
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ADC FlexWave ® Prism Element Management System 7.1 User Manual D-620749-0-20 Rev A Antenna Antenna Antenna Quad Band Remote Unit Host Unit Antenna 77073-001 ADCP-77-177 Issue 1 July 2011 Copyright © 2011 ADC Telecommunications, Inc. All Rights Reserved. Information contained in this document is company private to ADC Telecommunications, Inc. and shall not be modified, used, copied, reproduced or disclosed in whole or in part without the written consent of ADC. Trademark Information ADC and FlexWave are registered trademarks, and InterReach Spectrum and Universal Radio Head are trademarks of ADC Telecommunications, Inc. No right, license, or interest to such trademarks is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark. Other product names mentioned in this practice are used for identification purposes only and may be trademarks or registered trademarks of their respective companies. Disclaimer of Liability Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. Should the content of printed user documentation shipped with product differ from documentation provided on a product CD (inclusive of the associated Help modules), the printed user documentation supersedes the documentation on the product CD. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits, and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. Specific Disclaimer for High-Risk Activities This Software Product is not specifically designed, manufactured, tested or intended for use in high-risk activities including, without restricting the generality of the foregoing, on-line control of aircraft, air traffic, aircraft navigation or aircraft communications; or in the design, construction, operation or maintenance of any nuclear facility. ADC (including its affiliates) and its suppliers specifically disclaim any express or implied warranty of fitness for such purposes or any other purposes. Screenshots in User Documentation Due to concurrent development of this documentation, artwork, and the FlexWave Prism EMS product, there may be some minor discrepancies between screenshots contained in this documentation and those actually displayed in the FlexWave Prism EMS. These discrepancies will generally be few and minor and should not affect your understanding of FlexWave Prism EMS. FlexWave Prism Element Management System 7.1 User ManualPage iii ADCP-77-177 • Issue 1 • July 2011©2011 ADC Telecommunications, Inc. TABLE OF CONTENTS Preface __________________________________________________________ix FlexWave Prism User Documentation ......................................................................................... x EMS Document Overview .........................................................................................................xi Document Cautions and Notes.............................................................................................xi Document Fonts ................................................................................................................xi Document Fonts ................................................................................................................xi Document Graphics .......................................................................................................... xii Abbreviations/Acronyms ........................................................................................................ xiii Part I: FlexWave Prism Hardware _______________________________ 1 Prism System Overview _____________________________________________ 3 Prism System Overview ...........................................................................................................4 Fiber Optic Transport..............................................................................................................10 Host Unit Overview ................................................................................................................11 Fan Module......................................................................................................................11 SeRF II Module ................................................................................................................12 SeRF II Module Ports ...................................................................................................12 SeRF II Module LEDs ...................................................................................................13 Host System II Module ......................................................................................................14 Host System II Module Ports and Connectors ..................................................................14 Host System II Module LEDs.........................................................................................15 DC Power Module .............................................................................................................15 Prism Remote Units................................................................................................................16 PRU Ports and Connectors (Bottom of PRU)..........................................................................17 PRU Status LED (Bottom of PRU) ........................................................................................18 PRU Components..............................................................................................................19 RF Module Capabilities and GUI Representation ....................................................................21 DART Modules .................................................…
Text truncated - open the document above for the full version.
Using the Prism EMS FlexWave Prism Element Management System 7.1 User ManualPage 45 ADCP-77-177 • Issue 1 • July 2011© 2011 ADC Telecommunications, Inc. Viewing Alarm Details In many instances, a page will have an Alarm Status column, which indicates whether an alarm is active. If an alarm is active, there will be a Minor or Major link (as shown in Figure 19) that you click to open a dialog that defines the active alarm. The background color of the Alarm Status cell also indicates the alarm level. Figure 19. Alarm Link For information on the Alarm indicator in the System Tree, see “System Tree” on page 41. How to Use the EMS Graphical User Interface Page 46FlexWave Prism Element Management System 7.1 User Manual © 2011 ADC Telecommunications, IncADCP-77-177 • Issue 1 • July 2011 Sorting Tables You can change the order of a table’s contents by applying an alphanumeric sort on a column (see Figure 20). To toggle a column by ascending or descending order, click in the column heading. Figure 20. Sorting Tables in the GUI Using the Prism EMS FlexWave Prism Element Management System 7.1 User ManualPage 47 ADCP-77-177 • Issue 1 • July 2011© 2011 ADC Telecommunications, Inc. FOLLOWING THE PROCEDURES IN THIS DOCUMENT This section tells you how to use this document to use the FlexWave Prism EMS to configure and manage Prism devices. Starting a Procedure All procedures in this document assume that you have already logged in to the EMS as described in “Access the EMS” on page 57. Modifying Parameters In general, the procedures in this document end by having you click OK or Apply to accept changes or input. When an operation completes, an Operation completed message displays, such as the one shown in Figure 21. If an error message displays, follow the screen prompts. You can click Refresh to update the data being shown. Figure 21. Operation Completed Message Following the Procedures in this Document Page 48FlexWave Prism Element Management System 7.1 User Manual © 2011 ADC Telecommunications, IncADCP-77-177 • Issue 1 • July 2011 Selecting Menu Items In the Prism user documentation, when a procedure requires that you select a sequence of menu items, a right-angle symbol separate the items. For example, in the following graphic, “click Users > Manage Users” indicates that in the System Menu bar you select Users, and then in the Users list, select Manage Users. Using the Prism EMS FlexWave Prism Element Management System 7.1 User ManualPage 49 ADCP-77-177 • Issue 1 • July 2011© 2011 ADC Telecommunications, Inc. USING THE HELP EMBEDDED IN THE GUI The following sections tell you how top access and use the embedded Prism Help module. Accessing Help In the Orientation Links, click Help > Contents. Prism Help is context sensitive, which means that the Help topic that opens will pertain to the current view in the EMS View Frame. In the following example, the Help Topic for the Get Information page has opened. Using the Help Embedded in the GUI Page 50FlexWave Prism Element Management System 7.1 User Manual © 2011 ADC Telecommunications, IncADCP-77-177 • Issue 1 • July 2011 Navigating Help The Help Module is designed like a book to make it easy to navigate. Using the Contents Tab The default view opens with the Contents navigation tool open. In the following example, you can see where the Get Information topic falls within the order of contents. •Click on any of the Contents links to go to the specified topic. •Click on the book icons to open/close the chapters. Using the Prism EMS FlexWave Prism Element Management System 7.1 User ManualPage 51 ADCP-77-177 • Issue 1 • July 2011© 2011 ADC Telecommunications, Inc. You can also use the Show in Contents button to show where a topic falls within the book hierarchy: Using the Orientation Links and Buttons You can use the interactive orientation links in the topic header. These links show where the topic falls within a chapter. Click on the links in the topic header to move back one step in the book hierarchy. Using the Help Embedded in the GUI Page 52FlexWave Prism Element Management System 7.1 User Manual © 2011 ADC Telecommunications, IncADCP-77-177 • Issue 1 • July 2011 You can also use the Page Up button, Page Down button, Print button, and Bookmark button to bookmark a topic. Using the Index Tab Click Index to open the Index panel. At the top of the Index panel is the alpha-numeric orientation tool. In this example, the letter D is selected, which results in only those indexed words that start with Using the Prism EMS FlexWave Prism Element Management System 7.1 User ManualPage 53 ADCP-77-177 • Issue 1 • July 2011© 2011 ADC Telecommunications, Inc. “D” to display, in alphabetic order. Click on any of the links to go to the topic that has the indexed term in it. To move up/down or left/right to change the orientation of the text in the Index panel, use the navigation arrows. Using the Search Tab 1Click Search to open the Search panel. 2At the top of the Search panel is a text box in which you enter the term for which you want to search. In this example the user is searching for the word “passband.” 3To activate the search, click the Go button. The Search panel is populated with links to the topics that contain the word “passband” and are ordered from top down in order of probability of which topic will contain the topic for which you are searching. Using the Help Embedded in the GUI Page 54FlexWave Prism Element Management System 7.1 User Manual © 2011 ADC Telecommunications, IncADCP-77-177 • Issue 1 • July 2011 Intentionally Blank Page FlexWave Prism Element Management System 7.1 User ManualPage 55 ADCP-77-177 • Issue 1 • July 2011©2011 ADC Telecommunications, Inc. INITIAL FLEXWAVE PRISM SYSTEM SETUP Minimum EMS System Requirements ........................................................................................56 Access the EMS .....................................................................................................................57 Set Ses…
Text truncated - open the document above for the full version.
Get Information Page 110FlexWave Prism Element Management System 7.1 User Manual © 2011 ADC Telecommunications, IncADCP-77-177 • Issue 1 • July 2011 Viewing the Alarms Report To access the Current Alarms report, in the System Menu bar, click System Information > Get Information, and then in the Reports panel Type list, select Alarms. The Current Alarms table provides the following information: •Severity—whether alarm is classified as Major or Minor. •Ack’d—whether the alarm has been acknowledged, as indicated by a checkmark. •Alarm Code—system-assigned alarm code. See “Troubleshooting Alarms” on page 185 or use the “Index of Alarms” on page 313 to find the page number for a specific alarm description, which includes the alarm code. •Alarm Name—descriptive name of alarm. •Timestamp—date and time when the alarm occurred (YYYY:MM:DD:HH:MM:SS) •Unit Id—identifies the unit within the system; see “Unit Identification” on page 43. •Unit Type—what the unit is, such as Host or Remote •Unit Name—name assigned to the unit •Module—type of module within the specified unit that is experiencing the alarm (SeRF, DART, Power Detector, SFP) •Module Name—user-assigned name for the module that assists in identifying modules when troubleshooting •RF Band—type of passband provided by the DART (if applicable) System Information FlexWave Prism Element Management System 7.1 User ManualPage 111 ADCP-77-177 • Issue 1 • July 2011© 2011 ADC Telecommunications, Inc. •Extended Info—link that provides further information on the alarm, including troubleshooting information. IFEU + RAU Report The IFEU + RAU report pertains to an InterReach Spectrum system and is not applicable to this release. Get Information Page 112FlexWave Prism Element Management System 7.1 User Manual © 2011 ADC Telecommunications, IncADCP-77-177 • Issue 1 • July 2011 Viewing the All Report The All Report consolidates all available reports into a single web page. System Information FlexWave Prism Element Management System 7.1 User ManualPage 113 ADCP-77-177 • Issue 1 • July 2011© 2011 ADC Telecommunications, Inc. Downloading a Report CAUTION!The All Report or Analog Units Report can take several minutes to download. You can download the reports to your laptop in Windows Excel format. Do the following to download a report to your computer: 1In the System Menu bar, click System Information > Get Information. 2On the Get Information page, in the Reports panel Type list, select the name of the report that you want to download. 3Click Download. 4In the File Download window, click Save. Get Information Page 114FlexWave Prism Element Management System 7.1 User Manual © 2011 ADC Telecommunications, IncADCP-77-177 • Issue 1 • July 2011 5In the Save As window, navigate to where you want the report file saved, and then click Save. The file is saved as specified. System Information FlexWave Prism Element Management System 7.1 User ManualPage 115 ADCP-77-177 • Issue 1 • July 2011© 2011 ADC Telecommunications, Inc. 6Go to the directory where the file was saved to open the file. NOTE:While Excel is often used to view this file, Excel uses characters such as hyphens and slashes to create formulas. If discrepancies are seen in this report, use a text editor to verify the report’s content. Get Optics Information Page 116FlexWave Prism Element Management System 7.1 User Manual © 2011 ADC Telecommunications, IncADCP-77-177 • Issue 1 • July 2011 GET OPTICS INFORMATION The Get Optics Information page allows you to view information on the fiber. To access the Get Optics Information page, in the System Menu bar, click System Information > Get Optics Information. The Filter panel has the following elements: •View list—allows you to select a filter to be applied to the page •contains box—allows you to enter filter criteria •Filter button—click to apply the filter The Get Optics Information table has the following elements: •Unit Type—whether the unit is a Host or Remote •Unit Name—user defined name of the unit •SFP Number—system assigned number (from 1 to 8) for the Optical ports •SFP Name—user entered port name or UNKNOWN_SFPNAME, which indicates that a name has not been entered. •Optics Type –LongRange—26 dB –IntermediateRange—18 dB). System Information FlexWave Prism Element Management System 7.1 User ManualPage 117 ADCP-77-177 • Issue 1 • July 2011© 2011 ADC Telecommunications, Inc. •Wavelength (nm)—number displayed is the wavelength transmitted through this port: – Non-duplex and WDM configurations 1550 nm fwd 1310 nm rev – CWDM configurations can be one of eight wavelengths: •Tx Power (dBm)—launch power level in dBm of forward path signal. The minimum FWD launch power is -2 dBm, and the maximum is 3 dBm. •Rx Power (dBm)—Receive power level in dBm of reverse path signal, which incorporates the launch power of the Remote Unit SFP plus all optical losses (insertion losses, fiber cable loss, and so forth). •Remote Name—name of the Remote connected to this Optics port. •Alarm Status—whether an alarm is active. If an alarm is active, there will be a Minor or Major link that you click to open a dialog that defines the active alarm, as described in “Viewing Alarm Details” on page 45. The background color of the Alarm Status cell also indicates the alarm level (see “Alarm Color Codes” on page 44). 1470 nm1550 nm 1490 nm1570 nm 1510 nm1590 nm 1530 nm1610 nm Get Logs Page 118FlexWave Prism Element Management System 7.1 User Manual © 2011 ADC Telecommunications, IncADCP-77-177 • Issue 1 • July 2011 GET LOGS The Get Logs page allows you to save compressed tar archive files of Prism logs.This feature is primarily used by ADC personnel when troubleshooting a system. However, you should know how to create a log so you can email the log to ADC if requested to do so. 1To access the Get Logs page, in the System Menu bar, click System Information > Get Logs. 2Click Get Logs. 3In the File Download dialog, click Save. System Information FlexWave Prism Element Management System 7.1…
Text truncated - open the document above for the full version.
Prism MIB Objects Page 288FlexWave Prism Element Management System 7.1 User Manual © 2011 ADC Telecommunications, IncADCP-77-177 • Issue 1 • July 2011 Alarm Enabled SNMP MIB: fwuSystemAlarmEnabled Description:Indicates whether the alarm is Enabled or Disabled Syntax:ALARMEnable Access Level:Read Write Static Alarms Table Unit ID 2 SNMP MIB: fwuUnitID Description:The second portion of unit ID. Values:Between 1 and 88888888 Syntax:UnitId2 Access Level:Not-accessible Unit Type SNMP MIB: fwuUnitType Description:The unit type. Values:Value of UnitType. Syntax:UnitType Access Level:Read-only Major Alarm Codes SNMP MIB: fwuUnitMajorAlarms Description:Alarm code(s) that correspond to any major alarms that occurred in the unit. Syntax:DisplayString Access Level:Read-only Minor Alarm Codes SNMP MIB: fwuUnitMinorAlarms Description:Alarm code(s) that correspond to any minor alarms that occurred in the unit. Syntax:DisplayString Access Level:Read-only Using an SNMP Interface FlexWave Prism Element Management System 7.1 User ManualPage 289 ADCP-77-177 • Issue 1 • July 2011© 2011 ADC Telecommunications, Inc. WORKING WITH SNMP TRAPS This section describes how to view traps in the MIB Browser and how to interpret responses. NOTE:The actual SNMP trap Parameters are listed under the corresponding alarm name in “Troubleshooting Alarms” on page 185. View the Traps NOTE:This procedure shows how to view traps using the AdventNet MIB Browser. This procedure may differ for other MIB browsers. 1In the AdventNet MIB Browser, click the Trap Viewer icon on the Toolbar. NOTE:To receive traps using the manager, you must first register the manager using the procedure in “Set SNMP Trap Managers” on page 138. The Trap Viewer dialog opens. 2In the Port box, enter the desired port number that you entered during trap registration. 3In the Community box, enter the community string for the incoming traps that you entered during trap registration. The default is public. 4Click the Add button to add the Port and Community list to the Trap list (visible in the Trap List list box). 5(Optional) Click the Load button to load the trap parser file. Working with SNMP Traps Page 290FlexWave Prism Element Management System 7.1 User Manual © 2011 ADC Telecommunications, IncADCP-77-177 • Issue 1 • July 2011 6Click the Start button. Trap Viewer begins to receive traps from the specified port and community. The traps when received are listed in the Trap Table. The trap table has the following five columns. •Class—defines the severity of the trap. •Type—defines the type of the trap or the inform request. •Source—represents the IP address of the source from where the traps were sent. •Date—shows the date and time when the trap was received. •Message—lists the VarBind list of the trap, if any. The status of the trap is displayed in the status pane at the bottom of the dialog box. Moreover, the Trap count and the inform count is displayed in the status pane. 7To log the received traps, select the Enable Logging check box. All the incoming traps are logged to a file. The default name of the log file is trap.log. 8To view the details of the traps, click on the Show Details button. You can also right-click the trap in the trap table and select View Trap Details. 9Click Stop to stop listening to the port. 10To delete a trap, select the trap and click the Delete Entry button. You can also right-click the trap in the trap table and select Delete the Selected Rows. Another option in Trap Viewer is the ParserEditor. Trap Viewer can filter the incoming traps according to certain criterion called the Parser Criteria. The configuration of the criterion is made possible by using the ParserEditor. NOTE:To deregister trap receiving, in the snmpTargetAddrTable select the row that corresponds to the registered trap and then click the Delete button. Managing Traps The EMS receives Traps from SNMP agents and converts them to alarms and non-alarmed events for further processing and reporting. NOTE:TRAPS are listed with corresponding EMS alarms in “Troubleshooting Alarms” on page 185. As some alarms can be enabled or disabled, corresponding traps will accordingly be enabled or disabled. Thresholds dictate when an enabled trap is activated. For a list of which alarms can be enabled/disabled, see “Enable and Disable Host and Remote Unit Alarms” on page 178. Using an SNMP Interface FlexWave Prism Element Management System 7.1 User ManualPage 291 ADCP-77-177 • Issue 1 • July 2011© 2011 ADC Telecommunications, Inc. Do the following to enable or disable a trap through SNMP, in which the values must be set in the sequence shown. Do the following to enable or disable an alarm through SNMP, in which the values must be set in the sequence shown. 1Use fwuSystemTrapNodeAddress to set the unit address for the node, where 0 equals the Host, UnitId2 for DRU. 2Use fwuSystemAlarmModuleNo to set the module number to be effected. 3Use fwuSystemModuleAlarmcode to identify which alarm to enable/disable. 4Use fwuSystemAlarmEnabled to change the value to enable/disable the alarm, where: •1 = Enable •0 = Disable Date and Time Stamps in Traps Table 28 describes the date and time fields. For Example: Tuesday May 26, 1992 at 1:30:15 PM EDT is displayed as: 1992-5-26,13:30:15.0,-4:0 Table 28. MIB Date and Time Stamp Fields FieldOctetsContentsRange 11-2year (1) 0...65536 23month1...12 34day1...31 45hour0...23 56minutes0...59 67seconds0...59 78deci-seconds0...9 89direction from UTC+' / '-' 910hours from UTC (2) 0...13 1011minutes from UTC0...59 (1) Value of year is in network-byte order (2) Daylight savings time in New Zealand is +13 Working with SNMP Traps Page 292FlexWave Prism Element Management System 7.1 User Manual © 2011 ADC Telecommunications, IncADCP-77-177 • Issue 1 • July 2011 Variable Bindings For Host Traps, there are 9 variable bindings: 1sysUpTime 2snmpTrapOID 3fwuTrapSequenceNumber 4fwuTrapTimeStamp 5fwuModuleNumber, as shown in Figure 30 Figure 30. Host SeRF Optical Port Assig…
Text truncated - open the document above for the full version.
Mailing Address: P.O. Box 1101, Minneapolis, Minnesota 55440-1101 World Headquarters: Minneapolis, Minnesota USA +1.952.938.8080 www.adc.com November 7, 2011 Attn: Application Examiner, Reviewing Engineer Re: Attestation Statement I, the undersigned, attest that all testing done under my supervision was done in accordance with the Federal Communications Commission’s CFR 47 Part 22 and that the EUT fulfills the requirements of the Federal Communications Commission’s CFR 47 Part 22. Sincerely, Joshua J. Wittman Compliance Engineer Tele: 952 403-8322 Fax: 952 403-8858 Email: [email protected]
Mailing Address: P.O. Box 1101, Minneapolis, Minnesota 55440-1101 World Headquarters: Minneapolis, Minnesota USA +1.952.938.8080 www.adc.com November 7, 2011 Attn: Application Examiner, Reviewing Engineer Re: Name of EUT on Grant FlexWave™ Prism – Cellular 20 Watt Sincerely, Joshua J. Wittman Compliance Engineer Tele: 952 403-8322 Fax: 952 403-8858 Email: [email protected]
Mailing Address: P.O. Box 1101, Minneapolis, Minnesota 55440-1101 World Headquarters: Minneapolis, Minnesota USA +1.952.938.8080 www.adc.com November 7, 2011 Attn: Application Examiner, Reviewing Engineer Re: Request of Confidentiality FCC ID: F8I-PSM0802A Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying as outlined below: Schematics, Technical Description or Theory of Operation, Bill of Materials (BOM’s), and Block Diagrams The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this Application. Sincerely, Joshua J. Wittman Compliance Engineer Tele: 952 403-8322 Fax: 952 403-8858 Email: [email protected]
FlexWave™ PRISM Remote Unit Right View FlexWave™ PRISM Remote Unit Left View FlexWave™ PRISM Remote Unit Rear View FlexWave™ PRISM Remote Unit Top View FlexWave™ PRISM Remote Unit Bottom View FlexWave™ PRISM Remote Unit Open View
FCC ID: F8I-PSM0804A FlexWave™ Prism - Cellular 40W Remote Unit Location of FCC/IC ID Location of FCC/IC Label
INFORMATION ON THIS DOCUMENT IS PROPRIETARY TO ADC AND SHALL NOT BE USED, COPIED, REPRODUCED OR DISCLOSED IN WHOLE OR IN PART WITHOUT WRITTEN CONSENT OF ADC TITLE FlexWave™ Prism – Cellular 20 Watt FCC Identification Label TOLERANCE UNLESS .XX NA OTHERWISE SPECIFIED .XX NA DRAWING NUMBER None A REV DO NOT SCALE DRAWING ENGR. Joshua J. Wittman SIZE A SHEET 1 OF 1 REV ECO DWN DATE A JJW 11-15-2011 XXXX-XXXXXXXX FCC ID: F8I-PSM0802A 2 1.500 REF R.075 (4) DIE CUT LABEL .750 REF 1,4 - See Note 4 for Model Number NOTES: 1 PRINTING TYPE: TRANSFER METHOD. COLOR: BLACK TEXT 8 PT ARIAL NON-BOLD LOCATED APPROXIMATELY AS SHOWN. 2 PRINTING TYPE: TRANSFER METHOD. COLOR: BLACK TEXT 6 PT ARIAL NON-BOLD LOCATED APPROXIMATELY AS SHOWN. MATERIAL: ADC PART NUMBER 1215140 3 4 FWP-B410000MOD
FlexWave™ URH SERF Top View FlexWave™ URH SERF Top View – 1 FlexWave™ URH SERF Top View - 2 FlexWave™ URH SERF Top View – 3 FlexWave™ URH SERF Top View - 4 FlexWave™ URH SERF Bottom View FlexWave™ URH SERF Bottom View - 1 FlexWave™ URH SERF Bottom View - 2 FlexWave™ URH SERF Bottom View – 3 FlexWave™ URH SERF Bottom View - 4
FlexWave™ URH Power Supply Top View FlexWave™ URH Power Supply Bottom View
Motherboard–Front#1 Motherboard–Front#2 Motherboard–Front#3 Motherboard–Back#1 Motherboard–Back#2 Motherboard–Back#3 TxBoard–Front TxBoard–Back RxBoard–Front RxBoard–Back Duplexer#1 Duplexer#2 Duplexer#3 LPA#1 LPA#2 LPA#3 RFModuleAssembly#1 RFModuleAssembly#2 RFModuleAssembly#3 RFModuleAssembly#4 RFModuleAssembly#5 RFModuleAssembly#6 RFModuleAssembly#7 RFModuleAssembly#8
Mailing Address: P.O. Box 1101, Minneapolis, Minnesota 55440-1101 World Headquarters: Minneapolis, Minnesota USA +1.952.938.8080 www.adc.com November 7, 2011 Attn: Application Examiner, Reviewing Engineer Re: Tune-up Procedure The FlexWave™ Prism – Cellular 20 Watt model number FWP-B410000MOD employs a solid- state design that does not require a tune-up procedure. Sincerely, Joshua J. Wittman Compliance Engineer Tele: 952 403-8322 Fax: 952 403-8858 Email: [email protected]
Mailing Address: P.O. Box 1101, Minneapolis, Minnesota 55440-1101 World Headquarters: Minneapolis, Minnesota USA +1.952.938.8080 www.adc.com November 16, 2011 Attn: Application Examiner, Reviewing Engineer The following is the SAR calculation for the FlexWave™ Prism – Cellular 20 Watt, FCC ID: F8I-PSM0802A, using the system’s maximum RF emission. The calculation is based on FCC 47CFR Part 2 and OET 65. Per OET 65: Maximum Permissible Exposure is Freq. (MHz)/1500 = MPE mW/cm 2 881.5 MHz/1500= 0.5877 mW/cm 2 The following equations determine the distance from the antenna that the power density is ≤ 0.5877 mW/cm 2 . +43.57 dBm Transmitter Power (Max) 16.43 dBi Antenna Gain (Max) 43.57 dBm + 16.43 dBi= +60 dBm EIRP +60 dBm EIRP = 1000 Watts EIRP 1000 Watts EIRP = 1000*10 3 mWatts EIRP 0.5877 mW/cm 2 = 1000*10 3 mW/(4*π*r 2 ) r= SQR(1000*10 3 /4*π 0.5877) r= 367.97 cm or 3.67 Meters In addition, the following statement will be added to our installation/operation manual: To comply with Maximum Permissible Exposure (MPE) requirements, the maximum composite output from the antenna …
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 7 | 22 | 869 MHz - 894 MHz | 21.87 W | 270KG7W | 1.5 ppm |

FWP-T4MT000MOD-L
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FWP-W4MT000MOD
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FWP-44MT000MOD
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FWP-84MTA4MMOD
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FlexWave Prism HDM 850 MHz MIMO
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)