Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Nov 27, 2012
Application Purpose
Original Equipment
Date of Application
Nov 27, 2012
Equipment Note
FlexWave Prism HDM 850/1900 MHz
Frequency Range
1930.00000000 - 1995.00000000
Company
ADC Telecommunications Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

TECP-77-141  Issue 2  August 2012 300001744178 Rev B Dual-Band Dual-Slot RF Module Single-Slot RF Module Dual-Slot 40W RF Module HDM RF Module FlexWave Prism ® RF Modules for Prism Remote Units Installation Guide Copyright © 2012 TE Connectivity, Inc. All Rights Reserved. Information contained in this document is company private to TE Connectivity Ltd., and shall not be modified, used, copied, reproduced or disclosed in whole or in part without the written consent of TE. Trademark Information FlexWave, FlexWave Prism, InterReach Spectrum, InterReach Unison, Universal Radio Head, TE Connectivity, and TE connectivity (logo) are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. Disclaimer of Liability Contents herein are current as of the date of publication. TE reserves the right to change the contents without prior notice. Should the content of printed user documentation shipped with product differ from documentation provided on a product CD (inclusive of the associated Help modules), the printed user documentation supersedes the documentation on the product CD. In no event shall TE be liable for any damages resulting from loss of data, loss of use, or loss of profits, and TE further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. Specific Disclaimer for High-Risk Activities This Product is not specifically designed, manufactured, tested or intended for use in high-risk activities including, without restricting the generality of the foregoing, on-line control of aircraft, air traffic, aircraft navigation or aircraft communications; or in the design, construction, operation or maintenance of any nuclear facility. TE (including its affiliates) and its suppliers specifically disclaim any express or implied warranty of fitness for such purposes or any other purposes. FlexWave Prism RF Modules for Prism Remote Units Installation GuidePage 1 TECP-77-141 • Issue 1 • April 2012©2012 TE Connectivity Ltd. TABLE OF CONTENTS TopicsPage Preface .......................................................................................................................... .......................................2 Revision History ......................................................................................................................................................2 FlexWave Prism User Documentation ....................................................................................................................2 Accessing User Documentation on the Customer Portal ...................................................................................................3 Document Ca utions and Notes...........................................................................................................................................3 Standards Certification...........................................................................................................................................4 Overview of RF Mo dules for Prism Remote Units..................................................................................................5 RF Mod ule Components.........................................................................................................................................8 Duplexer and Low Noise Amplifier.....................................................................................................................................9 Linear Power Amplifiers .....................................................................................................................................................9 Digital Proc essing Module................................................................................................................................................10 RF Module Cables.............................................................................................................................................................10 RF Module Cables for Single‐Card, Dual‐Card, and HDM RF Modules...................................................10 RF Mod ule Cables for Dual‐Slot Installations.........................................................................................12 Prism Remote Unit RF Group Assignments ......................................................................................................................13 PRU RF Module Types ..........................................................................................................................................16 Prism Remote Unit Single‐ and Dual‐Card RF Modules....................................................................................................16 Prism Remote Unit HDM RF Modules ..............................................................................................................................17 Prism Remote Unit Dual‐Slot 40W RF Modules................................................................................................................18 Install the RF Module(s)......................................................................................................................................19 Safety Precautions ................................................................................................................................................19 Guard Ag ainst Damage from Electro‐Static Discharge.........................................................................................20 Unpack and Inspect th e RF Module .....................................................................................................................20 Remove Rel ease Liners from the RF Module ...................................................................................................…

Text truncated - open the document above for the full version.

Cover Letter(s)

1(1) Attention: Application Examiner Re: Request for confidentiality Applicant: ADC Telecommunications, Inc. FCC ID: F8I-PSM8192D To whom it may concern, Permanent Confidentiality Request is hereby submitted by ADC Telecommunications, Inc. to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential: • Schematics • Detailed Block diagrams • Detailed Operational/Functional Description • Parts list Rationale for request for confidentiality: ADC Telecommunications, Inc. has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. The fee for confidentiality has been submitted along with the fee for certification. If you have questions or need further information, please contact the undersigned. Sincerely, Joshua J. Wittman Compliance Engineer ADC Telecommunications, Inc.

External Photos

Duplexer #1 Duplexer #2 Duplexer #3 LPA #1 LPA #2 LPA #3 RF Module Assembly #1 RF Module Assembly #2 RF Module Assembly #3 RF Module Assembly #4 RF Module Assembly #5 RF Module Assembly #6 RF Module Assembly #7 RF Module Assembly #8

ID Label/Location Info

INFORMATION ON THIS DOCUMENT IS PROPRIETARY TO ADC AND SHALL NOT BE USED, COPIED, REPRODUCED OR DISCLOSED IN WHOLE OR IN PART WITHOUT WRITTEN CONSENT OF ADC TITLE FlexWave™ Prism – HDM 850/1900 FCC Identification Label TOLERANCE UNLESS .XX NA OTHERWISE SPECIFIED .XX NA DRAWING NUMBER None A REV DO NOT SCALE DRAWING ENGR. Joshua J. Wittman SIZE A SHEET 1 OF 1 REV ECO DWN DATE A JJW 11-9-2012 XXXX-XXXXXXXX FCC ID: F8I-PSM8192D 2 1.500 REF R.075 (4) DIE CUT LABEL .750 REF 1,4 - See Note 4 for Model Number NOTES: 1 PRINTING TYPE: TRANSFER METHOD. COLOR: BLACK TEXT 8 PT ARIAL NON-BOLD LOCATED APPROXIMATELY AS SHOWN. 2 PRINTING TYPE: TRANSFER METHOD. COLOR: BLACK TEXT 6 PT ARIAL NON-BOLD LOCATED APPROXIMATELY AS SHOWN. MATERIAL: ADC PART NUMBER 1215140 3 4 FWP-C41T000MOD FCC ID: F8I-PSM8192D FlexWave™ Prism – 850/1900 Remote Unit Location of FCC/IC ID Location of FCC/IC Label

Internal Photos

Motherboard – Front #1 Motherboard – Front #2 Motherboard – Front #3 Motherboard – Back #1 Motherboard – Back #2 Motherboard – Back #3 Tx Board – Front Tx Board – Back Rx Board – Front Rx Board – Back

RF Exposure Info

Mailing Address: 1187 Park Place, Shakopee, Minnesota 55379 www.te.com November 9, 2012 Attn: Application Examiner, Reviewing Engineer The following is the SAR calculation for the FlexWave™ Prism – HDM 850/1900, FCC ID: F8I-PSM8192D, 850 Band, using the system’s maximum RF emission. The calculation is based on FCC 47CFR Part 2 and OET 65. Per OET 65: Maximum Permissible Exposure is Freq. (MHz)/1500 = MPE mW/cm 2 881.5 MHz/1500= 0.5877 mW/cm 2 The following equations determine the distance from the antenna that the power density is ≤ 0.5877 mW/cm 2 . +44.10 dBm Transmitter Power (Max) 15.90 dBi Antenna Gain (Max) 44.10 dBm + 15.90 dBi= +60 dBm EIRP +60 dBm EIRP = 1000 Watts EIRP 1000 Watts EIRP = 1000*10 3 mWatts EIRP 0.5877 mW/cm 2 = 1000*10 3 mW/(4*π*r 2 ) r= SQR(1000*10 3 /4*π 0.5877) r= 368.06 cm or 3.68 Meters In addition, the following statement will be added to our installation/operation manual: To comply with Maximum Permissible Exposure (MPE) requirements, the maximum composite output from the antenna cannot exceed 1000 Watts EIRP and the antenna must be permanently installed in a fixed location that provides at least 6 meters (20 feet) of separation from all persons. Sincerely, Joshua J. Wittman Compliance Engineer Tele: 952 403-8322 Fax: 952 403-8858 Email: [email protected]

RF Exposure Info

Mailing Address: 1187 Park Place, Shakopee, Minnesota 55379 www.te.com November 9, 2012 Attn: Director of Certification Dear Sir or Madam: The following is the SAR calculation for the FlexWave™ Prism – HDM 850/1900, 1900 Band, using the system’s maximum RF emission. The calculation is based on FCC 47CFR Part 2 and OET 65. Per OET 65: Maximum Permissible Exposure is 1.0 mW/cm 2 over 30 minutes. 1500 MHz - 100,000 MHz The following equations determine the distance from the antenna that the power density is ≤ 1.0 mW/cm 2 . To convert to EIRP use the relation: EIRP = ERP X 1.64 +44.05 dBm Transmitter Power (Max) 15.95 dBi Antenna Gain (Max) 44.05 dBm + 15.95 dBi= +60 dBm EIRP +60 dBm ERP = 1640 Watts EIRP 1640 Watts EIRP = 1640*10 3 mWatts EIRP 1.0 mW/cm 2 = 1640*10 3 mW/(4*π*r 2 ) r= SQR(1640*10 3 /4*π 1.0) r= 361.35 cm or 3.61 Meters In addition, the following statement will be added to our installation/operation manual: To comply with Maximum Permissible Exposure (MPE) requirements, the maximum composite output from the antenna cannot exceed 1640 Watts EIRP and the antenna must be permanently installed in a fixed location that provides at least 6 meters (20 feet) of separation from all persons. Sincerely, Joshua J. Wittman Compliance Engineer Tele: 952 403-8322 Fax: 952 403-8858 Email: [email protected]

Test Report

TEST REPORT Report Number: 100913866MIN-001 Project Number: G100913866 Testing performed on the FWP-C41T000MOD to 47 CFR, Part 22:2010, Enclosure Spurious Radiated Emissions 47 CFR, Part 24:2010, Enclosure Spurious Radiated Emissions For ADC Telecommunications Inc. - a TE Connectivity Company Test Performed by: Test Authorized by: Intertek Testing Services NA, Inc. 7250 Hudson Blvd., Suite 100 Oakdale, MN 55128 USA ADC Telecommunications Inc.- a TE Connectivity Company 541 E Trimble Road San Jose, CA 95131 USA Prepared by: Date: November 2, 2012 Richard Blonigen Reviewed by: Date: November 2, 2012 Norman Shpilsher This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. This report must not be used to claim product endorsement by A2LA, NIST nor any other agency of the U.S. Government. EMC Report No: 100913866MIN-001 Page 2 of 29 TABLE OF CONTENTS 1.0 DESCRIPTION OF THE SAMPLE (EUT)................................................................................. 3 2.0 TEST SUMMARY.......................................................................................................................... 4 2.1 Statement of the Measurement Uncertainty.............................................................................. 4 3.0 EQUIPMENT UNDER TEST....................................................................................................... 5 3.1 Power Configuration..................................................................................................................... 5 3.2 EUT Configuration......................................................................................................................... 5 3.3 Environmental conditions............................................................................................................. 6 4.0 TEST CONDITIONS AND RESULTS........................................................................................ 7 4.1 Enclosure Spurious Radiated Emissions................................................................................... 7 5.0 TEST EQUIPMENT..................................................................................................................... 27 EMC Report No: 100913866MIN-001 Page 3 of 29 1.0 DESCRIPTION OF THE SAMPLE (EUT) Model: FWP-C41T000MOD Type of EUT: 850/1900 MHz HDM Dual Band RF Module Operating Frequency Range: 869-894MHz 1930-1995 MHz Company: ADC Telecommunications Inc. - a TE Connectivity Company Customer: Sue Cyr Address: 541 E. Trimble Road San Jose, CA 95131 USA Phone: 408-952-2445 Fax: 408-952-2645 e-mail: [email protected] Test Standards: EN 55022:2006 +A1:2007, Class EN 55011:2007 +A2:2007, Group , Class 47 CFR, Part 22:2010, Enclosure Spurious Radiated Emissions 47 CFR, Part 24:2010, Enclosure Spurious Radiated Emissions ICES-003, Issue 4:2004 EN 55014-1:2006 EN 61326-1:2006 Class for Radiated and Conducted Emissions Basic Immunity Test Requirements Immunity Test Requirements for Industrial Locations EN 60601-1-2:2001 +A1:2006 EN 61000-6-3:2007 EN 61000-6-4:2007 EN 61000-3-2:2006 EN 61000-3-3:1995 +A1:2001 +A2:2006 EN 61000-6-1:2007 EN 61000-6-2:2005 EN 55024:1998 + A1:2001 + A2:2003 Date Sample Submitted: October 26, 2012 Test Work Started: October 26, 2012 Test Work Completed: October 26, 2012 Test Sample Conditions: Damaged Poor (Usable) Good Prototype Production Used EMC Report No: 100913866MIN-001 Page 4 of 29 2.0 TEST SUMMARY Referring to the performance criteria and the operating mode during the tests specified in this report, the equipment complies with the requirements according to the following standards. TEST STANDARD TEST RESULT Part 22 Enclosure Spurious Radiated Emissions Pass Part 24 Enclosure Spurious Radiated Emissions Pass 2.1 Statement of the Measurement Uncertainty Note: The measured result in this report is within the specification limits by more than the measurement uncertainty; the measured result indicates that the product tested complies with the specification limit. The expanded uncertainty (k = 2) for radiated emissions from 30 to 1000 MHz has been determined to be: ±4 dB at 10m and ±5.4 dB at 3m The expanded uncertainty (k = 2) for conducted emissions from 150 kHz to 30 MHz has been determined to be: ±2.6 dB EMC Report No: 100913866MIN-001 Page 5 of 29 3.0 EQUIPMENT UNDER TEST 3.1 Power Configuration Rated voltage: 120VAC 230VAC 400VAC other Rated current: Amp. Rated frequency: 50Hz 60Hz Number of phases: 1 Phase 3 Phases 3.2 EUT Configuration The equipment under test was operated during the measurement under the following conditions: - Standby - Test program (H - Pattern) - Continuous Operation (see details below) - Specific test program - Operating modes of the EUT: No. Description 1 Continuous transmitting at 870MHz, 881MHz, and 893MHz at 43dBm output power 2 Continuous transmitting at 1931MHz, 1962MHz, and 1994MHz at 43dBm output power Cables: No. Type Length Designation Note 1 Fibre optic 10m RF signal cables to the Support Equipment 2 3-wire unshielded 2m AC Power Support equipment/Services: No. Item Description 1 Agilent 8648B (located outside Test site) Signal Generator 2 Prism Host Unit 3 Prism Host 54VDC P…

Text truncated - open the document above for the full version.

Test Report

M N 1 2 1 1 1 4 _ F C C _ P r i s m _ H D M _ 8 5 0 / 1 9 0 0 _ F C C - I D : F 8 I - P S M 8 1 92 D Page 1 Test Report Summary FCC CFR 47, Part 22 Subpart H Cellular Radiotelephone Service FCC CFR 47, Part 24 Subpart E Broadband PCS Manufacturer: ADC Telecommunications, Inc Name of Equipment: FlexWave™ Prism – HDM 850/1900 MHz RF Module Model Number(s): FWP-C41T000MOD Manufacturer’s Address: P.O. Box 1101 Minneapolis, MN 55440-1101 Test Report Number: MN121114_FCC_Prism_HDM_850/1900 FCC-ID: F8I-PSM8192D Test Date(s): 26 October, 2012 (Intertek) 25, 30, 31 October & 1, 2, 6, 7, 8 November (ADC) According to testing performed at Intertek, the above-mentioned unit is in accordance with the applicable electromagnetic compatibility (EMC) portions of the requirements defined in FCC Part 22 and 24. It is the manufacturer’s responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical characteristics. Any modifications necessary for compliance made during testing on the above mentioned date(s) must be implemented in all production units for compliance to be maintained. All testing was done in accordance with the Federal Communications Commission’s CFR 47 Part 22 and 24. The EUT fulfills the requirements of the Federal Communications Commission’s CFR 47 Part 22 and 24. Date: 14 November, 2012 Location: Intertek Testing Services (INTERTEK) ADC Telecommunications 7250 Hudson Blvd., Suite 100 1187 Park Place Oakdale, MN 55128 Shakopee, MN 55379 Phone: (651) 730-1188 Phone: (952) 403-8322 Fax: (651) 730-1282 Testing Conducted by (ADC): And Report Written by: Joshua J. Wittman Compliance Engineer M N 1 2 1 1 1 4 _ F C C _ P r i s m _ H D M _ 8 5 0 / 1 9 0 0 _ F C C - I D : F 8 I - P S M 8 1 92 D Page 2 EMC Emission – T E S T R E P O R T Test Report File Number: MN121114_FCC_Prism_HDM_850/1900 FCC-ID: F8I-PSM8192D Date of Issue: 14 November, 2012 Model Number(s): FWP-C41T000MOD Product Name: FlexWave™ Prism – HDM 850/1900 MHz RF Module Product Type: Repeater Applicant: ADC Telecommunications, Inc Manufacturer: ADC Telecommunications, Inc License Holder: ADC Telecommunications, Inc Address: P.O. Box 1101 Minneapolis, MN 55440-1101 Test Result: ▪ Positive ▫ Negative Test Project Number: 100913866MIN-001 Reference(s) Total pages including Appendices: 159 M N 1 2 1 1 1 4 _ F C C _ P r i s m _ H D M _ 8 5 0 / 1 9 0 0 _ F C C - I D : F 8 I - P S M 8 1 92 D Page 3 1.0 TABLE OF CONTENTS 1.0 Table of Contents .................................................................................................... 3 2.0 Revision Description ................................................................................................ 4 3.0 Documentation ....................................................................................................... 4 3.1 Test Regulations .................................................................................................. 4 3.2 Summary: ........................................................................................................... 5 3.3 Test Operation Mode ............................................................................................. 5 3.4 Configuration of the Device Under Test: .................................................................. 5 3.5 Product Options: .................................................................................................. 5 3.6 EUT Specifications and Requirements: .................................................................... 5 3.7 Cables: ............................................................................................................... 5 3.8 Power Requirements: ........................................................................................... 6 3.9 Typical Installation and/or Operating Environment: .................................................. 6 3.10 Other Special Requirements: .............................................................................. 6 3.11 EUT Software: ................................................................................................... 6 3.12 EUT System Components ................................................................................... 6 3.13 Deviations from Standard: .................................................................................. 6 3.14 General Remarks: ............................................................................................. 7 4.0 Test Set-Up Drawings and Photos ............................................................................. 8 4.1 Test Set-up Photo, Radiated Emissions ................................................................... 8 4.2 Test Set-up Drawings ........................................................................................... 9 5.0 Test Equipment .................................................................................................... 11 6.0 Test Results ......................................................................................................... 12 6.1 FCC 22.917 & 24.238 Emissions Limits – Band Edge ............................................... 12 6.2 FCC 2.1049, 22.917, & 24.238 – Occupied Bandwidth ............................................ 28 6.3 FCC 2.1046, 22.913, & 24.232 Power Limits – Output Power ................................... 44 6.4 FCC 2.1051, 22.917, & 24.238 Emissions Limits – Spurious Emissions at Antenna ...... 47 6.5 FCC 2.1055, 22.355, & 24.235 – Frequency Stability ............................................ 154 7.0 Appendix B ........................................................................................................ 157 8.0 Appendix C ........................................................................................................ 159 M N 1 2 1 1 1 4 _ F C C _ P r i s m _ H D M _ 8 5 0 / 1 9 0 0 _ F C C - I D : F 8 I - P S M 8 1 92 D Page 4 2.0 REVISION DESCRIPTION Rev Total Pages Date Descr…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Joshua Wittman(Compliance Engineer)
[email protected]952-403-8322Fax: 952-403-8858

Test Firm

Intertek Testing ServicesUri Spector
[email protected]651-730-1188Fax: 651-730-1282

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
824E1.93 GHz - 2.00 GHz20.417 WGXW1.5 ppm
Confidentiality
Long Term
Grant Notes
Power output listed is composite for multi-channel operation. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of �1.1307(b) (3) for satisfying RF exposure compliance. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of � 1.1307(b) (3) of the rules.

Other Applications from ADC Telecommunications Inc

FWP-T4MT000MOD-L - FCC ID F8I-PSM25TDL - ADC Telecommunications Inc
F8I-PSM25TDL

FWP-T4MT000MOD-L

Sep 28, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
FWP-W4MT000MOD - FCC ID F8I-PSM230WM - ADC Telecommunications Inc
F8I-PSM230WM

FWP-W4MT000MOD

Jul 29, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
FWP-44MT000MOD - FCC ID F8I-PSM0800M - ADC Telecommunications Inc
F8I-PSM0800M

FWP-44MT000MOD

Aug 26, 2014

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
FWP-84MTA4MMOD - FCC ID F8I-PSM1921D - ADC Telecommunications Inc
F8I-PSM1921D

FWP-84MTA4MMOD

Aug 24, 2014

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
FlexWave Prism HDM 850 MHz MIMO - FCC ID F8I-PSM0850M - ADC Telecommunications Inc
F8I-PSM0850M

FlexWave Prism HDM 850 MHz MIMO

Jul 27, 2014

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)