FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ADC Telecommunications Inc/
  3. F8I-PSM0800M

F8I-PSM0800MFWP-44MT000MOD

ADC Telecommunications Inc
FWP-44MT000MOD - FCC ID F8I-PSM0800M - ADC Telecommunications Inc
Click to zoom

Application Details

Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
Date of Grant
Aug 26, 2014
Application Purpose
Original Equipment
Date of Application
Aug 24, 2014
Equipment Note
FWP-44MT000MOD
Frequency Range
862.00000000 - 869.00000000
Company
ADC Telecommunications Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗
↗

Internal Photos

↗

Operational Description

↗

Parts List/Tune Up Info

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Dual-Band Dual-Slot RF Module Single-Slot RF Module Legacy Dual-Slot 40W RF Module HDM RF Module FlexWave Prism and Spectrum Software Release 8.1.4.7 Release Notes TECP‐77‐141 ∙ Issue 6 ∙ July 2014 TE Connectivity, TE and TE connectivity (logo) FlexWave, InterReach, InterReach Fusion and InterReach Unison are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be rel iable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity's obligations shall only be as set forth in TE Connectivity's Standard Terms and Conditions of Sale for this product and in no case will TE Co nnectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. This manual provides the information you need to install TE Connectivity FlexWave Prism ® RF Modules into a Prism Remote Unit (PRU). Installation instructions are provide d for the following Prism Remote Unit RF Modules: •Single‐Bay R F Modules, which includes the HDM RF Modules •Dual‐Bay RF Modules –Dual‐Band RF Modules –Legacy 40W RF Modules. Page 2FlexWave Prism Remote Unit RF Module Installation Guide ©2014 TE ConnectivityTECP‐77‐141 Issue 6 • 300001744178 Rev F • July 2014 TABLE OF CONTENTS Document Overview ...........................................................................................................................................................................................3 Revision History.......................................................................................................................................................................................................5 Document Cautions and Notes ...............................................................................................................................................................................5 Abbreviations Used in this Guide............................................................................................................................................................................5 Overview of RF Modules for Prism Remote Units ................................................................................................................................................6 RF Module DARTs....................................................................................................................................................................................................7 RF Module Types.....................................................................................................................................................................................................8 Single‐ and Dual‐Bay RF Modules with Classic or SuperDARTs.......................................................................................................................8 HDM RF Modules ............................................................................................................................................................................................9 Legacy Dual‐Bay 40W RF Modules................................................................................................................................................................10 RF Module Components....................................................................................................................................................................................11 Duplexer and Low Noise Amplifier........................................................................................................................................................................12 Linear Power Amplifiers........................................................................................................................................................................................12 Digital Processing Module.....................................................................................................................................................................................13 Understanding the RF Module Cables................................................................................................................................................................13 Power Cable Connection.......................................................................................................................................................................................13 LVDS Cable Connections........................................................................................................................................................................................13 RF Cable Connections............................................................................................................................................................................................14 RF Cable Rules ...............................................................................................................................................................................................14 RF Module Cables for Single‐Card, Dual‐Card, and HDM RF Modules..........................................................................................................15 RF Module Cables for Dual‐Bay Installations ................................................................................................................................................16 RF Group Assignments for PRUs .......................................…

Text truncated - open the document above for the full version.

Cover Letter(s)

Mailing Address: 501 Shenandoah Drive, Shakopee, Minnesota 55379 www.te.com July 17, 2014 Attention: Reviewing Engineering Type of Certification: Original - FCC Part 90 Applicant: ADC Telecommunications Inc. Equipment: FlexWave™ Prism – HDM 20 Watt 800 MHz MIMO Model #: FWP-44MT000MOD FCC ID: F8I-PSM0800M Dear Sir/Madam: Enclosed please find a signed FR410 TCB Application for certification of the above mentioned RF module. Further details and supporting documents have been uploaded to the Northwest EMC CTS system. Should you have any questions, please feel free to contact the undersigned. Sincerely, Joshua J. Wittman Compliance Engineer Tele: 952 403-8322 Fax: 952 403-8858 Email: [email protected]

Cover Letter(s)

1(1) Attention: Application Examiner Re: Request for Confidentiality Applicant: ADC Telecommunications, Inc. FCC ID: F8I-PSM0800M To whom it may concern, Permanent Confidentiality Request is hereby submitted by ADC Telecommunications, Inc. to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential: • Schematics • Detailed Block diagrams • Detailed Operational/Functional Description Rationale for request for confidentiality: ADC Telecommunications, Inc. has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. If you have questions or need further information, please contact the undersigned. Sincerely, Joshua J. Wittman Compliance Engineer ADC Telecommunications, Inc.

Cover Letter(s)

WTD 13.4.9 FCC Compliance Opinion TECO0016 Information about the Applicant Grantee (Company Name) ADC Telecommunications, Inc. FCC Contact Person Joshua Wittman Address 510 Shenandoah Drive City, State, Zip Shakopee, MN 55379 Job Number TECO0016 Model FWP-44T000MOD FCC ID F8I-PSM800M Agent N/A Approval Type Original Equipment Class B2I Industrial Booster Rule Part 90 Overview The FlexWave PRISM, in its most basic configuration, serves as a transport between a FCC approved base station and a remote antenna. The system consists of two units; a “host”, that is co-located with the base station, and a “remote”, that resides at the location of the antenna. Both units perform wide band digitization, fiber optic transport, and reconstruction of the RF signal. In addition to RF transport, Flexwave PRISM also provides 10/100bT Ethernet connectivity between the host and all connected remotes. The entire system is monitored and controlled via an onboard web server that is accessible with a standard web browser. Confidentiality requested for allowed files. Request is properly addressed and referenced. Recommendation All items have been resolved and completed to my satisfaction; therefore I recommend this application for approval. Signature , TCB Committee 8/14/2014

External Photos

FWP-44MT000MOD External Photos RF Module Assembly #1 FCC/IC Label Location FWP-44MT000MOD External Photos RF Module Assembly #2 FWP-44MT000MOD External Photos RF Module Assembly #3 Location of “Industrial Signal Booster Warning Label” FWP-44MT000MOD External Photos RF Module Assembly #4 FWP-44MT000MOD External Photos RF Module Assembly #5 FWP-44MT000MOD External Photos RF Module Assembly #6 FCC/IC Label Location FWP-44MT000MOD External Photos RF Module Assembly #7 FWP-44MT000MOD External Photos RF Module Assembly #8

ID Label/Location Info

INFORMATION ON THIS DOCUMENT IS PROPRIETARY TO ADC AND SHALL NOT BE USED, COPIED, REPRODUCED OR DISCLOSED IN WHOLE OR IN PART WITHOUT WRITTEN CONSENT OF ADC TITLE FlexWave™ Prism – HDM 20W 800 MHz MIMO FCC/IC Identification Label TOLERANCE UNLESS .XX NA OTHERWISE SPECIFIED .XX NA DRAWING NUMBER None A REV DO NOT SCALE DRAWING ENGR. Joshua J. Wittman SIZE A SHEET 1 OF 1 REV ECO DWN DATE A JJW 7-17-2014 Model: FWP-44MT000MOD FCC: F8I-PSM0800M IC: 1208G-PSM0800M 2 1.500 REF R.075 (4) DIE CUT LABEL .750 REF 1 NOTES: 1 PRINTING TYPE: TRANSFER METHOD. COLOR: BLACK TEXT 8 PT ARIAL NON-BOLD LOCATED APPROXIMATELY AS SHOWN. 2 PRINTING TYPE: TRANSFER METHOD. COLOR: BLACK TEXT 6 PT ARIAL NON-BOLD LOCATED APPROXIMATELY AS SHOWN. MATERIAL: ADC PART NUMBER 1215140 3

ID Label/Location Info

FCC ID and Industrial Booster Warning Label Location on Chassis Industrial Booster Label Chassis Location FCC/IC Label Chassis Location

Internal Photos

FWP-44MT000MOD Internal Photos Motherboard – Front #1 FWP-44MT000MOD Internal Photos Motherboard – Front #2 FWP-44MT000MOD Internal Photos Motherboard – Front #3 FWP-44MT000MOD Internal Photos Motherboard – Back #1 FWP-44MT000MOD Internal Photos Motherboard – Back #2 FWP-44MT000MOD Internal Photos Motherboard – Back #3 FWP-44MT000MOD Internal Photos Tx Board – Front Tx Radio FWP-44MT000MOD Internal Photos Tx Board – Back FWP-44MT000MOD Internal Photos Rx Board – Front FWP-44MT000MOD Internal Photos Rx Board – Back FWP-44MT000MOD Internal Photos Duplexer #1 FWP-44MT000MOD Internal Photos Duplexer #2 Antenna port FWP-44MT000MOD Internal Photos Duplexer #3 FWP-44MT000MOD Internal Photos LPA #1 FWP-44MT000MOD Internal Photos LPA #2 FWP-44MT000MOD Internal Photos LPA #3

Operational Description

Mailing Address: 501 Shenandoah, Shakopee, Minnesota 55379 www.te.com July 17, 2014 Antenna Information Attention: Reviewing Engineering Type of Certification: Original - FCC Part 90 Applicant: ADC Telecommunications, Inc. Equipment: FlexWave™ Prism – HDM 20 Watt 800 MHz MIMO Model #: FWP-44MT000MOD FCC ID: F8I-PSM0800M Dear Sir/Madam: We, ADC Telecommunications, Inc. do not manufacture or distribute any antennas to our customers for their deployments. The customer provides their own. Dipole and omni antennas with a typical gain of 6dBi will be used with this product. Further details and supporting documents have been uploaded to the Northwest EMC CTS system. Should you have any questions, please feel free to contact the undersigned. Sincerely, Joshua J. Wittman Compliance Engineer Tele: 952 403-8322 Fax: 952 403-8858 Email: [email protected]

Parts List/Tune Up Info

Mailing Address: 1187 Park Place, Shakopee, Minnesota 55379 www.TE.com August 18, 2014 Attn: Application Examiner, Reviewing Engineer Re: Tune-up Procedure The FlexWave™ Prism – HDM 20 Watt 800 MHz MIMO model number FWP-44MT000MOD employs a solid-state design that does not require a tune-up procedure. Sincerely, Joshua J. Wittman Compliance Engineer Tele: 952 403-8322 Fax: 952 403-8858 Email: [email protected]

RF Exposure Info

Mailing Address: P.O. Box 1101, Minneapolis, Minnesota 55440-1101 World Headquarters: Minneapolis, Minnesota USA +1.952.938.8080 www.adc.com April 21, 2014 Attn: Application Examiner, Reviewing Engineer Re: RF Exposure Statement The antenna(s) used for this transmitter must be fixed-mounted on (outdoor/indoor) structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 47 CFR 1.1307 (b)(3) Sincerely, Joshua J. Wittman Compliance Engineer Tele: 952 403-8322 Fax: 952 403-8858 Email: [email protected]

Test Report

TE Connectivity / ADC Telecommunications Prism HDM 800 MHz/Prism 800 MIMO RF Module FCC 90I:2014 Report #: TECO0016 Report Prepared By Northwest EMC Inc. NORTHWEST EMC – (888) 364-2378 – www.nwemc.com California – Minnesota – Oregon – New York – Washington WTD 12.5.23 CERTIFICATE OF TEST Last Date of Test: July 14, 2014 TE Connectivity / ADC Telecommunications Model: Prism HDM 800 MHz Emissions Test Description Specification Test Method Pass/Fail Conducted Output Power FCC 90I:2014 , FCC 2.1046 ANSI/TIA/EIA-603-C-2004 Pass Out of Band Emissions –Conducted FCC 90I:2014 , FCC 2.1051 ANSI/TIA/EIA-603-C-2004 Pass Intermodulation FCC 90I:2014 , FCC 2.1051 ANSI/TIA/EIA-603-C-2004 Pass Frequency Stability FCC 90I:2014 , FCC 2.1055 ANSI/TIA/EIA-603-C-2004 Pass Occupied Bandwidth FCC 90I:2014 , FCC 2.1049 ANSI/TIA/EIA-603-C-2004 Pass Field Strength of Spurious Emissions FCC 90I:2014 , FCC 2.1053 ANSI/TIA/EIA-603-C-2004 Pass Deviations From Test Standards None Approved By: Tim O'Shea, Operations Manager NVLAP Lab Code: 200881-0 This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government of the United States of America. Product compliance is the responsibility of the client, therefore the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. This Report may only be duplicated in its entirety. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. REV 2012.08.02 REVISION HISTORY Revision Number Description Date Page Number 00 None Barometric Pressure The recorded barometric pressure has been normalized to sea level. REV 2012.05.24 ACCREDITATIONS AND AUTHORIZATIONS United States FCC - Designated by the FCC as a Telecommunications Certification Body (TCB). Certification chambers, Open Area Test Sites, and conducted measurement facilities are listed with the FCC. A2LA - Accredited by A2LA to ISO / IEC Guide 65 as a product certifier. This allows Northwest EMC to certify transmitters to FCC and IC specifications. NVLAP - Each laboratory is accredited by NVLAP to ISO 17025 Canada IC - Recognized by Industry Canada as a Certification Body (CB). Certification chambers and Open Area Test Sites are filed with IC. European Union European Commission – Validated by the European Commission as a Conformity Assessment Body (CAB) under the EMC directive and as a Notified Body under the R&TTE Directive. Australia/New Zealand ACMA - Recognized by ACMA as a CAB for the acceptance of test data. Korea KCC / RRA - Recognized by KCC’s RRA as a CAB for the acceptance of test data. Japan VCCI - Associate Member of the VCCI. Conducted and radiated measurement facilities are registered. Taiwan BSMI – Recognized by BSMI as a CAB for the acceptance of test data. NCC - Recognized by NCC as a CAB for the acceptance of test data. Singapore IDA – Recognized by IDA as a CAB for the acceptance of test data. Hong Kong OFTA – Recognized by OFTA as a CAB for the acceptance of test data. Vietnam MIC – Recognized by MIC as a CAB for the acceptance of test data. Russia GOST – Accredited by Certinform VNIINMASH, CERTINFO, SAMTES, and Federal CHEC to perform EMC and Hygienic testing for Information Technology products to GOST standards. SCOPE For details on the Scopes of our Accreditations, please visit: http://www.nwemc.com/accreditations/ REV 2013.03.8 MEASUREMENT UNCERTAINTY Measurement Uncertainty When a measurement is made, the result will be different from the true or theoretically correct value. The difference is the result of tolerances in the measurement system that cannot be completely eliminated. To the extent that technology allows us, it has been our aim to minimize this error. Measurement uncertainty is a statistical expression of measurement error qualified by a probability distribution. A measurement uncertainty estimation has been performed for each test per our internal quality document WP 342. The estimation is used to compare the measured result with its "true" or theoretically correct value. The expanded measurement uncertainty (K=2) for each test is listed below. Our measurement data meets or exceeds the measurement uncertainty requirements of the applicable specification; therefore, the test data can be compared directly to the specification limit to determine compliance. The calculations for estimating measurement uncertainty are based upon ETSI TR 100 028 (or CISPR 16-4-1 as applicable), and are available upon request. The following table represents the Measurement Uncertainty (MU) budgets for each of the tests that may be contained in this report. Test + MU - MU Frequency Accuracy (Hz) 0.12 -0.01 Amplitude Accuracy (dB) 0.49 -0.49 Conducted Power (dB) 0.41 -0.41 Radiated Power via Substitution (dB) 0.69 -0.68 Temperature (degrees C) 0.81 -0.81 Humidity (% RH) 2.89 -2.89 Field Strength (dB) 3.80 -3.80 AC Powerline Conducted Emissions (dB) 2.94 -2.94 REV 2013.06.28 FACILITIES Oregon Labs EV01-12 22975 NW Evergreen Pkwy Hillsboro, OR 97124 (503) 844-4066 California Labs OC01-13 41 Tesla Irvine, CA 92618 (949) 861-8918 New York Labs NY01-04 4939 Jordan Rd. Elbridge, NY 13060 (315) 685-0796 Minnesota Labs MN01-08 9349 W Broadway Ave. Brooklyn Park, MN 55445 (763) 425-2281 Washington Labs NC01-05,SU02,SU07 19201 120 th Ave. NE Bothell, WA 98011 (425) 984-6600 VCCI A-0108 A-0029 A-0109 A-0110 Industry Canada 2834D-1, 2834D-2 2834B-1, 2834B-2, 2834B-3 2834E-1 2834F-1 NVLAP NVLAP Lab Code: 200630-0 NVLAP Lab Code: 200676-0 NVLAP Lab Code: 200761-0 NVLAP Lab Code: 200881-0 NVLAP Lab Code: 200629-0 WTD 12.5.23 PRODUCT DESCRIPTION Client and Equipment Under Test (EUT) Information Company Name: TE Connectivity / ADC Telecommunications Address: 1187 Park Place City, State, Zip: Shakopee, MN 55379 Test Requested By: Joshua Wittman Model: Prism HDM 800 MHz Fir…

Text truncated - open the document above for the full version.

Test Setup Photos

CONDUCTED OUTPUT POW ER XMit 2013.08.15 NORTHWEST CONDUCTED OUTPU PsaTx 2013.10.23 EMC DIRECT 001.jpg DIRECT 002.jpg CONDUCTED OUTPUT POWER Report No. TECO00161 OUT OF BAND EMISSIONS -CONDUCTED XMit 2013.08.15 NORTHWEST OUT OF BAND EMISS PsaTx 2013.10.23 EMC DIRECT 001.jpg DIRECT 002.jpg OUT OF BAND EMISSIONS - CONDUCTED Report No. TECO00162 INTERMODULATION XMit 2013.08.15 NORTHWEST INTERMODULATION EMC DIRECT 002.jpg DIRECT COMB 002.jpg INTERMODULATION Report No. TECO00163 FREQUENCY STABILITY XMit 2013.08.15 NORTHWEST FREQUENCY STABIL PsaTx 2013.10.23 EMC FSB 001.jpg FREQUENCY STABILITY Report No. TECO00164 OCCUPIED BANDWIDTH (26 dB) XMit 2013.08.15 NORTHWEST OCCUPIED BANDWID PsaTx 2013.10.23 EMC DIRECT 001.jpg DIRECT 002.jpg OCCUPIED BANDWIDTH (26 dB) Report No. TECO00165 photo SE (1).JPG SE (2).JPG FIELD STRENGTH OF SPURIOUS EMISSIONS PSA-ESCI 2014.06.19 Report No. TECO00166

Contact Information

Applicant

Joshua Wittman(Compliance Engineer)
[email protected]952-403-8322Fax: 952-403-8858

Test Firm

Northwest EMC, Inc.Greg Kiemel
[email protected]503-844-4066Fax: 503-844-3826

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
390S862 MHz - 869 MHz24.95 W3M03G7D0.04 ppm
Confidentiality
Long Term
Grant Notes
Output power is per channel, RMS average conducted. This application covers only the booster system configuration with Host Unit connected to a basestation in the uplink path; operations if any with Host Unit connected to antenna or amplifier in the uplink require separate equipment authorization for the reverse path of the Remote Unit. The antenna(s) used for this transmitter must be fixed-mounted on (outdoor/indoor) permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 47 Cfr. 1.307(b)(3).

Other Applications from ADC Telecommunications Inc

FWP-T4MT000MOD-L - FCC ID F8I-PSM25TDL - ADC Telecommunications Inc
F8I-PSM25TDL

FWP-T4MT000MOD-L

Sep 28, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
FWP-W4MT000MOD - FCC ID F8I-PSM230WM - ADC Telecommunications Inc
F8I-PSM230WM

FWP-W4MT000MOD

Jul 29, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
FWP-84MTA4MMOD - FCC ID F8I-PSM1921D - ADC Telecommunications Inc
F8I-PSM1921D

FWP-84MTA4MMOD

Aug 24, 2014

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
FlexWave Prism HDM 850 MHz MIMO - FCC ID F8I-PSM0850M - ADC Telecommunications Inc
F8I-PSM0850M

FlexWave Prism HDM 850 MHz MIMO

Jul 27, 2014

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
FWP-441T841MOD - FCC ID F8I-PSM8019D - ADC Telecommunications Inc
F8I-PSM8019D

FWP-441T841MOD

May 04, 2014

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)