Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
User’s Manual ProScribe CV 12 inch Wireless Thin Client (Rev. 0.01 ) W ProScribe CV Copyright © This manual is copyrighted with all rights reserved. Under the copy rights law, this manual may not be copied, in whole or part, without written consent of Philips. Under the law, copying includes translating into another language or format. The monitor described in this manual, has been certified/registered by the safety agencies/regulatory authorities as model n° : CMPD1CV FCC Notice This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and , if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, while can be determined by turning the equipment Off and On, the user is encouraged to try to correct the interference by one or more of the following measures. - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio TV technician for help. Modification The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by the manufacturer may void the user’s authority to operate the equipment. Cables Connections to this device must be made with shielded signals cables with metallic RFI/EMI connector hoods to maintain compliance with FCC Rules and Regulations. The lighting flash with arrowhead symbol is intend to alert the user of the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be sufficient magnitude to constitute a risk of electrical shock to people. The exclamation mark is intended to alert the user of the presence of important operating and maintenance (servicing) instructions in literature accompanying the appliance. CAUTION RISK OF ELECTRICAL SHOCK DO NOT OPEN ATTENTION RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR CAUTION: TO AVOID THE RISK OF ELECTRICAL SHOCK. DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL WARNING: THE ENCLOSURE HAS TO BE CHECKED UPON COLLISION DAMAGE; REFER TO QUALIFIED SERVICE PERSONNEL PROSCRIBE MONITOR DO NOT HAVE APPLIED PARTS, AND ARE NOT INTENDED TO BE CONNECTED TO A PATIENT CIRCUIT. ProScribe CV RF Exposure Statement This EUT is compliance with SAR for general population / uncontrolled exposure limits in ANSI/IEEE C95.1-1999 and had been tested in accordance with the measurement methods and procedures specified in OET bulletin 65 Supplement C. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the pos- sibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 1.5 cm during normal operation. This device and its antenna (s) must not be co-located or operating in conjunction with any other antenna or transmitter. ProScribe CV INTRODUCTION A ruggedized wireless thin client display The Philips ProScribe is a ruggedized wireless thin client display, released with Windows XP embedded, both for ITE and medical applications. The ProScribe is designed upon PMS CV requirements. It makes use of wireless technology and thin-client computing to allow workers to access applications stored on a central server as if they were sitting behind their desktop monitor. Its ruggedized design, compact size and touch-screen interface makes it also a perfect solution for point of information and system control applications too. Main features With a 1GHz VIA-based x86 processor as its engine and Microsoft Windows XP embedded as operation system, Other main features are: • 12.1 inch TFT-LCD with Touch-screen functionality; • 1024x768 resolution (XGA); • display emulated keyboard; • integrated WiFi™ 802.11b/g wireless LAN • lightweight (2,17kg); Rugged design for the toughest environments The ProScribe is compliant with industry standards for liquid and dust resistance (IP1) and is also physically tough, with a highly durable build capable of surviving a drop from as high as one meter onto a concrete surface. Easy to integrate, deploy and maintain The ProScribe allows users to take full benefit of thin-client computing where data and applications are kept on a server where they can be managed centrally, more securely and at lower total cost. Nearly no downtime is incurred in case a device is lost or stolen: a new ProScribe straight from the box allows a user to resume an interrupted login session exactly as before. Server access is provided by one of the three pre-installed thin clients, Microsoft Remote Desktop Protocol (RDP), Internet Explorer or Citrix Independent Computer Architecture (ICA). Flexible to fit any vertical application The ProScribe offers a full suite of utilities and multiple plug-and-play interfaces for easy integration into any type of IT environ- ment, and specifically: - Full-size XGA resolution: 1024 x 768 - Basic version with 512MB RAM and 1GB flash memory - Two USB ports - An 100Mbps RJ-45 Ethernet interface Approved for medical applications The Proscribe meets the medical safety and electromagnetic requirements of IEC 60601-1 and IEC 60601-1-2, if used with power supply unit certified according to the same standard (Medical Grade PSU; check the d.c. supply connector pin-configuration of the PSU before connecting it to the unit). Unit shall be used, with power supply. NOTES: 1 - WiFi a…
Text truncated - open the document above for the full version.
DICHIARAZIONE DI CONFORMITA’ / FIMI SRL Subject: Application Form for FCC ID: GZM802130 I certify that I am authorized to sign this application. All of the statements herein and the exhibits attached hereto, are true and correct to the best of my knowledge and belief. In accepting a Grant of Equipment Authorization issued by the TCB, under the authority of the FCC, as a result of the representations made in this application, the applicant is responsible for (1) labelling the equipment with the exact FCC ID specified in this application, (2) compliance statement labelling pursuant to the applicable rules, and (3) compliance of the equipment with the applicable technical rules. If the applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. Authorizing an agent to sign this application, is done solely at the applicant’s discretion; however, the applicant remains responsible for all statements in this application. If an agent has signed this application on behalf of the applicant, a written letter of authorization which includes information to enable the agent to respond to the above Section 5301 (Anti-Drug Abuse) Certification statement has been provided by the applicant. It is understood that the letter of authorization must be submitted to the FCC upon request, and that the FCC reserves the right to contact the applicant directly at any time. FIMI SRL Date: 14-06-2007 Carlo D’Adda (R&D Director)
Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: This letter is to comply with Sections 0.457 and 0.459 pertaining to confidential material. FIMI SRL would like the following documents regarding this submission for FCC ID: GZM802130 to be kept confidential. Documents: 1. Block diagram 2. Operational description 3. Schematic diagrams The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want these documents to be accessible to the general public. Sincerely, Date: 15/06/2007 Carlo D’Adda (R&D Director)
AN000628001001 *AN000628001001* TSM121XE-M 991932051451 *991932051451*
E Fimi S.r.l. Reliability Engineering W S&R * Department REF.: Issue date: 07-06-2007 Sheet 1 of 3 PROSCRIBE CV Mod. Numb. CMPD12CV (Product code: 9919 320 514519) Photo 1 – Bo LCD Panel Photo 2 Photo 3 Photo 4 Photo 5 Photo 6 - LCD PANEL BRACKET Switch board Control board Microphone MOTHER BOARD Loudspeaker Loudspeaker WI-FI BOARD USB BOARD INVERTER FOR LCD PANEL D-SUB BOARD WI FI led S&R * Department REF.: Issue date: 07-06-2007 Sheet 2 of 3 Photo 7 - MAIN BOARD front Photo 8 – MAIN BOARD rear Photo 9 – WI-FI BOARD front Photo 10 - WI-FI BOARD rear Photo 11 – USB BOARD front Photo 12 - USB BOARD front FLASH DISK S&R * Department REF.: Issue date: 07-06-2007 Sheet 3 of 3 Photo 13 – D-SUB BOARD front Photo 14– D-SUB BOARD rear Photo 15 – CONTROL BOARD front Photo 16 – CONTROL BOARD rear Photo 17 - LCD PANEL – rear side Photo 17 - LCD PANEL – rear side – Label EMI SHIELD TOUCH PANEL CONNECTOR BACK LIGHT CONNECTOR BACK LIGHT CONNECTOR
©2007 SPORTON International Inc. SAR Testing Lab This report shall not be reproduced except in full, without the written approval of Sporton. Rev. 01 FCC SAR Test Report Test Report No ﹕ FA5O2116-02-1-2-01 Specific Absorption Rate (SAR) Test Report for MoBitS Electronics, Inc. on the Web Pad Report No. : FA5O2116-02-1-2-01 Trade Name : MoBits / PHILIPS Model Name : CMPD12CV FCC ID : RUJ-LR802UWG Date of Testing : Aug. 01, 2007 Date of Report : Aug. 02, 2007 Date of Review : Aug. 02, 2007 The test results refer exclusively to the presented test model / sample only. Without written approval of SPORTON International Inc., the test report shall not be reproduced except in full. Report Version: Rev. 01 SPORTON International Inc. 6F, No.106, Sec. 1, Hsin Tai Wu Rd., Hsi Chih, Taipei Hsien, Taiwan, R.O.C. ©2007 SPORTON International Inc. SAR Testing Lab This report shall not be reproduced except in full, without the written approval of Sporton. Rev. 01 Tel: 886-2-2696-2468 Fax: 886-2-2696-2255 FCC SAR Test Report Test Report No ﹕ FA5O2116-02-1-2-01 Table of Contents 1. Statement of Compliance ........................................................................................................................................................... 1 2. Administration Data .................................................................................................................................................................... 2 2.1 Testing Laboratory ........................................................................................................................................................... 2 2.2 Detail of Applicant............................................................................................................................................................ 2 2.3 Detail of Manufacturer ..................................................................................................................................................... 2 2.4 Application Detail............................................................................................................................................................. 2 3. Scope ........................................................................................................................................................................................... 3 3.1 Description of Device Under Test (DUT).......................................................................................................................... 3 3.2 CMPD12CV Feature Spec............................................................................................................................................... 4 3.3 Product Photo.................................................................................................................................................................. 5 3.4 Applied Standards: .......................................................................................................................................................... 6 3.5 Device Category and SAR Limits .................................................................................................................................... 7 3.6 Test Conditions ................................................................................................................................................................ 7 3.6.1 Ambient Condition:............................................................................................................................................ 7 3.6.2 Test Configuration: ............................................................................................................................................ 7 4. Specific Absorption Rate (SAR)................................................................................................................................................. 8 4.1 Introduction...................................................................................................................................................................... 8 4.2 SAR Definition ................................................................................................................................................................. 8 5. SAR Measurement Setup............................................................................................................................................................ 9 5.1 DASY4 E-Field Probe System ....................................................................................................................................... 10 5.1.1 ET3DV6 E-Field Probe Specification................................................................................................................11 5.1.2 ET3DV6 E-Field Probe Calibration...................................................................................................................11 5.2 DATA Acquisition Electronics (DAE) .............................................................................................................................. 12 5.3 Robot............................................................................................................................................................................. 13 5.4 Measurement Server ..................................................................................................................................................... 13 5.5 SAM Twin Phantom ....................................................................................................................................................... 13 5.6 Data Storage and Evaluation ......................................................................................................................................... 15 5.6.1 Data Storage .......................................................................................................................…
Text truncated - open the document above for the full version.
FCC.TR. TEST REPORT 07.232 Prima Ricerca & Sviluppo Srl soggetta a direzione e coordinamento da parte della Giovanni Maspero & C. S.p.A. – C.I. 02634780130 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. FISC. e N. R.I. CO 02635860139 Sede operativa : Laboratori Via Campagna, 92 22020 Faloppio fraz. Gaggino (CO) Tel. +39 03135000.11 Fax +39 031991309Fax +39 031991309 Edition: 1.0 Issue date: 23/03/2007 sheet 1 of 14 EQUIPMENT UNDER TEST : APPARECCHIO IN PROVA : PROSCRIBE CV CMPD12CV REFERENCE STANDARDS : NORME DI RIFERIMENTO : 47 CFR FCC Part 15 Subpart C § 15.247 CUSTOMER: RICHIEDENTE: • Dept. / Firm : Ente / Società’: FIMI S.R.L. • Mr.: Sig.: MARINO FUSCO • Address: Indirizzo: VIA SAUL BANFI, 1 – 21047 SARONNO (VA) - ITALY • Tel. : Telefono : ++39 02/96175248 • Telefa Fax : ++39 02/96175296 • E-mail: e-mail [email protected] Site of test execution: Via Campagna, 92 - 22020 Gaggino Faloppio (CO) - Italy Località esecuzione prove: Date of test samples receipt: 21/02/2007 Date of start test: 22/02/2007 Data ricevimento campioni: Data inizio prove: Date of end test: 22/03/2007 Data fine prove: Witness to the test: Presenti alle prove: Signature of the engineers: Firma esecutore prove: Signature of the Laboratory Director: Firma Direttore Laboratori: Nobody / Nessuno ......................................................... .......................................................... Massimo Maltempi .......................................................... G. Molteni The test results recorded in this Test Report are exclusively referred to the tested samples. I risultati del presente rapporto di prova si riferiscono esclusivamente al campione sottoposto a prova. Reproduction of this EMC-Test Report in whole or in part is prohibited without the written authorization of the Laboratory Director La riproduzione di questo Rapporto in modo parziale o totale è PROIBITO senza l’autorizzazione scritta della Direzione del Laboratorio FCC.TR. TEST REPORT 07.232 Prima Ricerca & Sviluppo Srl soggetta a direzione e coordinamento da parte della Giovanni Maspero & C. S.p.A. – C.I. 02634780130 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. FISC. e N. R.I. CO 02635860139 Sede operativa : Laboratori Via Campagna, 92 22020 Faloppio fraz. Gaggino (CO) Tel. +39 03135000.11 Fax +39 031991309Fax +39 031991309 Edition: 1.0 Issue date: 23/03/2007 sheet 2 of 14 0. CONTENTS Page Rev Date 0. CONTENTS ............................................................................................... 2 1. TECHNICAL INFORMATION OF EQUIPMENT UNDER TEST (EUT) ...... 3 1.1 Identification ......................................................................................... 3 1.2 Technical data ...................................................................................... 3 1.3 Modifications incorporated in E.U.T...................................................... 4 1.4 Ports identification ............................................................................... 4 1.5 Auxiliary equipment ............................................................................. 5 2. TEST CONDITIONS .................................................................................. 5 2.1 Operating test modes and test conditions ........................................... 5 2.2 Test overview ....................................................................................... 5 3. REFERENCE STANDARD FOR PERFORMED TESTS ........................... 6 4. Summary of test results ............................................................................. 6 4.1 Emission tests ...................................................................................... 6 Note: ......................................................................................................... 6 5. TEST RESULTS ........................................................................................ 7 6. EUT TECHNICAL DOCUMENTATION.................................................... 13 6.1 Wiring diagrams ................................................................................. 13 6.2 Technical manual............................................................................... 13 6.3 Photographic documentation.............................................................. 14 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 04/10/06 04/10/06 04/10/06 04/10/06 04/10/06 04/10/06 04/10/06 04/10/06 04/10/06 04/10/06 04/10/06 04/10/06 04/10/06 04/10/06 04/10/06 04/10/06 04/10/06 04/10/06 04/10/06 FCC.TR. TEST REPORT 07.232 Prima Ricerca & Sviluppo Srl soggetta a direzione e coordinamento da parte della Giovanni Maspero & C. S.p.A. – C.I. 02634780130 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. FISC. e N. R.I. CO 02635860139 Sede operativa : Laboratori Via Campagna, 92 22020 Faloppio fraz. Gaggino (CO) Tel. +39 03135000.11 Fax +39 031991309Fax +39 031991309 Edition: 1.0 Issue date: 23/03/2007 sheet 3 of 14 1. TECHNICAL INFORMATION OF EQUIPMENT UNDER TEST (EUT) 1.1 Identification Brand name: FIMI S.R.L Manufacturer: FIMI S.R.L Equipment : ProScribe CV CMPD12CV Serial number : Not present FCC ID : GZM802130 Country of manufacturer: ITALY 1.2 Technical data FCC class: 47 CFR FCC Part 15 Subpart C § 15.247 Product type: WLAN Radio type: Intentional transceiver Power type : Power adapter Modulation: DSS for IEEE 802.11b; OFDM for IEEE 802.11g Data Modulation : DSS (BPSK / QPSK / CCK) ; OFDM (BPSK / QPSK / 16QAM / 64 QAM) Data Rate (Mbps) : DSS (1 / 2 / 5.5 / 11) ; OFDM (6/ 9 / 12 / 18 / 24 / 36 / 48 / 54) Frequency range : 2400 – 2483.5 MHz Channel number : 11 Channel Band Width (99%) : 11b:14.04 MHz; 11g:16.40 MHz Conducted Output Power : 11b:18.11 dBm; 11g:12.79 dBm Carrier Frequency : Channel No.1: 2412 MHz Channel No.2: 2417 MHz Channel No.3: 2422 MHz Channel No.4: 2417 MHz Channel No.5: 2432 MHz Channel No.6: 2437 MHz Channel No.7: 2442 MHz Channel No.8: 2447 MHz Channel No.9: 2452 MHz Channel No.10: 2457 MHz …
Text truncated - open the document above for the full version.
FCC ID: RUJ-LR802UWG Report No.: RF940920L071Report Format Version 2.0.4 FCC TEST REPORT REPORT NO.: RF940920L07 MODEL NO.: LR802UWG RECEIVED: Sep. 20, 2005 TESTED: Sep. 22 ~ Oct. 28, 2005 ISSUED: Oct. 31,2005 APPLICANT: Qcom Technology Inc. ADDRESS: 7F,NO.178,MING CHUAN E. RD.SEC 3, TAIPEI TAIWAN R.O.C. ISSUED BY: Advance Data Technology Corporation LAB ADDRESS: No. 47, 14 th Ling, Chia Pau Tsuen, Lin Kou Hsiang 244, Taipei Hsien, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2 nd Rd., Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This test report consists of 75 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by CNLA, A2LA or any government agencies. The test results in the report only apply to the tested sample. 0528 ILAC MRA No. 2177-01 FCC ID: RUJ-LR802UWG Report No.: RF940920L072Report Format Version 2.0.4 TABLE OF CONTENTS 1.CERTIFICATION.........................................................................................................4 2.SUMMARY OF TEST RESULTS.................................................................................5 2.1MEASUREMENT UNCERTAINTY..............................................................................5 3.GENERAL INFORMATION.........................................................................................6 3.1 GENERAL DESCRIPTION OF EUT...........................................................................6 3.2 DESCRIPTION OF TEST MODES.............................................................................7 3.2.1 CONFIGURATION OF SYSTEM UNDER TEST.........................................................8 3.2.2 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL..............................9 3.2.3 GENERAL DESCRIPTION OF APPLIED STANDARDS...........................................11 3.2.4 DESCRIPTION OF SUPPORT UNITS......................................................................11 4. TEST TYPES AND RESULTS...................................................................................12 4.1 CONDUCTED EMISSION MEASUREMENT............................................................12 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT..........................................12 4.1.2 TEST INSTRUMENTS..............................................................................................12 4.1.3 TEST PROCEDURES..............................................................................................13 4.1.4 DEVIATION FROM TEST STANDARD.....................................................................13 4.1.5 TEST SETUP...........................................................................................................14 4.1.6 EUT OPERATING CONDITIONS..............................................................................14 4.1.7 TEST RESULTS.......................................................................................................14 4.2 RADIATED EMISSION MEASUREMENT.................................................................21 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT...............................................21 4.2.2 TEST INSTRUMENTS..............................................................................................22 4.2.3 TEST PROCEDURES..............................................................................................23 4.2.4 DEVIATION FROM TEST STANDARD.....................................................................24 4.2.5 TEST SETUP...........................................................................................................24 4.2.6 EUT OPERATING CONDITIONS..............................................................................24 4.2.7 TEST RESULTS.......................................................................................................25 4.3 6dB BANDWIDTH MEASUREMENT........................................................................39 4.3.1 LIMITS OF 6dB BANDWIDTH MEASUREMENT......................................................39 4.3.2 TEST INSTRUMENTS..............................................................................................39 4.3.3 TEST PROCEDURE.................................................................................................40 4.3.4 DEVIATION FROM TEST STANDARD.....................................................................40 4.3.5 TEST SETUP...........................................................................................................40 4.3.6 EUT OPERATING CONDITIONS..............................................................................40 4.3.7 TEST RESULTS.......................................................................................................41 4.4 MAXIMUM PEAK OUTPUT POWER........................................................................47 4.4.1 LIMITS OF MAXIMUM PEAK OUTPUT POWER MEASUREMENT.........................47 FCC ID: RUJ-LR802UWG Report No.: RF940920L073Report Format Version 2.0.4 4.4.2 INSTRUMENTS........................................................................................................47 4.4.3 TEST PROCEDURES..............................................................................................48 4.4.4 DEVIATION FROM TEST STANDARD.....................................................................48 4.4.5 TEST SETUP...........................................................................................................48 4.4.6 EUT OPERATING CONDITIONS..............................................................................48 4.4.7 TEST RESULTS.......................................................................................................49 4.5 POWER SPECTRAL DENSITY MEASUREMENT....................................................50 4.5.1 LIMITS OF POWE…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 71.00 mW |

RFID Computing Platform
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
DIGITAL TRANSMISSION SYSTEM
Equipment Class
NII - Unlicensed National Information Infrastructure TX
WEB PAD
Equipment Class
DTS - Digital Transmission System
Web PAD
Equipment Class
DTS - Digital Transmission SystemJBP - Part 15 Class B Computing Device Peripheral
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral