Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
CEILING FAN REMOTE CONTROLLER OPERATION AND INSTALLATION INSTRUCTIONS (Please keep this instruction pamphlet.) IMPORTANT POINTS TO REMEMBER: 1.Read and save these instructions. 2.Please note that all fixed wiring appliances should be installed by a qualified electrician. 3.The supply to the remote control receiver should be connected through a mains switch, i.e. existing wall switch. 4.Disconnect from power supply at wall switch before working on remote control receiver or ceiling fan. 5.Install receiver into the ceiling fan canopy of the fan to ensure proper protection. 6.This unit is to be used for the control of ceiling fan and in a AC110/120V 60Hz power supply only. 7.Do not install in damp locations or immerse in water. (For indoor use only.) 8.Do not pull on or cut leads shorter. 9.Do not drop or bump the unit. 10. PLEASE NOTE: The battery will weaken with age and should be replaced before leaking takes place as this will damage the transmitter. Dispose of used battery properly, keep the battery out of reach of children. 11. CAUTION: To reduce the risk of fire or injury, do not use this product in conjunction with any variable (rheostat) wall control. INSTALLATION INSTRUCTIONS 1.Ceiling fan must be set at HIGH speed and light kit (If any) at ON position by pressing the “Light Switch” after installation. 2.Once the connection has been made, the receiver inserts into the drop rod hanging bracket. The canopy comes up to cover the receiver and bracket. IMPORTANT YOU MUST SET CEILING FAN MANUAL SWITCH TO HIGH SPEED AND LIGHT KIT (IF ANY) TO ON POSITION BEFORE OPERATING REMOTE CONTROL. CAUTION: INCORRECT WIRE CONNECTION WOULD DAMAGE THIS RECEIVER. FUNCTIONS OF TRANSMITTER FAN:Press and release immediately to turn on the fan at HI speed,MED speed,LOW speed,off. LIGHT:Press and release immediately to turn on or off the light. Press and hold to dim or brighten lights to the desired level and release. (Only for the tungsten bulb.). Ceiling Fan Remote Control Wiring Connection Installation of Transmitter Wall Mount Holder with two screws. LIGHT FAN FCC IDKUJCE10203 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CEILING FAN REMOTE CONTROLLER OPERATION AND INSTALLATION INSTRUCTIONS (Please keep this instruction pamphlet.) IMPORTANT POINTS TO REMEMBER: 1. Read and save these instructions. 2. Please note that all fixed wiring appliances should be installed by a qualified electrician. 3. The supply to the remote control receiver should be connected through a mains switch, i.e. existing wall switch. 4. Disconnect from power supply at wall switch before working on remote control receiver or ceiling fan. 5. Install receiver into the ceiling fan canopy of the fan to ensure proper protection. 6. This unit is to be used for the control of ceiling fan and in an AC120V 60Hz power supply only. 7. Do not install in damp locations or immerse in water. (For indoor use only.) 8. Do not pull on or cut leads shorter. 9. Do not drop or bump the unit. 10. PLEASE NOTE: The battery will weaken with age and should be replaced before leaking takes place as this will damage the transmitter. Dispose of used battery properly, and keep the battery out of reach of children. 11. CAUTION: To reduce the risk of fire or injury, do not use this product in conjunction with any variable (rheostat) wall control. INSTALLATION INSTRUCTIONS 1. Ceiling fan must be set at HIGH speed and light kit (If any) at ON position by pressing the “Light Switch” after installation. 2. Once the connection has been made, the receiver inserts into the drop rod hanging bracket. The canopy comes up to cover the receiver and bracket. IMPORTANT YOU MUST SET CEILING FAN MANUAL SWITCH TO HIGH SPEED AND LIGHT KIT (IF ANY) TO ON POSITION BEFORE OPERATING REMOTE CONTROL. CAUTION: INCORRECT WIRE CONNECTION WOULD DAMAGE THIS RECEIVER. LEARNING PROCESS 1. This unit finished learning process inside manufactory, if replace transmitter or receiver, user need to redo learning process before using this unit. Receiver could remember up to 5pcs transmitter. 2. After installing the unit and power on, open battery cover (with battery, DC9V 1pc, installed) and press and use a ball pen to hold ”LEARNING” key 1~3seconds, FAN will be turn off and the turn to medium speed, which indicate that learning process finished. Learning effect distance is same with remote’s. Please note that must press the “LEARNING KEY” within 30sensonds after power on. If just replace batteries, no need to re-learn. 3. Please note that the transmitter can learn in multiple receiver, when doing learning process please make sure not learn in other receiver. Suggest to separate power switches of fans in 2 meter range. LEARN DIMMER OFF LIGHT FUNCTION SELECT SWITCH 1. If installed energy light onto ceiling fan, please slide the “light function select switch” to on/off position. If installed tungsten light onto ceiling fan, please slide the “light function select switch” to dimmer position. 2. Light load: 190W (Max.) If overload, the receiver will cut off light power automatically. Please change the light load. FUNCTIONS OF TRANSMITTER LIGHT : ON/OFF- Press and release immediately to turn on or off the light. DIMMER-Press and hold to dim or brighten light to the desired level and release. (Tungsten only and light function select switch on dimmer position.) FAN : Turn on the ceiling fan at High speed, medium, low or turn off power. TRANSMITTER LIGHT FUNCTION SELECT SWITCH LEARNING KEY FCC IDKUJCE10203 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Jul. 29, 2013 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Subject: Family model declaration letter Model No.: (1)JY610C (2)JY610C-L (FCC ID: KUJCE10203) We hereby state that these models are identical in interior structure, electrical circuits and RF Spec, The differences are in control receiver (JY610C is dip switch mode, Y610C-L is learning ID mode). Sincerely, Peter Chen / Manager Chungear Industrial Co., Ltd. 106 Kanho Rd., Taichung, Taiwan
SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (current) 2.0 3.0 Jan-31-2012 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 3.0 Jul. 29, 2013 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, Chungear Industrial Co., Ltd. hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): Product Name: Ceiling Fan Remote Controller (Transmitter) Model Name: JY610C, JY610C-L We affirm that between SIEMIC and Chungear Industrial Co., Ltd. any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Peter Chen / Manager Chungear Industrial Co., Ltd. 106 Kanho Rd., Taichung, Taiwan
SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (current) 2.0 3.0 Jan-31-2012 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 3.0 Jul. 29, 2013 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Chungear Industrial Co., Ltd. for FCC ID: KUJCE 10203 We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Schematics - Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Peter Chen / Manager Chungear Industrial Co., Ltd. 106 Kanho Rd., Taichung, Taiwan
Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller (Transmitter) FCC ID : KUJCE10203 EUT External Photos Photo 1 JY610C, General Appearance (Front & Side View) Photo 2 JY610C, General Appearance (Back & Side View)
Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller (Transmitter) FCC ID : KUJCE10203 Photo 3 JY610C-L, General Appearance (Front & Side View) Photo 4 JY610C-L, General Appearance (Back & Side View)
Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller (Transmitter) FCC ID : KUJCE10203 ID Label Location z Label Placement Location (Back View of EUT) JY610C z ID Label Format FCC ID KUJCE10203 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. ID Label Placement Location
Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller (Transmitter) FCC ID : KUJCE10203 ID Label Location z Label Placement Location (Back View of EUT) JY610C-L z ID Label Format FCC ID KUJCE10203 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. ID Label Placement Location
Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller (Transmitter) FCC ID : KUJCE10203 EUT Internal Photos Photo 5 JY610C, Internal View (Removed Battery Cover) Photo 6 JY610C, Internal View (Removed Covers) Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller (Transmitter) FCC ID : KUJCE10203 Photo 7 JY610C, Internal View (Main Board, Front View) Photo 8 JY610C, Internal View (Main Board, Back View)
Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller (Transmitter) FCC ID : KUJCE10203 Photo 9 JY610C-L, Internal View (Removed Battery Cover) Photo 10 JY610C-L, Internal View (Removed Covers) Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller (Transmitter) FCC ID : KUJCE10203 Photo 11 JY610C-L, Internal View (Main Board, Front View) Photo 12 JY610C-L, Internal View (Main Board, Back View)
FCC ID. KUJCE10203 Page 1 of 25 AUDIX Technology Corporation Report No.: EM-F1020532 TEST REPORT FOR CERTIFICATION On Behalf of Chungear Industrial Co., Ltd Ceiling Fan Remote Controller (Transmitter) Model No.: (1)JY610C (2)JY610C-L FCC ID: KUJCE10203 Prepared for : Chungear Industrial Co., Ltd 106 Kanho Rd., Taichung, Taiwan Prepared By : AUDIX Technology Corporation EMC Department No. 53-11, Dingfu, Linkou Dist., New Taipei City 244, Taiwan Tel : (02) 2609-9301, 2609-2133 Fax : (02) 2609-9303 File Number C1M1307046 Report Number EM-F1020532 Date of Test Jul. 08 ~ 30, 2013 Date of Report Jul. 30, 2013 FCC ID. KUJCE10203 Page 2 of 25 AUDIX Technology Corporation Report No.: EM-F1020532 TABLE OF CONTENTS Description Page TEST REPORT CERTIFICATION........................................................................................................3 1. GENERAL INFORMATION ..........................................................................................................4 1.1. Description of Device (EUT) .................................................................................................................. 4 1.2. Description of Test Facility..................................................................................................................... 6 1.3. Measurement Uncertainty ....................................................................................................................... 6 2. CONDUCTED EMISSION MEASUREMET................................................................................7 3. RADIATED EMISSION MEASUREMENT .................................................................................8 3.1. Test Equipment ....................................................................................................................................... 8 3.2. Test Setup................................................................................................................................................ 8 3.3. Radiation Emission Limits (§15.209) ................................................................................................... 10 3.4. Operating Condition of EUT................................................................................................................. 10 3.5. Test Procedure....................................................................................................................................... 10 3.6. Radiated Emission Noise Measurement Results ................................................................................... 11 4. FUNDAMENTAL MEASUREMENT ..........................................................................................13 4.1. Test Equipment ..................................................................................................................................... 13 4.2. Test Setup.............................................................................................................................................. 13 4.3. Radiation Emission Limits (15.231) ..................................................................................................... 14 4.4. Operating Condition of EUT................................................................................................................. 14 4.5. Test Procedure....................................................................................................................................... 14 4.6. Fundamental Measurement Results ...................................................................................................... 15 5. EMISSION BANDWIDTH MEASUREMENT ...........................................................................17 5.1. Test Equipment ..................................................................................................................................... 17 5.2. Block Diagram of Test Setup ................................................................................................................ 17 5.3. Specification Limits (§15.231-(c))........................................................................................................ 17 5.4. Emission Bandwidth Measurement Results..........................................................................................17 6. PERIODIC OPERATED MEASUREMENT ..............................................................................19 6.1. Test Equipment ..................................................................................................................................... 19 6.2. Block Diagram of Test Setup ................................................................................................................ 19 6.3. Specification Limits [§15.231-(a)-(1)].................................................................................................. 19 6.4. Periodic Operated Measurement Results .............................................................................................. 19 7. DEVIATION TO TEST SPECIFICATIONS...............................................................................21 8. PHOTOGRAPHS............................................................................................................................22 8.1. Photos of Radiated Measurement at Semi-Anechoic Chamber (30~1000MHz) .................................. 22 8.2. Photos of Radiated Measurement at Semi-Anechoic Chamber (Above 1GHz)................................. 23 8.3. Photo of Section RF Near Field Measurement......................................................................................25 FCC ID. KUJCE10203 Page 3 of 25 AUDIX Technology Corporation Report No.: EM-F1020532 TEST REPORT CERTIFICATION Applicant Chungear Industrial Co., Ltd Manufacturer #1 Chungear Industrial Co., Ltd Manufacturer #2 Satellite Electronic (Zhongshan) Ltd. Manufacturer #3 Zhongshan Amity Electronic Ltd. EUT Description Ceiling Fan Remote Controller (Transmitter) FCC I…
Text truncated - open the document above for the full version.
FCC ID. KUJCE10203 Page 22 of 25 AUDIX Technology Corporation Report No.: EM-F1020532 8. PHOTOGRAPHS 8.1. Photos of Radiated Measurement at Semi-Anechoic Chamber (30~1000MHz) EUT on Stand EUT on Side FCC ID. KUJCE10203 Page 23 of 25 AUDIX Technology Corporation Report No.: EM-F1020532 EUT on Lying 8.2. Photos of Radiated Measurement at Semi-Anechoic Chamber (Above 1GHz) EUT on Stand FCC ID. KUJCE10203 Page 24 of 25 AUDIX Technology Corporation Report No.: EM-F1020532 EUT on Side EUT on Lying FCC ID. KUJCE10203 Page 25 of 25 AUDIX Technology Corporation Report No.: EM-F1020532 8.3. Photo of Section RF Near Field Measurement
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 304 MHz - 304 MHz | - |

Ceiling Fan Remote Controller(Transmitter)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Ceiling Fan Remote Controller (Transmitter)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Ceiling Fan Remote Controller (Transmitter)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Ceiling Fan Remote Controller (Transmitter)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
CEILING FAN REMOTE CONTROLLER (TRANSMITTER)
Equipment Class
DTS - Digital Transmission System