4/11/14 05583F © Inovonics, 2013 - www.inovonics.com EN1223D/EN1223D-15 EchoStream ® Double- Button Water-Resistant Pendant Transmitter Installation and Operation Manual 1 Overview The Inovonics double-button water-resistant pendant transmitter is our smallest, lightest, and most versatile pendant. Note: For UL installations, refer to the EN4216MR Installation and Operation Manual, the EN4232MR Installation and Operation Manual, or the EN7285 Installation Instructions. 1.1 Inovonics Wireless Contact Information If you have any problems with this procedure, contact Inovonics Wireless technical services: • E-mail: [email protected] • Phone: 1.800.782.2709, option 2 1.2 Transmitter External Components Figure 1 Transmitter external components 1.3 Transmitter Internal Components Figure 2 Transmitter internal components 1.4 What’s In The Carton • One EchoStream double-button water-resistant pendant transmitter • One breakaway neck cord • One beltclip attachment • Three housing screws • One frequency band selection jumper • One CR2450 coin cell battery 2 Installation and Startup 2.1 Installation Notes • These products are designed to be maintained by professional security technicians • Products are intended for indoor use • All products should be manually tested weekly (see “Test the Transmitter” on page 2) 2.2 Initial Setup Battery Installation 1.Remove the rear housing cover to expose the side of the board that holds the battery. Caution: Carefully separate the rear housing cover, ensuring the reset button plunger assembly does not fall out of the housing (Figure 2). 2.Slide the battery under the battery holder, ensuring that it is fully inserted and that the positive terminal (+) faces up (Figure 2). Select the Frequency Band EchoStream products are able to use a range of radio frequencies, and must be configured for your geographic area. This product ships with a default frequency range of 902-928 MHz for use in North America. If you are using the product in North America, skip to step 6; if you are using the product in Australia or New Zealand, you will need to configure the transmitter. To configure the transmitter: 3.Turn the board over to access the side with the frequency band selection pins (Figure 2). 4.Place the frequency band selection jumper on the appropriate frequency band selection pins. • Place the jumper on the left two pins, marked AU, to set the frequency range to 915-928 MHz for Australia. • Place the jumper on the right two pins, marked NZ, to set the frequency range to 921-928 MHz for New Zealand. 5.Seat the board in the housing with the battery side facing the rear housing cover. 6.Replace the front housing cover. 7.Insert the three housing screws, tightening them to 1.25 inch-pounds torque. Note: If you do not have a torque driver, tighten to a snug fit, being careful not to overtighten. Note: Tighten the housing screws evenly to help ensure a good seal and maintain water-resistance. Caution: Over-tightening the housing screws can result in microcracks in the plastic, gaps in the gasket material, and/or stripping of the bushing. Any of these conditions can compromise the water-resistance of the device. Register the Transmitter The transmitter must be registered and supervised. When supervised, the transmitter will send check-in message to the receiver or gateway as follows: • EN1223D: every three minutes. • EN1223D-15: every 15 minutes. Each transmitter has a unique factory-programmed identification number. Refer to the receiver or gateway's installation instructions for details on registering and setting up supervision. 8.When prompted by the receiver or gateway to reset transmitter, press the reset button (Figure 1). Caution: The transmitter should be tested after registration to ensure operation. See “Test the Transmitter” on page 2. 3 Operate the Transmitter To send an alarm, press both activation buttons simultaneously for at least one second. Alarm signals are transmitted multiple times and are indicated by the blinking transmission LED. When the buttons are released, the transmitter sends an alarm restoral signal as indicated by another short series of blinking transmission LED lights. 3.1 Wear the Transmitter The pendant transmitter can be worn in three ways: • Around the neck with neck chain attachment (included) • On a belt with the beltclip attachment (included) • On the arm with optional wristband accessory (ACC623S or ACC623L, sold separately) Caution: The neck chain included with the pendant transmitter is designed with a breakaway feature for user safety. Substitution of a stronger cord or chain may result in injury to the wearer. Note: The optional wristband accessory is not part of the UL listing. 3.2 Water Exposure All EchoStream water-resistant pendants meet IP54 certification standards for dust and water ingress protection, ensuring that: • Ingress of dust particles does not interfere with the satisfactory operation of the device • There is no harmful effect to the device caused by: - Vertically dripping water (when device is tilted up to 15° from normal position) - Spraying water (falling at angles up to 60° from vertical) - Splashing water (from any direction) ATransmit LEDBActivation buttonsCReset button AFrequency band selection pins BBatteryCReset button plunger assembly C B A A B C 4/11/14 05583F © Inovonics, 2013 - www.inovonics.com 2 End User Recommendations IP54 certification is classified as water-resistant, but not waterproof. The products are not designed for submersion in water. As such, we offer the following recommendations for end users: Note: Dust and water ingress protection is not part of the UL listing. 3.3 Battery Replacement Replacement batteries can be purchased from Inovonics using the following part numbers • BAT609 for a single battery • BAT609-25 for a 25-count bulk pack To replace the batteries: 1.Remove the three housing screws on the back of the transmitter. 2.Remove the rear cover to expose the side of the board wh…
Text truncated - open the document above for the full version.
Authority to Act as Agent Date: March 9, 2011 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: ______Keal Vigil ______ is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date: December 31, 2011 Keal Vigil Production Control Specialist II
Request for Confidentiality Date: March 9, 2011 Subject: Confidentiality Request for: FCC ID: HCQ3B6OT9RTA; IC ID 2309A-ETRTA2 Pursuan t to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Permanent* 1 Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term Permanent* User’s Manual *Note: ______(Insert Explanation as Necessary) ______ Inovonics Wireless Corporation has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 2 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. 1 - The asterisked items (*) require further justification before permanent confidentiality will be allowed. These also currently require review by the FCC under their Permit-But-Ask policy before the grant is issued and can delay completion of an application. Further justification should be added to the note above. One such example for a potted device would be: “The EUT is FULLY potted using a non-removable epoxy based material. Removal of potting material causes irreparable damage to internal circuitry. See photographs exhibits that outline the device before and after potting.” 2 - Please refer to http://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details. NOTE for Industry Canada Applications: The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality, either type of marked exhibit above will simply be marked Confidential when submitted to IC. Sincerely, Keal Vigil Production Control Specialist II
American Certification Body, Inc ACB, Inc. 6731 Whittier Avenue, Suite C110 • McLean, Virginia 22101 USA Ph: (703) 847-4700 • Fax: (703) 847-6888 www.ACBcert.com Date: March 4, 2014 Federal Communications Commission EQUIPMENT APPROVAL SERVICES P.O. Box 358315 Pittsburgh, PA 15251-5315 ATTN: Authorization & Evaluation Division Per: 47 CFR 0.457 and 0.459 To Whom It May Concern, ACB is submitting this KBD on behalf of our customer, Inovonics. We are requesting that the following application be placed into Audit Mode in order to Supercede the original RF Exposure Documentation. TC903694 FCC ID: HCQ3B6OT9RTA Inovonics was reminded that the worst-case power density value should not have been used in the formula, rather the actual power density of each product is required. Therefore, the formula was corrected, as well as some additional minor assumptions corrections made. Additionally, the former document mistakenly contained the statement that each product is not carried or worn by the end-user. As these devices are typically worn either around the neck, or on the wrist, this statement was removed in the corrected version. Please let us know if there is any additional information needed in order to process our request. Thank you for your time and we look forward to hearing from you shortly. Sincerely, Karen M Springer Karen Springer Customer Support American Certification Body Office: 703.635.0757 Email: [email protected]
FCC ID: HCQ3B6OT9RTA EN1223 IC ID: 2309A-ETRTA2 External Photos: Front of Product Back of product showing FCC ID Number Page 1
LBL-FCC-EN1223D 05585B MATERIAL:.002" THICK WHITE MYLAR WITH BLACK REVERSE COLOR WITH .001" GLOSSY LAMINATION (FOR PROTECTION FROM INK SMEARING) AND PERMANENT ADHESIVE APPLIED TO THE BACKSIDE. RoHS COMPLIANT MATERIALS REQUIRED. ARTWORK:SUPPLIED BY INOVONICS TEXT: WHITE LABEL SIZE: See Detail A PACKAGING AND LABEL ORIENTATION:LABELS TO BE SUPPLIED ON A ROLL, EACH SEPA- RATED BY PERFORATION, WITH OVERSIZE LINER FOR EASY REMOVAL. Rev. Level DescriptionDate AInitial Release04/24/2009 BEdited IC number06/30/2010 Label Location
FCC ID: HCQ3B6OT9RTA EN1223D IC ID: 2309A-ETRTA2 Page 1 Internal Photos: PCB BACK FCC ID: HCQ3B6OT9RTA EN1223D IC ID: 2309A-ETRTA2 Page 2 Internal Photos (cont’d): PCB FRONT Trace Antenna
FCC ID: HCQ3B6OT9RTA EN1223 IC ID: 2309A-ETRTA2 RF Exposure Information: SAR Test Exclusion Threshold – The transmitter has a maximum duty cycle of 40% which is controlled by software; it cannot transmit continuously or at a faster rate. The calculation for the SAR exclusion threshold is: [.40 (Duty Cycle)] · [(max. power of channe )/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 The measured power for the transmitter is 19.3 mW. The minimum distance from any radiating element and the user is 5mm. Under these conditions, the threshold calculation is: 49.1928. 5 3.19 40.0 mm mW This is below the threshold for requiring SAR testing.
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. EMC Report for Inovonics on the EN1223D Page 1 of 29 TEST REPORT Report Number: 100356542DEN-002C Project Number: G100356542 Report Issue Date: 03/25/2011 Product Designation: EN1223D Standards: FCC title 47 CFR part 15 subpart C RSS-210:2010 Issue 8 AS/NZS 4268:2008 Tested by: Client: Intertek Testing Services NA, Inc. 1795 Dogwood St. Suite 200 Louisville, CO 80027 Inovonics Wireless Corp. 315 CTC Blvd. Louisville, CO 80027 Report prepared by Report reviewed by Randall Thompson Senior EMC Project Engineer Michael Spataro Engineering Team Leader Intertek Report Number: 100356542DEN-002C Issued: 03/25/2011 EMC Report for Inovonics on the EN1223D Page 2 of 29 TABLE OF CONTENTS 1 Introduction and Conclusion .............................................................................................................. 3 2 Test Summary ...................................................................................................................................... 3 3 Description of Equipment Under Test................................................................................................ 4 4 System setup including cable interconnection details, support equipment and simplified block diagram ........................................................................................................................................................ 5 5 Radiated Emissions – Intentional Radiators: Output Power - Fundamental & Harmonics of the Fundamental for 15.247 .............................................................................................................................. 7 6 Radiated Emissions Unintentional & Spurious............................................................................... 14 7 Measurement Uncertainty ................................................................................................................. 28 8 Revision History................................................................................................................................. 29 Intertek Report Number: 100356542DEN-002C Issued: 03/25/2011 EMC Report for Inovonics on the EN1223D Page 3 of 29 1 Introduction and Conclusion The tests indicated in section 2.0 were performed on the product constructed as described in section 3.0. The remaining test sections are the verbatim text from the actual data sheets used during the investigation. These test sections include the test name, the specified test Method, a list of the actual Test Equipment Used, documentation Photos, Results and raw Data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested Passed the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. 2 Test Summary Section Test full name Test date Result 5 Radiated Emissions – Output power of the Fundamental & Harmonics of the Fundamental - FCC 247(b)(2) (d)/15.205 Covers RSS-210 A8.4(1) 3/16/2009 Pass 6 Radiated Emissions – Unintentional & Spurious - FCC 15.247(d) / FCC 15.209/109 Covers RSS-210 A8.5 3/30/2009 Pass 20dB Bandwidth – FCC 15.247 (a)(1)(i) [Covers RSS-210, A8.1(c)] ----- N/A Number of Hopping Channels – FCC 15.247(a)(1)(i) [Covers RSS-210, A8.1(c)] ----- N/A Hopping Channel Carrier Separation – FCC 15.247(a)(1) [Covers RSS-210, A8.1(b)] ----- N/A Band Edge Measurements – FCC 15.247(d) / 15.209 [Covers RSS-210, A8.5] ----- N/A Duty Cycle & Duty Cycle Correction Factor ----- N/A AC Conducted Emissions – FCC 15.207 (not applicable – product battery-powered) ----- N/A Notes: 1) Only the fundamental, harmonics of the fundamental and Spurious emissions are covered in this test report as requested by the customer. 2) Only the high channel of the transmitter at 927.58 MHz falls within the frequency band specified in AS/NZS 4268:2008 3) FCC CFR47 Part 15.31: Measurement Standards: In any case where the device is powered off a battery, a fresh battery was used during test. In cases where the device is powered off an AC supply, voltage was varied per Part 15.31 to find worst case emissions. Intertek Report Number: 100356542DEN-002C Issued: 03/25/2011 EMC Report for Inovonics on the EN1223D Page 4 of 29 3 Description of Equipment Under Test Equipment Under Test Description Manufacturer Model Number Serial Number 902-928MHz wireless transmitter. Inovonics EN1223D 04154729 Receive Date: 3/16/2009 Received Condition: Good Type: Production Description of Equipment Under Test (provided by client) The Inovonics wireless, water-resistant pendant transmitters are our smallest, lightest and most versatile pendant. They come in two basic configurations: a single-button press-and-hold activation, ideal for assisted living installations, or a double-button designed to meet the specific protection needs of patrolling guards, bank employees and retail store employees. The water-resistant pendant transmitter is available in two configurations for 868-870 Mhz Europe, or for 902-928 Mhz North A…
Text truncated - open the document above for the full version.
1 Test Report: Additional Information Model EN1223D Revision Description Author Issue Date A Initial Release HB 31-Mar-11 General Remarks: In addition to the intentional and unintentional emissions lab test reports submitted with this application, this test report includes additional test data demonstrating compliance with CFR47, 15.247 and RSS-210, A8.1. For the measurements in this report, the antenna was replaced by a coaxial connection to a MXA signal analyzer, model N9020A. Calculations for Conducted Output Power and Duty Cycle Correction Factor are also included. 2 Report Summary Result Page Section 1 Minimum Channel Separation Pass 3 Section 2 20 dB Occupied BW Pass 4 Section 3 Number of Hopping Channels Pass 5 Section 4 Dwell Time Pass 6 Section 5 Test Instrument Declarations Pass 7 Section 6 Conducted Output Power & Duty Cycle N/A 8 Correction Factor General Declarations Continuous receiver operation N/A Continuous transmitter operation No Band of operation (USA and Canada) 902-928 MHz Band of operation (Australia mode) 915-928 MHz Band of operation (New Zealand mode) 921-928 MHz Lower transmit frequency (Australia) 915.6 MHz Lower transmit frequency (New Zealand) 921.6 MHz Upper transmit frequency (AUS and NZ) 927.6 MHz Minimum Transmit Channel Spacing 400KHz Receiver frequencies N/A Frequency hopping transmitter Yes Integral antenna equipment Yes Normal battery input voltage 3V DC Maximum TX on-time (single message) 22ms 3 Minimum Channel Separation Test Method 15.247 Section 1 UUT Model No. EN1223D Test Date 31-Mar-11 UUT Serial Number(s) Normal Temp 25.93 C UUT Description Security transmitter Normal Humidity 31.63% UUT MFGR: Inovonics Wireless Tested By: HB Test Result Pass 4 20 dB Occupied Bandwidth Test Method 15.247 Section 2 UUT Model No. EN1223D Test Date 31-Mar-11 UUT Serial Number(s) Normal Temp 25.93 C UUT Description Security transmitter Normal Humidity 31.63% UUT MFGR: Inovonics Wireless Tested By: HB Test Result Pass Plot shows the 20 dB occupied bandwidth of a single channel to demonstrate compliance with 15.247(a)(1)(i) and RSS-210, A8.1(c). 5 Number of Transmitter Channels Test Method 15.247 Section 3 UUT Model No. EN1223D Test Date 31-Mar-11 UUT Serial Number(s) Normal Temp 25.93 C UUT Description Security transmitter Normal Humidity 31.63% UUT MFGR: Inovonics Wireless Tested By: HB Test Result Pass Plot demonstrates compliance with 15.247(a)(1)(i), and RSS-210, A8.1(c). This is a stored display of many sequential transmissions to show the overall band occupied by the transmitter. 6 Dwell Time Test Method 15.247 Section 4 UUT Model No. EN1223D Test Date 31-Mar-11 UUT Serial Number(s) Normal Temp 25.93 C UUT Description Security transmitter Normal Humidity 31.63% UUT MFGR: Inovonics Wireless Tested By: HB Test Result Pass Plot demonstrates compliance with 15.247(a)(1)(i), and RSS-210, A8.1(c), which states “the average time of occupancy on any channel shall not be greater than 0.4 seconds within a 10 second period.” Measured Dwell Time in ms Maximum limit in seconds Complies 21.04 0.4 Yes 7 Test Instrument Declarations Test Method 15.247 Section 1 through 4 UUT Model No. EN1223D UUT Serial Number(s) UUT Description Security transmitter UUT MFGR: Inovonics Wireless Testing Instrument Description Signal Analyzer Make Agilent Calibration date 27-Sep-10 Model # N9020A Calibration due date 27-Sep-11 Serial # MY46471353 8 Alternative to Conducted Output Power Measurements: Required conducted power output measurements at low, medium, and high channels (per 15.247(b) and (c)) could not be performed directly since the transmit antenna is integrated onto the printed circuit board. However, compliance with these requirements has been achieved by way of performing and passing the radiated tests described in the ALTERNATIVE TEST PROCEDURES in Public Notice DA 00-705, March 30, 2000. Specifically, all radiated emissions shown in the test report are less than 119.2 dBuV/m at 3 meters. This is the field strength limit corresponding to the maximum fundamental power output of 0.25 watts from an isotropic antenna per 15.247 (b) (2) for systems employing between 25 and 49 hopping channels. The calculation as detailed in the above Public Notice is as follows: E = Square Root of (30PG) all divided by d E = 912,871 uV/m = 119.21 dB uV/m where E is the maximum allowable fundamental field strength in uV/m P is the maximum allowable fundamental radiated power = 0.25 watts G is the antenna gain = 1 (Assume 1 for the worst case (lowest allowable) final field strength.) d is the measured distance = 3 meters Duty Cycle Correction Factor (DCCF) DCCF formula obtained from Public Notice DA 00-705 dBDCCF ms ms DCCF ms timeDwell DCCF 6.13 100 8.20 log20 100 log20
Project File: 3175935 Page 6 of 42 Intertek Testing Services NA, Inc. 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999Fax: 303 449 6160 Test Setup Photos Pendant Transmitter Project File: 3175935 Page 7 of 42 Intertek Testing Services NA, Inc. 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999Fax: 303 449 6160 Test-setup photo(s): Radiated Intentional Emissions: Worst-Case Axis 1 [EUT Flat on Table] Project File: 3175935 Page 8 of 42 Intertek Testing Services NA, Inc. 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999Fax: 303 449 6160 Test-setup photo(s): Radiated Intentional Emissions: Worst-Case Axis 1 Project File: 3175935 Page 9 of 42 Intertek Testing Services NA, Inc. 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999Fax: 303 449 6160 Test-setup photo(s): Radiated Intentional Emissions: Axis 2 [EUT Vertical] Project File: 3175935 Page 10 of 42 Intertek Testing Services NA, Inc. 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999Fax: 303 449 6160 Test-setup photo(s): Radiated Intentional Emissions: Axis 3 [EUT Vertical & Rotated 90 degrees CW]
315 CTC Blvd. · Louisville · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.4 MHz - 926.4 MHz | 19.30 mW |

Inovonics Wired Touchscreen Keypad
Equipment Class
DTS - Digital Transmission System
Flush Mount Locator
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
TBA Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Fall Detect Transmitter
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Bluetooth to EchoStream Bridge
Equipment Class
DTS - Digital Transmission System