Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Dual-Band Dual-Slot RF Module Single-Slot RF Module Legacy Dual-Slot 40W RF Module HDM RF Module FlexWave Prism ™ Remote Unit RF Module Installation Guide TECP‐77‐141 ∙ Issue 6 ∙ April 2014 © 2014 TE Connectivity, Inc. All Rights Reserved. Information contained in this document is company private to TE Connectivity Ltd., and shall not be modified, used, copied, reproduced or disclosed in whole or in part without the written consent of TE. FlexWave, FlexWave Prism, InterReach Spectrum, InterReach Unison, Universal Radio Head, TE Co nnectivity, and TE connectivity (logo) are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. Contents herein are current as of the date of publication. TE reserves the right to change the contents without prior notice. In no event shall TE be lia ble for any damages resulting from loss of data, loss of use, or loss of profits, and TE further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. DOCUMENT OVERVIEW This manual provides the information you need to install TE Connectivity FlexWave Prism ® RF Modules into a Prism Remote Unit (PRU). Installation instructions are provided for the following Prism Remote Unit RF Modules: •Single‐Bay R F Modules, which includes the HDM RF Modules •Dual‐Bay RF Modules –Dual‐Band RF Modules –Legacy 40W RF Modules. Page 2FlexWave Prism Remote Unit RF Module Installation Guide ©2014 TE Connectivity Ltd.TECP‐77‐141 Issue 6 • 300001744178 Rev F • April 2014 Table 1 lists the RF Modules that this installation guide supports. The RF Modules are compatible only with the Remote Units listed in Table 2 on page 3. Table 1. FlexWave Prism RF Modules Supported in this Installation Guide Catalog NumberDescription High‐Density Module (HDM); Single Bay FWP‐441T841MODDUAL 20W SMR800 / PCS1900 FWP‐8416000MOD20W PCS Module, Non‐Diversity, HDM, Single Bay FWP‐84MT000MODDual 20W 1900 PCS, RF Module, MIMO, Single‐Bay FWP‐881T000MODHDM PCS Band 2 & 25 40W SISO, Single‐Bay FWP‐A416000MOD20W AWS Module, Non‐Diversity, HDM, Single Bay FWP‐A4MT000MODHDM AWS Band 4 MIMO 20W, Single‐Bay FWP‐A81T000MODHDM AWS Band 4 SISO 40W RF Module, Single‐Bay FWP‐B410000MOD20W WIDEBAND Cell Module, Non‐Diversity, Classic FWP‐B810100MOD40W WIDEBAND Cell Module, Non‐Diversity, Single‐Bay FWP‐C4MT000MODDUAL 20W 850 Cell/1900 PCS, Module, Single‐Bay FWP‐L4MT000MOD20W 700 lABC Module, MIMO HDM, Single‐Bay FWP‐L4MTU4MMODDual 20W 700 lABC/700uC, RF Module, Single‐Bay FWP‐U4MT000MOD20W 700 uC Module, MIMO HDM, Single‐Bay Single SuperDART; Single Bay FWP‐6216000MOD10W, EGSM 900, Non‐Diversity, Single SuperDART FWP‐7416000MOD20W, GSM 1800, Non‐Diversity, Single SuperDART FWP‐9416000MOD20W, UMTS 2100, Non‐Diversity, Single SuperDART FWP‐9416D00MOD20W 2100 UMTS Module, DIV Ready, Single SuperDART FWP‐F216000MOD10W APAC EGSM (885‐915) Module, Single SuperDART FWP‐I210000MOD6.5W APAC iDEN Module, Non‐Diversity, Classic (Extended 1 MHz) FWP‐K216000MOD10W 900 P‐GSM Module, Non‐Diversity, Single SuperDART FWP‐L416000MOD20W 700 Lower ABC Module, Non‐Diversity, Single SuperDART FWP‐U416000MOD700 LTE, UPPER C, 20W Module, SISO, Single SuperDART FWP‐U816100MOD40W 700 Upper C Module, Non‐Diversity, Single SuperDART, Single‐Bay Dual SuperDART; Single Bay FWP‐741S000MOD20W, GSM 1800, Non‐Diversity, DL SuperDART FWP‐841S000MOD20W RF Module, PCS 1900 12S FWP‐941S000MOD20W, UMTS 2100, Non‐Diversity, DL SuperDART FWP‐A41S000MOD20W RF Module, AWS 2100 12S Two Single SuperDARTs; Single Bay FWP‐6226000MOD10W, EGSM 900, Diversity, Single SuperDART FWP‐7426000MOD20W, GSM 1800, Diversity, Single SuperDART FWP‐8426000MOD20W PCS Module, Diversity, Single SuperDART FWP‐9426000MOD20W, UMTS 2100, Diversity, Single SuperDART FWP‐A426000MOD20W AWS Module, Diversity, Single SuperDART FWP‐K226000MOD10W 900 P‐GSM Module, Diversity, Single SuperDART FlexWave Prism Remote Unit RF Module Installation GuidePage 3 TECP‐77‐141 Issue 6 • 300001744178 Rev F • April 2014©2014 TE Connectivity Ltd. Revision History This release of the FlexWave Prism Remote Unit RF Module Installation Guide, TECP‐77‐141 Issue 6, adds support for the DUAL 20W SMR800 / PCS1900 RF Module (FWP‐441T841MOD). Document Cautions and Notes Two types of messages, identified below, appear in the text: CAUTION! Cautions indicate operations or steps that could cause personal injury, induce a safety problem in a managed device, destroy or corrupt information, or interrupt or stop services. NOTE:Notes contain information about special circumstances. Classic DART; Single Bay FWP‐4 210000MOD6.5W 800 SMR Module, Non‐Diversity, Classic FWP‐8 410000MOD20W RF Module, PCS 1900 Non‐Diversity FWP‐A 410000MOD20W RF Module, AWS 2100 Non‐Diversity FWP‐B420000MOD20W WID EBAND Cell Module, Diversity, Classic FWP‐8 420000MOD20W RF Module, PCS 1900 Diversity FWP‐A 420000MOD20W RF Module, AWS 2100 Diversity Classic DART; Two‐Bay FWP‐8 810000MOD40W PCS Module, Non‐Diversity, Classic (Dual‐Bay) FWP‐A 810000MOD40W AWS Module, Non‐Diversity, Classic, Dual‐Bay Dual Classic DART; Two‐Bay FWP‐D210 000MOD6.5W 800/900 ESMR Module, Non‐Diversity, Classic Table 2. Supported FlexWave Prism Remote Unit Chassis Catalog NumberDescription Single‐Bay Pr ism Remote Dual‐Ba y Prism Remote Tri‐Bay Pr ism Remote Quad‐Ba y Prism Remote FP1‐XXXXXXXXXXXRU FP2‐X XXXXXXXXXXRU FP3‐X XXXXXXXXXXRU FP4‐X XXXXXXXXXXRU Table 1. FlexWave Prism RF Modules Supported in this Installation Guide (Cont.) Catalog NumberDescription Page 4FlexWave Prism Remote Unit RF Module Installation Guide ©2014 TE Connectivity Ltd.TECP‐77‐141 Issue 6 • 300001744178 Rev F • April 2014 Abbreviations Used in this Guide CDRHCenter for Diseases and Radiological HealthLVDSLow‐Voltage Differential Signaling cmCentimeterMHzMegahertz DARTDigital Analog RF TransportMIMOMultiple‐Input Mul…
Text truncated - open the document above for the full version.
WTD 13.4.9 FCC Compliance Opinion TECO0013 Information about the Applicant Grantee (Company Name) ADC Telecommunications Inc. FCC Contact Person Joshua Wittman Address 1187 Park Place City, State, Zip Shakopee, MN 55379 Job Number TECO0013 Model FWP-441T841MOD FCC ID F8I-PSM8019D Agent Approval Type Original Equipment Class B2I – Part 20 Industrial Booster (CMRS) Rule Part 24E, 90S Overview The FlexWave PRISM, HDM 20W 800/1900 MHz, in its most basic configuration, serves as a transport between an FCC approved base station and a remote antenna. The system consists of two units; a “host”, that is co-located with the base station, and a “remote”, that resides at the location of the antenna. Both units perform wide band digitization, fiber optic transport, and reconstruction of the RF signal. In addition to RF transport, Flexwave PRISM also provides 10/100bT Ethernet connectivity between the host and all connected remotes. The host device is designed for in internal environment and is DC powered. The remote unit is designed for external environment and is AC powered. The entire system is monitored and controlled via an onboard web server that is accessible with a standard web browser. This device is not a consumer product and must be installed by qualified installers. Confidentiality is requested for allowed files. Request is properly addressed and referenced. Recommendation All items have been resolved and completed to my satisfaction; therefore I recommend this application for approval. Signature Dave Tolman, TCB Committee 5/1/2014
Mailing Address: 1187 Park Place, Shakopee, Minnesota 55379 www.te.com April 21, 2014 Attention: Reviewing Engineering Type of Certification: Original - FCC Part 90 and Part 24 Applicant: ADC Telecommunications Inc. Equipment: FlexWave™ Prism – HDM 20 Watt 800/1900 MHz Model #: FWP-441T841MOD FCC ID: F8I-PSM8019D Dear Sir/Madam: Enclosed please find a signed FR410 TCB Application for certification of the above mentioned RF module. Further details and supporting documents have been uploaded to the Northwest EMC CTS system. Should you have any questions, please feel free to contact the undersigned. Sincerely, Joshua J. Wittman Compliance Engineer Tele: 952 403-8322 Fax: 952 403-8858 Email: [email protected]
1(1) Attention: Application Examiner Re: Request for Confidentiality Applicant: ADC Telecommunications, Inc. FCC ID: F8I-PSM8019D To whom it may concern, Permanent Confidentiality Request is hereby submitted by ADC Telecommunications, Inc. to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential: • Schematics • Detailed Block diagrams • Detailed Operational/Functional Description Rationale for request for confidentiality: ADC Telecommunications, Inc. has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. The fee for confidentiality has been submitted along with the fee for certification. If you have questions or need further information, please contact the undersigned. Sincerely, Joshua J. Wittman Compliance Engineer ADC Telecommunications, Inc.
FWP-441T841MOD External Photos RF Module Assembly #1 FCC/IC Label Location FWP-441T841MOD External Photos RF Module Assembly #2 FWP-441T841MOD External Photos RF Module Assembly #3 Location of “Industrial Signal Booster Warning Label” FWP-441T841MOD External Photos RF Module Assembly #4 FWP-441T841MOD External Photos RF Module Assembly #5 FWP-441T841MOD External Photos RF Module Assembly #6 FCC/IC Label Location FWP-441T841MOD External Photos RF Module Assembly #7 FWP-441T841MOD External Photos RF Module Assembly #8
FCC ID and Industrial Booster Warning Label Location on Chassis Industrial Booster Label Chassis Location FCC/IC Label Chassis Location
