Application Details

Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Date of Grant
Jan 17, 2000
Application Purpose
Original Equipment
Date of Application
Dec 06, 1999
Equipment Note
USB Modem
Company
Puretek Industrial Co Ltd
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

↗
↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

USB Modem USB Modem USB Modem USB Modem USB Modem User’ User’ User’ User’ User’ s Manual s Manual s Manual s Manual s Manual VV VV V erer erer er .. .. . A A A A A 3050 - 99103050 - 9910 3050 - 99103050 - 9910 3050 - 9910 i Pan-European ApprovalPan-European Approval Pan-European ApprovalPan-European Approval Pan-European Approval The equipment has been approved in accordance with Council Decision 98/482/EC for pan- European single terminal connection to the public switched telephone network (PSTN). However, due to differences between the individual PSTNs provided in different countries, the approval does not, of itself, give an unconditional assurance of successful operation on every PSTN network termination point. In the event of problems, you should contact your equipment supplier in the first instance. WW WW W arning Notice to Aarning Notice to A arning Notice to Aarning Notice to A arning Notice to A ustralian Userustralian User ustralian Userustralian User ustralian User ss ss s All telecommunications devices are required to be la belled with a Telecommunications Compliance Label, ensuring their compliance with ACA Technical Standards. To ensure continuing compli- ance to A C A Technical Standards, please ensure the following AT commands are maintained: ATB0(ITU/CCITT operation) AT&G(No Guard tone) AT&P1(33/36 pulse dial make/break ratio) ATS0=0(No answer or answer greater than 1ring) or ATS0>1 ATS6=N(Blind dial delay - acceptable range is 2-5 seconds) ATS11=95(DTMF period between 70- 255ms) ii A total of 3 calls attempts are allowed to a telephone number, with a minimum period between calls of 2 seconds: if the call doesn‘t connect after 3 attempts, 30 minutes must expire before automatic redialling may be initiated. Failure to set the modem (and any associated communications software) to the above setting may result in the modem being non-compliant with A C A Technical Standards. Under these circumstance a permit would no longer be valid, with the user subject to significant penalties under the Telecommunications Act. The modem card must only be used in a data terminal equipment (DTE) e.g. computer, that has a screw down cover /lid. As unsafe voltages (TNV) exist on the modem card, disconnect the modem card from the telephone line while the cover (lid) of the DTE (computer) is removed. 1. While installing the internal modem card, please ensure there is at least 2mm of air gap between the PCB card and other components in the DTE. 2. For Safety reasons, only connect a Telephone marked with a Telecommunications Compliance Label to the phone port. 3. For Safety reasons, only connect equipment with a Telecommunications Compliance CautionCaution CautionCaution Caution !! !! ! Label. This includes customer equipment previously labelled, permitted or certified. Notice for New Zealand UsersNotice for New Zealand Users Notice for New Zealand UsersNotice for New Zealand Users Notice for New Zealand Users § The grant of a Telepermit for a device in no w ay indicates Telecom acceptance of responsibility for the correct operation of that device under all operating conditions. In particular the higher speeds at which this modem is capable of operating cannot always be expected on network designed to delivery voice telephony be customers. Failure to operate should not be reported as a fault to Telecom. § In addition to satisfactory line conditions a modem can only work properly if: - It is compatible with the modem at the other end of the call and - The application using the modem is compatible with the application at the other end of the call. E.g. accessing the Internet requires suitable software in addition to a modem. § This equipment shall not be used in any manner whichcould constitute a nuisance to other Telecom customers. § Some parameters required for compliance with Telecom’s PTC Specifications are iii dependent on the equipment (PC) associated with this modem. The associated equipment shall be set to operate within the following limits for compliance with Telecom Specifications: - Not more than a total of 10 call attempts shall be made to the same number for any single manual call initiation within a 30 minutes period. - There shall be at least 60 seconds between call attempts to the same number. - Automatic calls to different numbers shall be not less than 5 seconds apart. Immediately disconnect this equipment should it become physically damaged, and arrange for its disposal repair. § The correct settings for use with this modem in New Zealand are as following: ATB0(CCITT operation) AT&G2(1800 Hz guard tone) AT&P1(Decadic dialling make- break ratio=33% /67%) ATS0=0(not auto answer) ATS11=65(DTMF dialling on/off duration = 65 ms) ATX2(dial tone detect, but not (U.S.A) can progress detect) iv § When used in the Auto Answer mode, the S0 register must be set with a value between 2 and 10. This ensures: - A person calling your modem will hear a short burst of ringing before the modem answers. This confirms that the call has been successfully switched through the network. - Caller identification information (which occurs between the first and second ring cadances) is not destroyed. § This equipment does not fully meet Telecom’s impedance requirements. Performance limitations may occur when used in conjunction with some parts of the network. Telecom will accept no responsibility should difficulties arise in such circumstances. § It is recommended that this equipment be disconnected from the Telecom line during electrical storms. § When relocating the equipment, always disconnect the Telecom line connection before the power connection, and reconnect the power first. Please note that fault callouts caused by any of the above causes may incur a charge from Telecom. v General ConditionsGeneral Conditions General ConditionsGeneral Conditions General Conditions As required by PTC 100, please ensure that this office is advised of any changes to the specifica- tions of these products which might aff…

Text truncated - open the document above for the full version.

External Photos

FCC ID : H52PT-3050FRONT SIDE OF EUT Number 1 9O1804-1.JPG FCC ID : H52PT-3050REAR SIDE OF EUT Number 2 9o1804-2.JPG FCC ID : H52PT-3050Mechanical Construction Number 3 9o1804-3.JPG FCC ID : H52PT-3050Mechanical Construction Number 4 9o1804-4.JPG FCC ID : H52PT-3050Front side of main board Number 5 9o1804-5.JPG FCC ID : H52PT-3050Rear side of main board Number 6 9o1804-6.JPG FCC ID : H52PT-3050Reference Modification No.1 Number 7 9o1804-7.JPG 1

ID Label/Location Info

EXHIBIT A. FCC ID LABEL FCC ID:H52PT-3050 The next page shows the location of FCC ID on EUT. The following statement will be placed in the User’s Manual. EUT : USB MODEM FCC ID : H52PT-3050 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions :(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: 1. Material and thickness:2 mi 1, white 2. Glue information : Permanent adhesive 3. Text color is black 4. Scale: 1:1

ID Label/Location Info

FCC ID LABEL LOCATION

Test Report

FCC TEST REPORTReport No. : F9O1804 SPORTON International Inc. FCC ID: H52PT-3050 TEL : 886-2-2696-2468Page No.: 1 of 22 FAX : 886-2-2696-2255Issued Date : Oct. 27, 1999 FCC TEST REPORT for CISPR PUB. 22 Class B Equipment: USB MODEM Model No.: PT-3050 FCC ID: H52PT-3050 Filing Type: Original Grant Applicant: PURETEK INDUSTRIAL CO., LTD. 4F, NO. 12, LANE 235, PAO-CHIAO RD., HSINTIEN CITY, TAIPEI, TAIWAN, R.O.C.  The test result refers exclusively to the test presented test model / sample.  Without the written authorization of the test lab., the Test Report may not be copied.  Certificate or Test Report must not be used by the applicant to claim the product in this test report endorsement by NVLAP or any agency of U.S. government. SPORTON International Inc. 6F, No.106, Sec. 1, Hsin Tai Wu Rd., Hsi Chih, Taipei Hsien, Taiwan, R.O.C. FCC TEST REPORTReport No. : F9O1804 SPORTON International Inc. FCC ID: H52PT-3050 TEL : 886-2-2696-2468Page No.: 2 of 22 FAX : 886-2-2696-2255Issued Date : Oct. 27, 1999 Table of Contents CERTIFICATE OF COMPLIANCE ....................................................................................................................... 3 1. General Description of Equipment under Test ............................................................................................ 4 1.1. Applicant .................................................................................................................................................................................... 4 1.2. Manufacturer .............................................................................................................................................................................. 4 1.3. Basic Description of Equipment under Test ................................................................................................................................ 4 1.4. Feature of Equipment under Test ............................................................................................................................................... 4 2. Test Configuration of Equipment under Test .............................................................................................. 5 2.1. Test Manner ............................................................................................................................................................................... 5 2.2. Description of Test System ......................................................................................................................................................... 5 2.3. Connection Diagram of Test System .......................................................................................................................................... 7 3. Test Software .................................................................................................................................................. 7 4. General Information of Test ........................................................................................................................... 9 4.1. Test Facility ................................................................................................................................................................................ 9 4.2. Standard for Methods of Measurement....................................................................................................................................... 9 4.3. Test in Compliance with.............................................................................................................................................................. 9 4.4. Frequency Range Investigated ................................................................................................................................................... 9 4.5. Test Distance ............................................................................................................................................................................. 9 5. Test of Conducted Powerline ...................................................................................................................... 10 5.1. Major Measuring Instruments ................................................................................................................................................... 10 5.2. Test Procedures ....................................................................................................................................................................... 10 5.3. Typical Test Setup Layout of Conducted Powerline .................................................................................................................. 12 5.4. Test Result of AC Powerline Conducted Emission.................................................................................................................... 13 5.5. Photographs of Counducted Powerline Test Configuration ....................................................................................................... 14 6. Test of Radiated Emission ........................................................................................................................... 16 6.1. Major Measuring Instruments ................................................................................................................................................... 16 6.2. Test Procedures ....................................................................................................................................................................... 17 6.3. Typical Test Setup Layout of Radiated Emission ...................................................................................................................... 18 6.4. Test Result of Radiated Emission ............................................................................................................................................. 19 6.5. Photographs of Ra…

Text truncated - open the document above for the full version.

Test Report

FEDERAL COMMUNICATIONS COMMISSIONFCC ID:H52PT-3050 Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 U.S.A. Re: About the modification of USB MODEM Gentlemen: I, hereby, declare that all modification on the E.U.T., FCC ID: H52PT-3050, will be added or layout on the mass production products. Modifications are shown as below: 1. A ferrite core is added on the USB cable. (As the photo No.7) Sincerely yours Yu-Hong Lee R&D Manager

Contact Information

Applicant

Yu-Hong Lee(R & D Manager)
886 2 2910-1310Fax: 886 2 2916-1004

Technical Contact

SPORTON International Inc.Kathy Lin
[email protected]886-2-26962468

6F, No. 106, Sec. 1, Hsin Tai Wu Rd., Hsi Chin, · Taipei Hsien · Taiwan

Non-Technical Contact

SPORTON International Inc.Kathy Lin
[email protected]718-468-4260

Test Firm

Sporton International Inc.Kathy Lin
[email protected]886-2-26962468Fax: 886-2-26962255

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--

Other Applications from Puretek Industrial Co Ltd

Modem - FCC ID H52PT-3030 - Puretek Industrial Co Ltd
H52PT-3030

Modem

Oct 08, 2000

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
Modem - FCC ID H52PT-3032 - Puretek Industrial Co Ltd
H52PT-3032

Modem

Oct 05, 2000

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
CCD - FCC ID H52PT-6009 - Puretek Industrial Co Ltd
H52PT-6009

CCD

Oct 05, 2000

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
Modem - FCC ID H52PT-3036 - Puretek Industrial Co Ltd
H52PT-3036

Modem

Sep 27, 2000

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
Modem Card - FCC ID H52PT-3029 - Puretek Industrial Co Ltd
H52PT-3029

Modem Card

Sep 27, 2000

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral