ADC FlexWave ™ Prism Host, Remote and EMS 5.1 System Reference D-620098-0-20 Rev B Antenna Antenna Antenna Quad Band Remote Unit Host Unit Antenna 77073-001 ADCP-77-073x Issue 2 x 11/2009 ADC Telecommunications, Inc. P.O. Box 1101, Minneapolis, Minnesota 55440-1101 In U.S.A. and Canada: 1-800-366-3891 Outside U.S.A. and Canada: (952) 938-8080 Fax: (952) 917-1717 Copyright © 2009 ADC Telecommunications, Inc. All Rights Reserved. Information contained in this document is company private to ADC Telecommunications, Inc. and shall not be modified, used, copied, reproduced or disclosed in whole or in part without the written consent of ADC. Trademark Information ADC is a registered trademark and FlexWave is a trademark of ADC Telecommunications, Inc. No right, license, or interest to such trademarks is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark. Other product names mentioned in this practice are used for identification purposes only and may be trademarks or registered trademarks of their respective companies. Disclaimer of Liability Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. Should the content of printed user documentation shipped with product differ from documentation provided on a product CD (inclusive of the associated Help modules), the printed user documentation supersedes the documentation on the product CD. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits, and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. Specific Disclaimer for High-Risk Activities This Software Product is not specifically designed, manufactured, tested or intended for use in high- risk activities including, without restricting the generality of the foregoing, on-line control of aircraft, air traffic, aircraft navigation or aircraft communications; or in the design, construction, operation or maintenance of any nuclear facility. ADC (including its affiliates) and its suppliers specifically disclaim any express or implied warranty of fitness for such purposes or any other purposes. Screenshots in User Documentation Due to concurrent development of this documentation, artwork, and the FlexWave URH EMS product, there may be some minor discrepancies between screenshots contained in this documentation and those actually displayed in the FlexWave URH EMS. These discrepancies will generally be few and minor and should not affect your understanding of FlexWave URH EMS. FlexWave Prism Host, Remote and EMS 5.1 System ReferencePage iii ADCP-77-073 • Issue 2 • 11/2009©2009 ADC Telecommunications, Inc. TABLE OF CONTENTS Preface _______________________________________________ix FlexWave Prism User Documentation........................................................................... x Following the EMS Procedures in This Document...........................................................xi General Safety Precautions .......................................................................................xii Standards Certification ............................................................................................ xiii Part I: FlexWave Prism System Overview ____________1 Chapter 1: FlexWave Prism System _________________________ 3 1.1 Prism System Overview ....................................................................................... 4 1.1.1 Product Features ......................................................................................... 4 1.1.2 Applications ................................................................................................ 5 1.2 Basic System Components.................................................................................... 6 1.3 Multi-Host Systems ........................................................................................... 10 1.4 DART Cards ...................................................................................................... 12 1.4.1 DARTs and Host Units ................................................................................ 13 1.4.2 DARTs and Remote Units ............................................................................ 15 1.5 E911 Support ................................................................................................... 16 1.6 Fiber Optic Transport ......................................................................................... 17 1.7 Timeslots Versus Bandwidth ............................................................................... 19 1.8 Bandwidths ...................................................................................................... 20 1.9 AWS and PCS Band Options ................................................................................ 24 Page ivFlexWave Prism Host, Remote and EMS 5.1 System Reference © 2009 ADC Telecommunications, IncADCP-77-073 • Issue 2 • 11/2009 Chapter 2: Prism System Components ______________________ 27 2.1 FlexWave Prism Family Overview ........................................................................ 28 2.2 FlexWave Prism Host Units ................................................................................. 30 2.2.1 Host Front Panel........................................................................................ 30 2.2.2 Host Network Connection ........................................................................... 33 2.2.3 Host RF Signal Connections......................................................................... 33 2.2.4 Host System Card...................................................................................... 34 2.3 Prism Remote Units ..................................…
Text truncated - open the document above for the full version.
FlexWave Prism Host, Remote and EMS 5.1 System ReferencePage 93 ADCP-77-073 • Issue 2 • 11/2009©2009 ADC Telecommunications, Inc. 4 INSTALLING THE REMOTE UNIT 4.1 Remote Installation Overview ............................................................................. 94 4.1.1 Installation Hardware Provided with Remote.................................................. 94 4.1.2 Required Tools and Materials....................................................................... 95 4.2 Remote Mounting Plans...................................................................................... 96 4.3 Install the Remote............................................................................................. 97 4.3.1 Unpack and Inspect the Remote and Components .......................................... 97 4.3.2 Install the Remote RF Module(s) .................................................................. 98 4.4 Install any 40W RF Module(s) ............................................................................107 4.4.1 Prepare the Remote and RF Module.............................................................108 4.4.2 Remove Module Shelf(s) ............................................................................108 4.4.3 Install the 40W RF Module .........................................................................110 4.4.4 Ground Wire Installation............................................................................118 4.4.5 Network Cable Installation .........................................................................119 4.4.6 Quad Fiber Cable Installation .....................................................................121 4.4.7 Antenna Cable Installation .........................................................................123 4.4.8 AC Power Wiring Installation ......................................................................125 4.4.9 Determine the Circuit Breaker or Fuse for Remote.........................................129 4.4.9.1 Power Consumption ..........................................................................129 4.4.9.2 Power Consumption Tables.................................................................131 4.4.10 Mount the Remote and Power Up ..............................................................132 ContentPage Installing the Remote Unit Page 94FlexWave Prism Host, Remote and EMS 5.1 System Reference © 2009 ADC Telecommunications, IncADCP-77-073 • Issue 2 • 11/2009 4.1REMOTE INSTALLATION OVERVIEW Installation of the Remote consists of the following basic steps: 11 Unpack and inspect your shipment. 22 Install the RF module(s). 33 Connect the ProAx Fiber Cables. 44 Connect external coaxial antenna cables must be routed from the antenna to the Remote TX0/RX0 and RX1 connectors. 55 Install the AC power cable and connect it the Remote’s AC power port and to an external junction box . 4.1.1Installation Hardware Provided with Remote The installation hardware provided with the Remote is listed in Table 4-1. To insure that all connectors and ports remain dust-free during installation, leave all dust caps and dust protectors in place until directed to remove them. Table 4-1.Remote Unit Installation Hardware ItemQuantity AC Power Cable (15 feet/4.6m)1 Quad Fiber Cable Assembly1 (a) (a) If the Remote has more than 2 SFPs, two Quad Fiber Cable Assemblies are required. 3/8-inch hex standoff3 3/8-inch 10-32 phillips screw3 #10 split washer3 Remote Installation Overview FlexWave Prism Host, Remote and EMS 5.1 System ReferencePage 95 ADCP-77-073 • Issue 2 • 11/2009© 2009 ADC Telecommunications, Inc. 4.1.2Required Tools and Materials The following tools are required in order to complete the procedures in this instruction: •• Socket Wrench and 3/8-inch Deep Socket •• Wire cutters •• Wire stripper •• Compression pliers for splicing grounding cable •• Tools for installing exterior AC circuit •• Tool kit for attaching N-Type connectors to coaxial cable •• Fiber cleaning kit The following materials are required in order to complete the installation procedures: •• #6 AWG (4 mm) copper wire and splice •• #10 ring terminal for attaching #6 grounding wire to bottom of unit •• Connector for attaching #6 grounding wire to approved earth ground source •• Junction box, conduit, fasteners, connectors, and wire to install an exterior AC circuit. •• N-Type male connectors •• RJ-45 connector (if making a permanent external network cable connection) Installing the Remote Unit Page 96FlexWave Prism Host, Remote and EMS 5.1 System Reference © 2009 ADC Telecommunications, IncADCP-77-073 • Issue 2 • 11/2009 4.2REMOTE MOUNTING PLANS The FlexWave Prism Remote Unit has a low profile design that requires minimal real estate for installation. The basic dimensions and weights of the Remote are listed in Table 4-2. The Prism Remote should be mounted on a utility pole, mast, or on a flat surface. A mounting kit is available for each unit. Installation consists of securing the bracket to the mounting surface (wood, concrete, or steel) and then hanging the unit from the bracket. The Remote should only be mounted in a restricted access location. Detailed instructions for mounting the FlexWave Prism Remote are in the Remote Unit Mounting Kit Installation Instructions (ADCP-77-077). Table 4-2.Remote Dimensions Remote ConfigurationDepthWidthHeightWeight of Fully Populated Units Single-Band 10.51 " 12.15 " 22.50" < 65 lbs Double Band 10.51 " 12.15 " 30.50" < 96 lbs Triple Band 10.51 " 12.15 " 38.46" < 127 lbs Quad-Band 10.51 " 12.15 " 49.60" <1 65 lbs Install the Remote FlexWave Prism Host, Remote and EMS 5.1 System ReferencePage 97 ADCP-77-073 • Issue 2 • 11/2009© 2009 ADC Telecommunications, Inc. 4.3INSTALL THE REMOTE This chapter guides you through installing a Prism Remote, which requires 63 steps that are divided into 9 sections. Follow the steps in the order in which they are provided. 4.3.1Unpack and Inspect the Remote and Components This section provides instruc…
Text truncated - open the document above for the full version.
FlexWave Prism Host, Remote and EMS 5.1 System ReferencePage 213 ADCP-77-073 • Issue 2 • 11/2009©2009 ADC Telecommunications, Inc. 9 MANAGING HOST UNITS 9.1 Viewing the Host Summary................................................................................214 9.2 Resetting the Host Unit .....................................................................................215 9.3 Viewing Host SeRF Ethernet Ports.......................................................................217 9.4 Decommissioning a DART in a Host.....................................................................220 9.5 Viewing the Host SeRF Summary........................................................................222 9.6 Viewing Host SeRF Optical Ports .........................................................................224 9.7 Viewing Host DART Alarms ................................................................................226 ContentPage Managing Host Units Page 214FlexWave Prism Host, Remote and EMS 5.1 System Reference © 2009 ADC Telecommunications, IncADCP-77-073 • Issue 2 • 11/2009 9.1VIEWING THE HOST SUMMARY This section describes the read-only status indicators in the Host Summary view. For information on setting Host attributes, see “Enter a Host Name, Clock Source, and Linking Mode” on page 147 and “Changing to Built-In Network Mode” on page 186. To open the Host Summary view in the EMS View Frame, in the Function Explorer Tree select System View, and then click on the Host name node. The read-only status indicators are: • SERF—Current summary alarm state of Host SeRF card. Red indicates that a major alarm exists for some component module of the SeRF. Yellow indicates a minor alarm. • DART—Current summary alarm state is indicated by status indicator on same row of page. Red indicates that a major alarm exists for the DART. Yellow indicates a minor alarm. • Host Major Contact Alarm Output—Dry alarm NO/NC contact (labeled ALARM OUTPUTS HOST) on the Host. Current state of major alarm contacts is indicated by Alarm Summary status indicator on same row of page. • Host Minor Contact Alarm Output—Dry alarm NO/NC contact (labeled ALARM OUTPUTS HOST) on the Host. Current state of minor alarm contacts is indicated by Alarm Summary status indicator on same row of page. • Remote Major Contact Alarm Output—Red indicates Host NO/NC major alarm contacts are in an alarm position. These connections are typically wired to a local alarm alert system. This status indicator is red when a major alarm is present on any Remote connected to the Host. • Remote Minor Contact Alarm Output—Red indicates that Host NO/NC minor alarm contacts are in an alarm position. These connections are typically wired to a local alarm alert system. This status indicator is red when a minor alarm is present on any Remote connected to Host. Resetting the Host Unit FlexWave Prism Host, Remote and EMS 5.1 System ReferencePage 215 ADCP-77-073 • Issue 2 • 11/2009© 2009 ADC Telecommunications, Inc. 9.2RESETTING THE HOST UNIT 11 In the Function Explorer Tree, select System View, and then click on the Host name node to open the Host Summary view in the EMS View Frame. 22 Click Reset Unit. Only a user logged in under the admin or a Network Manager account can change Prism system settings t hrough the EMS. Resetting the Host Unit results in a Loss of Service condition for the Host and connected Remotes unt il the Host comes back up. Depending on the system configuration, it can take 5 to 20 minutes for man agement communication to be restored. Managing Host Units Page 216FlexWave Prism Host, Remote and EMS 5.1 System Reference © 2009 ADC Telecommunications, IncADCP-77-073 • Issue 2 • 11/2009 33 In the confirmation dialog, click OK. Once you click OK, the confirmation dialog closes and the Host reboots. It will take some time for the Host to retrieve data from connected Remotes and to reconfigure data on the Remotes. During this time, an alert message displays in the Host Summary view and on any other page where data can be set. Any attempt to SET will fail. You cannot make configuration changes while this message is displayed. Wait until the message clears before continuing with configuration settings. Viewing Host SeRF Ethernet Ports FlexWave Prism Host, Remote and EMS 5.1 System ReferencePage 217 ADCP-77-073 • Issue 2 • 11/2009© 2009 ADC Telecommunications, Inc. 9.3VIEWING HOST SERF ETHERNET PORTS The Host ENET Configurations view is a summary of throughput and number of errors on the twelve Ethernet (ENET) ports on the Host SeRF card. These ports consist of eight ports used for connection to Remotes and four ports used for system management and maintenance functions. 11 In the Function Explorer Tree, select System View,Host-x,SERF,ENET (where -x is the Host name) to open the ENET Configurations view in the EMS View Frame. Managing Host Units Page 218FlexWave Prism Host, Remote and EMS 5.1 System Reference © 2009 ADC Telecommunications, IncADCP-77-073 • Issue 2 • 11/2009 22 (Optional) To enlarge the view, click Full Screen to open a separate window that shows only the ENET Configurations table. 33 To update the counters, click Refresh. The ENET Configurations view lists the Ethernet ports and their corresponding status. •• The row headers in the first column are as follows: – Switch Port—on card processor's connection to the switch on the SeRF card – Craft Port—on card processor's connection to the PHY port labeled Craft – OptEnetPort1-8—Ethernet switch interface to SFP 1-8 – Network Port—Ethernet switch interface to on-card processor – Management Port—switch interface to the PHY port labeled Network •• The column headers, from left to right, are as follows: – Rx Bytes—Receive byte counter. Increments by the byte count of frames received, including those in bad packets, excluding preamble and SFD but including FCS bytes – Rx Pkts—Receive packet counter. Increments for each frame received packet (including bad packets, all unicast, broa…
Text truncated - open the document above for the full version.
Mailing Address: P.O. Box 1101, Minneapolis, Minnesota 55440-1101 World Headquarters: Minneapolis, Minnesota USA +1.952.938.8080 www.adc.com May 10, 2010 Attn: Application Examiner, Reviewing Engineer FCC ID: F8I-PRSM070C Re: Request of Confidentiality Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying as outlined below: Schematics, Technical Description or Theory of Operation, Bill of Materials (BOM’s), and Block Diagrams The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this Application. Sincerely, Joshua J. Wittman Compliance Engineer Tele: 952 403-8322 Fax: 952 403-8858 Email: [email protected]
FlexWave™ PRISM Remote Unit Right View FlexWave™ PRISM Remote Unit Left View FlexWave™ PRISM Remote Unit Rear View FlexWave™ PRISM Remote Unit Top View FlexWave™ PRISM Remote Unit Bottom View FlexWave™ PRISM Remote Unit Open View
INFORMATION ON THIS DOCUMENT IS PROPRIETARY TO ADC AND SHALL NOT BE USED, COPIED, REPRODUCED OR DISCLOSED IN WHOLE OR IN PART WITHOUT WRITTEN CONSENT OF ADC TITLE FlexWave™ Prism – 700MHz Upper C Band FCC Identification Label TOLERANCE UNLESS .XX NA OTHERWISE SPECIFIED .XX NA DRAWING NUMBER None A REV DO NOT SCALE DRAWING ENGR. Joshua J. Wittman SIZE A SHEET 1 OF 1 REV ECO DWN DATE A JJW 5-10-2010 - See Note 4 for Model Number R.075 (4) DIE CUT LABEL XXXX-XXXXXXXX FCC ID: F8I-PRSM070C 2 1.500 REF .750 REF 1,4 NOTES: 1 PRINTING TYPE: TRANSFER METHOD. COLOR: BLACK TEXT 8 PT ARIAL NON-BOLD LOCATED APPROXIMATELY AS SHOWN. 2 PRINTING TYPE: TRANSFER METHOD. COLOR: BLACK TEXT 6 PT ARIAL NON-BOLD LOCATED APPROXIMATELY AS SHOWN. MATERIAL: ADC PART NUMBER 1215140 3 4 FWP-U416000MOD
FCC ID: F8I-PRSM070C FlexWave™ Prism - 700 Remote Unit Location of FCC ID Location of FCC Label
FlexWave™ URH Duplexer - Cellular Front View FlexWave™ URH Duplexer - Cellular Right View FlexWave™ URH Duplexer - Cellular Left View FlexWave™ URH Duplexer - Cellular Rear View FlexWave™ URH Duplexer - Cellular Bottom View
FlexWave™ URH LNA Top View FlexWave™ URH LNA Bottom View FlexWave™ URH Power Monitor Top View FlexWave™ URH Power Monitor Bottom View
FlexWave™ URH RDI Top View FlexWave™ URH RDI Top View – 1 FlexWave™ URH RDI Top View - 2 FlexWave™ URH RDI Bottom View FlexWave™ URH RDI Bottom View - 1 FlexWave™ URH RDI Bottom View - 2
FlexWave™ URH DART Top View FlexWave™ URH DART Top View – 1 FlexWave™ URH DART Top View - 2 FlexWave™ URH DART Bottom View FlexWave™ URH DART Bottom View - 1 FlexWave™ URH DART Bottom View - 2
FlexWave™ URH RSI Top View FlexWave™ URH RSI Bottom View
FlexWave™ URH SERF Top View FlexWave™ URH SERF Top View – 1 FlexWave™ URH SERF Top View - 2 FlexWave™ URH SERF Top View – 3 FlexWave™ URH SERF Top View - 4 FlexWave™ URH SERF Bottom View FlexWave™ URH SERF Bottom View - 1 FlexWave™ URH SERF Bottom View - 2 FlexWave™ URH SERF Bottom View – 3 FlexWave™ URH SERF Bottom View - 4
FlexWave™ URH Power Supply Top View FlexWave™ URH Power Supply Bottom View
Mailing Address: P.O. Box 1101, Minneapolis, Minnesota 55440-1101 World Headquarters: Minneapolis, Minnesota USA +1.952.938.8080 www.adc.com May 10, 2010 Attn: Application Examiner, Reviewing Engineer Re: Tune-up Procedure The FlexWave™ Prism – 700MHz Upper C - Band model number FWP-U416000MOD employs a solid-state design that does not require a tune-up procedure. Sincerely, Joshua J. Wittman Compliance Engineer Tele: 952 403-8322 Fax: 952 403-8858 Email: [email protected]
TEST DATA Test Data Number: 100099259MIN-001 Project Number: G100099259 Testing performed on the Prism Module, 700MHz Upper C-Band to 47 CFR, Part 27:2009 For ADC Telecommunications Inc. Test Performed by: Test Authorized by: Intertek Testing Services NA, Inc. 7250 Hudson Blvd., Suite 100 Oakdale, MN 55128 ADC Telecommunications Inc. PO. BOX 1101 Minneapolis, MN 55440-1101 Prepared by: Date: April 27, 2010 Uri Spector Reviewed by: Date: April 27, 2010 Norman Shpilsher EMC Test Data No: 100099259MIN-001 Page 2 of 17 TABLE OF CONTENTS 1.0 DESCRIPTION OF THE SAMPLE (EUT)............................................................ 3 2.0 TEST SUMMARY.......................................................................................... 4 2.1 Statement of the Measurement Uncertainty.......................................................... 4 3.0 TEST RESULTS........................................................................................... 5 3.1 Environmental conditions................................................................................ 14 5.0 TEST EQUIPMENT.......................................................................................16 ANNEX 1: ANTENNA CONDUCTED EMISSIONS........................................................17 EMC Test Data No: 100099259MIN-001 Page 3 of 17 1.0 DESCRIPTION OF THE SAMPLE (EUT) Model: Prism Module, 700MHz Upper C-Band, FWP-U416000MOD Type of EUT: Indoor / Outdoor Repeater Serial Number: N/A Company: ADC Telecommunications Inc. Customer: Mr. Joshua Wittman Address: ADC Telecommunications Inc. PO. Box 1101 Minneapolis, MN 55440-1101 Phone: 952-403-8322 Fax: Test Standards: EN 55022:2006 +A1:2007, Class EN 55011:2007, Group , Class 47 CFR, Part 27:2009 EN 55014-1:2006 EN 61326-1:2006 Class for Radiated and Conducted Emissions EN 60601-1-2:2001 +A1:2006 Class Radiated and Conducted Emissions EN 61000-6-3:2007 EN 61000-6-4:2007 EN 61000-3-2:2006 EN 61000-3-3:1995 +A1:2001 +A2:2006 Other EMC Test Data No: 100099259MIN-001 Page 4 of 17 2.0 TEST SUMMARY Referring to the performance criteria and the operating mode during the tests specified in this report, the equipment complies with the requirements according to the following standards. TEST STANDARD TEST RESULT Part 27 Spurious Enclosure Radiated Emissions Pass 2.1 Statement of the Measurement Uncertainty Note: The measured result in this report is within the specification limits by more than the measurement uncertainty; the measured result indicates that the product tested complies with the specification limit. The expanded uncertainty (k = 2) for radiated emissions from 30 to 1000 MHz has been determined to be: ±4 dB at 10m and ±5.4 dB at 3m The expanded uncertainty (k = 2) for conducted emissions from 150 kHz to 30 MHz has been determined to be: ±2.6 dB General notes: 1. Test was performed with the EUT tuned to the low frequency (747MHz), middle frequency (751MHz), and upper frequency (755MHz) of the operating band. 2. Testing was performed in frequency range from 30MHz to 8GHz. EUT tuned frequencies 747MHz, 751MHz, and 755MHz were excluded form the table 2. 3. The Spurious Radiated Power limits of -13dBm was correlated with field strength reference level of 82.2dBμV/m during field strength measurements at 3m measurement distance EMC Test Data No: 100099259MIN-001 Page 5 of 17 3.0 TEST RESULTS Tables 1-2 show detected Radiated Emissions. Graphs 1 to 18 show the EUT peak Radiated Emissions. No emissions were chosen for substitution measurements as the maximum emission is more than 20dB below the reference limit. EMC Test Data No: 100099259MIN-001 Page 6 of 17 TILE Instrument Control System EMI Measurement Software Radiated Emissions from 30MHz to 1GHzDate:04-27-2010 Company: ADC Telecommunications Inc. Model:Prism Module, 700MHz Upper C-Band Test Engineer: Uri Specto r Standard: FCC Part 27 Test Site: 3m Anechoic Chamber, 3m measurement distance Note:The table shows the worst case radiated emissions Measurements were taken usin g a Peak detector Table # 1 FrequencyAnt.Peak ReadingAnt.Factor Total at 3mQP LimitMargin PolaritydBμVdB1/mdBμV/mdBμV/mdB Operating Frequency 747MHz 30.047 MHzV20.720.741.482.2-40.8 41.161 MHzV29.714.944.682.2-37.6 337.82 MHzV25.916.842.682.2-39.6 937.89 MHzV23.325.348.682.2-33.6 167.08 MHzH34.211.545.782.2-36.5 437.76 MHzH22.619.642.282.2-40.0 525.08 MHzH21.120.841.982.2-40.3 937.89 MHzH18.225.343.482.2-38.8 Operating Frequency 751MHz 30.814 MHzV17.620.337.982.2-44.3 41.199 MHzV25.714.940.682.2-41.6 437.81 MHzV19.919.639.582.2-42.7 937.8 MHzV21.025.346.382.2-35.9 950.02 MHzV18.625.343.982.2-38.3 30.084 MHzH15.320.736.082.2-46.2 166.35 MHzH29.811.641.482.2-40.8 437.81 MHzH20.719.640.382.2-41.9 937.8 MHzH17.925.343.282.2-39.0 Operating Frequency 755MHz 30.842 MHzV21.120.341.482.2-40.8 41.171 MHzV30.714.945.682.2-36.6 48.154 MHzV33.611.244.882.2-37.4 937.8 MHzV23.425.348.782.2-33.5 950.02 MHzV18.525.343.882.2-38.4 167.39 MHzH34.811.546.382.2-36.0 525.21 MHzH21.020.841.882.2-40.4 687.45 MHzH19.523.142.682.2-39.6 937.8 MHzH18.725.344.082.2-38.2 EMC Test Data No: 100099259MIN-001 Page 7 of 17 TILE Instrument Control System EMI Measurement Software Radiated Emissions from 1GHz to 8GHzDate: 04-27-2010 Company: ADC Telecommunications Inc. Model: Prism Module, 700MHz Upper C-Band Test Engineer: Uri Spector Standard: FCC Part 27 Test Site: 3m Anechoic Chamber, 3m measurement distance Note: The table shows the worst case radiated emissions All measurements were taken usin g a Peak detector Table # 2 FrequencyAntennaReadingTotal C.F.Pre-Amp.Total at 3mQP LimitMargin MHzPolaritydBμVdB1/mGain (dB)dBμV/mdBμV/mdB Operating Frequency 747MHz 1.2485 GHzV65.726.942.650.082.2-32.2 1.4935 GHzV71.527.942.756.682.2-25.6 2.2425 GHzV66.830.743.254.382.2-27.9 7.349 GHzV41.142.041.241.882.2-40.4 1.0735 GHzH51.526.242.535.282.2-47.0 1.1855 GHzH58.626.642.542.782.2-39.5 1.2485 GHzH67.826.942.652.182.2-30.1 1.5005 GHzH58.627.942.743.882.2-38.4 2.463 GHzH54.231.443.142.582.2-39.7 7.4365 GHz…
Text truncated - open the document above for the full version.
6/2/10 FCC Part 27.53 (f) Prism 700 MHz Upper C Band (f) For operations in the 746-763 MHz, 775-793 MHz, and 805-806 MHz bands, emissions in the band 1559-1610 MHz shall be limited to -70 dBW/MHz equivalent isotropically radiated power (EIRP) for wideband signals, and -80 dBW EIRP for discrete emissions of less than 700 Hz bandwidth. For the purpose of equipment authorization, a transmitter shall be tested with an antenna that is representative of the type that will be used with the equipment in normal operation. In accordance to FCC 27.53 (f), the 700 MHz Upper C‐Band Module FWP‐U416000MOD was injected with a full rated signal at 751 MHz with the following modulations. LTE 1.4 MHz Channel Bandwidth LTE 3 MHz Channel Bandwidth LTE 5 MHz Channel Bandwidth LTE 10 MHz Channel Bandwidth The LTE 10 MHz Channel Bandwidth modulation was monitored as the “worst case” and is recorded in the plot below. It shows an emissions level of ‐56.70dBm (‐86.70 dBW) at 1559 ‐ 1610 MHz. LTE 10MHz Channel Bandwidth emissions at 1559 – 1610 MHz Joshua J. Wittman Compliance Engineer Tele: 952 403‐8322 Fax: 952 403‐8858 Email: [email protected]
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 4 | 27 | 746 MHz - 756 MHz | 43.78 W | 10M0D7D | 1.5 ppm |

FWP-T4MT000MOD-L
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FWP-W4MT000MOD
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FWP-44MT000MOD
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FWP-84MTA4MMOD
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FlexWave Prism HDM 850 MHz MIMO
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)