INFORMATION ON THIS DOCUMENT IS PROPRIETARY TO ADC AND SHALL NOT BE USED, COPIED, REPRODUCED OR DISCLOSED IN WHOLE OR IN PART WITHOUT WRITTEN CONSENT OF ADC TITLE FlexWave™ Prism – HDM 20W 800/1900 MHz FCC/IC Identification Label TOLERANCE UNLESS .XX NA OTHERWISE SPECIFIED .XX NA DRAWING NUMBER None A REV DO NOT SCALE DRAWING ENGR. Joshua J. Wittman SIZE A SHEET 1 OF 1 REV ECO DWN DATE A JJW 4-22-2014 Model: FWP-441T841MOD FCC: F8I-PSM8019D IC: 1208G-PSM8019D 2 1.500 REF R.075 (4) DIE CUT LABEL .750 REF 1 NOTES: 1 PRINTING TYPE: TRANSFER METHOD. COLOR: BLACK TEXT 8 PT ARIAL NON-BOLD LOCATED APPROXIMATELY AS SHOWN. 2 PRINTING TYPE: TRANSFER METHOD. COLOR: BLACK TEXT 6 PT ARIAL NON-BOLD LOCATED APPROXIMATELY AS SHOWN. MATERIAL: ADC PART NUMBER 1215140 3 RF Module Assembly #1 FCC/IC Label Module Location
Motherboard – Front #1 Motherboard – Front #2 Motherboard – Front #3 Motherboard – Back #1 Motherboard – Back #2 Motherboard – Back #3 Tx Board – Front Tx Radio Tx Board – Back Rx Board – Front Rx Board – Back Duplexer #1 Duplexer #2 Antenna port Duplexer #3 LPA #1 LPA #2 LPA #3
Mailing Address: 1187 Park Place, Shakopee, Minnesota 55379 www.te.com April 22, 2014 Antenna Information Attention: Reviewing Engineering Type of Certification: Original - FCC Part 90 and 24 Applicant: ADC Telecommunications, Inc. Equipment: FlexWave™ Prism – HDM 20 Watt 800/1900 MHz Model #: FWP-441T841MOD FCC ID: F8I-PSM8019D Dear Sir/Madam: We, ADC Telecommunications, Inc. do not manufacture or distribute any antennas to our customers for their deployments. The customer provides their own. Dipole and omni antennas with a typical gain of 6dBi will be used with this product. Further details and supporting documents have been uploaded to the Northwest EMC CTS system. Should you have any questions, please feel free to contact the undersigned. Sincerely, Joshua J. Wittman Compliance Engineer Tele: 952 403-8322 Fax: 952 403-8858 Email: [email protected]
Mailing Address: 1187 Park Place, Shakopee, Minnesota 55379 www.TE.com April 21, 2014 Attn: Application Examiner, Reviewing Engineer Re: Tune-up Procedure The FlexWave™ Prism – HDM 20 Watt 800/1900 MHz model number FWP-441T841MOD employs a solid-state design that does not require a tune-up procedure. Sincerely, Joshua J. Wittman Compliance Engineer Tele: 952 403-8322 Fax: 952 403-8858 Email: [email protected]
Mailing Address: P.O. Box 1101, Minneapolis, Minnesota 55440-1101 World Headquarters: Minneapolis, Minnesota USA +1.952.938.8080 www.adc.com April 21, 2014 Attn: Application Examiner, Reviewing Engineer Re: RF Exposure Statement The antenna(s) used for this transmitter must be fixed-mounted on (outdoor/indoor) structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 47 CFR 1.1307 (b)(3) Sincerely, Joshua J. Wittman Compliance Engineer Tele: 952 403-8322 Fax: 952 403-8858 Email: [email protected]
TE Connectivity / ADC Telecommunications Prism HDM 800 MHz/1900 MHz SISO RF Module FCC 24E:2014 Report #: TECO0013.2 Report Prepared By Northwest EMC Inc. NORTHWEST EMC – (888) 364-2378 – www.nwemc.com California – Minnesota – Oregon – New York – Washington WTD 12.5.23 CERTIFICATE OF TEST Last Date of Test: April 16, 2014 TE Connectivity / ADC Telecommunications Model: Prism HDM 800 MHz/1900 MHz SISO RF Module Emissions Test Description Specification Test Method Pass/Fail Output Power FCC 24E:2013, FCC 2.1046:2013 ANSI/TIA/EIA-603-C-2004 Pass Band Edge Compliance FCC 24E:2013, FCC 2.1051:2013 ANSI/TIA/EIA-603-C-2004 Pass Out of Band Emissions –Conducted FCC 24E:2013, FCC 2.1051:2013 ANSI/TIA/EIA-603-C-2004 Pass Intermodulation FCC 24E:2013, FCC 2.1051:2013 ANSI/TIA/EIA-603-C-2004 Pass Frequency Stability FCC 24E:2013, FCC 2.1055:2013 ANSI/TIA/EIA-603-C-2004 Pass Occupied Bandwidth FCC 24E:2013, FCC 2.1049:2013 ANSI/TIA/EIA-603-C-2004 Pass Field Strength of Spurious Emissions FCC 24E:2013, FCC 2.1053:2013 ANSI/TIA/EIA-603-C-2004 Pass Peak to Average Ratio FCC 24E:2013, FCC 2.1046:2013 ANSI/TIA/EIA-603-C-2004 Pass Deviations From Test Standards None Approved By: Tim O'Shea, Operations Manager NVLAP Lab Code: 200881-0 This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government of the United States of America. Product compliance is the responsibility of the client, therefore the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. This Report may only be duplicated in its entirety. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. REV 2012.08.02 REVISION HISTORY Revision Number Description Date Page Number 00 None Barometric Pressure The recorded barometric pressure has been normalized to sea level. REV 2012.05.24 ACCREDITATIONS AND AUTHORIZATIONS United States FCC - Designated by the FCC as a Telecommunications Certification Body (TCB). Certification chambers, Open Area Test Sites, and conducted measurement facilities are listed with the FCC. A2LA - Accredited by A2LA to ISO / IEC Guide 65 as a product certifier. This allows Northwest EMC to certify transmitters to FCC and IC specifications. NVLAP - Each laboratory is accredited by NVLAP to ISO 17025 Canada IC - Recognized by Industry Canada as a Certification Body (CB). Certification chambers and Open Area Test Sites are filed with IC. European Union European Commission – Validated by the European Commission as a Conformity Assessment Body (CAB) under the EMC directive and as a Notified Body under the R&TTE Directive. Australia/New Zealand ACMA - Recognized by ACMA as a CAB for the acceptance of test data. Korea KCC / RRA - Recognized by KCC’s RRA as a CAB for the acceptance of test data. Japan VCCI - Associate Member of the VCCI. Conducted and radiated measurement facilities are registered. Taiwan BSMI – Recognized by BSMI as a CAB for the acceptance of test data. NCC - Recognized by NCC as a CAB for the acceptance of test data. Singapore IDA – Recognized by IDA as a CAB for the acceptance of test data. Hong Kong OFTA – Recognized by OFTA as a CAB for the acceptance of test data. Vietnam MIC – Recognized by MIC as a CAB for the acceptance of test data. Russia GOST – Accredited by Certinform VNIINMASH, CERTINFO, SAMTES, and Federal CHEC to perform EMC and Hygienic testing for Information Technology products to GOST standards. SCOPE For details on the Scopes of our Accreditations, please visit: http://www.nwemc.com/accreditations/ REV 2013.03.8 MEASUREMENT UNCERTAINTY Measurement Uncertainty When a measurement is made, the result will be different from the true or theoretically correct value. The difference is the result of tolerances in the measurement system that cannot be completely eliminated. To the extent that technology allows us, it has been our aim to minimize this error. Measurement uncertainty is a statistical expression of measurement error qualified by a probability distribution. A measurement uncertainty estimation has been performed for each test per our internal quality document WP 342. The estimation is used to compare the measured result with its "true" or theoretically correct value. The expanded measurement uncertainty (K=2) for each test is listed below. Our measurement data meets or exceeds the measurement uncertainty requirements of the applicable specification; therefore, the test data can be compared directly to the specification limit to determine compliance. The calculations for estimating measurement uncertainty are based upon ETSI TR 100 028 (or CISPR 16-4-1 as applicable), and are available upon request. The following table represents the Measurement Uncertainty (MU) budgets for each of the tests that may be contained in this report. Test + MU - MU Frequency Accuracy (Hz) 0.12 -0.01 Amplitude Accuracy (dB) 0.49 -0.49 Conducted Power (dB) 0.41 -0.41 Radiated Power via Substitution (dB) 0.69 -0.68 Temperature (degrees C) 0.81 -0.81 Humidity (% RH) 2.89 -2.89 Field Strength (dB) 3.80 -3.80 AC Powerline Conducted Emissions (dB) 2.94 -2.94 REV 2013.06.28 FACILITIES Oregon Labs EV01-12 22975 NW Evergreen Pkwy Hillsboro, OR 97124 (503) 844-4066 California Labs OC01-13 41 Tesla Irvine, CA 92618 (949) 861-8918 New York Labs NY01-04 4939 Jordan Rd. Elbridge, NY 13060 (315) 685-0796 Minnesota Labs MN01-08 9349 W Broadway Ave. Brooklyn Park, MN 55445 (763) 425-2281 Washington Labs NC01-05,SU02,SU07 19201 120 th Ave. NE Bothell, WA 98011 (425) 984-6600 VCCI A-0108 A-0029 A-0109 A-0110 Industry Canada 2834D-1, 2834D-2 2834B-1, 2834B-2, 2834B-3 2834E-1 2834F-1 NVLAP NVLAP Lab Code: 200630-0 NVLAP Lab Code: 200676-0 NVLAP Lab Code: 200761-0 NVLAP Lab Code: 200881-0 NVLAP Lab Code: 200629-0 WTD 12.5.23 PRODUCT DESCRIPTION Client and Equipment Under T…
Text truncated - open the document above for the full version.
TE Connectivity / ADC Telecommunications Prism HDM 800 MHz/1900 MHz SISO RF Module FCC 90I:2014 Report #: TECO0013.1 Report Prepared By Northwest EMC Inc. NORTHWEST EMC – (888) 364-2378 – www.nwemc.com California – Minnesota – Oregon – New York – Washington WTD 12.5.23 CERTIFICATE OF TEST Last Date of Test: April 16, 2014 TE Connectivity / ADC Telecommunications Model: Prism HDM 800 MHz/1900 MHz SISO RF Module Emissions Test Description Specification Test Method Pass/Fail Conducted Output Power FCC 90I:2014 ANSI/TIA/EIA-603-C-2004 Pass Out of Band Emissions –Conducted FCC 90I:2014 ANSI/TIA/EIA-603-C-2004 Pass Intermodulation FCC 90I:2014 ANSI/TIA/EIA-603-C-2004 Pass Frequency Stability FCC 90I:2014 ANSI/TIA/EIA-603-C-2004 Pass Occupied Bandwidth FCC 90I:2014 ANSI/TIA/EIA-603-C-2004 Pass Field Strength of Spurious Emissions FCC 90I:2014 ANSI/TIA/EIA-603-C-2004 Pass Deviations From Test Standards None Approved By: Tim O'Shea, Operations Manager NVLAP Lab Code: 200881-0 This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government of the United States of America. Product compliance is the responsibility of the client, therefore the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. This Report may only be duplicated in its entirety. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. REV 2012.08.02 REVISION HISTORY Revision Number Description Date Page Number 00 None Barometric Pressure The recorded barometric pressure has been normalized to sea level. REV 2012.05.24 ACCREDITATIONS AND AUTHORIZATIONS United States FCC - Designated by the FCC as a Telecommunications Certification Body (TCB). Certification chambers, Open Area Test Sites, and conducted measurement facilities are listed with the FCC. A2LA - Accredited by A2LA to ISO / IEC Guide 65 as a product certifier. This allows Northwest EMC to certify transmitters to FCC and IC specifications. NVLAP - Each laboratory is accredited by NVLAP to ISO 17025 Canada IC - Recognized by Industry Canada as a Certification Body (CB). Certification chambers and Open Area Test Sites are filed with IC. European Union European Commission – Validated by the European Commission as a Conformity Assessment Body (CAB) under the EMC directive and as a Notified Body under the R&TTE Directive. Australia/New Zealand ACMA - Recognized by ACMA as a CAB for the acceptance of test data. Korea KCC / RRA - Recognized by KCC’s RRA as a CAB for the acceptance of test data. Japan VCCI - Associate Member of the VCCI. Conducted and radiated measurement facilities are registered. Taiwan BSMI – Recognized by BSMI as a CAB for the acceptance of test data. NCC - Recognized by NCC as a CAB for the acceptance of test data. Singapore IDA – Recognized by IDA as a CAB for the acceptance of test data. Hong Kong OFTA – Recognized by OFTA as a CAB for the acceptance of test data. Vietnam MIC – Recognized by MIC as a CAB for the acceptance of test data. Russia GOST – Accredited by Certinform VNIINMASH, CERTINFO, SAMTES, and Federal CHEC to perform EMC and Hygienic testing for Information Technology products to GOST standards. SCOPE For details on the Scopes of our Accreditations, please visit: http://www.nwemc.com/accreditations/ REV 2013.03.8 MEASUREMENT UNCERTAINTY Measurement Uncertainty When a measurement is made, the result will be different from the true or theoretically correct value. The difference is the result of tolerances in the measurement system that cannot be completely eliminated. To the extent that technology allows us, it has been our aim to minimize this error. Measurement uncertainty is a statistical expression of measurement error qualified by a probability distribution. A measurement uncertainty estimation has been performed for each test per our internal quality document WP 342. The estimation is used to compare the measured result with its "true" or theoretically correct value. The expanded measurement uncertainty (K=2) for each test is listed below. Our measurement data meets or exceeds the measurement uncertainty requirements of the applicable specification; therefore, the test data can be compared directly to the specification limit to determine compliance. The calculations for estimating measurement uncertainty are based upon ETSI TR 100 028 (or CISPR 16-4-1 as applicable), and are available upon request. The following table represents the Measurement Uncertainty (MU) budgets for each of the tests that may be contained in this report. Test + MU - MU Frequency Accuracy (Hz) 0.12 -0.01 Amplitude Accuracy (dB) 0.49 -0.49 Conducted Power (dB) 0.41 -0.41 Radiated Power via Substitution (dB) 0.69 -0.68 Temperature (degrees C) 0.81 -0.81 Humidity (% RH) 2.89 -2.89 Field Strength (dB) 3.80 -3.80 AC Powerline Conducted Emissions (dB) 2.94 -2.94 REV 2013.06.28 FACILITIES Oregon Labs EV01-12 22975 NW Evergreen Pkwy Hillsboro, OR 97124 (503) 844-4066 California Labs OC01-13 41 Tesla Irvine, CA 92618 (949) 861-8918 New York Labs NY01-04 4939 Jordan Rd. Elbridge, NY 13060 (315) 685-0796 Minnesota Labs MN01-08 9349 W Broadway Ave. Brooklyn Park, MN 55445 (763) 425-2281 Washington Labs NC01-05,SU02,SU07 19201 120 th Ave. NE Bothell, WA 98011 (425) 984-6600 VCCI A-0108 A-0029 A-0109 A-0110 Industry Canada 2834D-1, 2834D-2 2834B-1, 2834B-2, 2834B-3 2834E-1 2834F-1 NVLAP NVLAP Lab Code: 200630-0 NVLAP Lab Code: 200676-0 NVLAP Lab Code: 200761-0 NVLAP Lab Code: 200881-0 NVLAP Lab Code: 200629-0 WTD 12.5.23 PRODUCT DESCRIPTION Client and Equipment Under Test (EUT) Information Company Name: TE Connectivity / ADC Telecommunications Address: 1187 Park Place City, State, Zip: Shakopee, MN 55379 Test Requested By: Joshua Wittman Model: Prism HDM 800 MHz/1900 MHz SISO RF Module First Date of Test: April 09, 2…
Text truncated - open the document above for the full version.
OUTPUT POW ER XMit 2013.08.15 NORTHWEST OUTPUT POWER PsaTx 2013.10.23 EMC DIRECT 001.jpg DIRECT 002.jpg OUTPUT POWER BAND EDGE COMPLIANCE XMit 2013.08.15 NORTHWEST BAND EDGE COMPLI EMC DIRECT 001.jpg DIRECT 002.jpg BAND EDGE COMPLIANCE OUT OF BAND EMISSIONS -CONDUCTED XMit 2013.08.15 NORTHWEST OUT OF BAND EMISS PsaTx 2013.10.23 EMC DIRECT 001.jpg DIRECT 002.jpg OUT OF BAND EMISSIONS - CONDUCTED INTERMODULATION XMit 2013.08.15 NORTHWEST INTERMODULATION PsaTx 2013.10.23 EMC DIRECT 002.jpg DIRECT COMB 002.jpg INTERMODULATION FREQUENCY STABILITY XMit 2013.08.15 NORTHWEST FREQUENCY STABIL PsaTx 2013.10.23 EMC FSB 001.jpg FREQUENCY STABILITY OCCUPIED BANDWIDTH (26 dB) XMit 2013.08.15 NORTHWEST OCCUPIED BANDWID PsaTx 2013.10.23 EMC DIRECT 001.jpg DIRECT 002.jpg OCCUPIED BANDWIDTH (26 dB) photo SE 002.jpg SE 003.jpg FIELD STRENGTH OF SPURIOUS EMISSIONS PSA-ESCI 2014.02.19 PEAK TO AVERAGE RATIO XMit 2013.08.15 NORTHWEST PEAK TO AVERAGE R EMC DIRECT 001.jpg DIRECT 002.jpg PEAK TO AVERAGE RATIO
CONDUCTED OUTPUT POW ER XMit 2013.08.15 NORTHWEST CONDUCTED OUTPU PsaTx 2013.10.23 EMC DIRECT 001.jpg DIRECT 002.jpg CONDUCTED OUTPUT POWER OUT OF BAND EMISSIONS -CONDUCTED XMit 2013.08.15 NORTHWEST OUT OF BAND EMISS PsaTx 2013.10.23 EMC DIRECT 001.jpg DIRECT 002.jpg OUT OF BAND EMISSIONS - CONDUCTED INTERMODULATION XMit 2013.08.15 NORTHWEST INTERMODULATION EMC DIRECT 002.jpg DIRECT COMB 002.jpg INTERMODULATION FREQUENCY STABILITY XMit 2013.08.15 NORTHWEST FREQUENCY STABIL PsaTx 2013.10.23 EMC FSB 001.jpg FREQUENCY STABILITY OCCUPIED BANDWIDTH (26 dB) XMit 2013.08.15 NORTHWEST OCCUPIED BANDWID PsaTx 2013.10.23 EMC DIRECT 001.jpg DIRECT 002.jpg OCCUPIED BANDWIDTH (26 dB) photo SE 002.jpg SE 003.jpg FIELD STRENGTH OF SPURIOUS EMISSIONS PSA-ESCI 2014.02.19
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 6 | 90S | 862 MHz - 869 MHz | 24.95 W | 3M03G7D | 0.04 ppm |

FWP-T4MT000MOD-L
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FWP-W4MT000MOD
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FWP-44MT000MOD
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FWP-84MTA4MMOD
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FlexWave Prism HDM 850 MHz MIMO
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)