DENON/RC-8000EXHIBIT D - 1 EXHIBIT D [Ref: RSP-100 2.4(c)] " Photographs " DENON/RC-8000EXHIBIT D - 2 Fig. D-1 Top View of RC-8000 DENON/RC-8000EXHIBIT D - 3 Fig. D-2 Bottom View of RC-8000 Label LabelLabel Label (Certification Number) ( Certification Number)(Certification Number) ( Certification Number) DENON/RC-8000EXHIBIT D - 4 Fig. D-3 Top View of Main Unit of RC-8000 DENON/RC-8000EXHIBIT D - 5 Fig. D-4 Bottom View of Main Unit of RC-8000 Wire Antenna Wire AntennaWire Antenna Wire Antenna RF Unit RF UnitRF Unit RF Unit DENON/RC-8000EXHIBIT D - 6 Fig. D-5 Top View of RF Unit DENON/RC-8000EXHIBIT D - 7 Fig. D-6 Bottom View of RF Unit
DENON/RC-8000EXHIBIT D - 1 EXHIBIT F : FCC ID Label and Label Location Label LabelLabel Label (Certification Number) ( Certification Number)(Certification Number) ( Certification Number)
JAPAN QUALITY ASSURANCE ORGANIZATION 21-25, KINUTA 1-CHOME, SETAGAYA-KU, TOKYO 157-8573 JAPAN PHONE (03) 3416-0111, TELEX 242-2531 JQA J FAX (03) 3416-9691 JQA APPLICATION NO.: 400-00003 Issue Date : April 18, 2000 Page 1 of 28 EMI TEST REPORT JQA APPLICATION NO. : 400-00003 Model No. : RC-8000 Type of Equipment : Remote Transmitter Regulations Applied : CFR 47 FCC Rules and Regulations Part 15 FCC ID : GT3CSC001 Applicant : SMK Corporation Address : 5-5, Togoshi 6-chome, Shinagawa-ku, Tokyo 142-8511, Japan Manufacture : SMK Corporation Address : 5-5, Togoshi 6-chome, Shinagawa-ku, Tokyo 142-8511, Japan Received date of EUT : April 3,2000 Final Judgment : Passed TEST RESULTS IN THIS REPORT are obtained in use of equipment that is traceable to Electrotechnical Lab. of MITI Japan and Communications Research Lab. of MPT Japan. The test results only respond to the tested sample. It is not allowed to copy this report even partly without the allowance of the JQA EMC Engineering Dept. Testing Div. C O P Y JQA Application No. :400-00003 FCC ID :GT3CSC001 Model No. :RC-8000 Issue Date :April 18, 2000 Standard :CFR 47 FCC Rules Part 15 Page 2 of 28 JQA QUALITY ASSURANCE ORGANIZATION TABLE OF CONTENTS Page 1 Documentation 1.1 Test Regulation 3 1.2 General Information 3 1.3 Test Condition 4 โ 7 1.4 EUT Modifications / Deviation from Standard 8 1.5 Test results 9 1.6 Summary 10 1.7 Test Configuration / Operation of EUT 11 1.8 EUT Arrangement(Drawing) 12 1.9 Preliminary Test and Test-setup (Drawings) 13 โ 17 1.10 EUT Arrangement (Photographs) 18 - 19 2 Test Data 2.1 AC Power Line Conducted Emission 0.45 MHz โ 30 MHz N/A 2.2 Radiated Emission (Electric Field) 20 โ 25 2.3 Frequency Stability N/A 2.4 Occupied Bandwidth 26 โ 28 C O P Y JQA Application No. :400-00003 FCC ID :GT3CSC001 Model No. :RC-8000 Issue Date :April 18, 2000 Standard :CFR 47 FCC Rules Part 15 Page 3 of 28 JQA QUALITY ASSURANCE ORGANIZATION 1 DOCUMENTATION 1.1 TEST REGULATION FCC Rules and Regulations Part 15 Subpart A and C (June 23, 1989) Intentional Radiators Test procedure : AC power line conducted emission, radiated emission, frequency stability and occupied bandwidth tests were performed according to the procedures in ANSI C63.4-1992. 1.2 GENERAL INFORMATION 1.2.1 Test facility : 1) Test Facility located at EMC Engineering Dept. Testing Div. : No.2 and 3 Anechoic Chambers( 3 meters Site ) FCC filing No. : 31040/SIT 1300F2 2) EMC Engineering Dept. Testing Div. is recognized under the National Voluntary Laboratory accreditation Program for satisfactory compliance established in title 15, Part 285 Code of Federal Regulations. NVLAP Lab Code : 200189-0 (Effective through : June 30, 2000) 1.2.2 Description of the Equipment Under Test (EUT) : 1) Type of Equipment : Remote Transmitter 2) Product Type : Pre-Prototype 3) Category : Security/Remote Control Transmitter 4) EUT Authorization : Certification 5) FCC ID : GT3CSC001 6) Trade Name : DENON 7) Model No. : RC-8000 8) Operating Frequency Range : 304.3 MHz to 315 MHz 9) Highest Frequency Used in the EUT : 315 MHz 10) Serial No. : None 11) Date of Manufacture : None 12) Power Rating : DC 6.0(Battery) 13) EUT Grounding : None 1.2.3 Definitions for symbols used in this test report : x - indicates that the listed condition, standard or equipment is applicable for this report. - indicates that the listed condition, standard or equipment is not applicable for this report. C O P Y JQA Application No. :400-00003 FCC ID :GT3CSC001 Model No. :RC-8000 Issue Date :April 18, 2000 Standard :CFR 47 FCC Rules Part 15 Page 4 of 28 JQA QUALITY ASSURANCE ORGANIZATION 1.3 TEST CONDITION 1.3.1 The measurement of the AC Power Line Conducted Emission - was performed in the following test site. x - was not applicable. Test location : Safety Testing Center EMC Engineering Dept. Testing Div. 21-25, Kinuta 1-chome, Setagaya-ku, Tokyo 157-8573, Japan - Shielded Enclosure - Anechoic Chamber No. 2 (portable Type) Used test instruments : Type Model No. Manufacturer Serial No. Last Cal. Interval - Test Receiver ESH-2 Rohde & Schwarz 880370/016 Sep. 1999 1 Year - Test Receiver ESH-3 Rohde & Schwarz 881460/035 May 1999 1 Year - Test Receiver ESH-3 Rohde & Schwarz 881460/030 Jun. 1999 1 Year - LISN(for Peripheral) KNW-407 Kyoritsu Electrical 8-833-6 Apr. 1999 1 Year - LISN(for EUT) KNW-407 Kyoritsu Electrical 8-855-2 Apr. 1999 1 Year - LISN KNW-407 Kyoritsu Electrical 8-757-1 Apr. 1999 1 Year - RF Cable 3D-2W Fujikura 155-21-005E0 Apr. 1999 1 Year - RF Cable 3D-2W Fujikura 155-21-006E0 Apr. 1999 1 Year - 50ohm Termination - SUHNER 154-06-501E0 Jan. 2000 1 Year - 50ohm Termination - SUHNER 154-06-502E0 Jan. 2000 1 Year C O P Y JQA Application No. :400-00003 FCC ID :GT3CSC001 Model No. :RC-8000 Issue Date :April 18, 2000 Standard :CFR 47 FCC Rules Part 15 Page 5 of 28 JQA QUALITY ASSURANCE ORGANIZATION 1.3.2 The measurement of the Radiated Emission(30 MHz โ 1000 MHz) x - was performed in the following test site. - was not applicable. Test location : Safety Testing Center EMC Engineering Dept. Testing Div. 21-25, Kinuta 1-chome, Setagaya-ku, Tokyo 157-8573, Japan x - Anechoic Chamber No. 2 (3 meters) - Anechoic Chamber No. 3 (3 meters) Validation of Site Attenuation : 1) Last Confirmed Date :March, 2000 2) Interval :1 year Used test instruments : Type Model No. Manufacturer Serial No. Last Cal. Interval - Test Receiver ESV Rohde & Schwarz 872148/039 May 1999 1 Year - Test Receiver ESVS10 Rohde & Schwarz 826148/002 Jun. 1999 1 Year x - Test Receiver ESVP Rohde & Schwarz 881487/004 May 1999 1 Year - Test Receiver ESVP Rohde & Schwarz 881487/005 Dec. 1999 1 Year x - Antenna KBA-511A Kyoritsu Electrical 0-170-1 Nov. 1999 1 Year - Antenna KBA-511A Kyoritsu Electrical 0-201-13 Nov. 1999 1 Year x - Antenna KBA-611 Kyoritsu Electrical 0-147-14 Nov. 1999 1 Year - Antenna KBA-611 Kyoritsu Electrical 0-210-5 Nov. 1999 1 Year x - RF Cable 5D-2W Fujikura 155-21-001E0 Feb. 2000 1 Year - RF Cable 5D-2W Fujikura 155-21-002E0 Feb. 2000 1 Yโฆ
Text truncated - open the document above for the full version.
21-15, Kinuta 1-chome, Setagaya-ku ยท Tokyo ยท Japan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | - | 0.315 MHz - 0.315 MHz | - |
Rear Remote Controller
Equipment Class
DTS - Digital Transmission System
Bluetooth Low Energy Module
Equipment Class
DTS - Digital Transmission System
Bluetooth Smart Module
Equipment Class
DTS - Digital Transmission System
neyya
Equipment Class
DTS - Digital Transmission System
ZigBee RF4CE module
Equipment Class
DTS - Digital Transmission System