Custom Products OPERATIONS MANUAL Rechargeable ITE (In-The-Ear) Rechargeable ITC (In-The-Canal) Rechargeable Smartphone-Compatible and Universal Connectivity Table of ContentsTable of Contents Overview ITE Overview � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4 ITC Overview � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 5 Charger Overview � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 6 Preparation Charging Your Hearing Aids � � � � � � � � � � � � � � � � � � � � � � � 8 Charger On-Board Battery LEDs � � � � � � � � � � � � � � � � � � � 10 Insertion and Removal � � � � � � � � � � � � � � � � � � � � � � � � � � � 11 Operation Power On & Off � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 13 User Controls � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 13 Volume Control� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 14 Volume Control Indicators � � � � � � � � � � � � � � � � � � � � � � � � 16 Battery Indicators � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 16 Memory Change � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 17 Mute � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 17 Multiflex Tinnitus Level Control � � � � � � � � � � � � � � � � � � � � 18 Directional Settings � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 18 Telephone Use � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 18 Multiflex Tinnitus Technology � � � � � � � � � � � � � � � � � � � � � � � � 22 Fall Alert Introduction � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 24 Auto Alert � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 24 Manual Alert � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 25 Alert Cancellation � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 25 Contacts � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 25 Auto Alert Sensitivity � � � � � � � � � � � � � � � � � � � � � � � � � � � � 26 Indicators � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 27 Adjustment Pairing with an iOS Device � � � � � � � � � � � � � � � � � � � � � � � 28 Mobile Phone Use � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 30 Pairing with an Android Device � � � � � � � � � � � � � � � � � � � � 30 Accessories Accessories � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 31 Hearing Aid Care Hearing Aid Care � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 32 Charger Care � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 33 Service and Repair � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 37 Troubleshooting Guide � � � � � � � � � � � � � � � � � � � � � � � � � � 38 Tips for Better Communication � � � � � � � � � � � � � � � � � � � � � � � 41 Regulatory Information Safety Information � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 43 FDA Information� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 44 FCC Information� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 49 Hearing Aid Starkey Hearing Technologies Charger FPOFPO My hearing aid is a/an: ITE (In-The-Ear) see page 4� ITC (In-The-Canal) see page 5� 4 | ITE Overview ITC Overview | 5 Features, Controls and Identification Your hearing aid controls include: Features, Controls and Identification Your hearing aid controls include: 1. 2. 3. 4. 5. Microphone Vent (optional) Sound outlet (receiver) and wax protection Multifunction button (optional) Rotary volume control (optional) 1. 2. 3. 4. 5. Microphone Vent (optional) Sound outlet (receiver) and wax protection Multifunction button (optional) Rotary volume control (optional) Your hearing aid can be identified by: Your hearing aid can be identified by: 6. Location of serial number: RED is for right ear, BLUE is for left ear 6. Location of serial number: RED is for right ear, BLUE is for left ear 1 3 Dual Control (Optional) Dual Control (Optional) 2 4 2 4 1 3 6 = Multifunction Button (Optional) Multifunction Button (Optional) 6 3 3 5 6 5 Rotary Volume Control (Optional) Rotary Volume Control (Optional) 0 Charger Overview | 7 6 | Charger Overview Features, Controls and Identification 1� Cleaning brush 2� Charging posts 3� Hearing Aid Charging LEDs 4� On-board battery LEDs 5� MicroUSB port 4 5 3 2 1 6 7 FPO Preparation | 9 8 | Preparation Charging Your Hearing Aids • Place your hearing aids in the charger with the faceplates facing down on the charging posts • Your hearing aids will turn off automatically and begin to charge • Note: The LEDs corresponding to each hearing aid: – Glowing Green = Charging – Solid Green = Fully Charged * – Blinking Red = Fault State – Remove from charger, wait until LED turns off and re-insert aids� If Fault State continues, call your hearing professional� * If you are charging without cord, the LEDs will turn off when charged, to save battery. • Charging occurs with the lid open or closed • Your hearing aids will be completely charged in under 3 ½ hours • It is safe to keep them in the charger after they are fully charged and any time that you are not wearing them • If you will not be wearing your hearing aids for an extended period of time (i�e�, weeks) remove the plug from the charger and the hearing aids from the charging ports� You will need to manually power the hearing aids off by pressing the push button for three seconds� You may store them in the reservoir • Your hearing aids will automatically power on when removed from the charger • When charging without the charger cord the LEDs will turn off when the hearing aids are fully charged • To refresh LEDs when the charger is not plugged in, remove a hearing aid from the charging port for three seconds and then replace it in the charger (refresh lasts 10 seconds only – then LEDs will turn off again) FPO P…
Text truncated - open the document above for the full version.
Livio Custom Rechargeable Right Hearing Aid External photos External side 1 External side 2 External side/top External bottom
48 | Regulatory Information Regulatory Information | 49 discontinue use of the device and seek a consultation with a medical, audiology or other hearing professional. As with any device, misuse of the tinnitus therapy device could present some potentially harmful effects. Care should be taken to prevent the unauthorized use and to keep the device out of the reach of children and pets. CAUTION: If set to the maximum output level and worn for periods of time exceeding the following recommendations, your exposure to sound energy has the potential to exceed noise exposure limits. You should not use your hearing device for more than sixteen (16) hours a day if your device is set at the maximum output level, nor should you use your device if your hearing professional has set the device at levels that exceed your comfort level. The Starkey Hearing Technologies Charger has been tested to, and has passed, the following emissions and immunity tests: • IEC 60601-1-2 radiated and conducted emissions requirements for a Group 1 Class B device as stated in CISPR 11. • Harmonic distortion and voltage fluctuations affecting the power input source as stated in Table 2 of IEC 60601-1-2. • RF radiated immunity at a field level of 10 V/m between 80 MHz and 2.7 GHz as well as higher field levels from communications devices as stated in Table 9 of IEC 60601-1-2. • Immunity to power frequency magnetic fields at a field level of 30 A/m. • Immunity to ESD levels of +/- 8 kV conducted discharge and +/- 15 kV air discharge. • Immunity to Electrical fast transients on the power input at a level of +/- 2 kV at a 100 Hz repetition rate. • Immunity to Surges on the power input of +/- 1 kV line to line. • Immunity to conducted disturbances induced by RF fields on the power input as stated in Table 6 of IEC 60601-1-2. • Immunity to voltage dips and interruptions on the power input as stated in Table 6 of IEC 60601-1-2. WIRELESS NOTICES FCC ID: EOA-24LIVIOITEL (left), EOA-24LIVIOITER (right) IC: 6903A-24LIVIOITEL(left), Livio ITEL, Via ITEL, AGXsliv ITEL, Esentia ITEL, Livio AI ITEL, Via AI ITEL, AGXsliv AI ITEL, Esentia AI ITEL, Livio Edge AI ITEL, Via Edge AI ITEL, AGXsliv Edge AI ITEL, Esentia Edge AI ITEL, Livio ITCL, Via ITCL, AGXsliv ITCL, Esentia ITCL, Livio AI ITCL, Via AI ITCL, AGXsliv AI ITCL, Esentia AI ITCL, Livio Edge AI ITCL, Via Edge AI ITCL, AGXsliv Edge AI ITCL, Esentia Edge AI ITCL IC: 6903A-24LIVIOITER(right), Livio ITER, Via ITER, AGXsliv ITER, Esentia ITER, Livio AI ITER, Via AI ITER, AGXsliv AI ITER, Esentia AI ITER, Livio Edge AI ITER, Via Edge AI ITER, AGXsliv Edge AI ITER, Esentia Edge AI ITER, Livio ITCR, Via ITCR, AGXsliv ITCR, Esentia ITCR, Livio AI ITCR, Via AI ITCR, AGXsliv AI ITCR, Esentia AI ITCR, Livio Edge AI ITCR, Via Edge AI ITCR, AGXsliv Edge AI ITCR, Esentia Edge AI ITCR Important Notice for Prospective Sound Generator Users Good health practice requires that a person with tinnitus have a medical evaluation by a licensed physician (preferably a physician who specializes in diseases of the ear) before using a sound generator. Licensed physicians who specialize in diseases of the ear are often referred to as otolaryngologists, otologists or otorhinolaryngologists.. The purpose of a medical evaluation is to assure that all medically treatable conditions that may affect tinnitus are identified and treated before the sound generator instrument is used. TINNITUS TECHNICAL DATA Multiflex Tinnitus Technology Maximum Output = 87 dB SPL (typical) when measured in a 2cc coupler per ANSI S3..22 or IEC 60118-7. WIRELESS TECHNICAL DESCRIPTION Your hearing aids contain a radio transceiver utilizing Bluetooth® Low Energy wireless technology operating in the 2.4-2.4835 GHz frequency band with a maximum effective radiated power of -4 dBm using GFSK transmission modulation. The receiver section of the radio has a bandwidth of 1.5 MHz. This hearing aid model has been tested to, and has passed, the following emissions and immunity tests: • IEC 60601-1-2 radiated emissions requirements for a Group 1 Class B device as stated in CISPR 11 • RF radiated immunity at a field level of 10 V/m between 80 MHz and 2.7 GHz as well as higher field levels from communications devices as stated in Table 9 of IEC 60601-1-2 • Immunity to power frequency magnetic fields at a field level of 30 A/m • Immunity to ESD levels of +/- 8 kV conducted discharge and +/- 15 kV air discharge FCC NOTICE This device complies with part 15 of the FCC rules and with ISED Canada’s license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. Cet appareil est conforme à la partie 15 des règlements de la FCC ainsi qu’aux cahiers des charges sur les normes radioélectriques relativement aux appareils exempts de licence d’ISDE Canada. Son fonctionnement est assujetti aux deux conditions suivantes : (1) cet appareil ne doit pas causer d’interférence nuisible, et (2) cet appareil doit accepter toute interférence reçue, y compris celles pouvant générer un fonctionnement indésirable. Remarque : Le fabricant n’est responsable d’aucune interférence radiophonique ou télévisuelle qui pourrait se produire si des modifications non autorisées sont effectuées sur cet équipement. De telles modifications risquent d’annuler le droit de l’utilisateur à se servir de cet équipement. Hereby, Starkey Hearing Technologies declares that the Custom hearing aid is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. A copy of the Declaration of Conformity can be obtained from the addresses on the following page or f…
Text truncated - open the document above for the full version.
Livio Custom Rechargeable Right Hearing Aid Internal photos Internal side 1 Internal side 2 Internal side 3 Internal top Internal side/ faceplate PCB bottom PCB top
Livio Custom Antenna Description The Bluetooth 2.4 GHz antenna is a PIFA component. The same antenna is used in both the left and right hearing aids. The peak gain of the antenna in the assembled DUT is -2 dBi. Figure 1 2.4 GHz Antenna (scale in cm)
This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. This Report shall not be reproduced, except in full without written approval of the laboratory. EAR-Controlled Data - This document contains technical data whose export and reexport/retransfer is subject to control by the U.S. Department of Commerce under the Export Administration Act and the Export Administration Regulations. The Department of Commerce’s prior written approval may be required for the export or re- export/retransfer of such technical data to any foreign person, foreign entity or foreign organization whether in the United States or abroad. More: https://www.bis.doc.gov/index.php/forms-documents/regulations-docs/14-commerce-country-chart/fileT Starkey Laboratories, Inc. Livio Custom Rechargeable Hearing Aid: Right FCC 2.1093:2020 Bluetooth Low Energy Report # STAK0202.11 NVLAP Lab Code: 200630 CERTIFICATE OF EVALUATION 2018-09-14 Product compliance is the responsibility of the client; therefore, the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. This report reflects only those tests from the referenced standards shown in the certificate of test. It does not include inspection or verification of labels, identification, marking or user information. As indicated in the Statement of Work sent with the quotation, Element’s standard process is to always use the latest published version of the test methods even when earlier versions are cited in the test specification. Issuance of a purchase order was de facto acceptance of this approach. Otherwise, the client would have advised Element in writing of the specific version of the test methods they wanted applied to the subject testing Last Date of Evaluation: Thursday, January 23, 2020 Starkey Laboratories, Inc. EUT: Livio Custom Rechargeable Hearing Aid: Right RF Exposure Evaluation Standards Specification Method FCC 2.1093:2020 FCC 447498 D01 General RF Exposure Guidance v06 Results Method Clause Description Applied Results Comments 4.3.1 SAR Test Exclusion Yes Pass None Deviations From Evaluation Standards None Approved By: Donald Facteau, Process Architect Report No. STAK0202.11EAR-Controlled Data2/9 REVISION HISTORY 2018.07.17 Revision Number Description Date (yyyy-mm-dd) Page Number 00 None Report No. STAK0202.11EAR-Controlled Data3/9 ACCREDITATIONS AND AUTHORIZATIONS 2019.03.08 United States FCC - Designated by the FCC as a Telecommunications Certification Body (TCB). Certification chambers, Open Area Test Sites, and conducted measurement facilities are listed with the FCC. A2LA - Accredited by A2LA to ISO / IEC 17065 as a product certifier. This allows Element to certify transmitters to FCC and IC specifications. NVLAP - Each laboratory is accredited by NVLAP to ISO 17025 Canada ISED - Recognized by Innovation, Science and Economic Development Canada as a Certification Body (CB) and as a CAB for the acceptance of test data. European Union European Commission – Within Element, we have a EU Notified Body validated for the EMCD and RED Directives. Australia/New Zealand ACMA - Recognized by ACMA as a CAB for the acceptance of test data. Korea MSIT / RRA - Recognized by KCC’s RRA as a CAB for the acceptance of test data. Japan VCCI - Associate Member of the VCCI. Conducted and radiated measurement facilities are registered. Taiwan BSMI – Recognized by BSMI as a CAB for the acceptance of test data. NCC - Recognized by NCC as a CAB for the acceptance of test data. Singapore IDA – Recognized by IDA as a CAB for the acceptance of test data. Israel MOC – Recognized by MOC as a CAB for the acceptance of test data. Hong Kong OFCA – Recognized by OFCA as a CAB for the acceptance of test data. Vietnam MIC – Recognized by MIC as a CAB for the acceptance of test data. SCOPE For details on the Scopes of our Accreditations, please visit: https://www.nwemc.com/emc-testing-accreditations Report No. STAK0202.11EAR-Controlled Data4/9 FACILITIES 2019.03.08 California Labs OC01-17 41 Tesla Irvine, CA 92618 (949) 861-8918 Minnesota Labs MN01-10 9349 W Broadway Ave. Brooklyn Park, MN 55445 (612)-638-5136 Oregon Labs EV01-12 6775 NE Evergreen Pkwy #400 Hillsboro, OR 97124 (503) 844-4066 Texas Labs TX01-09 3801 E Plano Pkwy Plano, TX 75074 (469) 304-5255 Washington Labs NC01-05 19201 120 th Ave NE Bothell, WA 98011 (425)984-6600 NVLAP NVLAP Lab Code: 200676-0 NVLAP Lab Code: 200881-0 NVLAP Lab Code: 200630-0 NVLAP Lab Code:201049-0 NVLAP Lab Code: 200629-0 Innovation, Science and Economic Development Canada 2834B-1, 2834B-3 2834E-1, 2834E-3 2834D-1 2834G-1 2834F-1 BSMI SL2-IN-E-1154R SL2-IN-E-1152R SL2-IN-E-1017 SL2-IN-E-1158R SL2-IN-E-1153R VCCI A-0029 A-0109 A-0108 A-0201 A-0110 Recognized Phase I CAB for ISED, ACMA, BSMI, IDA, KCC/RRA, MIC, MOC, NCC, OFCA US0158 US0175 US0017 US0191 US0157 Report No. STAK0202.11EAR-Controlled Data5/9 RF Exposure Condition 2018-07-17 The following RF Exposure conditions were used for the assessment documented in this report: Intended Use Portable Location on Body (if applicable) Head/Torso How is the Device Used The Livio Custom Rechargeable Hearing Aid is body worn, next to the head. Radios Contained in the Same Host Device Bluetooth Low Energy Simultaneous Transmitting Radios None Body Worn Accessories NA Environment General Population/Uncontrolled Exposure Report No. STAK0202.11EAR-Controlled Data6/9 PRODUCT DESCRIPTION 2018-07-17 Client and Equipment Under Evaluation Information Company Name: Starkey Laboratories, Inc. Address: 6600 Washington Ave S City, State, Zip: Eden Prairie, MN 55344-3404 Evaluation Requested By: Bill Mitchell EUT: Livio Custom Rechargeable Hearing Aid: Right Date of Evaluation: Thursday, January 23,…
Text truncated - open the document above for the full version.
This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. This Report shall not be reproduced, except in full without written approval of the laboratory. Starkey Laboratories, Inc. Livio Custom BLE Hearing Aid (Right Ear) FCC 15.247:2020 Bluetooth Low Energy (DTS) Radio Report # STAK0202.3 NVLAP LAB CODE: 200881-0 CERTIFICATE OF TEST 2018-09-14 Product compliance is the responsibility of the client; therefore, the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. This report reflects only those tests from the referenced standards shown in the certificate of test. It does not include inspection or verification of labels, identification, marking or user information. As indicated in the Statement of Work sent with the quotation, Element’s standard process is to always use the latest published version of the test methods even when earlier versions are cited in the test specification. Issuance of a purchase order was de facto acceptance of this approach. Otherwise, the client would have advised Element in writing of the specific version of the test methods they wanted applied to the subject testing. Last Date of Test: January 13, 2020 Starkey Laboratories, Inc. EUT: Livio Custom BLE Hearing Aid (Right Ear) Radio Equipment Testing Standards Specification Method FCC 15.247:2020 ANSI C63.10:2013, KDB 558074 Results Method Clause Test Description Applied Results Comments 6.2 Powerline Conducted Emissions No N/A Not required for a battery powered EUT. 11.12.1, 11.13.2, 6.5, 6.6 Spurious Radiated Emissions Yes Pass 11.6 Duty Cycle Yes N/A 11.8.2 Occupied Bandwidth Yes Pass 11.9.1.1 Output Power Yes Pass 11.9.1.1 Equivalent Isotropic Radiated Power Yes Pass 11.10.2 Power Spectral Density Yes Pass 11.11 Band Edge Compliance Yes Pass 11.11 Spurious Conducted Emissions Yes Pass Deviations From Test Standards None Approved By: Eric Brandon, Department Manager Report No. STAK0202.32/58 REVISION HISTORY 2018.07.17 Revision Number Description Date (yyyy-mm-dd) Page Number 00 None Report No. STAK0202.33/58 ACCREDITATIONS AND AUTHORIZATIONS 2019.03.08 United States FCC - Designated by the FCC as a Telecommunications Certification Body (TCB). Certification chambers, Open Area Test Sites, and conducted measurement facilities are listed with the FCC. A2LA - Accredited by A2LA to ISO / IEC 17065 as a product certifier. This allows Element to certify transmitters to FCC and IC specifications. NVLAP - Each laboratory is accredited by NVLAP to ISO 17025 Canada ISED - Recognized by Innovation, Science and Economic Development Canada as a Certification Body (CB) and as a CAB for the acceptance of test data. European Union European Commission – Within Element, we have a EU Notified Body validated for the EMCD and RED Directives. Australia/New Zealand ACMA - Recognized by ACMA as a CAB for the acceptance of test data. Korea MSIT / RRA - Recognized by KCC’s RRA as a CAB for the acceptance of test data. Japan VCCI - Associate Member of the VCCI. Conducted and radiated measurement facilities are registered. Taiwan BSMI – Recognized by BSMI as a CAB for the acceptance of test data. NCC - Recognized by NCC as a CAB for the acceptance of test data. Singapore IDA – Recognized by IDA as a CAB for the acceptance of test data. Israel MOC – Recognized by MOC as a CAB for the acceptance of test data. Hong Kong OFCA – Recognized by OFCA as a CAB for the acceptance of test data. Vietnam MIC – Recognized by MIC as a CAB for the acceptance of test data. SCOPE For details on the Scopes of our Accreditations, please visit: https://www.nwemc.com/emc-testing-accreditations Report No. STAK0202.34/58 FACILITIES 2019.03.08 California Labs OC01-17 41 Tesla Irvine, CA 92618 (949) 861-8918 Minnesota Labs MN01-10 9349 W Broadway Ave. Brooklyn Park, MN 55445 (612)-638-5136 Oregon Labs EV01-12 6775 NE Evergreen Pkwy #400 Hillsboro, OR 97124 (503) 844-4066 Texas Labs TX01-09 3801 E Plano Pkwy Plano, TX 75074 (469) 304-5255 Washington Labs NC01-05 19201 120 th Ave NE Bothell, WA 98011 (425)984-6600 NVLAP NVLAP Lab Code: 200676-0 NVLAP Lab Code: 200881-0 NVLAP Lab Code: 200630-0 NVLAP Lab Code:201049-0 NVLAP Lab Code: 200629-0 Innovation, Science and Economic Development Canada 2834B-1, 2834B-3 2834E-1, 2834E-3 2834D-1 2834G-1 2834F-1 BSMI SL2-IN-E-1154R SL2-IN-E-1152R SL2-IN-E-1017 SL2-IN-E-1158R SL2-IN-E-1153R VCCI A-0029 A-0109 A-0108 A-0201 A-0110 Recognized Phase I CAB for ISED, ACMA, BSMI, IDA, KCC/RRA, MIC, MOC, NCC, OFCA US0158 US0175 US0017 US0191 US0157 Report No. STAK0202.35/58 MEASUREMENT UNCERTAINTY TMU.2015.07.10 Measurement Uncertainty When a measurement is made, the result will be different from the true or theoretically correct value. The difference is the result of tolerances in the measurement system that cannot be completely eliminated. To the extent that technology allows us, it has been our aim to minimize this error. Measurement uncertainty is a statistical expression of measurement error qualified by a probability distribution. A measurement uncertainty estimation has been performed for each test per our internal quality document QM205.4.6. The estimation is used to compare the measured result with its "true" or theoretically correct value. The expanded measurement uncertainty (K=2) can be found included as part of the applicable test description page. Our measurement data meets or exceeds the measurement uncertainty requirements of the applicable specification; therefore, the test data can be compared directly to the specification limit to determine compliance. The calculations for estimating measurement uncertainty are based upon ETSI TR 100 028 (or CISPR 16-4-2 as applicable), and are available…
Text truncated - open the document above for the full version.
XMit 2019.09.05 MN08 Bench - Right - FCC (2).jpg MN08 Bench - Right - FCC (3).jpg DIRECT CONNECT SPURIOUS RADIATED EMISSIONS photo PSA-ESCI 2019.05.10 photos PSA-ESCI 2019.05.10 SE - Right (1).jpg SE - Right (2).jpg - Right (2) SPURIOUS RADIATED EMISSIONS photo PSA-ESCI 2019.05.10 photos PSA-ESCI 2019.05.10 SE - Right (3).jpg SE - Right (4).jpg - Right (4) SPURIOUS RADIATED EMISSIONS photo PSA-ESCI 2019.05.10 photos PSA-ESCI 2019.05.10 SE 001.jpg
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 700.00 µW |

Starlink Edge TV
Equipment Class
DTS - Digital Transmission System
Edge AI ITE right
Equipment Class
DTS - Digital Transmission System
Edge AI CIC
Equipment Class
DTS - Digital Transmission System
Edge AI mRIC R
Equipment Class
DTS - Digital Transmission System
Edge AI ITE left
Equipment Class
DTS - Digital Transmission System