ADCP-75-192 Issue 1 December 2005 Digivance CXD Multi-Band Distributed Antenna System Operation Manual 1343155 Rev A ADCP-75-192 Issue 1 December 2005 Digivance CXD Multi-Band Distributed Antenna System Operation Manual 1343155 Rev A ADCP-75-192 • Issue 1 • December 2005 • Preface Page ii COPYRIGHT 2005, ADC Telecommunications, Inc. All Rights Reserved Printed in the U.S.A. REVISION HISTORY ISSUE DATE REASON FOR CHANGE Issue 1 12/2005 Original release LIST OF CHANGES The technical changes incorporated into this issue are listed below. SECTION IDENTIFIER DESCRIPTION OF CHANGE - - Original release TRADEMARK INFORMATION ADC and Digivance are registered trademarks of ADC Telecommunications, Inc. DISCLAIMER OF LIABILITY Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. This publication may be verified at any time by contacting ADC’s Technical Assistance Center at 1-800-366-3891, extension 73476 (in U.S.A. or Canada) or 952-917-3476 (outside U.S.A. and Canada), or by e-mail to [email protected]. ADC Telecommunications, Inc. P.O. Box 1101, Minneapolis, Minnesota 55440-1101 In U.S.A. and Canada: 1-800-366-3891 Outside U.S.A. and Canada: (952) 917-3475 Fax: (952) 917-1717 ADCP-75-192 • Issue 1 • December 2005 • Preface Page iii 2005, ADC Telecommunications, Inc. TABLE OF CONTENTS Content Page FRONT MATTER ABOUT THIS MANUAL......................................................................vii RELATED PUBLICATIONS....................................................................vii ADMONISHMENTS.......................................................................viii GENERAL SAFETY PRECAUTIONS..............................................................viii SAVE WORKING DISTANCES..................................................................ix COMPLIANCE STATEMENT...................................................................ix ACRONYMS AND ABBREVIATIONS...............................................................x SECTION 1 OVERVIEW 1 INTRODUCTION....................................................................1-1 2 DIGIVANCE CXD SYSTEM OVERVIEW......................................................1-1 2.1 Basic Components.............................................................1-2 2.2 General Description............................................................1-2 2.3 Local Service Interface..........................................................1-3 2.4 Remote NOC Interface..........................................................1-4 3 SYSTEM FUNCTIONS AND FEATURES......................................................1-4 3.1 Fiber Optic Transport...........................................................1-4 3.2 Control and Monitoring Software...................................................1-5 3.3 Fault Detection and Alarm Reporting.................................................1-5 3.4 Powering...................................................................1-5 3.5 Equipment Mounting and Configuration...............................................1-8 3.6 Hub Subsystem Assemblies.......................................................1-8 3.7 RAN Subsystem Assemblies.....................................................1-11 3.8 Communication Interfaces.......................................................1-14 SECTION 2 DESCRIPTION 1 INTRODUCTION....................................................................2-1 2 DIGITAL CHASSIS...................................................................2-2 3 RF CHASSIS.......................................................................2-5 4 RADIO ACCESS NODE (RAN) ...........................................................2-9 4.1 RAN cabinet................................................................2-10 5 ELEMENTS COMMON TO HUB AND RAN...................................................2-11 5.1 Central Processor Unit (CPU) ....................................................2-11 5.2 System Interface (STF2) ........................................................2-13 5.3 Sonet Interface (SIF) ..........................................................2-15 5.4 Small Form-Factor Optical Transceiver (SFP) .........................................2-16 6 HUB SPECIFIC MODULES.............................................................2-17 ADCP-75-192 • Issue 1 • December 2005 • Preface Page iv 2005, ADC Telecommunications, Inc. TABLE OF CONTENTS Content Page 6.1 Full Band Hub Down Converter (FBHDC) .............................................2-17 6.2 Forward Simulcast Card (FSC) ....................................................2-18 6.3 Hub Upconverter Card (HUC) .....................................................2-19 6.4 Reverse Simulcast Card (RSC) ....................................................2-20 6.5 Hub Reference Module (HRM) ...................................................2-22 6.6 Ethernet Hub................................................................2-24 6.7 BTS Interface Module (BIM) .....................................................2-25 6.8 Attenuator Shelf..............................................................2-28 7 RADIO ACCESS NODE (RAN) SPECIFIC MODULES.............................................2-29 7.1 Ran Down Converter (RDC or RDC2) ...............................................2-29 7.2 Ran Up Converter (RUC2.X or RUC3) ...............................................2-30 7.3 AC Power Entry Controller (APEC)..................................................2-31 7.4 DC Power Entry Controller (DPEC) .....................................…
Text truncated - open the document above for the full version.
Digital Power Corporation 41920 Christy Street Fremont California 94538-3158 Tel: 510.657.2635 Fax: 510.657.6634 www.digipwr.com 10-Oct-2005 Ű Director of Certification Pursuant to RSP-100, Paragraph 10, we, Digital Power Corporation, at 41920 Christy Street, Fremont, CA 94538, hereby requests confidential treatment of information accompanying as outlined below: - Schematics - Parts List The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. Digital Power Corporation requests that Schematics and Parts List be held confidential not only from the public, but also the applicant (ADC Telecommunications). Sincerely, Robert H. Doe 41920 Christy St. Fremont, CA 94538 Direct: 1.510.824.0151 Cell: 1.510.499.8157 Fax: 1.510.657.6634 [email protected]
American Telecommunications Certification Body Inc. 6731 Whittier Ave, McLean, VA 22101 April 12, 2006 RE: FCC ID: F8I-DCX0801B_ATCB003371 Attention: Joel T Schneider / Jolene Murphy I have a few comments on this Application. Please note that further comments may arise in response to answers provided to the questions below. 1. Please note that the conducted output power listed on the 731 for CDMA is 7.69W. However, the report only supports a conducted power of 183mW (see page 20 of the test report). Please note that there is nothing in the report to suggest that measurement methods differ from the other power measurements. Please note however that the 16.23 dB suggested in the report (page 20) is not an average relationship but an apparent relationship between a resolution bandwidth of 30kHz of the analyzer and 1.25MHz OBW of the device. But, as mentioned, there is nothing in the report to suggest this resolution band width was used in actual measurements. Therefore, please note justification for the use of this correction factor does not exists in the report. In order to justify this value you must show the ration of the resolution bandwidth of the analyzer as compared to the OBW of the deviice (i.e. 10Log(1250/30). Please provide full details on the analyzer settings used to make CDMA measurements in the report to support this 16.23 dB factor. Please also include a formula showing how you calculated this factor and how it applies to the data in the table. 2. Please provide analyzer resolution bandwidths and analyzer video bandwidths for the various tests performed in the report. 3. Please note that the statement mentioned in the MPE report as being in the manual cannot be found in the manual. While Rf exposure is addressed at the time of licensing, documentation still needs to be consistent. Please correct all documentation to state the same safe rf separation distances. Dennis Ward mailto:[email protected] The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information may result in application termination. Correspondence should be considered part of the permanent submission and may be viewed from the Internet after a Grant of Equipment Authorization is issued. Please do not respond to this correspondence using the email reply button. In order for your response to be processed expeditiously, you must submit your documents through the AmericanTCB.com website. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the sender.
TÜV America Inc. Phone: (651) 631-2487 1775 Old Highway 8 NW Fax: (651) 638-0285 Suite 104 E-mail: [email protected] New Brighton, MN 55112 www.TUVamerica.com Management Service • Product Service • Industry Service • Automotive • BABT TÜV America Inc. is a subsidiary of TÜV SÜD Group. 25 April 2006 American TCB 6731 Whittier Avenue McLean VA 22101 RE: ADC Telecommunications Inc Response to April 12, 2006 Comments FCC ID: F8I-DCX0801B ATCB003371 In response to your comments on the above submittal from April 12, 2006. 1. ATCB Comments: Please note that the conducted output power listed on the 731 for CDMA is 7.69W. However, the report only supports a conducted power of 183mW (see page 20 of the test report). Please note that there is nothing in the report to suggest that measurement methods differ from the other power measurements. Please note however that the 16.23 dB suggested in the report (page 20) is not an average relationship but an apparent relationship between a resolution bandwidth of 30kHz of the analyzer and 1.25MHz OBW of the device. But, as mentioned, there is nothing in the report to suggest this resolution band width was used in actual measurements. Therefore, please note justification for the use of this correction factor does not exists in the report. In order to justify this value you must show the ration of the resolution bandwidth of the analyzer as compared to the OBW of the device (i.e. 10Log(1250/30). Please provide full details on the analyzer settings used to make CDMA measurements in the report to support this 16.23 dB factor. Please also include a formula showing how you calculated this factor and how it applies to the data in the table. RESPONSE: Test Report WC506388 has been revised to include explanation. 2. ATCB Comments: Please provide analyzer resolution bandwidths and analyzer video bandwidths for the various tests performed in the report. RESPONSE: The RBW and VBW are indicated below each graph and in the text to the right of each graph. (As shown on page A7 of WC506388 Rev A.) 3. ATCB Comments: Please note that the statement mentioned in the MPE report as being in the manual cannot be found in the manual. While Rf exposure is addressed at the time of licensing, documentation still needs to be consistent. Please correct all documentation to state the same safe rf separation distances. RESPONSE: The statement as indicated in the MPE letter has been added to pg ix of the manual (page 11 of 130). The above referenced documents have been uploaded to the website at the same time as this response. Please let us know if anything further is required. Jolene Murphy, Senior Technical Writer TÜV America Inc Tel: 651 638 0271 / Fax: 651 638 0285 [email protected]
HUB Top, Front and left view HUB Top, Front and right view HUB Rear view RAN Front View RAN Right View RAN Back View RAN Left View RAN Top View RAN Bottom View Broadband 10W Cell Band Power Amplifier - Front Broadband 10W Cell Band Power Amplifier - Right Broadband 10W Cell Band Power Amplifier - Rear Broadband 10W Cell Band Power Amplifier - Left Broadband 10W Cell Band Power Amplifier - Top Broadband 10W Cell Band Power Amplifier - Bottom
INFORMATION ON THIS DOCUMENT IS PROPRIETARY TO ADC AND SHALL NOT BE USED, COPIED, REPRODUCED OR DISCLOSED IN WHOLE OR IN PART WITHOUT WRITTEN CONSENT OF ADC TITLE CXD 800 MHz A and B Band FCC / IC Identification Label TOLERANCE UNLESS .XX NA OTHERWISE SPECIFIED .XX NA DRAWING NUMBER None A REV DO NOT SCALE DRAWING ENGR. Mark F. Miska SIZE A SHEET 1 OF 1 REV ECO DWN DATE A MFM 3-28-2006 FCC ID: F8I-DCX0801B IC: 1208G-DCX0801B 1 2 1.500 REF R.075 (4) DIE CUT LABEL .750 REF NOTES: 1 PRINTING TYPE: TRANSFER METHOD. COLOR: BLACK TEXT 8 PT ARIAL NON-BOLD LOCATED APPROXIMATELY AS SHOWN. 2 PRINTING TYPE: TRANSFER METHOD. COLOR: BLACK TEXT 6 PT ARIAL NON-BOLD LOCATED APPROXIMATELY AS SHOWN. MATERIAL: ADC PART NUMBER 1215140 3 Label Placement
HUB Disassembly HUB Disassembly - Closeup View 1 HUB Disassembly - Closeup View 2 RAN Disassembly - Open View RAN Disassembly - Empty View RAN Disassembly - Empty View - Closeup CPU Front CPU back – View 1 CPU back – View 2 Forward Simulcast Card (FSC) Front – View 1 Forward Simulcast Card (FSC) Front – View 2 Forward Simulcast Card (FSC) Back Hub Down Converter (HDC) Front – View 1 Hub Down Converter (HDC) Front – View 2 Hub Down Converter (HDC) Back
HUB System Interface Card (HUBSTF) Front HUB System Interface Card (HUBSTF) Back Hub Up Converter (HUC) Front Hub Up Converter (HUC) back Radio Access Node System Interface Card (RANSTF) Front Radio Access Node System Interface Card (RANSTF) Back RAN Downconverter (RDC) Front RAN Downconverter (RDC) Back Reverse Simulcast Card (RSC) Front Reverse Simulcast Card (RSC) Back RAN Up Converter (RUC) Front RAN Up Converter (RUC) Back Sonet Interface Module (SIF) Front Sonet Interface Module (SIF) Back Base Station Interface Module (BIM) G001 Top - Right Base Station Interface Module (BIM) G001 Top - Left Base Station Interface Module (BIM) G001 Bottom - Right Base Station Interface Module (BIM) G001 Bottom - Left
Broadband 10W LPA 0071-1300 Top Broadband 10W LPA 0071-1300 Bottom Broadband 10W LPA 0071-2300 Top Broadband 10W LPA 0071-2300 Bottom Cherokee Power Supply - Top, Front and Right View Cherokee Power Supply - Top, Back and Left View Cherokee Power Supply - Disassembly View 1 Cherokee Power Supply - Disassembly View 2 Cherokee Power Supply - Board Top Cherokee Power Supply - Board Bottom Digital Power - Power Supply - eFO306-1XX, Top View Digital Power - Power Supply - eFO306-1XX, Output Digital Power - Power Supply - eFO306-1XX, Input Digital Power - Power Supply - eFO306-1XX, ¾ View Digital Power - Power Supply - Board Bottom
TÜV AMERICA INC 19333 Wild Mountain Road Taylors Falls MN 55084-1758 Tel: 651 638 0297 Fax: 651 638 0298 112205 TEST RESULT SUMMARY FCC Part 22 MANUFACTURER ADC Inc. NAME OF EQUIPMENT Digivance® CXD 800 MHz A and B Band MODEL NUMBER DGVF-02000000XXCRN MANUFACTURER'S ADDRESS P.O. Box 1101 Minneapolis, MN 55440-1101 TEST REPORT NUMBER WC506388 Rev A TEST DATES 30 September 2005 (ADC) 14 December 2005 (TÜV) According to testing performed at TÜV America Inc, the above-mentioned unit is in compliance with the electromagnetic compatibility (EMC) portions of the requirements defined in FCC Part 22. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical characteristics. Any modifications necessary for compliance made during testing on the above mentioned date(s) must be implemented in all production units for compliance to be maintained. TÜV America Inc, as an independent testing laboratory, declares that the equipment tested as specified above conforms to the EMC requirements of FCC Part 22, Subpart C Section 22.355, “Frequency tolerance” and Subpart H Sections 22.913 “Effective radiated power limits” and 22.917 “Emission limitations for cellular”. Date: 25 March 2006 Tested By Technical Writer Joe Sausen Greg Jakubowski Not Transferable Rev A File No. WC506388, Page 1 of 16 TÜV AMERICA INC 19333 Wild Mountain Road Taylors Falls MN 55084-1758 Tel: 651 638 0297 Fax: 651 638 0298112205 EMC Emission - T E S T R E P O R T Test Report File No. : WC506388 Rev A Date of issue: 25 April 2006 Model Nos. : DGVF-02000000XXCRN Product Name : Digivance® CXD 800 MHz A and B Band Product Type : Transports RF between a remote antenna and a base station Applicant : ADC Inc. Manufacturer : ADC Inc. License Holder : ADC Inc. Address : P.O. Box 1101 Minneapolis, MN 55440-1101 Test Result : Positive Negative Test Project Number : Reference(s) WC506388 Rev A Total pages including Appendices 157 TÜV America Inc reports apply only to the specific samples tested under stated test conditions. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. TÜV America Inc shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV America Inc issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. This report shall not be used by the client to claim product endorsement by NVLAP, NIST, or any agency of the US government. TÜV America Inc and its professional staff hold government and professional organization certifications and are members of AAMI, ACIL, AEA, ANSI, IEEE, NVLAP, and VCCI Rev A File No. WC506388, Page 2 of 16 TÜV AMERICA INC 19333 Wild Mountain Road Taylors Falls MN 55084-1758 Tel: 651 638 0297 Fax: 651 638 0298112205 REVISION RECORD REVISION TOTAL NUMBER OF PAGES DATE DESCRIPTION 157 16 February 2006 Initial Release A 157 21 April 2006 Revisions include: Pages A2-A3, Updated EIRP Test Data DIRECTORY Documentation Page(s) Test Regulations 3 Test setup drawings and photos 7 – 14 Test Operation Mode 15 Configuration of the device under test 15 Deviations from standard 16 General Remarks 16 Summary 16 Test Results 22.913 Effective radiated power limits 4 22.355 Frequency tolerance 5 22.917 Emission limitations for cellular 6 Appendix A Test data A1 – A131 Appendix B Constructional data form B1 – B8 Appendix C Measurement Protocol C1 – C2 Sign Explanations: - not applicable - applicable File No. WC506388, Page 3 of 16 TÜV AMERICA INC 19333 Wild Mountain Road Taylors Falls MN 55084-1758 Tel: 651 638 0297 Fax: 651 638 0298112205 EMISSIONS TEST REGULATIONS : The emissions tests were performed according to following regulations: - EN 50081-1 / 1991 - EN 55011 / 1991 - Group 1 - Group 2 - Class A - Class B - EN 55013 / 1990 - EN 55014 / 1987 - Household appliances and similar - Portable tools - Semiconductor devices - EN 55014 / A2:1990 - EN 55014 / 1993 - Household appliances and similar - Portable tools - Semiconductor devices - EN 55015 / 1987 - EN 55015 / A1:1990 - EN 55015 / 1993 - EN 55022 / 1987 - Class A - Class B - EN 55022 / 1991 - Class A - Class B - BS - VCCI - Class A - Class B - FCC Part 15 Subpart B - Class A - Class B - FCC Part 15 Subpart C - FCC Part 22 - CISPR 11 (1990) - Group 1 - Group 2 - Class A - Class B - CISPR 22 (1993) - Class A - Class B - IC RSS-Gen Issue 1 - IC RSS-193 Issue 1 Rev A File No. WC506388, Page 4 of 16 TÜV AMERICA INC 19333 Wild Mountain Road Taylors Falls MN 55084-1758 Tel: 651 638 0297 Fax: 651 638 0298112205 22.913 Effective radiated power limits Test summary The requirements are: - MET - NOT MET Minimum margin of compliance is 17.8 dB at 875 MHz (FM, band A) Test location - Wild River Lab Large Test Site (Open Area Test Site) - Wild River Lab Small Test Site (Open Area Test Site) - ADC facility Test Distance - 3 meters - 10 meters - Conducted measurement Test equipment (ADC) Model Number Manufacturer Description ADC Serial Number Cal Due 49-30-33 Aeroflex Attenuator n/a CNR HP8563E HP Spectrum Analyzer MC27690 6-22-06 EPM-441A HP Power Meter MC27670 9-28-06 Equipment with a Calibration Not Required (CNR) listing is verified and compensated for with NIST traceable calibrated equipment. Test limit 500 watts or 57dBm Test Data See page A2 – A3 Rev A File No. WC506388, Page 5 of 16 TÜV AMERICA INC 19333 Wild Mountain Road Taylors Falls MN 55084-1758 Tel: 651 638 0297 Fax: 651 638 0298112205 22.355 Frequency tolerance Test summary The requirements are: - MET - NOT MET The carrier frequency of each channel is maintained within the tole…
Text truncated - open the document above for the full version.
RADIATED EMISSIONS Test Report #: WC506388 Run 1 Test Area: LTS EUT Model #: DGVF-02000000XXCRN Date: 12/14/2005 EUT Serial #: na EUT Power: 48 VDC Temperature: 22.0 °C Test Method: FCC Part 22 H Air Pressure: 98.0 kPa Customer: ADC Telecommunications Rel. Humidity: 22.0 % EUT Description: Digivance CXD 800 MHz full band Notes: 800 MHz. A & B Bands Data File Name: 6388.dat Page: 1of 16 Tested by: J. C. Sausen Printed Signature Reviewed by: Greg Jakubowski Printed Signature List of measurements for run #: 1 FREQ LEVEL (dBuV) CABLE / ANT / PREAMP / ATTEN (dB) FINAL (dBuV / m) POL / HGT / AZ (m)(DEG) DELTA1 -13 dBm >1GHz (Guideline) DELTA2 -13dBm < 1GHz (Guideline) TX setting = 869 MHz 1.006 GHz 51.65 Pk 2.75 / 24.98 / 48.78 / 0.0 30.6 H / 1.00 / 0 -51.63 n/a 1.011 GHz 54.4 Pk 2.76 / 24.99 / 48.81 / 0.0 33.33 H / 1.00 / 0 -48.9 n/a 1.03 GHz 65.7 Pk 2.79 / 25.01 / 48.96 / 0.0 44.54 H / 1.00 / 0 -37.69 n/a 1.073 GHz 54.1 Pk 2.84 / 25.07 / 49.28 / 0.0 32.73 H / 1.00 / 0 -49.5 n/a 1.094 GHz 49.9 Pk 2.87 / 25.1 / 49.45 / 0.0 28.42 H / 1.00 / 0 -53.81 n/a 1.116 GHz 59.55 Pk 2.9 / 25.13 / 49.52 / 0.0 38.06 H / 1.00 / 0 -44.17 n/a 1.124 GHz 52.75 Pk 2.91 / 25.14 / 49.53 / 0.0 31.27 H / 1.00 / 0 -50.96 n/a 1.159 GHz 57.7 Pk 2.96 / 25.18 / 49.59 / 0.0 36.25 H / 1.00 / 0 -45.98 n/a 1.202 GHz 60.05 Pk 3.01 / 25.24 / 49.65 / 0.0 38.65 H / 1.00 / 0 -43.58 n/a 1.223 GHz 50.3 Pk 3.03 / 25.27 / 49.54 / 0.0 29.06 H / 1.00 / 0 -53.17 n/a 1.287 GHz 57.15 Pk 3.11 / 25.36 / 49.21 / 0.0 36.41 H / 1.00 / 0 -45.82 n/a 1.33 GHz 49.15 Pk 3.15 / 25.41 / 49.28 / 0.0 28.44 H / 1.00 / 0 -53.79 n/a 1.373 GHz 58.25 Pk 3.2 / 25.47 / 49.48 / 0.0 37.44 H / 1.00 / 0 -44.79 n/a 1.459 GHz 54.2 Pk 3.38 / 25.59 / 49.73 / 0.0 33.43 H / 1.00 / 0 -48.8 n/a 1.502 GHz 54.5 Pk 3.43 / 25.65 / 49.81 / 0.0 33.77 H / 1.00 / 0 -48.46 n/a 1.503 GHz 54.7 Pk 3.43 / 25.66 / 49.81 / 0.0 33.98 H / 1.00 / 0 -48.25 n/a 1.545 GHz 52.75 Pk 3.47 / 25.85 / 49.67 / 0.0 32.4 H / 1.00 / 0 -49.83 n/a 1.588 GHz 59.3 Pk 3.51 / 26.06 / 49.53 / 0.0 39.34 H / 1.00 / 0 -42.89 n/a 1.631 GHz 53.0 Pk 3.55 / 26.27 / 49.58 / 0.0 33.24 H / 1.00 / 0 -48.99 n/a 1.674 GHz 49.4 Pk 3.59 / 26.47 / 49.7 / 0.0 29.76 H / 1.00 / 0 -52.47 n/a 1.704 GHz 57.2 Pk 3.62 / 26.62 / 49.76 / 0.0 37.68 H / 1.00 / 0 -44.55 n/a 1.717 GHz 52.7 Pk 3.65 / 26.68 / 49.75 / 0.0 33.27 H / 1.00 / 0 -48.96 n/a 1.888 GHz 51.0 Pk 3.86 / 27.5 / 49.93 / 0.0 32.43 H / 1.00 / 0 -49.8 n/a 1.737 GHz 52.4 Pk 3.68 / 26.78 / 49.72 / 0.0 33.13 H / 1.00 / 0 -49.1 n/a 1.931 GHz 52.6 Pk 3.89 / 27.7 / 49.86 / 0.0 34.34 H / 1.00 / 0 -47.89 n/a File No. WC506388, Page A55 of A131 Rev A RADIATED EMISSIONS Test Report #: WC506388 Run 1 Test Area: LTS EUT Model #: DGVF-02000000XXCRN Date: 12/14/2005 EUT Serial #: na EUT Power: 48 VDC Temperature: 22.0 °C Test Method: FCC Part 22 H Air Pressure: 98.0 kPa Customer: ADC Telecommunications Rel. Humidity: 22.0 % EUT Description: Digivance CXD 800 MHz full band Notes: 800 MHz. A & B Bands Data File Name: 6388.dat Page: 2of 16 Tested by: J. C. Sausen Printed Signature Reviewed by: Greg Jakubowski Printed Signature List of measurements for run #: 1 FREQ LEVEL (dBuV) CABLE / ANT / PREAMP / ATTEN (dB) FINAL (dBuV / m) POL / HGT / AZ (m)(DEG) DELTA1 -13 dBm >1GHz (Guideline) DELTA2 -13dBm < 1GHz (Guideline) 1.974 GHz 49.1 Pk 3.9 / 27.91 / 49.7 / 0.0 31.21 H / 1.00 / 0 -51.02 n/a 2.017 GHz 50.85 Pk 3.9 / 28.06 / 49.57 / 0.0 33.23 H / 1.00 / 0 -49.0 n/a 2.103 GHz 50.2 Pk 3.93 / 28.17 / 49.4 / 0.0 32.9 H / 1.00 / 0 -49.33 n/a 2.189 GHz 51.1 Pk 4.05 / 28.28 / 49.42 / 0.0 34.01 H / 1.00 / 0 -48.22 n/a 2.317 GHz 47.3 Pk 4.21 / 28.45 / 49.02 / 0.0 30.94 H / 1.00 / 0 -51.29 n/a 2.488 GHz 50.95 Pk 4.36 / 28.68 / 49.1 / 0.0 34.88 H / 1.00 / 0 -47.35 n/a 2.661 GHz 46.7 Pk 4.45 / 29.13 / 48.38 / 0.0 31.91 H / 1.00 / 0 -50.32 n/a 2.703 GHz 50.3 Pk 4.48 / 29.24 / 48.25 / 0.0 35.77 H / 1.00 / 0 -46.46 n/a 2.746 GHz 48.8 Pk 4.5 / 29.36 / 48.26 / 0.0 34.4 H / 1.00 / 0 -47.83 n/a 2.875 GHz 48.15 Pk 4.63 / 29.71 / 48.46 / 0.0 34.04 H / 1.00 / 0 -48.19 n/a 1.03 GHz 66.0 Pk 2.79 / 25.01 / 48.96 / 0.0 44.84 H / 1.58 / 144 -37.39 n/a 1.116 GHz 63.05 Pk 2.9 / 25.13 / 49.52 / 0.0 41.56 H / 1.58 / 144 -40.67 n/a 1.124 GHz 61.15 Pk 2.91 / 25.14 / 49.53 / 0.0 39.67 H / 1.58 / 144 -42.56 n/a 1.159 GHz 67.0 Pk 2.96 / 25.18 / 49.59 / 0.0 45.55 H / 1.58 / 144 -36.68 n/a 1.202 GHz 70.6 Pk 3.01 / 25.24 / 49.65 / 0.0 49.2 H / 1.58 / 144 -33.03 n/a 1.223 GHz 53.45 Pk 3.03 / 25.27 / 49.54 / 0.0 32.21 H / 1.58 / 144 -50.02 n/a 1.287 GHz 65.5 Pk 3.11 / 25.36 / 49.21 / 0.0 44.76 H / 1.58 / 144 -37.47 n/a 1.33 GHz 61.2 Pk 3.15 / 25.41 / 49.28 / 0.0 40.49 H / 1.58 / 144 -41.74 n/a 1.373 GHz 60.85 Pk 3.2 / 25.47 / 49.48 / 0.0 40.04 H / 1.58 / 144 -42.19 n/a 1.459 GHz 56.45 Pk 3.38 / 25.59 / 49.73 / 0.0 35.68 H / 1.58 / 144 -46.55 n/a 1.502 GHz 55.45 Pk 3.43 / 25.65 / 49.81 / 0.0 34.72 H / 1.58 / 144 -47.51 n/a 1.631 GHz 61.75 Pk 3.55 / 26.27 / 49.58 / 0.0 41.99 H / 1.58 / 144 -40.24 n/a 1.674 GHz 58.8 Pk 3.59 / 26.47 / 49.7 / 0.0 39.16 H / 1.58 / 144 -43.07 n/a 1.717 GHz 57.0 Pk 3.65 / 26.68 / 49.75 / 0.0 37.57 H / 1.58 / 144 -44.66 n/a 1.888 GHz 67.55 Pk 3.86 / 27.5 / 49.93 / 0.0 48.98 H / 1.58 / 144 -33.25 n/a 1.931 GHz 60.65 Pk 3.89 / 27.7 / 49.86 / 0.0 42.39 H / 1.58 / 144 -39.84 n/a File No. WC506388, Page A56 of A131 Rev A RADIATED EMISSIONS Test Report #: WC506388 Run 1 Test Area: LTS EUT Model #: DGVF-02000000XXCRN Date: 12/14/2005 EUT Serial #: na EUT Power: 48 VDC Temperature: 22.0 °C Test Method: FCC Part 22 H Air Pressure: 98.0 kPa Customer: ADC Telecommunications Rel. Humidity: 22.0 % EUT Description: Digivance CXD 800 MHz full band Notes: 800 MHz. A & B Bands Data File Name: 6388.dat Page: 3of 16 Tested by: J. C. Sausen Printed Signature Reviewed by: Greg Jakubowski Printed Signature List of measurements for run #: 1 FREQ LEVEL (dBuV) CABLE / ANT / PREAMP / ATTEN (dB) FINAL (dBuV / m) POL / HGT / AZ (m)(DEG) DELTA1 -13 dBm >1GHz (Guideline) DELTA2 -13dBm < 1GHz (Guideline) 1.974 GHz 57.2 Pk 3.9 / 27.91 / 49.7 …
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 5 | 22H | 869 MHz - 894 MHz | 7.69 W | 1M23F9W | 1.5 ppm |

FWP-T4MT000MOD-L
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FWP-W4MT000MOD
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FWP-44MT000MOD
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FWP-84MTA4MMOD
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FlexWave Prism HDM 850 MHz MIMO
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)