
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ADCP-75-110 Issue B March 2001 Digivance ™ 800 Mhz Indoor Coverage Solution Installation and Operation Manual DRAFT 1126955 Rev A ADCP-75-110 • Issue B • March 2001 Page ii COPYRIGHT 2001, ADC Telecommunications, Inc. All Rights Reserved Printed in the U.S.A. REVISION HISTORY ISSUEDATEREASON FOR CHANGE Issue B03/01Original TRADEMARK INFORMATION ADC and FiberGuide are registered trademarks of ADC Telecommunications, Inc. Digivance is a trademark of ADC Telecommunications, Inc. LC is a trademark of Lucent Technologies Inc. TORX is a registered trademark of Textron, Inc. DISCLAIMER OF LIABILITY Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. This publication may be verified at any time by contacting ADC’s Technical Assistance Center at 1-800-366-3891, extension 63475 (in U.S.A. or Canada) or 952-946-3475 (outside U.S.A. and Canada), or by e-mail to [email protected]. ADC Telecommunications, Inc. P.O. Box 1101, Minneapolis, Minnesota 55440-1101 In U.S.A. and Canada: 1-800-366-3891 Outside U.S.A. and Canada: (952) 938-8080 Fax: (952) 946-3292 ADCP-75-110 • Issue B • March 2001 Page iii  2001, ADC Telecommunications, Inc. TABLE OF CONTENTS ContentPage 1SYSTEM FUNCTIONAL OVERVIEW AND UNIT DESCRIPTIONS........................................1 1.1System Functional Overview.......................................................1 1.2Digital Host Unit Description.......................................................3 1.3Digital Remote Unit Description.....................................................7 1.4Digital Expansion Unit Description...................................................9 1.5Terms and Definitions............................................................12 1.6Specifications.................................................................13 2INSTALLATION PLANNING AND SYSTEM DESIGN................................................16 2.1Base Station Interface Requirements..................................................16 2.2Locating and Mounting Requirements.................................................18 2.3Powering Requirements..........................................................19 2.4Optical Options and Requirement s...................................................20 2.5Coaxial Cable Requirements.......................................................20 2.6System Expansion Planning........................................................20 2.7DRU Antenna Options............................................................21 2.8Local Alarm System Reporting Requirements............................................21 2.9Maintenance Requirements........................................................22 2.10 System Design Recommendations...................................................22 3DIGITAL HOST UNIT INSTALLATION PROCEDURE................................................25 3.1System Plan Review and Pre-Installation Cable Routing.....................................25 3.2Tools and Materials.............................................................25 3.3Unpacking and Inspection.........................................................25 3.4Mounting Procecure ............................................................25 3.5Chassis Ground Procedure.........................................................29 3.6Coaxial Cable Connections........................................................29 3.7Ports 1-6 Optical Connections......................................................30 3.8DC Power Connections...........................................................32 3.9Local Alarm System Connections....................................................33 3.10 AC Power Connections...........................................................35 3.11 Create As-Built Drawing..........................................................36 4SYSTEM OPERATION..................................................................37 4.1Tools and Materials.............................................................37 4.2Turn-Up System and Verify Operation.................................................37 4.3Correct Installation Problems.......................................................39 4.4Test System Performance.........................................................42 5SYSTEM MAINTENANCE PROCEDURES......................................................43 5.1Tools and Materials .............................................................43 5.2Fault Detection and Alarm Reporting..................................................43 5.3Fault Isolation and Troubleshooting..................................................44 5.4Test Procedures................................................................46 5.5DHU or DEU Fan Replacement......................................................49 Continued ADCP-75-110 • Issue B • March 2001 Page iv  2001, ADC Telecommunications, Inc. TABLE OF CONTENTS ContentPage 6GENERAL INFORMATION...............................................................51 6.1Warranty/Software.............................................................51 6.2Software Service Agreement.......................................................51 6.3Repair/Exchange Policy..........................................................51 6.4Repair Charges................................................................51 6.5Replacement/Spare Products......................................................52 6.6Returned Material..............................................................52 6.7Customer Information and Assistance.........................................…
Text truncated - open the document above for the full version.
Optical Fiber D To A Converter RF FILTER SAW FILTER 6 WAY DIGITAL COMBINER LASER RX (1 OF 6) IF Spectrum Analog Baseband Spectrum Digital Baseband Spectrum Synthesizer Synthesizer To Base Station 829 - 849 MHz Baseband LO and Reference Block Diagram Digital Host Unit Compsite Digital Baseband Spectrum 161 MHz IF Spectrum 869 - 894 MHz From Base Station SAW FILTER A To D Converter 6 WAY DIGITAL SPLITTER LASER TX (1 OF 6) Optical Fiber Block Diagram Digital Expansion Unit LASER RX 6 WAY DIGITAL SPLITTER LASER TX (1 OF 6) LASER TX 6 WAY DIGITAL COMBINER LASER RX (1 OF 6) Optical Fiber ( 1 of 6) To Digital Remote Units Or Addational Digital Expansion Units Optical Fiber From Digital Host Units Or Digital Expansion Units Forward Path Digitized Baseband Spectrum Forward Path Digitized Baseband Spectrum Optical Fiber ( 1 of 6) From Digital Remote Units Or Addational Digital Expansion Units Optical Fiber To Digital Remote Units Or Addational Digital Expansion Units 869 -894 MHz Spectrum Out @ + 13dBm Duplexer External Antenna 824 To 849 MHz Spectrum IF Spectrum Analog Baseband Spectrum Optical Fiber To Digital Host Unit or Digital Expansion Unit Digital Baseband Spectrum Baseband LO and Reference LASER RX D TO A Converter SAW FILTER RF FILTER Reverse Synthesizer Optical Fiber From Digital Host Unit Or Digital Expansion Unit IF Spectrum Forward Synthesizer 869 - 894 MHz Spectrum Power AMP Block Diagram Digital Remote Unit Digital Baseband Spectrum LASER TX A To D Converter SAW FILTER LNA
DHU Front view DHU Left top view DHU Rear top view DHU right top DRU Front view DRU left top DRU rear top DRU right top
DHU board top DHU BOARD TOP NO SHIELDS DHU BOARD BOTTOM DRU BOARD BOTTOM NO SHIELDS DRU BOARD BOTTOM DRU BRD TOP NO RF SHIELDS DRU TOP POWER DISTRIBUTION BRD BOTTOM
File No. W101574001, Page A2 of A9 EMM0094 REV 09.95 TEST SETUP FOR EMISSIONS TESTING WILD RIVER LAB Large Test Site Notes: 1.Items shown in dotted lines are located on the floor below the test area. It is 5 meters vertically from the ground floor to the test area. 2.50 Hz, 60 Hz, and 400 Hz are power panels for alternating current. 3.The antenna may be positioned horizontally 3, 10 or 30 meters from the center of the turntable. 4.The circle is a 6.7 meter diameter turntable. 5.A ground plane is in the plane of this sheet. 6.The test sample is shown in the azimuthal position representing zero degrees. EUT 0 90270 180 60 Hz 50 Hz 400 Hz Shielded Enclosure ANTENNA File No. W211557801, Page A3 of A12 EMM0096 REV 09.95 TEST SETUP FOR EMISSIONS TESTING WILD RIVER LAB Screen Room Other Measurements: 2 meters from top of EUT to ceiling 80 cm from closest part of EUT to the LISN Non-conducting Table EUT LISN SIDE VIEW 80 cm EUT LISN Instrumentation Table Receiver 40 cm Non-conducting Table TOP VIEW LISN Vertical Ground Plane 40 cm Inter-modulation Test for ADC Inc. Digivance 800 System. Test Set-up Table 1 Test Equipment EquipmentMFG/ModelADC Serial NumberCalibration Due. (NIST) Dual Output CDMA Signal Generator Noise.com/UFX-CDMAMC27639June 01 Signal GeneratorHP/HP8921AMC27526Sept 01 CDMA AdapterHP/HP83203BMC27525Sept 01 CombinerMiniCircuits/ZC2PD-9009433-05Nov 01 AttenuatorAlan/50SDV59-168287269Nov 01 Spectrum AnalyzerHP/HP8594EMC27731March 01 Results: Pass (see plots) CDMA Signal Generator CDMA Signal Generator CDMA Signal Generator Combiner Attenuator EUT Spectrum Analyzer
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 22.901(d) | 869 MHz - 894 MHz | 20.00 mW | EXTENDR | 1.5 ppm |

FWP-T4MT000MOD-L
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FWP-W4MT000MOD
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FWP-44MT000MOD
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FWP-84MTA4MMOD
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
FlexWave Prism HDM 850 MHz MIMO
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)