FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Panasonic Healthcare Co., Ltd./
  3. IUO9TB095DSS

IUO9TB095DSSDDS Storage Device

Panasonic Healthcare Co., Ltd.
DDS Storage Device - FCC ID IUO9TB095DSS - Panasonic Healthcare Co., Ltd.
Click to zoom

Application Details

Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Date of Grant
Sep 18, 2002
Application Purpose
Original Equipment
Date of Application
Sep 18, 2002
Equipment Note
DDS Storage Device
Company
Panasonic Healthcare Co., Ltd.
Country
Japan

Documents & Files

Select a file to view

Users Manual

β†—

Block Diagram

β†—

Cover Letter(s)

β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—
β†—

Internal Photos

β†—

Test Report

β†—
β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

DDS BACKUP LIBRARY LKM-SD21-S INSTRUCTION MANUAL Please read through these instructions before operating this unit. IMPORTANT SAFETY NOTICE LMQT00583 For USA CAUTION : Use shielded connecting cables in order to meet FCC emission limits and also to prevent interference to nearby radio and television reception. FEDERAL COMMUNICATIONS COMMISSION (FCC) RADIO FREQUENCY INTERFERENCE STATEMENT Class B Computing Device NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and , if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures : - - Reorient or relocate the receiving antenna. - - Increase the separation between the equipment and receiver. - - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - - Consult the dealer or an experienced radio/TV technician for help. FCC WARNING : Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTICE (1) You may not reproduce or transcribe any part of this publication without permission. (2) We reserve the right to revise this document at any time without notice. (3) If you have any questions about this document, contact your sales representative. SAFETY NOTICE (1) To prevent fire or electric shock, do not expose this appliance to rain or moisture. (2) To avoid electric shock, do not attempt to disassemble the cabinet. (3) For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily accessible. IMPORTANT SAFETY INSTRUCTIONS 1. Read all of these instructions. 2. Save these instructions for later use. 3. Follow all warnings and instructions marked on the product. 4.Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 5. Do not use this product near water. 6. Do not place this product on an unstable rack, cart, stand, or table. The product may fall, causing serious damage to the product. 7.This product should be operated from the type of power source indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power company. 8.This product is equipped with a 3-wire grounding type plug, a plug having a third (grounding) pin. This plug will only fit into a grounding-type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the purpose of the grounding-type plug. 9.Do not allow anything to rest on the power cord. Do not locate this product where persons will walk on the cord. 10.If an extension cord is used with this product, make sure that the total of the ampere ratings on the products plugged into the extension cord do not exceed the extension cord ampere rating. Also, make sure that the total of all products plugged into the wall outlet does not exceed 15 amperes. 11.Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electric shock. Never spill liquid of any kind on the product. 12. Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous voltage points or other risks. Refer all servicing to service personnel. 13.Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions: A. When the power cord or plug is damaged or frayed. B. If liquid has been spilled into the product. C. If the product has been exposed to rain or water. D. If the product does not operate normally when the operating instructions are followed. Adjust only those controls that are covered by the operating instructions since improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to normal operation. E. If the product has been dropped or the cabinet has been damaged. F.If the product exhibits a distinct change in performance, indicating a need for service. 14. Slots and openings in the cabinet and back or bottom are provided for ventilation and to ensure reliable operation of the product and to protect it from overheating. These openings must not be blocked or covered. KIT CONTENTS β–  DDS Backup Library Unit β–  Power Cable β–  Safety Instruction Manual Recommended Kits β—† SCSI Interface Board Adaptec SCSI narrow (AHA-2940 series) β—† Terminator (for SCSI daisy Chain) P/N: ACK-68 TERM KIT (1718100) ( by Adaptec ) β—† Rack Please use the suitable rack for this Library. ( should be based on EIA standard ) β—† Angle or Rail (Rail-Bracket) for Installing into Rack Please use the suitable angle or rail for the Library and Rack. ( should be based on EIA standard ) β—† Application Software ( for Writing / Reading ) ARCserve NetVault ( by BakBone Software ) Backup Exec ( by VERITAS Software Corporation ) β—† Cartridge Tape Fuji Film ( DDS-4, P/N: DG4-150M ) β—† Cleaning Tape Fuji Film ( P/N: DDS DG-15CL WS ), Sony ( P/N: DGD15CL ) –––– If Daisy Chain Connection ( for EMC: Electro-Magnetic Compatibility) –––– β—† SCSI interface cable Adaptec ( P/N: ACK / WP-WP ) β—† Ferrite-Core TDK ( P/N: ZCAT2436-1330A-M ) Th…

Text truncated - open the document above for the full version.

Block Diagram

55 44 33 22 11 D D C C B B A A SCSI BUS LCD DisplayControl Switches FrontView BottomView Connector(for maintenance)Power LED(Green)Status LEDs Door Open Door Close CassetteOrigin2 CassetteOrigin TurntableOrigin SCSI ID SwitchSCSI Connector AC inlet,power switch,SCSI connector and SCSI ID switch take out direct outside. SCSI BUSAC InletPower switch Foward/Back Origin Foward/Back Origin2 Up/Down Origin Cassette existence Clamp Open/Close U V W Hole Sensor +12V/+5V/+3.3V +12V/+5V/+3.3V +12V/+5V/+3.3V +12V/+5V +12V/+5V +12V/+5V +5V +12V/+5V +12V/+5V +5V/+3.3V +5V/+3.3V Caution Block Diagram MKE 1.0 B 11 Friday, May 31, 2002 TitleSize Document Number Rev Date: Sheet of Power SupplyPSMxxxx CN1[1..9]CN2[1..5]CN3[1..2] CN4[1..3] Cassette Motor PCBLMJB0712A CN1[1..12] CN2[1..2] DDS DriveScorpion40 SP CN1001[81..84] CN1006[1..6]CN1010[1..15] CN1001[1..68] Loader Main PCBLMJB0707A CN1[1..26]CN2[1..80] CN8[1..9] CN7[1..4] CN6[1..3]CN10[1..3]CN9[1..3] Connector<Value> CN1[1..3] Bottom PCBLMJB0708A CN5[1..16]CN7[1..30] CN9[1..6] CN15[1..3] CN3[1..12] CN4[1..14] CN11[1..4] CN12[1..15] CN1[1..4]CN6[1..4]CN8[1..22]CN2[1..80] CN14[1..3] Cassette Sensor PCBLMJB0713A CN1[1..14] CN3[1..3]CN4[1..3] Door PCBLMJB0714A CN4[1..6] CN2[1..2]CN5[1..3]CN3[1..3] CN1[1..16] LCD PCBLMJB0709A CN1[1..30] Front PCBLMJB0722A CN1[1..6] ABS PCBLMJB0721A CN3[1..136]CN2[1..5]CN5[1..5]CN8[1..2]CN7[1..6] CN1[1..68] CN6[1..3] Turntable PCBLMJB0710A CN1[1..22] CN2[1..11] Eleveter PCBLMJB0711A CN1[1..26] CN9[1..3] CN10[1..3] CN3[1..4]CN6[1..3]CN2[1..4]CN7[1..3]CN8[1..3]CN4[1..4] M9Turntable Motor M4 Fan Motor Y230MHz M8 Cassette Clamp M3 Fan Motor M1 Door Motor Y130MHz M6 Eleveter Foward/Back M5 Fan Motor M7 Eleveter Up/Down M2 Cassette Guard Motor

Cover Letter(s)

Akzo Nobel K. K. EMC Division Bancho Kaikan 12-1, Gobancho, Chiyoda-ku Tokyo 102-0076 Japan Tel.+81 3 5210 5411 Fax.+81 3 5216 2860 September 11, 2002 Federal Communications Commission Office of Engineering and Technology 7435 Oakland Mills Road Columbia, MD 21046 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize MET Laboratories, Inc. to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988,21 U.S.C.862. This authorization expires one year from the current date. Sincerely, Akzo Nobel K. K. Izumi Mitsui Technology Management Group EMC Division

Cover Letter(s)

Matsushita Kotobuki Electronics Industries Ltd. Storage Products Business Unit Address: 2131-1 Minamigata, Kawauchi-cho, Onsen, Ehime 791 – 0395 Japan attn:Reviewing Engineer Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize MET Laboratories, Inc. to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988,21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Date : Sep 11, 2002 Signature : Printed name : Shinji Yamauchi Company name : Matsushita Kotobuki Electronics Ind.,Ltd. Storage Products Business Unit Legal Affairs Team.

Test Report

1 Marianne Bosley From: Marianne Bosley Sent: Friday, September 13, 2002 9:32 AM To: Marianne Bosley Subject: FW: Matsushita Kotobuki FCC ID:IUO9TB095DSS - DL into folder -----Original Message----- From: MITSUI Izumi To: Marianne Bosley Cc: Chris Harvey; Greg Czumak Sent: 9/13/2002 2:53 AM Subject: Re: Matsushita Kotobuki FCC ID:IUO9TB095DSS Hi Marianne, Again me. The applicant, Matsushita Kotobuki, has decided to retest the EUT without the ferrite on its cable and also with new conduction limit. I will send you new test report as soon as I get it. Thank you! Best Regards, Izumi Mitsui Technology Management Group, EMC Division Akzo Nobel K. K. Tel. +81 3 5210 5411 Fax. +81 3 5216 2860 e-mail: [email protected] http://www.akzoemc.co.jp ----- Original Message ----- From: "Marianne Bosley" <[email protected]> To: <[email protected]> Cc: "Chris Harvey" <[email protected]>; "Greg Czumak" <[email protected]> Sent: Friday, September 13, 2002 6:12 AM Subject: Matsushita Kotobuki FCC ID:IUO9TB095DSS > Hello Izumi, > > The technical review has been completed. Below are the issues that you need > to address: > > 1. During testing, the EUT was attached to another storage device > ("daisy chain" configuration) by means of a shielded I/O cable with a > ferrite attached. The applicant must either provide this ferrite loaded > cable with every unit that they sell, or, the EUT must be retested without > the ferrite on this cable, and new data demonstrating compliance with the 2 > technical requirements of Section 15.109 must be submitted. Please indicate > their choice in this matter. > 2. The limits to which the AC Line conducted measurements were compared > are no longer the current limits listed in Section 15.107. This Rule has > been amended to bring it into alignment with the CISPR 22 limits. As a > result, the lower frequency range for testing is now 150 kHz, and no longer > 450 kHz. Pursuant to Section 15.37(j), if the EUT is approved with the > current test data, new data demonstrating compliance with the new limits, > over the new frequency range, must be submitted by July 10, 2005, or the > grant will no longer be valid. A Note Code will be placed on the grant to > this effect. Alternatively, a new test, over the required frequency range, > may be performed now, with data submitted, so that the grant will remain > valid indefinitely, and no such condition will appear on the grant. Please > indicate the choice of the applicant in this matter. > > Have a good evening, > > Marianne > Marianne T. Bosley > EMC Administrator > 410-354-3300 X 412 > [email protected] >

Test Report

Matsushita Kotobuki Electronics Industries Ltd. Storage Products Business Unit Address: 2131-1 Minamigata, Kawauchi-cho, Onsen, Ehime 791 – 0395 Japan Page 1 of 18 pages TEST REPORT REPORT NUMBER: MKM02F-003 APPLICANT: Matsushita Kotobuki Electronics Industries, Ltd. MODEL NUMBER: LKM-SD21-S FCC ID: IUO9TB095DSS Regulation: FCC Part15B Class B Conducted Emission Test Radiated Emission Test Matsushita Kotobuki Electronics Ind., Ltd. Storage Products Business Unit 2131-1 Minamigata, Kawauchi-cho, Onsen-gun, Ehime-ken, 791-0395 Japan Tel.: +81 89 966 2111 Fax.: +81 89 966 5733 Report No. MKM02F-003 FCC ID : IUO9TB095DSS Page 2 of 18 pages TABLE OF CONTENTS Page SECTION 1.TEST CERTIFICATION3 SECTION 2.EQUIPMENT UNDER TEST5 SECTION 3.SUPPORT EQUIPMENT USED6 SECTION 4.CABLE(S) USED 7 SECTION 5.CONSTRUCTION OF EQUIPMENT 9 SECTION 6.OPERATING CONDITIONS10 SECTION 7.TEST PROCEDURE(S) 11 SECTION 8.EVALUATION OF TEST RESULTS12 SECTION 9.PHOTOGRAPHS OF TEST SET-UP 16 SECTION 10. INSTRUMENTS USED FOR TEST17 SECTION 11. PRECISION18 SECTION 12. VALIDITY OF TEST REPORT18 Report No. MKM02F-003 FCC ID : IUO9TB095DSS Page 3 of 18 pages SECTION 1. TEST CERTIFICATION APPLICANT INFORMATION Company: Matsushita Kotobuki Electronics Industries, Ltd. Address: 2131-1 Minamigata, Kawauchi-cho, Onsen-gun, Ehime-ken, 791-0395 Japan GRANTEE INFORMATION Company: Matsushita Kotobuki Electronics Industries, Ltd. Division / Section : Storage Products Business Unit Legal Affairs Team. Address: 2131-1 Minamigata, Kawauchi-cho, Onsen-gun, Ehime-ken, 791-0395 Japan Telephone number: +81 89 966 2111 Fax number : +81 89 966 5733 Contact person: Shinji Yamauchi DESCRIPTION OF TEST ITEM Kind of equipment: DDS BUCKUP LIBRARY Trademark: Matsushita Kotobuki FCC ID : IUO9TB095DSS Model number : LKM-SD21-S Serial number: AA261000M00010 Report No. MKM02F-003 FCC ID : IUO9TB095DSS Page 4 of 18 pages TEST PERFORMED FCC Registration No.: 90793 Test started : September 17, 2002 Test completed: September 17, 2002 Purpose of test : FCC Docket 87-389 Regulation: FCC Part 15B Class B Unintentional Radiators Test setup: ANSI C63.4 -1992 Report file number: MKM02F-003 Report issue date: September 18, 2002 Test engineer: Shinji Yamauchi Report approved by : Hisayuki Honda [ Manager ] This equipment complies with above standard or regulation under the test condition or test configuration shown on this test report. Report No. MKM02F-003 FCC ID : IUO9TB095DSS Page 5 of 18 pages SECTION 2. EQUIPMENT UNDER TEST The equipment under test (EUT) consists of the following equipment. Indication in the following left side column corresponds to section 5. SymbolItemModel No. Serial No. FCC IDManufacturer A) DDS BUCKUP LKM-SD21-S AA261000M00010 IUO9TB095DSS Matsushita Kotobuki LIBRARY Electronics Ind., Ltd. Power ratings of EUT : AC 120V-240V,50Hz/60Hz, 0.5A-0.28A 2.1 Port(s) / Connector(s) : SCSI Half pitch Connector (68pin) SCSI Half pitch Connector (68pin) 2.2 Oscillator(s) / Crystal(s) : Oscillator OperatingBoard name Remarks Frequency 30 MHz 15 MHzMain PCBCPU 30 MHz 30 MHzMain PCBGate Array Highest frequency 30 MHz 15 MHz Buffer PCBCPU 30 MHz 30 MHz Buffer PCB Gate Array Highest frequency Report No. MKM02F-003 FCC ID : IUO9TB095DSS Page 6 of 18 pages SECTION 3. SUPPORT EQUIPMENT USED The EUT has been supported by the following equipment during these tests. Indication in the following left side column corresponds to section 5. SymbolItemModel No. Serial No.FCC IDManufacturer B) Interface CardREX-PCI34 None None RATOC C) Host Computer OptiPlex GXa SP4BX Declaration ofDELL DCS Conformity D) Color Display XC-1429C 009133290 BGB9J5XC-1429C MITSUBISHI E) Printer 3630A 3040A00351BSD8533630AHEWLETT PACKARD F) KeyboardSK-1000REW M980266463GYUR36SKDELL G) Mouse Mouse Port 01171231C3KKMP3 Microsoft CompatibleMouse2.1A H) DAT Data LKM-DD4G-7 260327 None Matsushita Storage DriveKotobuki Report No. MKM02F-003 FCC ID : IUO9TB095DSS Page 7 of 18 pages SECTION 4. CABLE(S) USED The following cable(s) was used for testing. Indication number in the following left side column corresponds to section 5. NumberNameLengthShield From To 1)SCSI cable 0.9 mYes Interface Card DDS BUCKUP Metal connector LIBRARY 2)SCSI cable 0.9 mYes DDS BUCKUP LIBRARY DAT Data Storage Metal connector Drive 3)Parallel I/F cable 1.5 mYes Host Computer Printer Metal connector 4)Keyboard I/F cable 1.9 mYes Host Computer Keyboard Metal connector 5)Mouse cable 1.9 mNone Host Computer Mouse Metal connector 6)Video Signal1.4 mYes Host Computer Color Display cable Metal connector 7) Power cord for 1.3 m None EUT Power Source EUT 8) Power cord for 1.3 m None DAT Data Storage Power Source DAT Data Storage Drive Drive 9) Power cord for 1.3 m None Host Computer Power Source Host Computer Report No. MKM02F-003 FCC ID : IUO9TB095DSS Page 8 of 18 pages The following cable(s) was used for testing. Indication number in the following left side column corresponds to section 5. NumberNameLengthShieldFromTo 10) Power cord for 1.5 m None Color Display Power Source Color Display 11)Power cord for Printer2.0 mNonePrinterAC Adapter 12)Power cord for Printer2.0 mNoneAC AdapterPower Source Report No. MKM02F-003 FCC ID : IUO9TB095DSS Page 9 of 18 pages SECTION 5. CONSTRUCTION OF EQUIPMENT The construction of EUT during testing is as follows. System configuration * : EUT D ) Color Display H) DAT Data E) Printer B) Interface Card A) DDS BUCKUP Storage LIBRARY Drive C ) Host Computer F) Keyboard 120V AC 120V AC 120V AC 120V AC 60Hz 60Hz 60Hz 60Hz Symbol or numbers assigned to equipment or cables on this diagram are corresponded to the symbols or numbers assigned to equipment or cables on tables in Sections 2 to 4. G)Mouse * 20V AC60Hz AC Adapter 12 3 4 5 6 78 9 10 11 12 120V AC 60Hz Report No. MKM02F-003 FCC ID : IUO9TB095DSS Page 10 of 18 pages SECTION 6. OPERATING CONDITIONS The EUT has been operated under the following conditions during the tests. 6.1 Operating condition The tests have been carried out under Read mode. 6.2 Operat…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No. MKM02F-003 FCC ID : IUO9TB095DSS Page 16 of 18 pages SECTION 9. PHOTOGRAPHS OF TEST SET-UP Test setup in accordance with ANSI C63.4-1992 9.1 Conducted Emission Test Front View Rear view 9.2 Radiated Emission Test Front View Rear view Note : Maintaining 10cm spacing between all the equipment cabinets.

Contact Information

Applicant

Shinji Yamauchi(Legal Affairs Team)
[email protected]81 89 966-1620Fax: 81 89 966-1637

Technical Contact

MET Laboratories, Inc.Chris Harvey
[email protected]410-354-3300

914 W. Patapsco Avenue Β· Baltimore, Maryland Β· United States

Non-Technical Contact

MET Laboratories, Inc.Marianne Bosley
[email protected]410-354-3300

Test Firm

Akzo Nobel K.K.Shuichi Kobayashi
[email protected]+81 479 40 1097Fax: +81 479 46 1788

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--

Other Applications from Panasonic Healthcare Co., Ltd.

DDS Backup Library - FCC ID IUO9TB099DSS - Panasonic Healthcare Co., Ltd.
IUO9TB099DSS

DDS Backup Library

Feb 23, 2004

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
IUO9TB098DSS

S-AIT Tape Drive Unit

Aug 09, 2003

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
IUO9TB097DSS

S-AIT Tape Drive Unit

Aug 09, 2003

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
DVD-ROM Drive - FCC ID IUO9TB096CRB - Panasonic Healthcare Co., Ltd.
IUO9TB096CRB

DVD-ROM Drive

Mar 31, 2003

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
IUO9TB094CRB

DVD-ROM & CD-R/RW Drive

Feb 21, 2002

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral