FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Deister Electronic GmbH/
  3. IXLMODEL245

IXLMODEL245Proximity Reader

Deister Electronic GmbH
Proximity Reader - FCC ID IXLMODEL245 - Deister Electronic GmbH
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Feb 12, 2003
Application Purpose
Original Equipment
Date of Application
Feb 12, 2003
Equipment Note
Proximity Reader
Frequency Range
15.56000000 - 15.56000000
Company
Deister Electronic GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

GEContactless SmartCardReader Model240and245 InstallationGuide 791 Park of Commerce Boulevard Suite 100 Boca Raton, Florida 33487 (561) 998-6100 Part Number: 460563001B January 2003 This document contains proprietary information of General ElectricCompany, USA and is furnished to its customer solely to assist thatcustomer in the installation, testing, operation, and/or maintenance ofthe equipment described. This document shall not be reproduced inwhole or in part nor shall its contents be disclosed to any third partywithout the written approval of GE Industrial Systems.GE PROVIDES THE FOLLOWING DOCUMENT AND THEINFORMATION INCLUDED THEREIN AS IS AND WITHOUTWARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDINGBUT NOT LIMITED TO ANY IMPLIED STATUTORY WARRANTYOF MERCHANTABILITY OR FITNESS FOR PARTICULARPURPOSE.This publication may contain examples of screen captures an dreportsused in daily operations. Examples include fictitious names of individualsan dcompanies. Any similarity to names an da d dresses of actualbusiness enterprises an dpersons is entirely coinci dental.Copyright 2003 GE Interlogix, CASIAll rights reserved.Printe din the U.S.AThe Model 240 and 245 Smart Card Readers are trademarks of GEInterlogix-CASI Division.MIFARE ® is a registered trademark of Philips Electronics, N.V. WARNINGThis is a Class A product. In a domestic environment, this productmay cause radio interference, in which case, the user may be requiredto take adequate measures. GE Contactless Smart Card Reader Model 24x i ContentsIntroduction ....................................................................................................... 1Product Overview ............................................................................................. 5 Features ................................................................................................. 5Access Control System Compatibility .............................................. 5 Installation.......................................................................................................... 7 Installation Considerations ................................................................ 8Micro Compatibility ............................................................................ 9Reader-to-Micro Wiring Distance ..................................................... 9Keypad Operation: Model 245 ........................................................... 9Wiring.................................................................................................. 10Point-to-Point Wiring Diagrams...................................................... 12 Troubleshooting .............................................................................................. 19Technical Specifications ................................................................................. 22Regulatory Notices.......................................................................................... 23 ii GEContactlessSmartCardReaderModel24x FiguresFigure 1: GE Contactless Smart Card Reader Model 240 ............ 1Figure 2: GE Contactless Smart Card Reader Model 245 ............ 2Figure 3: GE Model 24x Reader Backplate (includes tamper switch magnet) ................................... 3 Figure 4: Isolation Spacer ............................................................. 4Figure 5: GE Model 24x Backplate and Snap-on cover ................ 7Figure 6: Back-to-Back/Center-to-Center Installation.................... 8Figure 7: GE Model 24x Reader Wiring Diagram to Micro/5 8RP ................................................................. 12 Figure 8: Model 24x Smart Card Reader Wiring Diagram to J-Box........................................................................ 13 Figure 9: GE Model 24x Reader to 2RP...................................... 14Figure 10: GE Model 24x Reader to 8RP...................................... 16Figure 11: GE Model 240x Reader to Micro.................................. 18Figure 12: Stripping of Shield Grounds ......................................... 23 GE Contactless Smart Card Reader Model 24x 3 FIGURE 3: GE Model 24x Reader Backplate (includes tamper switch magnet)Note: Mounting holes fit standard US single-width electrical box andstandard European (EMEA) electrical box hole patterns.An Isolation Spacer (shown in Figure 4) may be used to improve the read-range distance when mounting to metal surfaces. Dimensions are thesame as the Reader Backplate. 4 GE Contactless Smart Card Reader Model 24x FIGURE 4: Isolation Spacer GE Contactless Smart Card Reader Model 24x 5 Product OverviewFeatures• Universal compatibility with all ISO 15963 and ISO 14443A credentials (badges, disc tags, and key fobs). • Supervised four-state (open, closed, wire cut, and wire short)monitoringfordoorcontacts,REX(requesttoexit). • Electrical protection (reverse polarity diode protection on powerlines). • Data lines; high-speed transient voltage suppressor diodes • Compatible with Micro/5 2RP and 8RP Reader Processor boards,Micro/PX-2000, and Micro/PXN-2000 controllers • IP 65-rated sealed electronics for deployment in both interior andexterior environments. • Integrated reader tamper protection and supervised datacommunications. • Reads the serial BID (badge ID) number of all ISO 15693 and ISO14443A credentials. • 12-button tactile membrane keypad (3 x 4 matrix) for PIN (personalidentification number) entry (Model 245 only). • RS-485 communications for reader firmware maintenance operations. Access Control System CompatibilityThe Model 24x badge reader outputs a 16-digit badge identification (BID)number. As a result, the Model 24x Smart Card Readers are compatiblewith Picture Perfect while microcontrollers on a Secure Perfect systemmust be field-configured for Model 24x compatibility.Picture Perfect Edition SetupRefer to Access/Badge Formats or to the Picture Perfect online help for assistance. A 16-digit BID format must be defined within Picture Perfect.Enter a suita…

Text truncated - open the document above for the full version.

Cover Letter(s)

deister electronic GmbH - Hermann-Bahlsen-Straße 11-13 D-30890 Barsinghausen ! IDENTIFIKATION PHOENIX TEST-LAB GmbH! SICHERHEITSTECHNIK Product Certification! VERKEHRSELEKTRONIK Königswinkel 10 ! 05105-516-01 32825 Blomberg " 05105-516217 29. Januar 2003 RE:Certification Application FCC ID:IXLModel245 Please be advised that the following information is to be held confidential and behalf of deister electronic GmbH, Hermann-Bahlsen-Strasse 11-13, 30890 Barsinghausen, Germany: - circuit diagrams - schematic (component) diagrams - block diagram - technical description of operation The application contains technical information which deister electronic GmbH deems to be trade secrets and proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention in this matter. (Stefan Eichler) deister electroinc GmbHHandelsregister :Bankverbindungen :Kto.-Nr.BLZ Hermann-Bahlsen-Straße 11-13Amtsger. Wennigsen HBR 1203Stadtsparkasse Barsinghausen05 304(251 512 70) 30890 BarsinghausenGeschäftsführung:Dresdner Bank Hannover76 142 02(250 800 20) ! (+49) 05105 516 01Anatoli StobbeDeutsche Bank Barsinghausen4 686 424(250 700 70) " (+49) 05105 516 217USt-IdNr. : DE 115507822Postgiro Hannover612 23-303 (250 100 30) Mitglied . BHE ®

External Photos

Annex B of test report R30013 Edition 2 EUT: Model 245 (PRA5) Manufacturer: deister electronic GmbH Examiner: Raimund BLASK Date of issue: 30 January 2003 page 1 of 2 30013eut1.jpg EUT, front view Annex B of test report R30013 Edition 2 EUT: Model 245 (PRA5) Manufacturer: deister electronic GmbH Examiner: Raimund BLASK Date of issue: 30 January 2003 page 2 of 2 30013eut3.jpg EUT, rear view

Internal Photos

Annex C of test report R30013 Edition 2 EUT: Model 245 (PRA5) Manufacturer: deister electronic GmbH Examiner: Raimund BLASK Date of issue: 30 January 2003 page 1 of 2 30013eut3.jpg EUT, inside view Annex C of test report R30013 Edition 2 EUT: Model 245 (PRA5) Manufacturer: deister electronic GmbH Examiner: Raimund BLASK Date of issue: 30 January 2003 page 2 of 2 30013eut2.jpg PCB, front view

Test Report

Königswinkel 10 32825 Blomberg Germany Phone +49 5235 9500-0 Fax +49 5235 9500-10 Test Report Reference: R30013 Edition 3 Equipment under Test: Model 245 (PRA5) Serial Number: - FCC ID: IXLMODEL245 Applicant: deister electronic GmbH Manufacturer: deister electronic GmbH Test Laboratory (CAB) accredited by DATech e.V. in compliance with DIN EN ISO/IEC 17025 under the Reg. No. TTI-P-G071/94-11 and listed by FCC 31040/SIT1300F2 TEST REPORT REFERENCE: R30013 Edition 3 Examiner: Raimund BLASK Date of issue: 07. February 2003 Page 2 of 29 Contents: Page 1 IDENTIFICATION .................................................................................................................................... 3 1.1 APPLICANT .................................................................................................................................... 3 1.2 MANUFACTURER.......................................................................................................................... 3 1.3 DATES ............................................................................................................................................ 3 1.4 TEST LABORATORY ..................................................................................................................... 4 1.5 RESERVATION .............................................................................................................................. 4 1.6 NORMATIVE REFERENCES......................................................................................................... 4 1.7 TEST RESULTS ............................................................................................................................. 4 2 TECHNICAL DATA OF EQUIPMENT .....................................................................................................5 2.1 DEVICE UNDER TEST .................................................................................................................. 5 2.2 PEREPHERY DEVICES ................................................................................................................. 5 3 OPERATIONAL STATES AND PHYSICAL BOUNDARIES .................................................................... 6 4 LIST OF TEST MODULES ...................................................................................................................... 7 4.1 EMISSION ...................................................................................................................................... 7 METHOD OF MEASUREMENT ................................................................................................................. 8 4.2 RADIATED EMISSIONS 9 kHz to 30 MHz ..................................................................................... 8 4.3 RADIATED EMISSIONS 30 MHz to 1 GHz .................................................................................... 10 4.4 FREQUENCY STABILITY WITH RESPECT TO AMBIENT TEMPERATURE AND SUPPLY VOLTAGE....................................................................................................................................... 12 5 TEST RESULTS EMISSION TEST ......................................................................................................... 14 5.1 PRELIMINARY RADIATED EMISSION TEST (9 kHz to 30 MHz) ................................................. 14 5.2 PRELIMINARY RADIATED EMISSION TEST (30 MHz to 1 GHz) ................................................ 17 5.3 FINAL RADIATED EMISSION TEST (9 kHz to 30 MHz) ............................................................... 20 5.4 FINAL RADIATED EMISSION TEST (30 MHz to 1 GHz)............................................................... 21 5.5 OCCUPIED BANDWIDTH..............................................................................................................23 5.6 FREQUENCY TOLLERANCE ........................................................................................................ 24 6 TEST EQUIPMENT AND ANCILLARIES USED FOR TESTS ................................................................ 25 7 LIST OF ANNEXES ................................................................................................................................. 29 TEST REPORT REFERENCE: R30013 Edition 3 Examiner: Raimund BLASK Date of issue: 07. February 2003 Page 3 of 29 1 IDENTIFICATION 1.1 APPLICANT Name: deister electronic GmbH Address: Hermann-Bahlsen-Straße 11 – 13 30890 Barsinghausen Country: Germany Name for contact purposes: Mr. Stefan Eichler Phone: +49 51 05 516-129 Fax: +49 51 05 516-266 Mail address: [email protected] Applicant represented during the test by the following person: - 1.2 MANUFACTURER Name: deister electronic GmbH Address: Hermann-Bahlsen-Straße 11 – 13 30890 Barsinghausen Country: Germany Name for contact purposes: Mr. Stefan Eichler Phone: +49 51 05 516-129 Fax: +49 51 05 516-266 Mail address: [email protected] Manufacturer represented during the test by the following person: - 1.3 DATES Date of receipt of test sample: 17. January 2003 Start of test: 18. January 2003 End of test: 21. January 2003 TEST REPORT REFERENCE: R30013 Edition 3 Examiner: Raimund BLASK Date of issue: 07. February 2003 Page 4 of 29 1.4 TEST LABORATORY The tests were carried out at: PHOENIX TEST-LAB GmbH Königswinkel 10 D-32825 Blomberg Phone: +49 (0) 52 35 / 95 00-0 Germany Fax: +49 (0) 52 35 / 95 00-10 accredited by DATech e.V. in compliance with DIN EN ISO/IEC 17025 under Reg. No. TTI-P-G071/94-11. Test engineer: Raimund Blask 07.February. 2003 name signature date Test report checked: Bernd Steiner 10.February. 2003 name signature date stamp 1.5 RESERVATION This test report is only valid in its original form. Any reproduction of its contents without written permission of the accredited test laboratory PHOENIX TEST-LAB GmbH is prohibited. The test results herein refer only to the tested sample. PHOENIX TEST-LAB GmbH is not responsible for any general…

Text truncated - open the document above for the full version.

Test Setup Photos

Annex A of test report R30013 Edition 2 EUT: Model 245 (PRA5) Manufacturer: deister electronic GmbH Examiner: Raimund BLASK Date of issue: 30 January 2003 page 1 of 5 30013_6.jpg Test set-up preliminary emission measurement (9 kHz to 30 MHz) Annex A of test report R30013 Edition 2 EUT: Model 245 (PRA5) Manufacturer: deister electronic GmbH Examiner: Raimund BLASK Date of issue: 30 January 2003 page 2 of 5 20646_c.jpg test set-up preliminary emission measurement (30 MHz to 1 GHz) Annex A of test report R30013 Edition 2 EUT: Model 245 (PRA5) Manufacturer: deister electronic GmbH Examiner: Raimund BLASK Date of issue: 30 January 2003 page 3 of 5 30013_11.jpg Test set-up final emission measurement (9 kHz to 30 MHz) Annex A of test report R30013 Edition 2 EUT: Model 245 (PRA5) Manufacturer: deister electronic GmbH Examiner: Raimund BLASK Date of issue: 30 January 2003 page 4 of 5 30013_15.jpg Test set-up final emission measurement (30 MHz to 1 GHz) Annex A of test report R30013 Edition 2 EUT: Model 245 (PRA5) Manufacturer: deister electronic GmbH Examiner: Raimund BLASK Date of issue: 30 January 2003 page 5 of 5 30013_18.jpg Test set-up climatic chamber

Contact Information

Applicant

Nicolas Stobbe(Head of Business Development)
[email protected]49-0-5105-516Fax: 49-0-5105-5162 66

Technical Contact

deister electronic GmbHStefan Eichler
[email protected]+49-5105 516 01

Hermann-Bahlsen-Str. 11-13 · Barsinghausen · Germany

Non-Technical Contact

deister electronic GmbHStefan Eichler
[email protected]+49-5105 516 01

Test Firm

Phoenix TestLab GmbHH. Altmaier
[email protected]49-5235-9500-0Fax: 49-5235-9500-10

Technical Specifications

#Rule PartsFrequency RangePower OutputTolerance
115C15.56 MHz - 15.56 MHz-0.0100000000 %
Confidentiality
Long Term

Other Applications from Deister Electronic GmbH

RFID Reader - FCC ID IXLPRT6KPT6 - Deister Electronic GmbH
IXLPRT6KPT6

RFID Reader

Oct 07, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RFID Reader - FCC ID IXLSWH6000PCB - Deister Electronic GmbH
IXLSWH6000PCB

RFID Reader

Oct 07, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
IXLPRDI4IC

Access Control Reader Module

Nov 01, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Door Lock LF Read Head - FCC ID IXLRHX - Deister Electronic GmbH
IXLRHX

Door Lock LF Read Head

Aug 05, 2020

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Personal Tag Transponder - FCC ID IXLPSA3 - Deister Electronic GmbH
IXLPSA3

Personal Tag Transponder

Apr 26, 2020

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified