  3. IXLATA1

IXLATA1Tag Transponder

Deister Electronic GmbH
Tag Transponder - FCC ID IXLATA1 - Deister Electronic GmbH
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Apr 26, 2020
Application Purpose
Original Equipment
Date of Application
Apr 23, 2020
Equipment Note
Tag Transponder
Frequency Range
916.20000000 - 920.80000000
Company
Deister Electronic GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

UTA 1•UTA 2•UTA 3 ATA 1•PSA 1•ITA 3•PSA 3 Installation Instructions Installationshinweise Instructions d'Installation V190528 #896359 www.deister.com 5. Industry Canada This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. 6. Disclaimer deister electronic GmbH is not able to supervise the observance of the instructions given in this manual as well as the conditions and methods used during installation, operation and maintenance of the electronic devices and components respectively. Therefore we disclaim liability and reject responsibility for any losses, damages or costs that are caused by misapplication, installation, handling errors or faulty operation or related to the above in any other way. All our products are subject to current advancement, therefore we reserve the right for modifications without prior notice. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of deister electronic GmbH. deister electronic GmbH reserves the right to make changes to any and all parts of this documentation without obligation to notify any person or entity of such changes. deister electronic GmbH Hermann-Bahlsen Str. 11 30890 Barsinghausen Germany Phone: +49 (0) 51 05 - 51 61 11 Fax: +49 (0) 51 05 - 51 62 17 E-Mail: [email protected] Web: www.deister.com 7. Warranty Note • Garantiehinweis • Remarque garantie Bei nicht sachgemäßer Benutzung des Gerätes erlischt die Garantie! • Improper use of the device will void the warranty! • L‘utilisation incorrecte de l‘appareil annule la garantie! 2. Regulatory notices for Europe: Hereby, deister electronic declares that the radio equipment type UTA 1 / UTA 2 / UTA 3 / ATA 1 / PSA 1 / ITA 3 / PSA 3 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://go.deister.com/ce 2. Zulassungen für Europa: Hiermit erklärt deister electronic, dass der Funkanlagentyp UTA 1 / UTA 2 / UTA 3 / ATA 1 / PSA 1 / ITA 3 / PSA 3 der Richtlinie 2014/53/EU entspricht. Der vollständige Text der EU-Konformitätserklärung ist unter der folgenden Internetadresse verfügbar: http://go.deister.com/ce 2. Avis Réglementation Europe: Le soussigné, deister electronic, déclare que l'équipement radioélectrique du type UTA 1 / UTA 2 / UTA 3 / ATA 1 / PSA 1 / ITA 3 / PSA 3 est conforme à la directive 2014/53/UE. Le texte complet de la déclaration UE de conformité est disponible à l'adresse internet suivante: http://go.deister.com/ce 3. FCC Digital Device Limitations Radio and Television Interference This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reason- able protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or un- shielded cables is likely to result in interference to radio and television reception. Caution! Changes or modifications not expressly approved by the manufacturer could void the user ́s authority to operate this equipment. 4. FCC Notice To comply with FCC Part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as co-located antennas transmitting the same information) is expressly forbidden. Germany: deister electronic GmbH Hermann-Bahlsen-Str. 11 30890 Barsinghausen Tel.: +49 (0) 51 05 - 51 61 11 Fax: +49 (0) 51 05 - 51 62 17 [email protected] Americas and Caribbean: deister electronics USA, Inc. 9817 Godwin Drive #201 Manassas, VA 20110 Tel.: +1 703 - 368 2739 Fax: +1 703 - 368 9791 [email protected] Great Britain: deister electronic (UK) Ltd. Stapleton Way, Enterprise Park Spalding, Lincolnshire PE11 3YQ Tel.: +44 (0) 1775 - 717100 Fax: +44 (0) 1775 - 717101 [email protected] Benelux: deister electronic office Hendrik van Veldekesingel 150/56 OffiCenter 3500 Hasselt, Belgium Tel.: +32 (0) 15 – 48 02 15 Fax: +32 (0) 15 – 48 02 16 [email protected] France: deister electronic france 29, rue Jean Rostand Parc Club Orsay Université 91400 ORSAY Tel.: +33 (0) 1 47 – 35 78 78 Fax: +33 (0) 1 47 – 35 92 59 [email protected] Japan: Deister Service Co., Ltd. Room 812, MG Meguro…

Text truncated - open the document above for the full version.

Users Manual

For more information and your nearest point of contact, please refer to www.amantag.com Technical data are subject to change without notice at any time. The product conforms to CE rules. All rights reserved. © Copyright by deister electronic. ata-1_manual_en_896379_v200421.docx ATA 1 tag quick start guide Also applies to: BTA1, PSA1, UTA1,UTA2,UTA3 1 Package contents  amanTag ATA 1 tag  Quick start guide 2 Tag installation The tag must be installed by a trained amanTag system administrator. The tag will be automatically added to the database of a pc-based system when installed within range of an amanTag receiver. 3 Using the Tag The tag can be attached as follows:  On a keyring  As an amulet Once properly installed the Tag functions automatically providing the system with activate/response data to locate its position. The user or equipment need do nothing else; just carry the Tag with the item or person to be position located. 4 Illustration Regulatory notices for Europe Hereby, deister electronic declares that the radio equip- ment type ITA 3 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:https://go.deister.com/ce

Cover Letter(s)

Deister Electronics USA, Inc. 9817 Godwin Drive #201 Manassas, VA 20110 Direct Line: +1-703-659-9497 Direct FAX: +1-415-762-1963 Email: [email protected] www.deister.com 30 April 2019 To Whom It May Concern: We hereby delegate CKC Certification Services, LLC (CKC CS) power of attorney to act on our behalf in matters pertaining to certification of products. The actions of CKC CS shall be considered the same as our own. Sincerely, William L Nuffer President Deister Electronics USA, Inc. 9817 Godwin Drive #201 Manassas, VA 20110 1.703.368.2739

Cover Letter(s)

Deister Electronics USA, Inc. 9817 Godwin Drive #201 Manassas, VA 20110 Direct Line: +1-703-659-9497 Direct FAX: +1-415-762-1963 Email: [email protected] www.deister.com 4 June 2019 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Subject: Request for Permanent Confidentiality To whom it may concern: In accordance with 47CFR Section 0.457 and Section 0.459 pertaining to confidential material, we hereby request to hold permanently confidential all information contained within the below identified exhibits/document categories submitted pursuant to radio equipment certification requirements for FCC ID: IXLATA1 1. Block Diagram 2. Operational Description 3. Schematics 4. Parts List The above material contains trade secrets and proprietary information as specified by 47CFR 0.457(d) and technical data, which would customarily be guarded from competitors. The public disclosure of this information might be harmful to our company and provide unjustified benefits to our competitors. Sincerely, William L Nuffer President Deister Electronics USA, Inc. 9817 Godwin Drive #201 Manassas, VA 20110 1.703.368.2739

External Photos

F2P21410 Page 1 of 3 June 19, 2019 PHOTOGRAPHS: EXTERNAL Applicant - Deister Electronics USA, Inc. Model: ATA1 FCC ID: IXLATA1 Order Number: F2P21410 Applicant: Deister Electronics USA, Inc. Model: ATA1 F2P21410 Page 2 of 3 June 19, 2019 Order Number: F2P21410 Applicant: Deister Electronics USA, Inc. Model: ATA1 F2P21410 Page 3 of 3 June 19, 2019

Internal Photos

F2P21410 Page 1 of 6 June 19, 2019 PHOTOGRAPHS: INTERNAL Applicant - Deister Electronics USA, Inc. Model: ATA1 FCC ID: IXLATA1 Order Number: F2P21410 Applicant: Deister Electronics USA, Inc. Model: ATA1 F2P21410 Page 2 of 6 June 19, 2019 Order Number: F2P21410 Applicant: Deister Electronics USA, Inc. Model: ATA1 F2P21410 Page 3 of 6 June 19, 2019 Order Number: F2P21410 Applicant: Deister Electronics USA, Inc. Model: ATA1 F2P21410 Page 4 of 6 June 19, 2019 Order Number: F2P21410 Applicant: Deister Electronics USA, Inc. Model: ATA1 F2P21410 Page 5 of 6 June 19, 2019 Order Number: F2P21410 Applicant: Deister Electronics USA, Inc. Model: ATA1 F2P21410 Page 6 of 6 June 19, 2019

Test Report

060818 Report Number: F2P21410A-01E Page 1 of 24 Issue Date: June 17, 2019 F2 Labs 16740 Peters Road Middlefield, Ohio 44062 United States of America www.f2labs.com CERTIFICATION TEST REPORT Manufacturer: Deister Electronic GMBH 11 Hermann Bahlsen Str Barsinghausen 30890 GERMANY Applicant: Deister Electronics USA, Inc. 9817 Godwin Drive, #201 Manassas, Virginia 20110 USA Product Name: ATA1 Asset Transponder Product Description: amanTag asset location transponder for detection and communication of location vicinity of appropriate amanTag reader Operating Voltage/Frequency: Battery-Operated (3.3VDC) Model(s): ATA1* *Denotes actual model tested as representative of product family that includes the following: ATA1, BTA1, PSA1, UTA1, UTA2 and UTA3. FCC ID: IXLATA1 Testing Commenced: June 10, 2019 Testing Ended: June 10, 2019 Summary of Test Results: In Compliance The EUT complies with the EMC requirements when manufactured identically as the unit tested in this report, including any required modifications and/or manufacturer’s statement. Any changes to the design or build of this unit subsequent to this testing may deem it non-compliant. Standards:  FCC Part 15 Subpart C, Section 15.249  FCC Part 15 Subpart C, Section 15.215(c) – Additional provisions to the general radiated emission limitations  FCC Part 15 Subpart A, Section 15.31(e) – Measurement Standards Order Number: F2P21410A Applicant: Deister Electronics USA, Inc. Model: ATA1 060818 Report Number: F2P21410A-01E Page 2 of 24 Issue Date: June 17, 2019 Evaluation Conducted by: Julius Chiller, EMC/Wireless Engineer Report Reviewed by: Ken Littell, Director of EMC & Wireless Operations F2 Labs F2 Labs F2 Labs 26501 Ridge Road 16740 Peters Road 8583 Zionsville Road Damascus, MD 20872 Middlefield, OH 44062 Indianapolis, IN 46268 Ph 301.253.4500 Ph 440.632.5541 Ph 317.610.0611 This test report may be reproduced in full; partial reproduction only may be made with the written consent of F2 Labs. The results in this report apply only to the equipment tested. Order Number: F2P21410A Applicant: Deister Electronics USA, Inc. Model: ATA1 060818 Report Number: F2P21410A-01E Page 3 of 24 Issue Date: June 17, 2019 TABLE OF CONTENTS Section Title Page 1 ADMINISTRATIVE INFORMATION 4 2 SUMMARY OF TEST RESULTS/MODIFICATIONS 7 3 TABLE OF MEASURED RESULTS 8 4 ENGINEERING STATEMENT 9 5 EUT INFORMATION AND DATA 10 6 LIST OF MEASUREMENT INSTRUMENTATION 11 7 OCCUPIED BANDWIDTH 12 8 FIELD STRENGTH OF EMISSIONS/RADIATED SPURIOUS 15 9 PHOTOGRAPHS 23 Order Number: F2P21410A Applicant: Deister Electronics USA, Inc. Model: ATA1 060818 Report Number: F2P21410A-01E Page 4 of 24 Issue Date: June 17, 2019 1 ADMINISTRATIVE INFORMATION 1.1 Measurement Location: F2 Labs in Middlefield, Ohio. Site description and attenuation data are on file with the FCC's Sampling and Measurement Branch at the FCC Laboratory in Columbia, MD. 1.2 Measurement Procedure: All measurements were performed according to the 2013 version of ANSI C63.10 and recommended FCC procedure of measurement of DXT operating under Section 15.249. A list of the measurement equipment can be found in Section 6. Order Number: F2P21410A Applicant: Deister Electronics USA, Inc. Model: ATA1 060818 Report Number: F2P21410A-01E Page 5 of 24 Issue Date: June 17, 2019 1.3 Uncertainty Budget: The uncertainty in EMC measurements arises from several factors which affect the results, some associated with environmental conditions in the measurement room, the test equipment being used, and the measurement techniques adopted. The measurement uncertainty budgets detailed below are calculated from the test and calibration data and are expressed with a 95% confidence factor using a coverage factor of k=2. The Uncertainty for a laboratory are referred to as Ulab. For Radiated and Conducted Emissions, the Expanded Uncertainty is compared to the Ucispr values to determine if a specific margin is required to deem compliance. Ulab Ucispr If Ulab is less than or equal to Ucispr, then: • compliance is deemed to occur if no measured disturbance exceeds the disturbance limit; • non-compliance is deemed to occur if any measured disturbance exceeds the disturbance limit. If Ulab is greater than Ucispr in table 1, then: • compliance is deemed to occur if no measured disturbance, increased by (Ulab – Ucispr), exceeds the disturbance limit; • non-compliance is deemed to occur if any measured disturbance, increased by (Ulab – Ucispr), exceeds the disturbance limit. Note: Only measurements listed in the tables above that relate to tests included in this Test Report are applicable. Measurement Range Combined Uncertainty Expanded Uncertainty Radiated Emissions <1 GHz @ 3m 2.54 5.07dB Radiated Emissions <1 GHz @ 10m 2.55 5.09dB Radiated Emissions 1 GHz to 2.7 GHz 1.81 3.62dB Radiated Emissions 2.7 GHz to 18 GHz 1.55 3.10dB AC Power Line Conducted Emissions, 150kHz to 30 MHz 1.38 2.76dB AC Power Line Conducted Emissions, 9kHz to 150kHz 1.66 3.32dB Measurement Range Expanded Uncertainty Radiated Emissions <1 GHz @ 3m 5.2dB Radiated Emissions <1 GHz @ 10m 5.2dB Radiated Emissions 1 GHz to 2.7 GHz Under Consideration Radiated Emissions 2.7 GHz to 18 GHz Under Consideration AC Power Line Conducted Emissions, 150kHz to 30 MHz 3.6dB AC Power Line Conducted Emissions, 9kHz to 150kHz 4.0dB Order Number: F2P21410A Applicant: Deister Electronics USA, Inc. Model: ATA1 060818 Report Number: F2P21410A-01E Page 6 of 24 Issue Date: June 17, 2019 1.4 Document History: Document Number Description Issue Date Approved By F2P21410A-01E First Issue June 17, 2019 K. Littell Order Number: F2P21410A Applicant: Deister Electronics USA, Inc. Model: ATA1 060818 Report Number: F2P21410A-01E Page 7 of 24 Issue Date: June 17, 2019 2 SUMMARY OF TEST RESULTS Test Name Standard(s) Results -20dB Occupied Bandwidth CFR 47 Part 15.215(c) Complies Field Strength of Emissions CFR 47 Part 15.249(a)(d) Complies Conducted Emissions CFR 47 Part 15.207(a) N/A Variation of the Input Power CF…

Text truncated - open the document above for the full version.

Test Setup Photos

F2P21410 Page 1 of 2 June 19, 2019 PHOTOGRAPHS: TEST SETUP Applicant - Deister Electronics USA, Inc. Model: ATA1 FCC ID: IXLATA1 Occupied Bandwidth, Field Strength of Emissions Radiated Spurious, Less Than 30 MHz Order Number: F2P21410 Applicant: Deister Electronics USA, Inc. Model: ATA1 F2P21410 Page 2 of 2 June 19, 2019 Radiated Spurious, 30 MHz to 1000 MHz Radiated Spurious, Greater than 1 GHz

Contact Information

Applicant

Nicolas Stobbe(Head of Business Development)
[email protected]49-0-5105-516Fax: 49-0-5105-5162 66

Technical Contact

Deister Electronic GmbHStefan Moller
[email protected]+49.5105.516.111

11 Hermann Bahlsen Str · Barsinghausen · Germany

Non-Technical Contact

Deister Electronics USA, Inc.William Nuffer
[email protected]+1.703.368.2739

Test Firm

F2 LabsWendy Fuster
[email protected]301-253-4500Fax: 301-253-5179

Technical Specifications

#Rule PartsFrequency RangePower Output
115C916.2 MHz - 920.8 MHz-
Confidentiality
Long Term

Other Applications from Deister Electronic GmbH

RFID Reader - FCC ID IXLPRT6KPT6 - Deister Electronic GmbH
IXLPRT6KPT6

RFID Reader

Oct 07, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RFID Reader - FCC ID IXLSWH6000PCB - Deister Electronic GmbH
IXLSWH6000PCB

RFID Reader

Oct 07, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
IXLPRDI4IC

Access Control Reader Module

Nov 01, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Door Lock LF Read Head - FCC ID IXLRHX - Deister Electronic GmbH
IXLRHX

Door Lock LF Read Head

Aug 05, 2020

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Personal Tag Transponder - FCC ID IXLPSA3 - Deister Electronic GmbH
IXLPSA3

Personal Tag Transponder

Apr 26, 2020

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified