos técnicos aplicados. Este equipamento não tem direito à proteção contra interferência prejudicial e não pode causar interferência em sistemas devidamente autorizados. Para maiores informações, consulte o site da ANATEL – www.anatel.gov.br B VCCI-B CIDF15000026 8X8 mm include no. 9X17 mm Complies with IMDA Standards DA104808 Do not throw the devise in municipal waste. This Product has been design to enable proper reuse of part and recycling, This symbol of the crossed out wheeled bin indicates that the product (electrical, electronic equipment, and mercury-containing button cell battery) should not be placed in municipal waste. Check local technical support services for product recycling. need Google check information Dispose batteries properly in the nearest recycle staytion accroding to manufacturer’s instruction. need Google check information 5X5 cm XXXX-XX-XXXX 5 mm high logo Each lanuage of WEEE information need Google check information Declaration of Conformity Radio frequency bands and maximum power levels RadioTechnology : Wireless 2.4GHz Maximum Transmit Power EIRP (mW) : 10mW Hereby, Google LLC declares that the radio equipment type GPJ100 and GPJ110 are in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: provide link to the website
No. 669, Ruey Kuang Road Neihu Taipei, Taiwan, R.O.C. Tel: 886-2-2798-9008 Fax: 886-2-8798-1565 Date: January 13, 2020 FCC ID: EMJDGPJ110 To the attention of Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: Block Diagram Schematics Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely yours, ------------------------------------------------------------------- C.T. Huang Compliance Dept. / Director Phone: 886-2-2798-9008 Fax: 886-2-8797-1565 Email: [email protected]
No. 669, Ruey Kuang Road Neihu Taipei, Taiwan, R.O.C. Tel: 886-2-2798-9008 Fax: 886-2-8798-1565 Date: 2020-03-05 FCC ID: EMJDGPJ110 To the attention of Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we request short-term confidential treatment for the following information until 180 days after the Grant Date in order to ensure sensitive business information remains confidential until the actual marketing of the device: External photos Test Setup photos User’s manual Internal Photos Sincerely yours, ------------------------------------------------------------------- C.T. Huang Compliance Dept. / Director Phone: 886-2-2798-9008 Fax: 886-2-8797-1565 Email: [email protected]
No. 669, Ruey Kuang Road Neihu Taipei, Taiwan, R.O.C. Tel: 883-2-2798-9008 Fax: 886-2-8798-1565 Date: 2020-01-13 FCC ID: EMJDGPJ110 A U T H O R I Z A T I O N L E T T E R To whom it may concern: We, the undersigned, hereby authorize Andrea Hsia / Supervisor of Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (BV CPS Taoyuan) of Taiwan to act on our behalf in all manners relating to FCC application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Andrea Hsia / Supervisor of BV CPS Taoyuan on our behalf shall have the same effect as acts of our own. If you have any questions regarding the authorization, please don’t hesitate to contact us. Sincerely yours, ------------------------------------------------------------------- C.T. Huang Compliance Dept. / Director Phone: 886-2-2798-9008 Fax: 886-2-8797-1565 Email: [email protected]
No. 669, Ruey Kuang Road Neihu Taipei, Taiwan, R.O.C. Tel: 883-2-2798-9008 Fax: 886-2-8798-1565 Date: 2020-03-12 Re: Supersede request for FCC ID: EMJDGPJ110; Granted on 03/9/2020 To Whom It May Concern: We regret to inform you that due to marketing information concern, we have submitted the wrong label & label location exhibit to the filing. To prevent misunderstanding to the public, we would like to request the FCC to supersede the exhibit described as label & label location. If you have any questions, feel free to contact us. Thank you. Sincerely yours, ------------------------------------------------------------------- C.T. Huang Compliance Dept. / Director Phone: 886-2-2798-9008 ext.1710 Fax: 886-2-8797-1565 Email: [email protected]
Reference No.: 191104D13-ExtPho Page 1 / 3 CONSTRUCTION PHOTOS OF EUT Reference No.: 191104D13-ExtPho Page 2 / 3 Reference No.: 191104D13-ExtPho Page 3 / 3
FCC ID: EMJDGPJ110
Reference No.: 191104D13-IntPho Page 1 / 2 CONSTRUCTION PHOTOS OF EUT Reference No.: 191104D13-IntPho Page 2 / 2
Report No.: SA191104D13 Page No. 1 / 6 Report Format Version: 6.1.1 RF Exposure Report Report No.: SA191104D13 FCC ID: EMJDGPJ110 Test Model: GPJ110 Received Date: Nov. 4, 2019 Test Date: Nov. 5 to 13, 2019 Issued Date: Dec. 5, 2019 Applicant: PRIMAX ELECTRONICS LTD. Address: No. 669, Ruey Kuang Road, Neihu, Taipei, Taiwan, R.O.C. Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan FCC Registration / Designation Number: 198487 / TW2021 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: SA191104D13 Page No. 2 / 6 Report Format Version: 6.1.1 Table of Contents Release Control Record .................................................................................................................................... 3 1 Certificate of Conformity ......................................................................................................................... 4 2 Evaluation Result .................................................................................................................................... 5 3 SAR Test Exclusion Thresholds .............................................................................................................. 6 4 Conclusion .............................................................................................................................................. 6 Report No.: SA191104D13 Page No. 3 / 6 Report Format Version: 6.1.1 Release Control Record Issue No. Description Date Issued SA191104D13 Original release. Dec. 5, 2019 Report No.: SA191104D13 Page No. 4 / 6 Report Format Version: 6.1.1 1 Certificate of Conformity Product: Dongle Brand: Google Test Model: GPJ110 Sample Status: Engineering sample Applicant: PRIMAX ELECTRONICS LTD. Test Date: Nov. 5 to 13, 2019 Standards: FCC Part 2 (Section 2.1093) KDB 447498 D01 General RF Exposure Guidance v06 IEEE C95.1-1992 The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s RF characteristics under the conditions specified in this report. Prepared by : , Date:Dec. 5, 2019 Annie Chang / Senior Specialist Approved by : , Date:Dec. 5, 2019 Rex Lai / Associate Technical Manager Report No.: SA191104D13 Page No. 5 / 6 Report Format Version: 6.1.1 2 Evaluation Result Following FCC KDB 447498 D01 “General SAR test exclusion guidance” The corresponding SAR Exclusion Threshold condition, listed below: 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ꞏ[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz. Power and distance are rounded to the nearest mW and mm before calculation . The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is determined according to the following: a) [Threshold at 50 mm in step 1) + (test separation distance - 50mm)ꞏ( f(MHz)/150)] mW, at 100MHz to 1500 MHz b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)ꞏ10] mW at > 1500 MHz and ≤ 6 GHz 3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion. a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm. b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test separation distances ≤ 50 mm. c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any test results to be acceptable. Report No.: SA191104D13 Page No. 6 / 6 Report Format Version: 6.1.1 3 SAR Test Exclusion Thresholds Maximum measured transmitter power: Function Frequency (GHz) Max. Rad…
Text truncated - open the document above for the full version.
Report No.: RF191104D13 Page No. 1 / 29 Report Format Version: 6.1.1 FCC Test Report Report No.: RF191104D13 FCC ID: EMJDGPJ110 Test Model: GPJ110 Received Date: Nov. 4, 2019 Test Date: Nov. 5 to 13, 2019 Issued Date: Dec. 5, 2019 Applicant: PRIMAX ELECTRONICS LTD. Address: No. 669, Ruey Kuang Road, Neihu, Taipei, Taiwan, R.O.C. Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan FCC Registration / Designation Number: 198487 / TW2021 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF191104D13 Page No. 2 / 29 Report Format Version: 6.1.1 Table of Contents Release Control Record .................................................................................................................................. 3 1 Certificate of Conformity ...................................................................................................................... 4 2 Summary of Test Results ..................................................................................................................... 5 2.1 Measurement Uncertainty ................................................................................................................... 5 2.2 Modification Record ............................................................................................................................ 5 3 General Information .............................................................................................................................. 6 3.1 General Description of EUT ................................................................................................................ 6 3.2 Description of Test Modes ................................................................................................................... 7 3.2.1 Test Mode Applicability and Tested Channel Detail ............................................................................. 8 3.3 Description of Support Units ............................................................................................................. 10 3.3.1 Configuration of System under Test .................................................................................................. 10 3.4 General Description of Applied Standards ........................................................................................ 10 4 Test Types and Results ....................................................................................................................... 11 4.1 Radiated Emission and Bandedge Measurement .............................................................................. 11 4.1.1 Limits of Radiated Emission and Bandedge Measurement ............................................................... 11 4.1.2 Test Instruments ................................................................................................................................ 12 4.1.3 Test Procedures ................................................................................................................................. 13 4.1.4 Deviation from Test Standard ............................................................................................................ 13 4.1.5 Test Setup .......................................................................................................................................... 14 4.1.6 EUT Operating Conditions ................................................................................................................. 15 4.1.7 Test Results ....................................................................................................................................... 16 4.2 Channel Bandwidth ........................................................................................................................... 26 4.2.1 Test Setup .......................................................................................................................................... 26 4.2.2 Test Instruments ................................................................................................................................ 26 4.2.3 Test Procedure .................................................................................................................................. 26 4.2.4 Deviation from Test Standard ............................................................................................................ 26 4.2.5 EUT Operating Condition .............................................................…
Text truncated - open the document above for the full version.
Reference No.: RF191104D13 Page No. 1 / 3 PHOTOGRAPHS OF THE TEST CONFIGURATION CONDUCTED EMISSION TEST Reference No.: RF191104D13 Page No. 2 / 3 RADIATED EMISSION TEST <Frequency Range below 1GHz> Reference No.: RF191104D13 Page No. 3 / 3 RADIATED EMISSION TEST <Frequency Range above 1GHz>
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |
Wireless Headset
Equipment Class
DTS - Digital Transmission Systemwegear MW1 Creator Mouse
Equipment Class
DTS - Digital Transmission Systemwegear MW1 2.4G Dongle
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Dongle
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Level Bridge
Equipment Class
DTS - Digital Transmission System