Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
May 31, 2004
Application Purpose
Original Equipment
Date of Application
Apr 05, 2004
Equipment Note
Pendant Transmitter
Frequency Range
902.40000000 - 927.60000000
Company
Inovonics Wireless Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Parts List/Tune Up Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

EchoStream™ Select ES1223D Double-button pendant transmitter EchoStream™ Select ES1223S Single-button pendant transmitter Installation and Operation Manual - 03962B IMPORTANT NOTES iThese products are designed to be installed and maintained by professional security technicians. iProducts, unless specifically noted, are intended for indoor use. iManually test all products regularly. FEATURES iInovonics Wireless radio link, with selectable frequency bands. iThe ES1223S and ES1223D have water-resistant housings that protect the pendant when worn in the bathtub, shower, rain, or other environments where the pendant may be splashed with water or momentarily submerged. CHANGING THE BATTERY 1)Remove three screws from the back of the housing. 2)Make sure that the battery is inserted with the positive (+) terminal facing the indicated side of the holder. 3)After battery insertion, w ait 30 seconds, then press the Reset Button (LEDs will flash) to reset the transmitter to its most recent programming. 4)Replace back cover. See Caution below. Make sure that the Reset assembly is intact 5)Thoroughly test the unit before returning to service. Caution: Replacing back cover iDo not over-tighten screws when replacing the back cover. iCorrect torque is 1.5 inch-pounds. iBe careful not to damage the gasket material to preserve water-resistance capability. iTighten screws evenly for good seal. Discard old battery in accordance to the local laws and practices. Inovonics Wireless does not take responsibility for batteries that are not discarded properly. SELECTING OPERATING FREQUENCY 1)Determine the correct frequency setting for the area in which the ES1223 will be used. 2)Set Frequency Jumper as shown in Figure 4. Press reset button. REGISTERING TRANSMITTERS Transmitters must be registered with the system receiver in order to be monitored and supervised. Each trans- mitter has a unique factory-programmed identification number. Refer to the receiver installation instructions for details on registering a transmitter. 1) If the ES1223 housing is closed:when prompted by the receiver to "Reset Transmitter", press the Reset Button (Figure 1). 2) If the ES1223 housing is open:when prompted by the receiver to "Reset Transmitter", press the Reset button (Figure 3). Replace the ES1223 cover. Follow instructions to test the transmitter. Note: The ES1223 retains programming data in non-volatile memory. It does not require re-programming after loss of power. Follow “Changing the Battery” instructions to re-initialise the transmitter and restore programming. OPERATION To activate the ES1223S, press and hold the Activation Button for at least 1 second. To activate the ES1223D, press and hold both Activation Buttons for at least 1 second. Alarm signals are transmitted multiple times, and are indicated by the blinking Transmit LED. Holding the buttons results in continuous transmission. When either button is released, the FA223S/D will complete its alarm transmission, then will send an alarm restoral signal so that receiver devices configured for follower mode will return to their normal state. I I I I Figure 1: ES1223S Figure 3: Battery Installation Figure 2: ES1223D Figure 4: Frequency band Selection Wearing the ES1223S or ES1223D: Neck cord, Belt Clip or Wrist band The ES1223 can be carried in three convenient ways: iAround the neck as a pendant (standard). iOn a belt with the beltclip attachment (standard). iOn the arm with optional wristband accessory (ACC623Sor ACC623L). Neck Cord Safety WARNING: The neck cord provided with the ES1223S/D is designed for user safety. Substitution of stronger cords or chains may result in injury to the wearer. I TECHNICAL SPECIFICATIONS Dimensions:5.6 x 4.8 x 1.8 cm (2.2 x 1.9 x 0.72”) Operating temperature:0° to 60°C (32° to 140°F) Transmitter frequency range:Selectable for USA, Europe, Australia or New Zealand (see Figure 4) Preprogrammed check-in Interval: 12 minutes (EU, MF); 3 minutes (AU, NZ, US) Reset Button Reset Button © 2003 Inovonics Wireless Corporation e-mail: [email protected] • www.inovonicswireless.com i This product bears the CE mark and certification. Please email [email protected] to request the "Declaration of Conformity." Transmit Button Transmit LED Transmit LED Figure 5: Belt clip, Pendant accessory and wristband Figure 6: ES1223S with neck cord WARRANTY & DISCLAIMER Inovonics Wireless Corporation ("Inovonics") warrants its products ("Product" or "Products") to conform to its own specifications and to be free of defects in materials and workmanship under normal use for a period of twenty-four (24) months from the date of manufacture. Within the warranty period, Inovonics will repair or replace, at its option, all or any part of the warranted Product. Inovonics will not be responsible for dismantling and/or reinstallation charges. To exercise the warranty, the User ("User", "Installer" or "Consumer") must work directly through their authorised distributor who will be given a Return Material Authorisation ("RMA") number by Inovonics. Details of shipment will be arranged directly through the authorised distributor. This warranty is void in cases of improper installation, misuse, failure to follow installation and operating instructions, alteration, accident or tampering, and repair by anyone other than Inovonics. This warranty is exclusive and expressly in lieu of all other warranties, obligations or liabilities, whether written, oral, express, or implied. There is no warranty by Inovonics that Inovonics product will be merchantable or fit for any particular purpose, nor is there any other warranty, expressed or implied, except as such is expressly set forth herein. In no event shall Inovonics be liable for an incidental, consequential, indirect, special or exemplary damages, including but not limited to loss of profit, revenue or contract, loss of use, cost of down time, or interruption of business, nor any claim made by distributor's customers, or any other pe…

Text truncated - open the document above for the full version.

Attestation Statements

FCC ID: HCQ3B6ETRTA2 ES1223 1. Attestation Statements: There are no attestation statements relevant to this device.

Cover Letter(s)

April 6, 2004 Federal Communications Commission Authorization and Standards Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Request for Confidentiality for FCC ID# HCQ3B6ETRTA2 Gentlemen: The following reports are marked confidential, and should be maintained in the non- public file. This confidentiality is necessary to protect proprietary information contained within these sections of the application for Certification. 1) Operational Description 2) Schematics 3) Block Diagram Thanks for your help. Sincerely, Donald J. Hume President

Cover Letter(s)

May 25, 2004 Applicant: Inovonics Wireless Corp. FCC ID: HCQ3B6ETRTA2 Correspondence Reference Number: 26853 731 Confirmation Number: EA983542 Re: Action Item regarding Grant approval 1) Please submit RF output power measurement at low, middle and high frequency bands. Pursuant to FCC Public Notice DA 00-705, the following measurements were made using an Agilent 8594E spectrum analyzer having the following settings: Span: 1250 kHz (approximately 5 times the 20 dB bandwidth) RBW: 300 kHz (RBW > the 20 dB bandwidth) VBW: 300 kHz (VBW  RBW) Sweep: auto Detector: peak Trace: max hold The antenna is removed and a 3” semi-rigid coaxial cable having negligible insertion loss connects the DUT to the spectrum analyzer. Plot 1: RF output at the low channel Plot 2: RF output at the middle channel Plot 3: RF output at the high channel

Cover Letter(s)

May 27, 2004 Applicant: Inovonics Wireless Corp. FCC ID: HCQ3B6ETRTA2 Correspondence Reference Number: 26862 731 Confirmation Number: EA983542 Re: Action Item regarding Grant approval 1) Please submit the average time of occupancy measurement per Section 15.247(a)(1)(i) and FCC Public Notice DA 00-705. Section 15.247(a)(1)(i) states, “...if the 20 dB bandwidth of the hopping channel is 250 kHz or greater, the system shall use at least 25 hopping frequencies and the average time of occupancy on any frequency shall not be greater than 0.4 seconds within a 10 second period.” To effectively obtain this measurement, FCC Public Notice DA 00-705 requires the following spectrum analyzer settings: Span: 0 RBW: 1 MHz VBW: 1 MHz (VBW  RBW) Sweep: 60 ms (as necessary to capture the entire dwell time per hopping channel) Detector: peak Trace: max hold Plot 1 below clearly shows the dwell time is less than the 0.4 seconds required by 15.247(a)(1)(i). Plot 1: Channel Occupancy 2) Form 731 shows 0.05 watts and your reply on May 25, 2004 shows 17.82 dBm or 0.06 watts. Please clarify. The device in question is designed to have a typical output power of 17 dBm. A unit-to- unit variation of +1 dB, -2 dB is anticipated.

External Photos

FCC ID: HCQ3B6ETRTA2 ES1223 4. External Photos: Topside view. Bottom side view

ID Label/Location Info

CONFIDENTIAL DOCUMENT ES1223D FCC - CE Label 03960A CONFIDENTIAL DOCUMENTATION The information contained in this document is confidential to and the sole property of Inovonics Corporation. Receipt of this information requires the existence and full acceptance of the terms and conditions of a Non Disclosure Agreement signed by the Inovonics Corporation and the Recipient. This documentation is not to be reproduced or redistributed except as provided in the Non Disclosure Agreement. MATERIAL:.002" THICK BLACK MYLAR WITH .001" GLOSSY LAMINATION (FOR PROTEC- TION FROM INK SMEARING) AND PERMANENT ADHESIVE APPLIED TO THE BACKSIDE ARTWORK:SUPPLIED BY INOVONICS TEXT: WHITE LABEL SIZE: See Detail A PACKAGING AND LABEL ORIENTATION:LABELS TO BE SUPPLIED AS INDIVIDUAL PIECES ON SPLIT LINER (SEE DETAIL A.) Rev. Level DescriptionDate AInitial Release10/10/2003 © 2003 Inovonics Wireless Corporation

Internal Photos

FCC ID: HCQ3B6ETRTA2 ES1223 6. Internal photos: PCB Topside PCB bottomside Integrated Antenna

Parts List/Tune Up Info

FCC ID: HCQ3B6ETRTA2 ES1223 8. Parts List/Tune Up Info: This exhibit does not apply to this device.

RF Exposure Info

FCC ID: HCQ3B6ETRTA2 ES1223 9. RF Exposure Information: Calculation for compliance with SAR requirements (47CFR2.1093) is done using a worst-case transmitter power of 50 mW time-averaged by the duty cycle of the transmitter, and the assumption that all RF energy could be absorbed in 1 gram of tissue. The peak exposure limit is 1.6 mW/g (equivalent to 1.6 W/kg per 47CFR2.1093) in any 1 gram of tissue for General Population/Uncontrolled applications. This device has an extremely low duty cycle that dramatically reduces the average power level that could pose an exposure hazard. The user only activates the transmitter during a duress or panic situation, which is a very rare event. The transmitter is also configured to transmit a supervisory message once every 3 minutes. For a worst-case calculation, we assume 1 panic transmission and a supervision transmission in a 3-minute interval. A panic message consists of 21 redundant packets and a supervisory message consists of 3 redundant packets for a total of 24 packets in the interval. Each packet has duration of 20 ms. The time-averaged RF transmit power is then, mW ms packet mspackets W133.0 1060 min120 min3 24 05.0 3 = ¥ ¥¥¥ If all of the transmitted power were absorbed in a 1-gram sample of tissue, the power density is 0.133 mW/gram and is well below the 1.6 mW/gram limit.

Test Report

EMC EMISSIONS - TEST REPORT (In-Part) Test Report No. BC300339-1a Issue Date: Thu 11/Sep/2003 Model / Serial No. ES1223 / SN: 1 Product Type Small Pendant Client Inovonics Wireless Manufacturer Inovonics Wireless License holder Inovonics Wireless 315 CTC Boulevard Address Louisville, CO 80027 Test Criteria Applied FCC Part 15.247 Test Result PASS Test Project Number References BC300339-1a Total Pages Including Appendices: 23 FCC CFR47 Part 15: Radio Frequency Devices Reviewed By : Todd Seeley Approved By : Robert Cresswell INTERNATIONAL APPROVALS LABORATORIES (IAL) reports apply only to the specific samples tested under stated test conditions. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. IAL have no liability for any deductions, inferences or generalizations drawn by the client or others from IAL issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval of IAL. This report shall not be used by the client to claim product endorsement by NVLAP (No. 200624- 0) or any agency of the US government. International Approval Laboratories and its professional staff hold government and professional organization certifications and are members of IEEE, NVLAP, and VCCI. Project File: BC300339 -1a_ES1223 Page 2 of 23 International Approvals Laboratories, LLC 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999 Fax: 303 449 6160 Rev.No 1 D I R E C T O R Y Documentation Page(s) Test report 1 - 23 Directory 2 Test Regulations 3 General Remarks 3 Test-setup Photographs 4 - 7 Appendix A Test Data Sheets and Test Equipment Used 8 - 17 Appendix B Test Plan/Constructional Data Form 18 - 18 Appendix C Measurement Protocol/Test Procedures 19 - 23 STATEMENT OF MEASUREMENT UNCERTAINTY The data and results referenced in this document are true and accurate. The measurement uncertainty for Conducted Emissions in the frequency range of 150kHz – 30MHz is calculated to be ±2.30dB and for Radiated Emissions is calculated to be ±3.60dB in the frequency range of 30MHz – 200MHz and ±3.38dB in the frequency range of 200MHz – 1000MHz. EUT Received Date: 26-August-2003 Testing Start Date: 26-August-2003 Testing End Date: 11-Sep-2003 Project File: BC300339 -1a_ES1223 Page 3 of 23 International Approvals Laboratories, LLC 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999 Fax: 303 449 6160 Rev.No 1 The tests were performed according to following regulations : 1. FCC CFR47 Part 15.209 2. FCC CFR47 Part 15.205 3. FCC CFR47 Part 15.247 (b) & (c) Emission Test Results: Conducted Emissions, Powerline - 15.207 (not applicable) Test Result Minimum limit margin dB at MHz Maximum limit exceeding dB at MHz Remarks: Radiated Emissions (Electric Field) - 15.209 - PASS Test Result Minimum limit margin 16.70 dB at 811.66 MHz Maximum limit exceeding dB at MHz Remarks: Radiated Emissions (Electric Field) - 15.247(b) - PASS Test Result Minimum limit margin 26.58 dB at 902.41 MHz Maximum limit exceeding dB at MHz Remarks: Radiated Emissions (Electric Field) - 15.247(c) - PASS Test Result Minimum limit margin 8.18 dB a at 3609.51 MHz Maximum limit exceeding dB at MHz Remarks: GENERAL REMARKS: None Modifications required to pass: None Test Specification Deviations: Additions to or Exclusions from: None Project File: BC300339 -1a_ES1223 Page 4 of 23 International Approvals Laboratories, LLC 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999 Fax: 303 449 6160 Rev.No 1 Test-setup photo(s): Unintentional Radiated Emissions Project File: BC300339 -1a_ES1223 Page 5 of 23 International Approvals Laboratories, LLC 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999 Fax: 303 449 6160 Rev.No 1 Test-setup photo(s): Unintentional Radiated Emissions Project File: BC300339 -1a_ES1223 Page 6 of 23 International Approvals Laboratories, LLC 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999 Fax: 303 449 6160 Rev.No 1 Test-setup photo(s): Intentional Radiated Emissions Project File: BC300339 -1a_ES1223 Page 7 of 23 International Approvals Laboratories, LLC 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999 Fax: 303 449 6160 Rev.No 1 Test-setup photo(s): Intentional Radiated Emissions Project File: BC300339 -1a_ES1223 Page 8 of 23 International Approvals Laboratories, LLC 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999 Fax: 303 449 6160 Rev.No 1 Appendix A Test Data Sheets and Test Equipment Used Unintentional Radiated Emissions Test Report #: BC300339 Run 10 Test Area: Pinewood Site 1 (3m) Temperature: 21.6 °C Test Method: FCC Part 15.209 Test Date: 11-Sep-2003 Relative Humidity: 54 % EUT Model #: ES1223, ES1233, ES1260, ES1247 EUT Power: 3 VDC Air Pressure: 81 kPa EUT Serial #: 1, 1, 1, 1 Page: 1 of 5 Manufacturer: Inovonics Level Key EUT Description: Security Transmitters Pk – Peak Nb – Narrow Band Notes: All four units are being tested simultaneously Qp – QuasiPeak Bb – Broad Band All tranmitters are hopping, normal operation Av - Average FREQ LEVEL CABLE / ANT / PREAMP FINAL POL / HGT / AZ DELTA1 (dB) DELTA2 (dB) (MHz) (dBuV) (dB) (dB\m) (dB) (dBuV/m) (m) (DEG) FCC B (< 1GHz) FCC B (> 1GHz) Log Antenna, Vertical, 200-1,000 MHz 0 degrees No emissions detected 90 degrees No emissions detected 180 degrees No emissions detected 270 degrees No emissions detected The following reading is a noise floor measurement 760.36 21.6 Qp 2.4 / 21.2 / 28.2 17.0 V / 1.0 / 0.0 -29.0 N/A 0 degrees No emissions detected 90 degrees 811.66 32.3 Qp 2.4 / 21.7 / 28.3 28.1 H / 1.0 / 0.0 -17.9 N/A 180 degrees No emissions detected 270 degrees No emissions detected Maximized emissions, Horizontal from 200-1,000 MHz 811.66 33.5 Qp 2.…

Text truncated - open the document above for the full version.

Test Report

FCC ID: HCQ3B6ETRTA2 ES1223 11. Test Report The test report containing intentional/unintentional emissions data is attached as “BC300339-1a_ES1223_.pdf”. International Approvals Laboratories generated this report. Additional data demonstrating compliance with 47CFR15.247 follows. For the following plots, the antenna was replaced by a coaxial connection to a an HP8594E spectrum analyzer. Plot 1 is a spectrum plot showing a minimum channel separation of 800 kHz. Compliance with section 15.247(a)(1) is demonstrated by capturing several transmissions over a small portion of the 902-928 MHz ISM band. Plot 1: Demonstration of channel spacing requirement. FCC ID: HCQ3B6ETRTA2 ES1223 Plot 2 demonstrates compliance with 15.247(a)(1)(i) — Number of hopping channels. This is a stored display of many sequential transmissions to show the overall band occupied by the transmitter. Plot 2: Demonstration of 25 hopping channels. Plots shows the 20 dB bandwidth of a single channel to demonstrate compliance with 15.247(a)(1)(i). The 20 dB occupied bandwidth is 258 kHz. Plot 3: Demonstration of occupied bandwidth.

Test Setup Photos

FCC ID: HCQ3B6ETRTA2 ES1223 12. Test Setup Photos The test setup photos are contained within the test report of the previous section.

Contact Information

Applicant

Jess Cobb(Manager of Program Mgmt)
[email protected]13032097290Fax: 13032097243

Technical Contact

Inovonics Wireless CorporationSteve Dunbar
[email protected]303-209-7174

315 CTC Blvd. · Louisville, Colorado · United States

Non-Technical Contact

Inovonics Wireless Corp.Amy Arguelles
[email protected]303-209-7167

Test Firm

International Approval Laboratories, LLCTodd Seeley
[email protected]303-402-5272Fax: 303-449-6160

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902.4 MHz - 927.6 MHz60.00 mW
Confidentiality
Long Term

Other Applications from Inovonics Wireless Corporation

Inovonics Wired Touchscreen Keypad - FCC ID HCQ-IDTOUCH1 - Inovonics Wireless Corporation
HCQ-IDTOUCH1

Inovonics Wired Touchscreen Keypad

May 13, 2026

Equipment Class

DTS - Digital Transmission System
Flush Mount Locator - FCC ID HCQBWA02 - Inovonics Wireless Corporation
HCQBWA02

Flush Mount Locator

Aug 28, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
TBA Module - FCC ID HCQTBA - Inovonics Wireless Corporation
HCQTBA

TBA Module

Sep 21, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Fall Detect Transmitter - FCC ID HCQPFA01 - Inovonics Wireless Corporation
HCQPFA01

Fall Detect Transmitter

Jul 14, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Bluetooth to EchoStream Bridge - FCC ID HCQ3B6BRGSA - Inovonics Wireless Corporation
HCQ3B6BRGSA

Bluetooth to EchoStream Bridge

Sep 22, 2020

Equipment Class

DTS - Digital Transmission System