EPKWMT101TX350MHz ASK Transmitter

Acumen Technologies Ltd
350MHz ASK Transmitter - FCC ID EPKWMT101TX - Acumen Technologies Ltd
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Aug 20, 2002
Application Purpose
Original Equipment
Date of Application
Aug 20, 2002
Equipment Note
350MHz ASK Transmitter
Frequency Range
350.00000000 - 350.00000000
Company
Acumen Technologies Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

โ†—

Block Diagram

โ†—

External Photos

ID Label/Location Info

โ†—

Internal Photos

โ†—

Operational Description

โ†—

Schematics

โ†—

Test Report

โ†—
โ†—
โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Internal Photos

Test Setup FCCID : EPKWMT101TX Internal Photo - 1 Internal Photo - 2 Test Setup FCCID : EPKWMT101TX Internal Photo โ€“ 3 Internal Photo โ€“ 4

Operational Description

Wall Mount Remote Transmitter (WMT101) Principle of Operation The micro-controller (MSM64168-205) on the Remote Transmitter reads the resistance of the temperature sensor (thermistor 203-AT) every 16 second. It then converts the resistance reading into temperature reading and display the temperature on the LCD. When the user presses the on button on the Remote Transmitter, the micro- controller will send a series of on/off code words to turn on/off the RF oscillator (MPSH-10) which in turn will transmit an ASK RF signal to the Remote Receiver. The super-regenerative circuit on the Remote Receiver receives the RF signal from the Remote Transmitter, converts it into code words (CMOS logic level) and feed the received code words to the Decoder IC (HT12D). If the received code words match the setting at the Decoder IC it will turn on or off the output drive (a pair of MOSFETs IRFZ-24) according to the code words it received. All timing on the Remote Transmitter is derived from 32768 Hz Crystal-Oscillator.

Test Report

โ€ข The test results reported in this test report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be said to have been obtained. โ€ข This report shall not be reproduced except in full without prior authorization from Intertek Testing Services Hong Kong Limited. โ€ข For Terms And Conditions of the services, it can be provided upon request. โ€ข The evaluation data of the report will be kept for 3 years from the date of issuance. Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 South East Asia Resources Ltd. Application For Certification (FCC ID: EPKWMT101TX) Transmitter WO# 0207833 DL/Sandy August 16, 2002 INTERTEK TESTING SERVICES FCC ID: EPKWMT101TX i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1:General Description EXHIBIT 2:System Test Configuration EXHIBIT 3:Emission Results EXHIBIT 4:Equipment Photographs EXHIBIT 5:Product Labelling EXHIBIT 6:Technical Specifications EXHIBIT 7:Instruction Manual EXHIBIT 8:Miscellaneous Information INTERTEK TESTING SERVICES FCC ID: EPKWMT101TX ii MEASUREMENT/TECHNICAL REPORT South East Asia Resources Ltd. - MODEL: Wall Mount Transmitter WMT101 FCC ID: EPKWMT101TX August 16, 2002 This report concerns (check one:)Original Grant X Class II Change Equipment Type: Low Power Transmitter (example: computer, printer, modem, etc.) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37?Yes No X If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [12-18-01 Edition] provision. Report prepared by:Derek Leung Intertek Testing Services 2/F., Garment Center, 576, Castle Peak Road, HONG KONG Phone:852-2173-8504 Fax:852-2371-0521 INTERTEK TESTING SERVICES FCC ID: EPKWMT101TX iii Table of Contents 1.0 General Description..................................................................................................................2 1.1 Product Description..............................................................................................................2 1.2 Related Submittal(s) Grants....................................................................................................2 1.3 Test Methodology.................................................................................................................3 1.4 Test Facility.........................................................................................................................3 2.0 System Test Configuration..........................................................................................................5 2.1 Justification..........................................................................................................................5 2.2 EUT Exercising Software.......................................................................................................5 2.3 Special Accessories...............................................................................................................5 2.4 Equipment Modification.........................................................................................................6 2.5 Measurement Uncertainty......................................................................................................6 2.6 Support Equipment List and Description..................................................................................6 3.0 Emission Results.......................................................................................................................8 3.1 Field Strength Calculation.......................................................................................................9 3.2 Radiated Emission Configuration Photograph..........................................................................11 3.3 Radiated Emission Data........................................................................................................12 4.0 Equipment Photographs............................................................................................................15 5.0 Product Labelling....................................................................................................................17 6.0 Technical Specifications...........................................................................................................19 7.0 Instruction Manual..................................................................................................................21 8.0 Miscellaneous Information........................................................................................................23 8.1 Measured Bandwidth...........................................................................................................24 8.2 Discussion of Pulse Desensitization.......................................................................................25 8.3 Calculation of Average Factor...............................................................................................26 8.4 Emissions Test Procedures..................................................................................................27 INTERTEK TESTING SERVICES FCC ID: EPKWMT101TX iv List of attached file Exhibit typeFile Descriptionfilename Test ReportTest Reportreport.pdf Operation DescriptionTechnical Descriptiondescri.pdf Test Setup PhotoRadiated Emissionradiated photos.doc Test ReportBandwidth Plotbw.pdf External PhotoExternal Photoexternal photos.doc Internal PhotoInternal Photointernal photos.doc Block DiagramBlock Diagramblock.pdf SchematicsCircuit Diagramcircuit.pdf ID Label/LocationLabel Artwork and Locationlabel.pdf User ManualUser Manualmanual.pdf Timing DiagramTiming Diagramtiming.pdf INTERTEK TESTING Sโ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

Test Setup FCCID : EPKWMT101TX Radiated -front Radiated - rear

Contact Information

Applicant

KY Sham
[email protected]703-904-0405Fax: 703-904-0218

Technical Contact

Intertek Testing Services Hong Kong Ltd.Derek Leung
[email protected](852)2173-8504

2/F., Garment Centre ยท Kowloon ยท Hong Kong

Non-Technical Contact

Intertek Testing Services Hong Kong Ltd.Derek Leung
[email protected](852)2173-8504

Test Firm

Intertek Testing Services Hong KongBilly Chow
[email protected]852-2173-8528Fax: 852-2371-0914

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231350 MHz - 350 MHz-

Other Applications from Acumen Technologies Ltd

Acumen FDC 504 Tx Only - FCC ID EPK504 - Acumen Technologies Ltd
EPK504

Acumen FDC 504 Tx Only

Dec 02, 2010

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Acumen FDC 502 Tx Only - FCC ID EPK502 - Acumen Technologies Ltd
EPK502

Acumen FDC 502 Tx Only

Dec 02, 2010

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
EON 03/04 - FCC ID EPKEON0304 - Acumen Technologies Ltd
EPKEON0304

EON 03/04

Nov 19, 2007

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Johnson Gas RF Model H Version - FCC ID EPK001105A - Acumen Technologies Ltd
EPK001105A

Johnson Gas RF Model H Version

Oct 23, 2006

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Fireplace Remote Control - FCC ID EPK001106A - Acumen Technologies Ltd
EPK001106A

Fireplace Remote Control

Sep 26, 2006

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter