FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Rosslare Enterprises Ltd/
  3. GCD-MD-W11FGR

GCD-MD-W11FGRWireless access control door interface

Rosslare Enterprises Ltd
Wireless access control door interface - FCC ID GCD-MD-W11FGR - Rosslare Enterprises Ltd
Click to zoom

Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
Dec 20, 2010
Application Purpose
Original Equipment
Date of Application
Dec 20, 2010
Equipment Note
Wireless access control door interface
Frequency Range
433.32000000 - 433.92000000
Company
Rosslare Enterprises Ltd
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Wireless Access Control Door Interface MD-W11 Installation Manual November 2010 Introduction MD-W11 Installation Manual Page 1 Table of Contents 1. Introduction ...................................................................... 2 1.1 Overview .................................................................................... 2 1.2 Features...................................................................................... 3 2. Technical Specifications .................................................... 6 2.1 Electrical Characteristics ............................................................ 6 2.2 Environmental Characteristics ................................................... 7 2.3 Dimensions ................................................................................. 7 2.4 Supported Card Transmission Formats ...................................... 8 2.5 Supported Keypad Transmission Formats .................................. 8 2.6 Available models ....................................................................... 8 3. Installation and Wiring ........................................................ 9 3.1 The Installation Kit ....................................................................... 9 3.2 General Installation Requirements ............................................. 9 3.3 Installing the MD-W11N Unit...................................................... 10 3.4 Wiring the MD-W11N Unit .......................................................... 11 3.5 Installing the MD-W11F Unit ...................................................... 14 3.6 Wiring the MD-W11F Unit .......................................................... 14 3.7 Installing the MD-W11BP Battery Pack ...................................... 16 3.8 Wiring the MD-W11BP Battery Pack .......................................... 16 3.9 Indications on the Near and Far Units ...................................... 17 3.10 Installer Recommendations ..................................................... 17 4. Enrollment ...................................................................... 18 4.1 Enrolling the Units ...................................................................... 18 4.2 Dipswitches .............................................................................. 18 4.2.1. Near and Far Unit Modes ................................................................. 20 5. Operational Information .................................................. 23 Appendix A. Limited Warranty .............................................. 24 Appendix B. Declaration of Conformity ................................. 26 Appendix C. Technical Support ............................................ 27 Introduction MD-W11 Installation Manual Page 2 1. Introduction 1.1 Overview Rosslare Enterprises Ltd.’s MD-W11 Wireless Access Control Door Interface, is a quick, inexpensive solution for connecting remote door devices, such as readers, locks, and REX Buttons to an access control unit. The MD-W11 Wireless Access Control Door Interface consists of two units per door, one located near the controller (the Near unit) and the other near the door (the Far unit). The Near unit is connected to a Rosslare door controller (e.g., AC-215, AC-225, or AC-525). The Far unit is connected to proximity card readers or keypads (e.g., AY-K12 and AY-Q64B). When a card is read or a code is keyed onto the keypad, the Far unit transmits the information to the Near unit. The Near unit, attached to the AC-225 or to another controller, determines whether or not to open the door. The controller then sends the message to the Near unit, which transmits it to the Far unit, and if authorized, the door is opened. Caution: Changes or modifications to this equipment not expressly approved by the party responsible for compliance (Rosslare Ltd.) could void the user’s authority to operate the equipment. Introduction MD-W11 Installation Manual Page 3 1.2 Features The MD-W11 Wireless Access Control Door Interface includes: • Bi-directional RF data communication • Supports PIN codes and card formats, such as Wiegand 26 bit, 32 bit, and PIN code 6 bit (see list of formats on page 8). • Lock and door relay commands • Tamper, door monitor, and REX messages between the controller and the interface unit • Rolling Code to increase security • Four different RF channels to prevent collisions • Built-in charger for up to 12VDC, 7Ah backup battery on the Far unit • Transfers proximity card information and LED control, reader tamper, lock relay commands, REX, and door monitor events between the coupled units. • Optional MD-W11BP battery pack housing with space for 12VDC/800m Ah, sealed lead-acid battery. • Suitable for indoor use. • Available in 869 MHz (H) and 433.92 MHz (G) bands • The NEAR unit is powered from the controller's power supply. The FAR unit is powered by a local wall transformer. A built-in charger provides battery backup. The MD-W11 Wireless Access Control Door Interface is displayed in Figures 1 and 2. Introduction MD-W11 Installation Manual Page 4 Figure 1: MD-W11 Wireless Access Control Door Interface – Near & Far Unit Figure 2: MD-W11 Wireless Access Control Door Interface – G Near Unit (with external Antenna) Introduction MD-W11 Installation Manual Page 5 Figure 3: MD-W11 Wireless Access Control Door Interface – Battery Pack Technical Specifications MD-W11 Installation Manual Page 6 2. Technical Specifications 2.1 Electrical Characteristics Input Voltage: Far Unit: Near Unit: 12-24 AC, 15-24V DC. 13.8V DC from the controller's power supply or wall adapter. Battery Charger: 12V sealed Lead-Acid, up to 7Ah (Far Unit) Input Current: Standby: 70m Ah Max: 160mA Maximum Range: (With External Antenna) Open field: 300 meters (985 feet) Range depends on RF related environmental conditions. Response time: Up to 500ms with Rosslare’s AC-215 controller and reader. Response time depends on RF link quality, number of doors used as well as controller and reader resp…

Text truncated - open the document above for the full version.

Cover Letter(s)

RF_160, Issue 02 Declaration of Authorization We Name: Rosslare Enterprises Ltd. Address: Flat 12, 9 Floor, Wing Fat Ind. Bldg., 12 Wang Tai Road City: Kowloon Bay, Kowloon Country: Hong Kong ............................................................................ Declare that: Name Representative of agent: ............. (1) Agent Company name: Hermon Laboratories Ltd. Address: Harakevet Industrial Zone City: Binyamina 30500 Country Israel is authorized to apply for Certification of the following product(s): Product description: ... Wireless Access Control Door Interface Type designation: ... MD-W11FGR................... Trademark: ... Rosslare........................................ on our behalf. Date: December 8, 2010 Name: Joe LeKostaj .......................... (2) Function: Engineering Manager Signature: ............................... Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.

Cover Letter(s)

FCC, Request for non-disclosure Date: 16-Jul-10 RF_501, Issue 6 Page 1 of 1 Company Name: Rosslare Enterprises Ltd. Address: Flat 12, 9 Floor, Wing Fat Ind. Bldg., 12 Wang Tai Road City: Kowloon Bay, Kowloon Country: Hong Kong To: Telefication B.V., Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Request for confidentiality FCC ID: GCD-MD-W11FGR Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (note 1): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Planned Release Date STC: (notes 2, 3, 4, 5) Date: December 8, 2010 Name and signature of applicant: Mr. Joe LeKostaj Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period

External Photos

Rosslare Enterprises Ltd. FCC ID:GCD- MD-W11FGR Page 1 of 3 EXTERNAL PHOTOGRAPHS This document contains 2 photographs Rosslare Enterprises Ltd. FCC ID:GCD- MD-W11FGR Page 2 of 3 Photograph No.1 MD-W11FGR Far unit front view Rosslare Enterprises Ltd. FCC ID:GCD- MD-W11FGR Page 3 of 3 Photograph No.2 MD-W11FGR Far unit rear side view

ID Label/Location Info

SECURITY PRODUCT N/A MD-W11FGR LABEL, FCC CONTROLLED DRAWING This drawing is the property of RESL and can not be copied or loaned without written permission. DETAIL NAME DATE APPROVALDATE VER REV PROJECT MATERIAL QUANTITY DRAWN DATE DATE DATE UNIT DWG SIZE SHEET OF CHECKED APPROVED SCALE CAD FILE DWG NO. MODEL DESCRIPTION PART NO. FINISH UNLESS OTHERWISE SPECIFIED OPTION DECIMAL XX XX.X XX.XX XX.XXX 1.00 0.30 0.10 0.01 0.50 0.10 0.05 0.01 0.002 0.10 0.02 0.005 RADIUS CHAMFERS ANGLE R05 = 0.050 R1 = 0.100 R2 = 0.200 R5 = 0.500 XR = R MAX. C01 = 0.10 X 45 C02 = 0.20 X 45 C05 = 0.50 X 45 C1 = 1.00 X 45 S = STONE 0 - 30’ EDM (VDI) 27 - 30 SURFACE: A B B A 4 4 3 2 1 1 2 3 1 DONNA 1 : 1 MM A4 1 1 MDW11FGR LABEL 72058 29 Nov 10 Synthetic paper 0604-0000000+00 Donna29 Nov 10 A0 The first issue Model: MD-W11FGR Far Unit Bi-directional Wireless Door Interface Made in China Rosslare Electronics (Shenzhen) Ltd. 45.00 2 7 . 0 0 C3.00 3XR2.00 1. Font - Arial 2. Material: Synthetic paper FASSON# BW9664 with back adhesive 3. Foreground: Black Background: White 4. Part must be RoHS compliant. Wireless Door Interface MD-W11FGR FCC ID: GCD-MD-W11FGR 433.92 MHz This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, 2) This device must accept any interference received, including interference that may cause undesired operation. 2 2 . 0 0 37.00 4XR1.00

ID Label/Location Info

Rosslare Enterprises Ltd. FCC ID:GCD-MD-W11FGR Page 1 of 1 Label location The label is affixed on the rear side of the MD-W11FGR Far unit as shown below. The label material is PVC with a permanent adhesive. The label with FCC ID:GCD-MD-W11FGR will be located here. FCC ID:GCD-MD-W11FGR

Internal Photos

Rosslare Enterprises Ltd. FCC ID:GCD-MD-W11FGR Page 1 of 6 INTERNAL PHOTOGRAPHS This document contains 5 photographs Rosslare Enterprises Ltd. FCC ID:GCD-MD-W11FGR Page 2 of 6 Photograph No.1 MD-W11FGR Far unit internal view Rosslare Enterprises Ltd. FCC ID:GCD-MD-W11FGR Page 3 of 6 Photograph No.2 MD-W11FGR Far unit internal view Rosslare Enterprises Ltd. FCC ID:GCD-MD-W11FGR Page 4 of 6 Photograph No.3 PCB top view Rosslare Enterprises Ltd. FCC ID:GCD-MD-W11FGR Page 5 of 6 Photograph No.4 PCB second side view Rosslare Enterprises Ltd. FCC ID:GCD-MD-W11FGR Page 6 of 6 Photograph No.5 Antenna close view

Test Report

Hermon Laboratories Ltd. Harakevet Industrial Zone, Binyamina 30500, Israel Tel. +972-4-6288001 Fax. +972-4-6288277 E-mail: [email protected] Page 1 of 47 Report ID: ROSRAD_FCC.21191_rev1.doc Date of Issue: 11/23/2010 ELECTRICAL TESTING 0839.01 TEST REPORT ACCORDING TO: FCC CFR 47 PART 15 subpart C, section 15.231(a) and subpart B FOR: Rosslare Enterprises Ltd. Wireless Access Control Door Interface Far unit Model: MD-W11FGR This report is in conformity with ISO/ IEC 17025. The "A2LA Accredited" symbol endorsement applies only to the tests and calibrations that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd. Report ID: ROSRAD_FCC.21191_rev1.doc Date of Issue: 11/23/2010 Page 2 of 47 Table of contents 1 Applicant information .........................................................................................................................................................3 2 Equipment under test attributes ........................................................................................................................................3 3 Manufacturer information ..................................................................................................................................................3 4 Test details ........................................................................................................................................................................3 5 Tests summary ..................................................................................................................................................................4 6 EUT description .................................................................................................................................................................5 6.1 General information ...........................................................................................................................................................5 6.2 Ports and lines ...................................................................................................................................................................5 6.3 Support and test equipment ..............................................................................................................................................5 6.4 Changes made in EUT ......................................................................................................................................................5 6.5 Test configuration ..............................................................................................................................................................6 6.6 Transmitter characteristics ................................................................................................................................................7 7 Transmitter tests according to 47CFR part 15 subpart C requirements...........................................................................8 7.1 Periodic operation requirements .......................................................................................................................................8 7.2 Field strength of emissions..............................................................................................................................................11 7.3 Occupied bandwidth test .................................................................................................................................................22 7.4 Conducted emissions ......................................................................................................................................................24 7.5 Antenna requirements .....................................................................................................................................................27 8 Emission tests according to 47CFR part 15 subpart B requirements.............................................................................28 8.1 Conducted emissions ......................................................................................................................................................28 8.2 Radiated emission measurements ..................................................................................................................................32 9 APPENDIX A Test equipment and ancillaries used for tests..........................................................................................37 10 APPENDIX B Measurement uncertainties ......................................................................................................................38 11 APPENDIX C Test laboratory description .......................................................................................................................39 12 APPENDIX D Specification references ...........................................................................................................................39 13 APPENDIX E Test equipment correction factors ............................................................................................................40 14 APPENDIX F Abbreviations and acronyms ....................................................................................................................47 Report ID: ROSRAD_FCC.21191_rev1.doc Date of Issue: 11/23/2010 Page 3 of 47 1 Applicant information Client name: Rosslare Enterprises Ltd. Address: Flat 12, 9 Floor, Wing Fat Ind. Bldg., 12 Wang Tai Road, Kowloon Bay, Kowloon, Hong Kong Telephone: +852 2795 5630 Fax: +852 2795 1508 E-mail: [email protected] Contact name: Mr. Leonid Beckman 2 Equipment under test attributes Product name: Wireless access control interface Far unit Product type: Transceiver…

Text truncated - open the document above for the full version.

Test Setup Photos

Rosslare Enterprises Ltd. FCC ID:GCD-MD-W11FGR Page 1 of 7 SETUP PHOTOGRAPHS This document contains 6 photographs Rosslare Enterprises Ltd. FCC ID:GCD-MD-W11FGR Page 2 of 7 Photograph No.1 Setup for spurious emission measurements in the anechoic chamber below 30 MHz Rosslare Enterprises Ltd. FCC ID:GCD-MD-W11FGR Page 3 of 7 Photograph No.2 Setup for radiated emission measurements in the anechoic chamber from 30 to 1000 MHz Rosslare Enterprises Ltd. FCC ID:GCD-MD-W11FGR Page 4 of 7 Photograph No.3 Setup for spurious emission measurements in the anechoic chamber above 1000 GHz Rosslare Enterprises Ltd. FCC ID:GCD-MD-W11FGR Page 5 of 7 Photograph No.4 Setup for radiated emission measurements in the anechoic chamber, EUT close view Rosslare Enterprises Ltd. FCC ID:GCD-MD-W11FGR Page 6 of 7 Photograph No.5 Setup for periodic operation measurements Rosslare Enterprises Ltd. FCC ID:GCD-MD-W11FGR Page 7 of 7 Photograph No.6 Setup for conducted emission measurements on AC power lines

Contact Information

Applicant

Ilan Ozer(Director)
[email protected]+852-2795-5630Fax: +852-2795-1508

Technical Contact

Hermon Laboratories Ltd.Michael Nikishin
+972 4626 8440

Harakevet Industrial zone · Binyamina · Israel

Test Firm

Hermon Laboratories Ltd.Alexander Usoskin
[email protected]972-4628-8001Fax: 972-4628-8277

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.32 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from Rosslare Enterprises Ltd

Multi-Smart Readers - FCC ID GCD-AYK35 - Rosslare Enterprises Ltd
GCD-AYK35

Multi-Smart Readers

Aug 01, 2021

Equipment Class

DTS - Digital Transmission System
Advanced Wireless Security Panels - FCC ID GCD-HLX24TH - Rosslare Enterprises Ltd
GCD-HLX24TH

Advanced Wireless Security Panels

Jan 27, 2016

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Advanced Wireless Security Panels - FCC ID GCD-HLX24TG - Rosslare Enterprises Ltd
GCD-HLX24TG

Advanced Wireless Security Panels

Jan 27, 2016

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Reader - FCC ID GCDAYXX0 - Rosslare Enterprises Ltd
GCDAYXX0

Reader

Sep 20, 2015

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Reader - FCC ID GCDAYQX0 - Rosslare Enterprises Ltd
GCDAYQX0

Reader

Sep 20, 2015

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz