FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Inovonics Wireless Corporation/
  3. HCQ3B6SSRLA

HCQ3B6SSRLAIntelligent Repeater

Inovonics Wireless Corporation
Intelligent Repeater - FCC ID HCQ3B6SSRLA - Inovonics Wireless Corporation
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Apr 27, 2005
Application Purpose
Original Equipment
Date of Application
Jan 23, 2005
Equipment Note
Intelligent Repeater
Frequency Range
906.00000000 - 920.00000000
Company
Inovonics Wireless Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗
↗

RF Exposure Info

↗
↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

L I T- FA 5 5 7 0 - I N ST A L L 102775.fm 11/01/2001 L I T- FA 5 5 7 0 - I N ST A L L 102775.fm 11/01/2001 WIRELESS SUBMETERING                        AC PO W ER BACKUP POW ER DECODING NOT ACTIVE REPEATIN G By INOVONICS AC PO W ER BACKUP POWER WIRELESS SUBMETERING  DECODING NOT ACTIVE REPEATING    !"! # $ %&  """"!"   '   #  ($%&  """"!"  ") ""  # %"*(!"%(   ") ""  # %( ($+)"""!""  '(!"")   ! ,  ! #$"   "  , )  ",, #                                           Product Description The FA5570 is a sophisticated repeater that receives, decodes, and re-transmits signals from TapWatch submetering transmit- ters. It acts as a "range extender" for any decodable TapWatch transmission. The FA5570 is intended for quick and easy indoor installation by professional technicians. (Kits are available for outdoor installation.) © 2001 Inovonics Wireless Corporation Specifications Housing dimensions: 6.38" x 3.60" x 1.10" We i g h t :6 . 9 o z . Power requirement: 14 VA (Optional) Backup battery: 12VD Low voltage threshold: 10.5-11.5VDC Receiver type: frequency-hopping spread spectrum Operating frequency: 902-928 MHz Operating Environment: -20° to 145°F (-29 to 63°C), up to 95% relative humidity (non-condensing) L I T- FA 5 5 7 0 - I N ST A L L 202775.fm 11/01/2001 L I T- FA 5 5 7 0 - I N ST A L L 202775.fm 11/01/2001 Repeater Registration into the TapWatch ® 2 Software and DCC FA5570 repeaters should be registered to report status to the TapWatch system. The system will then be able to monitor the repeater. Detailed instructions are in the TapWatch2 Users Manual, part number 03253. Following is a brief description of the registration procedure. Registering a Repeater in TapWatch2: 1.From the Edit Repeater screen, click on "Add" button. "Add a Repeater" screen opens. 2.Enter the description of repeater location. Enter the description of the repeater location. 3.Register repeater. It is recommended that repeaters are registered to provide diagnostic information. 4.New repeater will appear under Repeaters tab. “OK” saves and exits screen. “Cancel” exits screen without saving. Operation Power supply : A 14VAC transformer is provided with the FA5570. Backup battery : An optional 1.2AH 12VDC battery (not included) can be mounted outside the FA5570 hous- ing. This is typically not used in submetering applications. Low voltage detection : The repeater will report low voltage if the supply voltage (either primary or backup) drops into a preset range. • AC power failure will not be reported directly—the TapWatch system will detect inactivity if repeater power is off for the duration of the supervision period. Supervision : Once every 5 minutes, the repeater sends a check-in transmission to the receiver. The repeater will be declared inactive if no check-ins are received before the expiration of the supervision period. Test mode : Pressing the Test button will cause the repeater to transmit its current status until the button is released. Note: Repeaters do not show a "Test" state. Status will be displayed as "OK", "Low Battery" or "Inactive". L I T- FA 5 5 7 0 - I N ST A L L 302775.fm 11/01/2001 L I T- FA 5 5 7 0 - I N ST A L L 302775.fm 11/01/2001 Installation Mounting repeaters : •Unless directed by the system designer, do not mount repeaters on metal sur- faces or inside metal enclosures, or where sheet metal ductwork, wire mesh screens, etc., might block transmissions. •Outdoor installations require a weatherproof enclosure. (Available separately.) •The FA5570 housing has an inside knockout to permit wires from power sources to be brought into the housing from behind the unit. •The FA5570 also has a removable shutter to permit wires to enter the housing from the side of the unit. Power Supply : •The FA5570 transformer requires an unswitched 120V A C p o w e r o u t l e t . •The transformer case should be secured to the electrical outlet to prevent acci- dental unplugging. •AC power requirement of repeater: 14VAC transformer (included). •Backup power requirement (optional): 12VDC. •Recommended wire requirements: 2-conductor 20AWG (or larger) stranded tinned copper with PVC insulation rated to 300 volts @ 80°. (Belden #8205, for example.) Maximum recommended wire length between transformer and repeater: 100 meters (328 feet). Measure voltage at repeater on long wire runs.( Source: Tech Note #1053.) •Wire runs should be hidden, stapled or protected by conduit. •Recommended power supply is 200mA, or 20VA at 14VAC. Wiring knockout Wiring shutter Mounting holes (4 places) AC BATTERY TEST DECODE TRANSMIT NOT ACTIVE AC AC B+ B- OUT RESET GND RESET AC Transformer Backup battery (opt ional) Not use d Test Button Reset Button NOTE: These components are not use in Version 1.41 (and earlier) TapWatch software. Functionality reserved for future versions. L I T- FA 5 5 7 0 - I N ST A L L 402775.fm 11/01/2001 L I T- FA 5 5 7 0 - I N ST A L L 402775.fm 11/01/2001                                         !"     #  $              % %        $  #    &    $'       %  ( ( %        )  * +)*,  $-         $ '   …

Text truncated - open the document above for the full version.

Attestation Statements

FCC ID: HCQ3B6SSRLA SSRLA Action Item #1: “Verify that the conducted power measurement was done in fixed frequency mode”. Peak conducted RF power output measurements: Pursuant to FCC Public Notice DA 00-705, the following measurements were made using an Agilent 8594E spectrum analyzer having the following settings: Span: 1450 kHz (approximately 5 times the 20dB bandwidth) RBW: 300 kHz (RBW > the 20dB bandwidth) VBW: 300 kHz (VWB ≥ RBW) Sweep: auto Detector: peak Trace: max hold The device is modified so that the antenna is removed and a 3” semi-rigid coaxial cable having negligible insertion loss connects it to the spectrum analyzer. Please note that the device is designed to have an output power of +23dBm however a variation of +1, -2dB is anticipated. Conducted power measurement in fixed frequency mode made at Inovonics Lab. Compliance with section 15.247(b)

Attestation Statements

FCC ID: HCQ3B6SSRLA SSRLA Action Item #3: “What are the lowest and highest carrier frequencies to be listed on the Grant”? Response: 906 – 920 MHz

Attestation Statements

FCC ID: HCQ3B6SSRLA SSRLA Action Item #4: “The Fundamental and Spurious emissions tables use a Duty Cycle Correction to calculate the average power. Average measurements are not permitted for frequencies below 1 GHz. Please submit a corrected table”. Response: Submitting corrected Test Report from IA Labs, which contains corrected table. File is entitled “SSRLA-CorrectedTestReport-April25-2005”.

Attestation Statements

FCC ID: HCQ3B6SSRLA SSRLA Action Item #6: “Verify that the signal is demodulated before retransmission”. The received signal is demodulated before retransmission. The system employs a modified pulse position modulation technique for both preamble and data packet. In operation, the receiver searches the band of frequencies from 906 to 920 MHz for transmissions with the proper characteristics. Upon recognizing a valid preamble, the receiver remains on the channel to complete reception of the packet. The message is decoded, processed and then retransmitted.

Cover Letter(s)

December 8, 2004 Federal Communications Commission Authorization and Standards Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Request for Confidentiality for FCC ID# HCQ3B6SSRLA Gentlemen: The following reports are marked confidential, and should be maintained in the non- public file. This confidentiality is necessary to protect proprietary information contained within these sections of the application for Certification. 1) Operational Description 2) Schematics 3) Block Diagram Thanks for your help. Sincerely, Donald J. Hume President

Cover Letter(s)

April 27, 2005 Federal Communications Commission OET Equipment Authorization Electronic Filing Attn: Andrew Leimer [email protected] Re: FCC ID: HCQ3B6SSRLA 731 CONFIRMATION #: EA315919 CORRESPONDENCE REFERENCE #: 28562 Andrew: In response to your correspondence reference number 28562, we are addressing the 6 action items and submitting the documents you are requesting. Action item #1: Submitting file entitled “ActionItem1-PowerMeasurements-SSRLA”. Action item #2: Submitting file entitled “ActionItem2-InternalPhoto-SSRLA”. Action item #3: Submitting file entitled “ActionItem3-CarrierFrequencies-SSRLA”. Action item #4: Submitting file entitled “ActionItem4-CorrectedEmissionsTable-SSRLA”, and Submitting file entitled “SSRLA-CorrectedReport-April25-2005”. Action item #5: Submitting file entitled “ActionItem5-RFexposureResponse-SSRLA”. Action item #6: Submitting file entitled “ActionItem6-DemodulatedSignal-SSRLA”. Please contact me if you have any questions. Thank you. Sincerely, Joni Ripper Engineering Assistant Phone: 303-209-7260 Email: [email protected]

External Photos

FCC ID: HCQ3B6SSRLA SSRLA 4. External Photos: Bottom view of housing Shows placement of the FCC label

ID Label/Location Info

CONFIDENTIAL DOCUMENT Confidential to InovonicsFA5570 FCC LabelRev A FA5570 FCC Label 04465A (Part No with Rev Letter) CONFIDENTIAL DOCUMENTATION The information contained in this document is confidential to and the sole property of Inovonics Corporation. Receipt of this information requires the existence and full acceptance of the terms and conditions of a Non Disclosure Agreement signed by the Inovonics Corporation and the Recipient. This documentation is not to be reproduced or redistributed except as provided in the Non Disclosure Agreement. AInitial release11/16/2004 MATERIAL: .002” THICK 3M 7381 VOIDABLE (TAMPER EVIDENT) WHITE MYLAR WITH .001” MATTE LAMINATION (FOR PROTECTION FROM INK SMEARING) AND PERMANENT ADHESIVE APPLIED TO THE BACKSIDE ARTWORK: NONE TEXT: BLACK WITH ARIAL FONT HAVING HIGHLIGHTING, SPACING, AND SIZES APPROXIMATELY AS SHOWN LABEL SIZE: 1 1/16” X 1 1/16” (SHOWN TO 3 TIMES SCALE) WITH .125 RADIUS ON EACH CORNER (NOT SHOWN) AND NO BORDER PACKAGING AND LABEL ORIENTATION: LABELS TO BE SUPPLIED ON TOP SIDE OF ROLL STOCK WITH TEXT READABLE AS VIEWED FROM BOTTOM (SHORT) EDGE OF ROLL Inovonics Wireless Corporation Louisville, Colorado FA5570 FCC ID: HCQ3B6SSRLA IC: 2309A-SSRLA This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Made in USA

Internal Photos

FCC ID: HCQ3B6SSRLA SSRLA 6. Internal photos: PCB Topside PCB Topside RF Shielding Integrated Antenna Shown without shield can FCC ID: HCQ3B6SSRLA SSRLA PCB bottomside

Internal Photos

FCC ID: HCQ3B6SSRLA SSRLA Action Item #2: “The internal photo has one can removed. Please submit the internal photo with both cans removed”. Front PCB with both shield cans removed.

RF Exposure Info

FCC ID: HCQ3B6SSRLA SSRLA 9. RF Exposure Information: The duty cycle is calculated over a 100 mSec averaging window as specified in the rules. The longest message contains a total of 213 pulses each 20 uSec in duration, for a total transmitter on time of 4.26 mSec which represents a worst-case duty cycle of 4.26%. The duty cycle correction used is the maximum of 10%. Calculation for compliance with MPE requirements (Section 2.1091) using a worst case of 0.25 Watt, unity antenna gain, and the f/300 (mW/cm 2 ) limit for general applications. This device is used in fixed locations and is not carried or worn by the end user. The key factor is duty cycle. Under normal conditions, a 12-packet message is sent a maximum of once every 15 minutes. Worst case, a 12-packet message is sent once per minute or 72 packets in a 6 minute period. Total On time per packet = 4.26 mSec (for maximum packet length) Duty Cycle = (4.26 x 72) mSec/(6x60x1000) mSec = 0.0852% EIRP = (0.25W)(0.000852) = 213 microwatt. Using a distance of 20 cm: 213 microwatt / (4 pi 20 2 ) = 42.38 nW/cm 2 The Dwell Time is the length of one packet. The worst case dwell time for an extended length packet is 40.1 mSec. The standard packet is about 30 mSec duration. A worst case transmission rate, corresponding to a repeated change of state transmissions would result in a maximum of 12 packets in any 10 second period with each packet on a different frequency. The maximum dwell time is thus the dwell time of an extended packet or 40.1 ms.

RF Exposure Info

FCC ID: HCQ3B6SSRLA SSRLA Action Item #5: “Submit the page of the User’s Manual with the RF exposure warning and required user separation distance from the antenna of 20 cm.” Rather than change the user manual, the device is shown to meet the requirements of 47CFR2.1093, at maximum duty cycle. The duty cycle is calculated over a 100 mSec averaging window as specified in the rules. The longest message contains a total of 213 pulses each 20 uSec in duration, for a total transmitter on time of 4.26 mSec which represents a worst-case duty cycle of 4.26%. This device is used in fixed locations and is not carried or worn by the end user. The time-averaged RF transmit power is then, mW ms packet ms packets mW213.0 1060 min126.4 min6 72 250 3 = × ××× Worst case, if all of the transmitted power were absorbed in a 1-gram sample of tissue, the power density is 0.213 mW/gram and is well below the 1.6 mW/gram limit found in 47CFR2.1093. The maximum duty cycle of the device is %0852.0000852.0 1060 min126.4 min6 72 3 == × ×× ms packet mspackets

Test Report

EMC EMISSIONS - TEST REPORT (In-Part) Test Report No. BC400231-1 Issue Date: July 1, 2004 Model / Serial No. SSRLA / 02304 109 Product Type Frequency Agile Repeater Client Inovonics Wireless Corp. Manufacturer Inovonics Wireless Corp. License holder Inovonics Wireless Corp. 315 CTC Blvd Address Louisville, CO 80027 Test Criteria Applied FCC CFR47 Part 15.247 Test Result PASS Test Project Number References BC400231-1 Total Pages Including Appendices: 33 Title 47 CFR 15: RADIO FREQUENCY DEVICES Reviewed By : Approved By : INTERNATIONAL APPROVALS LABORATORIES (IAL) reports apply only to the specific samples tested under stated test conditions. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. IAL have no liability for any deductions, inferences or generalizations drawn by the client or others from IAL issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval of IAL. This report shall not be used by the client to claim product endorsement by NVLAP (No. 200624- 0) or any agency of the US government. International Approval Laboratories and its professional staff hold government and professional organization certifications and are members of IEEE, NVLAP, and VCCI. Project File: BC400231 Page 2 of 33 International Approvals Laboratories, LLC 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999 Fax: 303 449 6160 Rev.No 1 D I R E C T O R Y Documentation Page(s) Test report 1 - 33 Directory 2 Test Regulations 3 General Remarks 4-5 Test-setup Photographs 6 - 10 Appendix A Test Data Sheets and Test Equipment Used 11-25 Appendix B Test Plan/Constructional Data Form 26-28 Appendix C Measurement Protocol/Test Procedures 29-33 STATEMENT OF MEASUREMENT UNCERTAINTY The data and results referenced in this document are true and accurate. The measurement uncertainty for Conducted Emissions in the frequency range of 150kHz – 30MHz is calculated to be ±2.30dB and for Radiated Emissions is calculated to be ±3.60dB in the frequency range of 30MHz – 200MHz and ±3.38dB in the frequency range of 200MHz – 1000MHz. EUT Received Date: 3-June-2004 Testing Start Date: 3-June-2004 Testing End Date: 6-July-2004 Project File: BC400231 Page 3 of 33 International Approvals Laboratories, LLC 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999 Fax: 303 449 6160 Rev.No 1 The tests were performed according to following regulations : 1. FCC CFR47 Part 15.205 2. FCC CFR47 Part 15.207 3. FCC CFR47 Part 15.209 4. FCC CFR47 Part 15.247 5. ICES-003 Emission Test Results: Conducted Emissions, Powerline (15.207) - Not Applicable Test Result Minimum limit margin NA dB at NA MHz Maximum limit exceeding dB at MHz Remarks: Radiated Emissions (15.209) - PASS Test Result Minimum limit margin -13.5 dB at 204.18 MHz Maximum limit exceeding dB at MHz Remarks: Radiated Emissions (15.205)/(15.247) (c) - PASS Test Result Minimum limit margin -8.58 dB at 2754.35 MHz Maximum limit exceeding dB at MHz Remarks: Peak Output Power (15.247) (b)(2) - PASS Test Result Minimum limit margin -15.28 dB at 912.59 MHz Maximum limit exceeding dB at MHz Remarks: Project File: BC400231 Page 4 of 33 International Approvals Laboratories, LLC 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999 Fax: 303 449 6160 Rev.No 1 GENERAL REMARKS: The following remarks are to be considered as “where applicable“ and are taken into account while completing any FCC/IC/ETSI radio tests at International Approvals Laboratories, LLC. Testing was performed in 3 different orthogonal axis to determine the worst case emissions from the device. The worst case emissions measurements are shown in this report. FCC CFR47 Part 15.31: Measurement Standards: In any case where the device is powered off a battery, a fresh battery was used during test. In cases where the device is powered off an AC supply, voltage was varied per Part 15.31 to find worst case emissions. FCC CFR47 Part 15.35: Measurement Detector Functions and Bandwidths: FCC Part 15.35 was utilized when performing the measurements within this report. In any case where the device is powered off a battery, a fresh battery was used during test. In cases where the device is powered off an AC supply, voltage was verified per Part 15.31 to find worst case emissions. The actual test distance for the FCC Part 15.209 testing was conducted at 10m for the fact that the device was being tested to EN55022 Class B from 30 MHz to 1000 MHz (meets/exceeds the FCC Part 15.209 & 109B limits) The data is automatically extrapolated back to the FCC 3m limits and measurements are corrected to better show the compliance to FCC requirements and reduce confusion. A correction factor of 10.54dB is used in cases of 30MHz and up for a difference between 10m and 3m measurement distances. All measurements that are lesser than 30MHz where applicable are accompanied with the fall of measurements and calculations to support the interpolation. Client requested that the name on the test report be changed from FA575 to SSRL November 2004. Modifications required to pass: Test Specification Deviations: Additions to or Exclusions from This test report is in-part, International Approvals Laboratories, LLC was asked to test only the field strength of the fundamental and harmonics as well as the unintentional radiated and conducted emissions when applicable. Project File: BC400231 Page 5 of 33 International Approvals Laboratories, LLC 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999 Fax: 303 449 6160 Rev.No 1 Required Information In Accordance to FCC CFR 47 Part 2.1033: Exhibits Including (where applicable): 1. Users Manual 2. Operation Description 3. Block Diagram 4. Report of Measurement 5. Exter…

Text truncated - open the document above for the full version.

Test Report

FCC ID: HCQ3B6SSRLA SSRLA 11. Test Report The test report containing intentional/unintentional emissions data is attached as “SSRLA FCC Test Report.pdf” (BC400231-1). International Approvals Laboratories generated this report. Additional data demonstrating compliance with 47CFR15.247 follows. For the following plots, an HP8594E spectrum analyzer was used. Plot 1 is a spectrum plot showing the carrier frequency separation. Compliance with section 15.247(a)(1) is demonstrated with a test sample configured with firmware allowing two adjacent channels to be captured. FCC ID: HCQ3B6SSRLA SSRLA Plot 2 demonstrates compliance with 15.247(a)(1)(i) — Number of hopping channels. This is a stored display of many sequential transmissions to show the overall band occupied by the transmitter. FCC ID: HCQ3B6SSRLA SSRLA Plot 3 shows the 20 dB bandwidth of a single channel to demonstrate compliance with 15.247(a)(1)(i). FCC ID: HCQ3B6SSRLA SSRLA Conducted Power Output: The antenna was removed and a coax was temporarily connected to allow for direct measurement of power using the spectrum analyzer. The power output was measured at +21 dBm measured into 50 ohms. Average time of occupancy measurement: Section 15.247(a)(1)(i) stated, “...if the 20 dB bandwidth of the hopping channel is 250kHz or greater, the system shall use at least 25 hopping frequencies and the average time of occupancy on any frequency shall not be greater than 0.4 seconds within a 10 second period”

Test Report

EMC EMISSIONS - TEST REPORT (In-Part) Test Report No. BC400231-1 Issue Date: July 1, 2004 Model / Serial No. SSRLA / 02304 109 Product Type Frequency Agile Repeater Client Inovonics Wireless Corp. Manufacturer Inovonics Wireless Corp. License holder Inovonics Wireless Corp. 315 CTC Blvd Address Louisville, CO 80027 Test Criteria Applied FCC CFR47 Part 15.247 Test Result PASS Test Project Number References BC400231-1 Total Pages Including Appendices: 33 Title 47 CFR 15: RADIO FREQUENCY DEVICES Reviewed By : Approved By : INTERNATIONAL APPROVALS LABORATORIES (IAL) reports apply only to the specific samples tested under stated test conditions. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. IAL have no liability for any deductions, inferences or generalizations drawn by the client or others from IAL issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval of IAL. This report shall not be used by the client to claim product endorsement by NVLAP (No. 200624- 0) or any agency of the US government. International Approval Laboratories and its professional staff hold government and professional organization certifications and are members of IEEE, NVLAP, and VCCI. Project File: BC400231 Page 2 of 33 International Approvals Laboratories, LLC 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999 Fax: 303 449 6160 Rev.No 1 D I R E C T O R Y Documentation Page(s) Test report 1 - 33 Directory 2 Test Regulations 3 General Remarks 4-5 Test-setup Photographs 6 - 10 Appendix A Test Data Sheets and Test Equipment Used 11-25 Appendix B Test Plan/Constructional Data Form 26-28 Appendix C Measurement Protocol/Test Procedures 29-33 STATEMENT OF MEASUREMENT UNCERTAINTY The data and results referenced in this document are true and accurate. The measurement uncertainty for Conducted Emissions in the frequency range of 150kHz – 30MHz is calculated to be ±2.30dB and for Radiated Emissions is calculated to be ±3.60dB in the frequency range of 30MHz – 200MHz and ±3.38dB in the frequency range of 200MHz – 1000MHz. EUT Received Date: 3-June-2004 Testing Start Date: 3-June-2004 Testing End Date: 6-July-2004 Project File: BC400231 Page 3 of 33 International Approvals Laboratories, LLC 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999 Fax: 303 449 6160 Rev.No 1 The tests were performed according to following regulations : 1. FCC CFR47 Part 15.205 2. FCC CFR47 Part 15.207 3. FCC CFR47 Part 15.209 4. FCC CFR47 Part 15.247 5. ICES-003 Emission Test Results: Conducted Emissions, Powerline (15.207) - Not Applicable Test Result Minimum limit margin NA dB at NA MHz Maximum limit exceeding dB at MHz Remarks: Radiated Emissions (15.209) - PASS Test Result Minimum limit margin -13.5 dB at 204.18 MHz Maximum limit exceeding dB at MHz Remarks: Radiated Emissions (15.205)/(15.247) (c) - PASS Test Result Minimum limit margin -8.58 dB at 2754.35 MHz Maximum limit exceeding dB at MHz Remarks: Peak Output Power (15.247) (b)(2) - PASS Test Result Minimum limit margin -15.28 dB at 912.59 MHz Maximum limit exceeding dB at MHz Remarks: Project File: BC400231 Page 4 of 33 International Approvals Laboratories, LLC 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999 Fax: 303 449 6160 Rev.No 1 GENERAL REMARKS: The following remarks are to be considered as “where applicable“ and are taken into account while completing any FCC/IC/ETSI radio tests at International Approvals Laboratories, LLC. Testing was performed in 3 different orthogonal axis to determine the worst case emissions from the device. The worst case emissions measurements are shown in this report. FCC CFR47 Part 15.31: Measurement Standards: In any case where the device is powered off a battery, a fresh battery was used during test. In cases where the device is powered off an AC supply, voltage was varied per Part 15.31 to find worst case emissions. FCC CFR47 Part 15.35: Measurement Detector Functions and Bandwidths: FCC Part 15.35 was utilized when performing the measurements within this report. In any case where the device is powered off a battery, a fresh battery was used during test. In cases where the device is powered off an AC supply, voltage was verified per Part 15.31 to find worst case emissions. The actual test distance for the FCC Part 15.209 testing was conducted at 10m for the fact that the device was being tested to EN55022 Class B from 30 MHz to 1000 MHz (meets/exceeds the FCC Part 15.209 & 109B limits) The data is automatically extrapolated back to the FCC 3m limits and measurements are corrected to better show the compliance to FCC requirements and reduce confusion. A correction factor of 10.54dB is used in cases of 30MHz and up for a difference between 10m and 3m measurement distances. All measurements that are lesser than 30MHz where applicable are accompanied with the fall of measurements and calculations to support the interpolation. Client requested that the name on the test report be changed from FA575 to SSRL November 2004. Modifications required to pass: Test Specification Deviations: Additions to or Exclusions from This test report is in-part, International Approvals Laboratories, LLC was asked to test only the field strength of the fundamental and harmonics as well as the unintentional radiated and conducted emissions when applicable. Project File: BC400231 Page 5 of 33 International Approvals Laboratories, LLC 5541 Central Avenue, Suite 110 Boulder, Colorado 80301 Voice: 303 786 7999 Fax: 303 449 6160 Rev.No 1 Required Information In Accordance to FCC CFR 47 Part 2.1033: Exhibits Including (where applicable): 1. Users Manual 2. Operation Description 3. Block Diagram 4. Report of Measurement 5. Exter…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: HCQ3B6SSRLA SSRLA 12. Test Setup Photos The test setup photos are contained within the test report of the previous section.

Contact Information

Applicant

Jess Cobb(Manager of Program Mgmt)
[email protected]13032097290Fax: 13032097243

Technical Contact

Inovonics Wireless Corp.Hans Balderrama
[email protected]303-209-7202

315 CTC Blvd. · Louisville, Colorado · United States

Non-Technical Contact

Inovonics Wireless Corp.Joni Ripper
[email protected]303-209-7912

Test Firm

International Approval Laboratories, LLCTodd Seeley
[email protected]303-402-5272Fax: 303-449-6160

Technical Specifications

#Rule PartsFrequency RangePower Output
115C906 MHz - 920 MHz250.00 mW
Confidentiality
Long Term

Other Applications from Inovonics Wireless Corporation

Inovonics Wired Touchscreen Keypad - FCC ID HCQ-IDTOUCH1 - Inovonics Wireless Corporation
HCQ-IDTOUCH1

Inovonics Wired Touchscreen Keypad

May 13, 2026

Equipment Class

DTS - Digital Transmission System
Flush Mount Locator - FCC ID HCQBWA02 - Inovonics Wireless Corporation
HCQBWA02

Flush Mount Locator

Aug 28, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
TBA Module - FCC ID HCQTBA - Inovonics Wireless Corporation
HCQTBA

TBA Module

Sep 21, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Fall Detect Transmitter - FCC ID HCQPFA01 - Inovonics Wireless Corporation
HCQPFA01

Fall Detect Transmitter

Jul 14, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Bluetooth to EchoStream Bridge - FCC ID HCQ3B6BRGSA - Inovonics Wireless Corporation
HCQ3B6BRGSA

Bluetooth to EchoStream Bridge

Sep 22, 2020

Equipment Class

DTS - Digital Transmission System