Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jan 29, 2013
Application Purpose
Original Equipment
Date of Application
Jan 29, 2013
Equipment Note
PDA Scanner
Frequency Range
2402.00000000 - 2480.00000000
Company
Unitech Electronics Co., Ltd.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗
↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

HT650 Rugged Handheld Terminal - HT650 - User’s Manual 400992G Version 0.1 i About This Manual Preface This manual explains how to install, operate and maintain the HT650 Rugged Enterprise Terminal. No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, without permission in writing from the manufacturer. This includes electronic or mechanical means, such as photocopying, recording, or information storage and retrieval systems. The material in this manual is subject to change without notice. © Copyright 2012 Unitech Electronics Co., Ltd. All rights reserved. Unitech global website address: http:\\www.unitech-adc.com Bluetooth is a registered trademark of Bluetooth SIG. Microsoft, Windows and ActiveSync are either registered trademarks or trademarks of Microsoft Corporation. Other product names mentioned in this manual may be trademarks or Registered trademarks of their respective companies and are hereby acknowledged. Unitech is a member of Oracle Embedded Software Licensing Program. Regulatory Compliance Statements FCC Warning Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ii –Reorient or relocate the receiving antenna. –Increase the separation between the equipment and receiver. –Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. –Consult the dealer or an experienced radio/TV technician for help. 1. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. To maintain compliance with FCC RF exposure compliance requirements, avoid direct contact to the transmitting antenna during transmitting. 3. Any changes or modifications (including the antennas) made to this device that are not expressly approved by the manufacturer may void the user’s authority to operate the equipment. FCC Label Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. FOR PORTABLE DEVICE USAGE (<20m from body/SAR needed) Radiation Exposure Statement: The product comply with the FCC portable RF exposure limit set forth for an uncontrolled environment and are safe for intended operation as described in this manual. The further RF exposure reduction can be achieved if the product can be kept as far as possible from the user body or set the device to lower output power if such function is available. FOR COUNTRY CODE SELECTION USAGE (WLAN DEVICES) Note: The country code selection is for non-US model only and is not available to all US model. Per FCC regulation, all WiFi product marketed in US must fixed to US operation channels only. RF Radiation Exposure Statement: For body worn operation, this phone has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the handset a minimum of 1.5 cm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. iii Canadian Compliance Statement This Class B Digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numerique de la classe B respecte les exigences du Reglement sur le material broilleur du Canada. European Conformity Statement Declaration of Conformity with Regard to the R&TTE 1999/5/EC and EMC 89/336/ EEC directives. RoHS Statement This device conforms to RoHS (Reduction Of Hazardous Sub-stances) European Union regulations that set maximum concentration limits on hazardous materials used in electrical and electronic equipment. Taiwan NCC Warning Statement 交通部電信總局低功率電波輻射性電機管理辦法 (930322) 根據交通部低功率管理辦法規定: 第十二條 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更 頻率、加大功率或變更原設計之特性及功能。 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應 立即停用,並改善至無干擾時方得繼續使用。前項合法通信,指依電信法規定作業之 無線電通信。 低功率射頻電機須忍受合法通信或工業、 科學及醫療用電波輻射性電機設備之干擾。 SAR標準值2.0W/Kg;送測產品為 W/Kg 為減少電磁波,請妥適使用 Laser Information The Unitech HT650 series is certified in the U.S. to conform to the requirements of DHHS/CDRH 21CFR Subchapter J and to the requirements of IEC 825-1. Class II and Class 2 products are not considered to be hazardous. The HT650 series contains internally a Visible Laser Diode (VLD) whose emissions do not exceed the maximum limits as set forth in the above regulations. The scanner is designed so that there is no human access to harmful laser light during normal operation, user maintenance or during prescribed service operations. The laser safety warning label required by the DHHS/IEC for the HT650 series' optional laser scanner module is located on the memory compartment cover, on the back of the unit. iv CAUTION! Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light. Use of optical instruments with the scanner will increase eye hazard. Optical instruments include binoculars, microscopes, and magnifying glasses. This does not include eyeglasses worn by the user. Battery Notices Th…

Text truncated - open the document above for the full version.

Attestation Statements

/ Product Manger/Enterprise Mobile Computer

Cover Letter(s)

Product Manger/Enterprise Mobile Computer

Cover Letter(s)

/ Product Manger/Enterprise Mobile Computer

Cover Letter(s)

Product Manger/Enterprise Mobile Computer

External Photos

Page 1 CONSTRUCTION PHOTOS OF EUT Page 2 Page 3 Page 4

ID Label/Location Info

1:1 2:1 Vicki-lin 100% Size Print Reference 24.60 20.60 C2.0 R0.90 T=0.11 含背膠 Model No label for UNITECH Model No label for UNITECH HT650 R35280 R35280 BITATEK CO., LTD. BITATEK CO., LTD. 鋇鎝科技股份有限公司 鋇鎝科技股份有限公司

Internal Photos

Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16

Operational Description

FCC ID: HLEHT650BTG Report No.: RF991214C29G Operational Description This device is a PDA Scanner; which operate in 2.4GHz band; the maximum data rate could be up to 54Mbps which OFDM technique. If the signal to noise radio is too poor which could not support 54Mbps, the 11Mbps data rate with DSSS technique will be applied. The transmitter of the EUT is powered by the 5Vdc from power adapter or by the 3.7Vdc from batteries. The antenna is Embedded Dual-band Antenna with U.FL (Hirose) antenna connector (WLAN) and PIFA antenna without antenna connector (Bluetooth). The other instruction, please have a look at the users manual.

RF Exposure Info

Report No.: SA991214C29G-1 R1 1 of 6 Report Format Version 5.0.0 Reference No.: 121127C18 Cancels and replaces the report No.: SA991214C29G-1 dated Dec. 20, 2012. RF EXPOSURE REPORT REPORT NO.: SA991214C29G-1 R1 MODEL NO.: HT650 FCC ID: HLEHT650BTG RECEIVED: Nov. 27, 2012 TESTED: Dec. 12 ~ Dec. 14, 2012 ISSUED: Jan. 02, 2013 APPLICANT: Unitech Electronics Co., Ltd. ADDRESS: 5F., No. 136, Lane 235, Pao-Chiao Rd.,Hsin-Tien Dist., New Taipei City, Taiwan ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-com pliance to the specification. Report No.: SA991214C29G-1 R1 2 of 6 Report Format Version 5.0.0 Reference No.: 121127C18 Cancels and replaces the report No.: SA991214C29G-1 dated Dec. 20, 2012. TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................................. 3 1. CERTIFICATION .......................................................................................................... 4 2. EVALUATION RESULT ............................................................................................... 5 3. SAR TEST EXCLUSION THRESHOLDS .................................................................... 6 4. CONCLUSION ............................................................................................................. 6 Report No.: SA991214C29G-1 R1 3 of 6 Report Format Version 5.0.0 Reference No.: 121127C18 Cancels and replaces the report No.: SA991214C29G-1 dated Dec. 20, 2012. RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED SA991214C29G-1 Original release. Dec. 20, 2012 SA991214C29G-1 R1 Updated product name and brand name. Jan. 02, 2013 Report No.: SA991214C29G-1 R1 4 of 6 Report Format Version 5.0.0 Reference No.: 121127C18 Cancels and replaces the report No.: SA991214C29G-1 dated Dec. 20, 2012. 1. CERTIFICATION PRODUCT: PDA Scanner MODEL: HT650 BRAND: Unitech APPLICANT: Unitech Electronics Co., Ltd. TESTED: Dec. 12 ~ Dec. 14, 2012 TEST SAMPLE: ENGINEERING SAMPLE STANDARDS: FCC Part 2 (Section 2.1093) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 The above equipment (Model: HT650) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE : Jan. 02, 2013 Polly Chien / Specialist APPROVED BY : , DATE : Jan. 02, 2013 Ken Liu / Manager Report No.: SA991214C29G-1 R1 5 of 6 Report Format Version 5.0.0 Reference No.: 121127C18 Cancels and replaces the report No.: SA991214C29G-1 dated Dec. 20, 2012. 2. EVALUATION RESULT Following FCC KDB 447498 D01 “General SAR test exclusion guidance” The corresponding SAR Exclusion Threshold condition, listed below: 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16 where ¾ f(GHz) is the RF channel transmit frequency in GHz ¾ Power and distance are rounded to the nearest mW and mm before calculation ¾ The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is determined according to the following: a) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)] mW, at 100MHz to 1500 MHz b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤ 6 GHz 3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion. a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm. b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test separation distances ≤ 50 mm. c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion …

Text truncated - open the document above for the full version.

RF Exposure Info

FCC SAR Test Report Report Format Version 5.0.0 Page No. : 1 of 19 Report No. : SA121127C18 Issued Date : Jan. 02, 2013 Revision : R02 FCC SAR Test Report Report No. : SA121127C18 Applicant : Unitech Electronics Co., Ltd. Address : 5F., No. 136, Lane 235, Pao-Chiao Rd., Hsin-Tien Dist., New Taipei City, Taiwan Product : PDA Scanner FCC ID : HLEHT650BTG Brand : Unitech Model No. : HT650 Standards : FCC 47 CFR Part 2 (2.1093) / IEEE C95.1:1991 / IEEE 1528:2003 FCC OET Bulletin 65 Supplement C (Edition 01-01) KDB 248227 D01 v01r02 / KDB 447498 D01 v04 Date of Testing : Dec. 19, 2012 CERTIFICATION: The above equipment have been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch - Taiwan HwaYa Lab, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s SAR characteristics under the conditions specified in this report. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product certification, approval, or endorsement by TAF or any government agencies. Prepared By : Evonne Liu / Specialist Approved By : Roy Wu / Manager This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. FCC SAR Test Report Report Format Version 5.0.0 Page No. : 2 of 19 Report No. : SA121127C18 Issued Date : Jan. 02, 2013 Revision : R02 Table of Contents Release Control Record ............................................................................................................................................................... 3 1. Summary of Maximum SAR Value ....................................................................................................................................... 4 2. Description of Equipment Under Test ................................................................................................................................. 5 3. SAR Measurement System ................................................................................................................................................... 6 3.1 Definition of Specific Absorption Rate (SAR) ................................................................................................................ 6 3.2 SPEAG DASY System ................................................................................................................................................. 6 3.2.1 Robot.................................................................................................................................................................. 7 3.2.2 Probes ................................................................................................................................................................ 8 3.2.3 Data Acquisition Electronics (DAE) .................................................................................................................... 8 3.2.4 Phantoms ........................................................................................................................................................... 9 3.2.5 Device Holder ................................................................................................................................................... 10 3.2.6 System Validation Dipoles ................................................................................................................................ 10 3.2.7 Tissue Simulating Liquids ................................................................................................................................. 11 3.3 SAR System Verification ............................................................................................................................................ 12 3.4 SAR Measurement Procedure ................................................................................................................................... 13 3.4.1 Area & Zoom Scan Procedure ......................................................................................................................... 13 3.4.2 Volume Scan Procedure................................................................................................................................... 13 3.4.3 Power Drift Monitoring ...................................................................................................................................... 13 3.4.4 Spatial Peak SAR Evaluation ........................................................................................................................... 14 3.4.5 SAR Averaged Methods .....................................…

Text truncated - open the document above for the full version.

Test Report

Report No.: RF991214C29G-1 R1 1 of 48 Report Format Version 5.0.0 Reference no.: 121127C18 Cancels and replaces the report No.: RF991214C29G-1 dated Dec. 20, 2012. FCC TEST REPORT (BLUETOOTH) REPORT NO.: RF991214C29G-1 R1 MODEL NO.: HT650 FCC ID: HLEHT650BTG RECEIVED: Nov. 27, 2012 TESTED: Dec. 12 ~ Dec. 14, 2012 ISSUED: Jan. 02, 2013 APPLICANT: Unitech Electronics Co., Ltd. ADDRESS: 5F., No. 136, Lane 235, Pao-Chiao Rd.,Hsin-Tien Dist., New Taipei City, Taiwan ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan ( R.O.C. ) TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the com pliance or non-compliance to the specification This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF991214C29G-1 R1 2 of 48 Report Format Version 5.0.0 Reference no.: 121127C18 Cancels and replaces the report No.: RF991214C29G-1 dated Dec. 20, 2012. Table of Contents RELEASE CONTROL RECORD ......................................................................................................... 4 1. CERTIFICATION ..................................................................................................................... 5 2. SUMMARY OF TEST RESULTS ............................................................................................. 6 2.1 MEASUREMENT UNCERTAINTY .......................................................................................... 6 3. GENERAL INFORMATION ...................................................................................................... 7 3.1 GENERAL DESCRIPTION OF EUT ........................................................................................ 7 3.2 DESCRIPTION OF TEST MODES .......................................................................................... 8 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ......................................... 9 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ....................................................... 11 3.4 DESCRIPTION OF SUPPORT UNITS .................................................................................. 11 3.4.1 CONFIGURATION OF SYSTEM UNDER TEST ................................................................... 11 4. TEST TYPES AND RESULTS ............................................................................................... 12 4.1 RADIATED EMISSION AND BANDEDGE MEASUREMENT ............................................... 12 4.1.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT ............................ 12 4.1.2 TEST INSTRUMENTS .......................................................................................................... 13 4.1.3 TEST PROCEDURES ........................................................................................................... 14 4.1.4 DEVIATION FROM TEST STANDARD ................................................................................. 14 4.1.5 TEST SETUP ......................................................................................................................... 15 4.1.6 EUT OPERATING CONDITIONS .......................................................................................... 15 4.1.7 TEST RESULTS .................................................................................................................... 16 4.2 CONDUCTED EMISSION MEASUREMENT ........................................................................ 23 4.2.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ..................................................... 23 4.2.2 TEST INSTRUMENTS .......................................................................................................... 23 4.2.3 TEST PROCEDURES ........................................................................................................... 24 4.2.4 DEVIATION FROM TEST STANDARD ................................................................................. 24 4.2.5 TEST SETUP ......................................................................................................................... 25 4.2.6 EUT OPERATING CONDITIONS .......................................................................................... 25 4.2.7 TEST RESULTS .................................................................................................................... 26 4.3 NUMBER OF HOPPING FREQUENCY USED ..................................................................... 28 4.3.1 LIMIT OF HOPPING FREQUENCY USED ........................................................................... 28 4.3.2…

Text truncated - open the document above for the full version.

Test Report

Report No.: RF991214C29G R1 1 of 40 Report Format Version 5.0.0 Reference no.: 121127C18 Cancels and replaces the report No.: RF991214C29G dated Dec. 20, 2012. FCC TEST REPORT REPORT NO.: RF991214C29G R1 MODEL NO.: HT650 FCC ID: HLEHT650BTG RECEIVED: Nov. 27, 2012 TESTED: Dec. 12 ~ Dec. 14, 2012 ISSUED: Jan. 02, 2013 APPLICANT: Unitech Electronics Co., Ltd. ADDRESS: 5F., No. 136, Lane 235, Pao-Chiao Rd.,Hsin-Tien Dist., New Taipei City, Taiwan ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-com pliance to the specification. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF991214C29G R1 2 of 40 Report Format Version 5.0.0 Reference no.: 121127C18 Cancels and replaces the report No.: RF991214C29G dated Dec. 20, 2012. TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................................ 4 1. CERTIFICATION ............................................................................................................ 5 2. SUMMARY OF TEST RESULTS .................................................................................... 6 2.1 MEASUREMENT UNCERTAINTY .................................................................................. 6 3. GENERAL INFORMATION ............................................................................................. 7 3.1 GENERAL DESCRIPTION OF EUT ............................................................................... 7 3.2 DESCRIPTION OF TEST MODES ................................................................................. 8 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ................................. 9 3.3 DESCRIPTION OF SUPPORT UNITS .......................................................................... 11 3.3.1 CONFIGURATION OF SYSTEM UNDER TEST ........................................................... 11 3.4 GENERAL DESCRIPTION OF APPLIED STANDARDS .............................................. 12 4. TEST TYPES AND RESULTS ...................................................................................... 13 4.1 RADIATED EMISSION AND BANDEDGE MEASUREMENT ....................................... 13 4.1.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT .................... 13 4.1.2 TEST INSTRUMENTS .................................................................................................. 14 4.1.3 TEST PROCEDURES .................................................................................................. 15 4.1.4 DEVIATION FROM TEST STANDARD ........................................................................ 15 4.1.5 TEST SETUP ................................................................................................................ 16 4.1.6 EUT OPERATING CONDITIONS ................................................................................. 16 4.1.7 TEST RESULTS ........................................................................................................... 17 4.2 CONDUCTED EMISSION MEASUREMENT ............................................................... 24 4.2.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ............................................. 24 4.2.2 TEST INSTRUMENTS ..............................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ben Chiang
[email protected]886-2-8912-1122Fax: 886-2-8912-1391

Test Firm

Bureau Veritas CPS (H.K.) Ltd., Taoyuan BranchRichard Chen
[email protected]+886-3-2600884Fax: +886-3-2115834

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.00 mW
Confidentiality
Long Term
Grant Notes
Output power is conducted. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except as evaluated in this filing. End users must be informed of the body worn requirements for satisfying RF exposure compliance.

Other Applications from Unitech Electronics Co., Ltd.

RG768 Plus gun grip - FCC ID HLERG768PU - Unitech Electronics Co., Ltd.
HLERG768PU

RG768 Plus gun grip

Jul 29, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
HLEEA530BWNWU

Rugged Handheld Computer

Feb 16, 2026

Equipment Class

DTS - Digital Transmission System
HLEEA530BWNW

Rugged Handheld Computer

Feb 16, 2026

Equipment Class

6XD - 15E 6 GHz Low Power Indoor Client
RP300 UHF RFID Mobile Reader - FCC ID HLERP300BU - Unitech Electronics Co., Ltd.
HLERP300BU

RP300 UHF RFID Mobile Reader

Nov 24, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
RM300 Plus UHF RFID Reader Module - FCC ID HLERM300PU - Unitech Electronics Co., Ltd.
HLERM300PU

RM300 Plus UHF RFID Reader Module

Sep 01, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter