
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Septwember 2000 APREL Project No.:ITRB IX-250 ARDIS Consulting * Research * Training * Certification Testing Since 1981 Exhibit 9 Itronix IX-250 ITRONIX Corporation FCC ID: KBCIX250RIM802 User’s Manual 801 S. STEVENS STREET SPOKANE, WA 99204 509.624.6600 800.441.1309 FAX 509.626.4203 www.itronix.com September 26, 2000 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 In re:ITRONIX CORPORATION FCC ID: KBCIX250RIM802 FCC Part 90 Certification Gentlemen: The user manual for the Itronix laptop computer IX250 utilizing RIM 802 radio is not completed at this time. The RF warning statement will be supplied with all products marketed to our customers. We expect the manual to be competed with in the next 2 months. A copy will be supplied at that time if required by the FCC. Sincerely Fred Phillips Certification Engineer Itronix Corporation
77-0100-001 12 September 2000 GoBook Users Manual ii Identification GoBook (IX250) User’s Manual September 2000 · Revision 001 Copyright Notice © Copyright 2000 Itronix Corporation. All rights reserved. No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any other language or computer language in whole or in part, in any form or by any means, whether it be electronic, mechanical, magnetic, optical, manual, or otherwise, without the prior written consent of Itronix Corporation, South 801 Stevens Street, Spokane, Washington 99204. Disclaimer This document is printed in the U.S.A. Itronix Corporation reserves the right to revise the manual and make periodic changes to the content without a direct or inferred obligation to Itronix to notify any person of such revision or changes. Itronix Corporation does not assume responsibility for the use of this manual, nor for any patent infringements or other rights or third parties who may use the manual. This document contains valuable trade secrets and proprietary information of Itronix Corporation. This product is available for purchase under the terms of the Itronix Hardware Purchase and Software License Agreement. Itronix hardware products may be reconditioned, or be manufactured from parts and components that may be new, used, rebuilt, or recycled and in some cases, the hardware product may not be new and may have been previously installed. In any event, Itronix warranty terms apply. Trademark Notice Itronix is a registered trademark of Itronix Corporation. Microsoft, MS, Windows, and MS-DOS are registered trademarks of Microsoft Corporation. IBM is a trademark of International Business Machines Corporation. 77-0100-001 12 September 2000 iii Compliance Statements The GoBook (IX250) computer has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •Reorient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •Consult the dealer or an experienced radio/TV technician for help. The GoBook (IX250) computer complies with Part 68 of the FCC Rules. On the bottom of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone company. The REN is used to determine the quantity of devices which may be connected to the telephone line. Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determined by the total RENs, contact the telephone company to determine the maximum REN for the calling area. The GoBook (IX250) computer may be connected to the telephone network using the RJ-11 jack provided. 77-0100-001 12 September 2000 GoBook Users Manual iv If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice isn’t practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications in order to maintain uninterrupted service. If trouble is experienced with this equipment, please contact the equipment manufacturer for repair and/or warranty information. Do not attempt repairs of this equipment yourself without obtaining manufacturer authorized parts and documentation. If the trouble is causing harm to the telephone network, the telephone company may request you remove the equipment from the network until the problem is resolved. Compliance Statement for Canada NOTICE: The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user’s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own prot…
Text truncated - open the document above for the full version.
Septwember 2000 APREL Project No.:ITRB IX-250 ARDIS Consulting * Research * Training * Certification Testing Since 1981 Exhibit 1 Itronix IX-250 ITRONIX Corporation FCC ID: KBCIX250RIM802 Authorization letter Letter requesting Confidentiality Letter Authorizing use of the RIM R802D-2-0 radio- modem
Septwember 2000 APREL Project No.:ITRB IX-250 ARDIS Consulting * Research * Training * Certification Testing Since 1981 Exhibit 11 Itronix IX-250 ITRONIX Corporation FCC ID: KBCIX250RIM802 Declaration of Conformity
* Consulting * Research * Training * Certification Testing Since 1981 51 Spectrum Waytel: (613) 820-2730 Nepean, Ontariovisit our Web Pages: www.aprel.comfax: (613) 820-4161 Canada K2R 1E6email: [email protected] December 13, 2000 Federal Communications Commission Equipment Authorization Division Applications Processing Branch 7435 Oakland Mills Road Columbia, Maryland 21046 To: Errol [email protected] From: Jay [email protected] Subject: Information requested RE: FCC ID KBCIX250RIM802 Applicant: Itronix Corporation Correspondence 17362 731 Confirmation No.EA98870 Date of Original e-mail: December 12,2000 3:40 PM Dear Mr. Chang: Pursuant to your e-mail to me, dated December 12, 2000, I am forwarding to you our response. The relevant portion of the e-mail from FCC follows with our response inserted in the appropriate place. 1.Please identify exactly what you are seeking approval for. . Response: The approval is for the Rugged Laptop PC, IX-250 with a Research in Motion Transmitter, Ardis/DataTAC (built-in RIM 802D radio modem, FCC ID: L6AR802D-2-0) under Part 90 and 2. Equipment Class: Licensed Non-Broadcast Station Transmitter. Notes: Rugged Laptop PC with RIM 802 DataTAC Radio Modem. I trust that the above will answer your inquiry. If not, feel free to contact the undersigned. Thanking you in advance for your kind cooperation. Best regards, Jayanta (Jay) K. Sarkar Technical Director, Standards and Certification * Consulting * Research * Training * Certification Testing Since 1981 51 Spectrum Waytel: (613) 820-2730 Nepean, Ontariovisit our Web Pages: www.aprel.comfax: (613) 820-4161 Canada K2R 1E6email: [email protected]
Septwember 2000 APREL Project No.:ITRB IX-250 ARDIS Consulting * Research * Training * Certification Testing Since 1981 Table of Contents Wireless Laptop PC with a RIM R802D-2-0 radio-modem Itronix IX-250 FCC ID: KBCIX250RIM802 ITRONIX Corporation C C O O V V E E R R L L E E T T T T E E R R Exhibit 1: Authorization Letter and, Request for confidentiality Letter from RIM authorizing use of their modem Exhibit 2:Engineering Reports (Includes Test Set-up Photographs) Exhibit 3: Technical Descriptions and Tune-up Procedure Exhibit 4: FCC ID Label Exhibit 5:Photographs of the Equipment Internal and External Exhibit 6: Block Diagram (Confidential) Exhibit 7: Schematic Diagram (Confidential) Exhibit 8:Parts List (Confidential) Exhibit 9:User’s Manual Exhibit 10:SAR Report (Includes Test Set-up Photographs) Exhibit 11: FCC Part 15 Declaration of Conformance (DoC) certificate Exhibit 12: Additional Test Data for 2.1049, 2.1047, 2.1051 and 2.1055
Septwember 2000 APREL Project No.:ITRB IX-250 ARDIS Consulting * Research * Training * Certification Testing Since 1981 Exhibit 5 Itronix IX-250 ITRONIX Corporation FCC ID: KBCIX250RIM802 Photographs of the Equipment Internal External
Assessment of Compliance for Measurement of Effective Radiated Power (ERP) in accordance with the FCC Rules & Regulations Part 2.1046 IX-250 Laptop PC Intronix Corporation. 51 Spectrum Way Nepean ON K2R 1E6 Tel: (613) 820-2730 Fax: (613) 820-4161 email: [email protected] August 2000 ITRB-ITRONIX-IX-250-RIM 802D-2-0-3524
August 21,2000Page 14APREL Project No.: ITRB-IX-250- Rim 802D-2-0-3524 Consulting * Research * Training * Certification Testing Since 1981 Laptop PC – IX-250 R802 D-2-0
Assessment of Compliance for Measurement of Field Strength of Spurious Radiation in accordance with the FCC Rules & Regulations Part 2.1053 IX-250 Laptop PC Intronix Corporation. 51 Spectrum Way Nepean ON K2R 1E6 Tel: (613) 820-2730 Fax: (613) 820-4161 email: [email protected] August 2000 ITRB-ITRONIX-IX-250-ARDIS-3546
June 2000 Page 19 APREL Project No: ITRB IX-250 ARDIS-3546 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories Consulting * Research * Training * Certification Testing Since 1981 Spurious Emissions set up in OATS
Septwember 2000 APREL Project No.:ITRB IX-250 ARDIS Consulting * Research * Training * Certification Testing Since 1981 Exhibit 4 Itronix IX-250 ITRONIX Corporation FCC ID: KBCIX250RIM802 FCC ID Label
Septwember 2000 APREL Project No.:ITRB IX-250 ARDIS Consulting * Research * Training * Certification Testing Since 1981 Exhibit 10 Itronix IX-250 ITRONIX Corporation FCC ID: KBCIX250RIM802 SAR Report (With Test Set-up Photographs) This report shall not be reproduced, except in full, without the express written permission of APREL Laboratories 51 Spectrum Way Nepean ON K2R 1E6 Tel: (613) 820-2730 Fax: (613) 820-4161 email: [email protected] Certification Report on Specific Absorption Rate (SAR) Experimental Analysis Itronix Corporation IX-250 (DataTAC/Ardis) Mobile Computer with a Research In Motion R802D-2-O Radio Modem (DataTAC / Ardis network) Test Date: 21 July, 2000 ITRB-IX-250 DataTAC/Ardis-3503 A087-IX-250D Page 2 of 21Project #: ITRB-IX-250 DataTAC/Ardis-3503 51 Spectrum WayTel. (613) 820-2730 Nepean, Ontario, K2R 1E6 Fax (613) 820 4161 e-mail: [email protected] © APREL 2000 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories. FCC ID: KBCIX250RIM802 Applicant:Itronix Corporation Equipment:Mobile Computer with a Research In Motion R802D-2-O Radio Modem (DataTAC / Ardis network) Model:IX-250 (DataTAC/Ardis) Standard:FCC 96 –326, Guidelines for Evaluating the Environmental Effects of Radio- Frequency Radiation ENGINEERING SUMMARY This report contains the results of the engineering evaluation performed on an Itronix IX-250 mobile computer, operating with a built-in Research In Motion R802D-2-O DataTAC/Ardis radio modem. The measurements were carried out in accordance with FCC 96-326. The mobile computer was evaluated at its nominal maximum power level (2W / 33dBm). The duty factor of the production R802D-2-O modems will be controlled to be intrinsically restricted to 25% (see Appendix F). The Itronix IX-250 mobile computer was tested at low, middle and high channels and on the antenna, keyboard and bottom sides. The maximum 1g SAR (1.30 W/kg) was found to coincide with the peak performance RF output power of channel 24B0 (high, 821 MHz) for the antenna side of the device. Test data and graphs are presented in this report. Based on the test results and on how the device will be marketed and used, it is certified that the product meets the requirements as set forth in the above specifications, for an uncontrolled RF exposure environment. (The results presented in this report relate only to the sample tested.) Page 3 of 21Project #: ITRB-IX-250 DataTAC/Ardis-3503 51 Spectrum WayTel. (613) 820-2730 Nepean, Ontario, K2R 1E6 Fax (613) 820 4161 e-mail: [email protected] © APREL 2000 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories. TABLE OF CONTENTS 1.Introduction.....................................................................................................................4 2.Applicable Documents....................................................................................................4 3.Equipment Under Investigation......................................................................................4 4.Test Equipment...............................................................................................................5 5.Test Methodology...........................................................................................................5 6.Test Results.....................................................................................................................6 6.1.Transmitter Characteristics.............................................................................................6 6.2.SAR Measurements.........................................................................................................7 7.Conclusions.....................................................................................................................9 APPENDIX A. Measurement Setup and SAR Graphs............................................................10 APPENDIX B. Manufacturer’s Specifications........................................................................15 APPENDIX C. Uncertainty Budget.........................................................................................16 APPENDIX D. Simulated Muscle Tissue Material and Calibration Technique......................17 APPENDIX E. Validation Scans on a Flat Phantom...............................................................20 APPENDIX F. Duty Factor Limiting Algorithm for the OEM Radio Module R802D-2-O...21 TABLES AND FIGURES Table 1.SAR Measurements..........................................................................7 Table 2.Dielectric Properties of the Simulated Muscle Tissue at 815 MHz..................17 Table 3.Calculation of Dielectric Properties of the Simulated Muscle Tissue ...............18 Table 4.Calculation of the Tissue Conversion Factor of the Simulated Muscle Tissue .....19 Figure 1.Setup.........................................................................................................................10 Figure 2.Grid inside the Phantom...........................................................................................10 Figure 3.Contour Plot of the Area Scan 2.5mm Above Phantom Surface.............................11 Figure 4.Surface Plot of the Area Scan 2.5mm Above Phantom Surface..............................11 Figure 5.Contour Plot of the Area Scan 12.5mm Above Phantom Surface...........................12 Figure 6.Surface Plot of the Area Scan 12.5mm Above Phantom Surface............................12 Figure 7.Zoom Scan 2.5mm Above Phantom Surface...........................................................13 Figure 8.Zoom Scan 7.5mm Above Phantom Surface...........................................................13 Figure 9.Zoom Scan 12.5mm Above Phantom Surface.........................................................13 Figure 10.Overlay of the DUI’s Outlines Superimposed onto the Area Scan.........................14 Figure 11.Local SAR versus Sensor …
Text truncated - open the document above for the full version.
* Consulting * Research * Training * Certification Testing Since 1981 51 Spectrum Waytel: (613) 820-2730 Nepean, Ontariovisit our Web Pages: www.aprel.comfax: (613) 820-4161 Canada K2R 1E6email: [email protected] December 18, 2000 Federal Communications Commission Equipment Authorization Division Applications Processing Branch 7435 Oakland Mills Road Columbia, Maryland 21046 To: Errol [email protected] From: Jay [email protected] Subject: Information requested RE: FCC ID KBCIX250RIM802 Applicant: Itronix Corporation Correspondence 17383 731 Confirmation No.EA98870 Date of Original e-mail: December 13,2000 1:40 PM Dear Mr. Chang: Pursuant to your e-mail to me, dated December 13, 2000, I am forwarding to you our response. The relevant portion of the e-mail from FCC follows with our response inserted in the appropriate place. 1.The latest submitted manual info indicates there are vehicle-mount antenna configurations. This device operates with a Part 90 SMR radio and has indicated in the filing that the radio module will be limited to operate with a maximum duty factor of 25%. At 2 W conducted output, this provides an average output of 500 mW. In order for this transmitter to qualify for the categorical exclusion requirements of 2.1091, the antenna gain must be limited to satisfy a maximum averaged output of 1.5 W ERP; otherwise routine MPE evaluation is required. Please clarify and either provide the necessary information for users to satisfy MPE categorical exclusion requirements or provide MPE evaluation on specific antennas (if cannot qualify for exclusion). Note: you may also want to review the grant conditions on the RIM module to determine if any antenna RIM had tested may be used for this filing. Proposed Grant Conditions - Output is ERP. Device must operate with a duty factor not exceeding 25%, to be controlled by factory firmware. Device may operate with vehicle-mounted antennas that satisfy categorical exclusion requirements of 2.1091. Users and installers must be provided with the appropriate operating instructions, including vehicle-mount configurations, for satisfying RF exposure compliance. The highest report SAR value is 1.3 W/kg. * Consulting * Research * Training * Certification Testing Since 1981 51 Spectrum Waytel: (613) 820-2730 Nepean, Ontario visit our Web Pages: www.aprel.com fax: (613) 820-4161 Canada K2R 1E6email: [email protected] . Response: We have elected to provide you with MPE evaluation report on specific antenna: Vehicle-rooftop mounted unity gain ARDIS/CDPD antenna (See MPE report page 9). The MPE evaluation report is being uploaded with this response. Equipment Class: Licensed Non-Broadcast Station Transmitter. Notes: Rugged Laptop PC with RIM 802 DataTAC Radio Modem. I trust that the above will answer your inquiry. If not, feel free to contact the undersigned. Thanking you in advance for your kind cooperation. Best regards, Jayanta (Jay) K. Sarkar Technical Director, Standards and Certification
Assessment of Compliance for Measurement of Maximum Permissible Exposure Evaluation with Respect to FCC Rule Part 47CFR §2.1091 IX-250 Laptop PC Intronix Corporation. 51 Spectrum Way Nepean ON K2R 1E6 Tel: (613) 820-2730 Fax: (613) 820-4161 email: [email protected] August 2000 ITRB-ITRONIX-IX-250-ARDIS-3524 August 24, 2000 Page 2 APREL Project No.: ITRB-IX-250 RIM R802D-2-O-3524 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories Consulting * Research * Training * Certification Testing Since 1981 FCC ID:KBCIX250RIM802 Client :Itronix Corporation Equipment :Itronix IX-250 Wireless Laptop PC containing built in RIM R802D-2-O radio- modem, equipped with Vehicle Cradle and external vehicle-top mounting Unity Gain ARDIS/CDPD Antenna ENGINEERING SUMMARY This report contains the results of the maximum permissible exposure (MPE) evaluation performed on the device under investigation (DUI) which was comprised of an Itronix IX-250 Wireless Laptop PC containing built in Research in Motion R802D-2-O radio-modem, equipped with Vehicle Cradle and external vehicle-top mounting Unity Gain ARDIS/CDPD Antenna. The tests were carried out in accordance with the applicable requirements of FCC rules found in 47CFR §2.1091 and the standards ANSI/IEEE C95.1-1992 and C95.3-1992. The methodology and results for the test are described in the appropriate section of this report. The DUI will not exceed the MPE requirements for the 806.00 – 821.00 MHz band. The maximum power exposure level measured at 20 cm was 0.51 mW/cm 2 . The DUI was tested on frequency 806.00 MHz, at the low channel, which was the channel with the highest ERP. August 24, 2000 Page 3 APREL Project No.: ITRB-IX-250 RIM R802D-2-O-3524 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories Consulting * Research * Training * Certification Testing Since 1981 FCC SUBMISSION INFORMATION FCC ID:KBCIX250RIM802 Equipment:Wireless Laptop PC containing built in RIM R802D-2-O radio-modem, equipped with Vehicle Cradle and external vehicle-top mounting Unity Gain ARDIS/CDPD Antenna Model:Itronix IX-250 with a Research in Motion R802D-2-O transceiver For:Certification Applicant:ITRONIX Corporation 801 South Stevens Street Spokane, WA 99204 U.S.A. Manufacturer: ITRONIX Corporation 801 South Stevens Street Spokane, WA 99204 U.S.A. Evaluated by:APREL Inc. 51 Spectrum Way Nepean, Ontario Canada K2R 1E6 August 24, 2000 Page 4 APREL Project No.: ITRB-IX-250 RIM R802D-2-O-3524 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories Consulting * Research * Training * Certification Testing Since 1981 TABLE OF CONTENTS SECTIONTITLEPAGE ACRONYMS...................................................................................................5 1.0INTRODUCTION...........................................................................................6 1.1General...........................................................................................................6 1.2Scope.............................................................................................................6 1.3Schedule.........................................................................................................6 2.0APPLICABLE DOCUMENTS...........................................................................6 3.0TEST SAMPLE ..............................................................................................7 4.0GENERAL REQUIREMENTS...........................................................................7 4.1Location of Test Facilities.................................................................................7 4.2Personnel........................................................................................................7 4.3Failure Criteria.................................................................................................7 4.4Power Source Required....................................................................................8 4.5Tolerances......................................................................................................8 5.0TEST INSTRUMENTATION...........................................................................8 5.1General...........................................................................................................8 5.2MPE Test Equipment Required..........................................................................8 5.3Calibration Requirements..................................................................................8 6.0ELECTRICAL/MECHANICAL DESCRIPTION..................................................9 6.1Test Unit Description.......................................................................................9 6.2MPE Test Setup..............................................................................................9 7.0MAXIMUM PERMISSIBLE EXPOSURE (MPE) TEST PLAN...........................12 7.1Purpose........................................................................................................12 7.2Test Equipment.............................................................................................12 7.3Criteria.........................................................................................................12 7.4Test Procedure..............................................................................................14 7.5Results.........................................................................................................15 8.0CONCLUSION..............................................................................................18 APPENDIXEquipment List..............................................................................................19 August 24, 2000 Page 5 APREL Project No.: ITRB-IX-250 RIM R802D-2-O-3524 This report shall not be reproduced, except in full, w…
Text truncated - open the document above for the full version.
Septwember 2000 APREL Project No.:ITRB IX-250 ARDIS Consulting * Research * Training * Certification Testing Since 1981 Exhibit 2 Itronix IX-250 ITRONIX Corporation FCC ID: KBCIX250RIM802 Engineering Reports ERP and Spurious (With Test Set-up Photographs) Assessment of Compliance for Measurement of Effective Radiated Power (ERP) in accordance with the FCC Rules & Regulations Part 2.1046 IX-250 Laptop PC Intronix Corporation. 51 Spectrum Way Nepean ON K2R 1E6 Tel: (613) 820-2730 Fax: (613) 820-4161 email: [email protected] August 2000 ITRB-ITRONIX-IX-250-RIM 802D-2-0-3524 August 21,2000Page 2APREL Project No.: ITRB-IX-250- Rim 802D-2-0-3524 Consulting * Research * Training * Certification Testing Since 1981 FCC ID:KBCIX250RIM802 Applicant:Itronix Corporation Equipment:Laptop PC Model:IX-250 with a Research in Motion R802D-2-0 transmitter Standard:FCC Rules and Regulations Part 2.1046 ENGINEERING SUMMARY This report contains the results of the effective radiated power (ERP) measurement performed on an Itronix IX-250 Laptop PC operating with a built-in Research in Motion R802D-2-0 Datatac radio transmitter. The measurements were carried out in accordance with the FCC Rules and Regulations Part 2.1046. The handheld PC was evaluated for ERP when it was set at the maximum power level of. The Datatac version of the IX-250 was tested for ERP at high, middle, and low frequencies with the maximum ERP obtained at high channel (No. 2000) with the frequency being 806.00 MHz. The test data is presented in this report under the section: Test Results. August 21,2000Page 3APREL Project No.: ITRB-IX-250- Rim 802D-2-0-3524 Consulting * Research * Training * Certification Testing Since 1981 Summary of the Results Test DescriptionPage No. Test Set-up Figure No. Results Summary RF Power Output as Radiated Ref. Paragraph 2.104671Passed August 21,2000Page 4APREL Project No.: ITRB-IX-250- Rim 802D-2-0-3524 Consulting * Research * Training * Certification Testing Since 1981 FCC SUBMISSION INFORMATION FCC ID:KBCIX250RIM802 Electronic Serial Number:N/A Equipment:Laptop PC Model:IX-250 with a Research in Motion R802D-2-0 transmitter For:Certification Applicant:Itronix Corporation 801 South Stevens Street Spokane, WA 99204 U.S.A. Manufacturer: Itronix Corporation 801 South Stevens Street Spokane, WA 99204 U.S.A. Evaluated by:APREL Laboratories 51 Spectrum Way Nepean, Ontario Canada K2R 1E6 August 21,2000Page 5APREL Project No.: ITRB-IX-250- Rim 802D-2-0-3524 Consulting * Research * Training * Certification Testing Since 1981 INTRODUCTION General This report describes the results of the effective radiated power (ERP) measurement conducted on an Itronix IX-250 Laptop PC operating with a built in Research in Motion R802D-2-0 Datatac radio transmitter. Test Facility The tests were performed for Itronix Corporation by APREL Laboratories at APREL’s EMI facility located in Nepean, Ontario, Canada. The laboratory operates an (3m and 10m) Open Area Test Site (OATS). The measurement facility is calibrated in accordance with ANSI C63.4-1992. A description of the measurement facility in accordance with the radiated and AC line conducted test site criteria per ANSI C63.4-1992 is on file with the Federal Communications Commission and is in compliance with the requirements of Section 2.948 of the Commissions rules and regulations. APREL’s registration number is 90416 APREL is accredited by Standard Council of Canada, under NAPTO program (ISO Guide 25). APREL is als…
Text truncated - open the document above for the full version.
51 Spectrum Way · Nepean, Ontario · Canada
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 90 | 806 MHz - 821 MHz | 2.04 W | 20K0F1D | 2.5000000000 ppm |

IX-BTBR51
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
IX-MC8775
Equipment Class
PCB - PCS Licensed Transmitter
IX-4965AGN
Equipment Class
NII - Unlicensed National Information Infrastructure TX
IX-AC595 DUAL-BAND CDMA/EV-DO PCMCIA MODEM CARD
Equipment Class
PCB - PCS Licensed Transmitter
IX-NW620 CDMA/EV-DO
Equipment Class
PCB - PCS Licensed Transmitter