FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Chungear Industrial Co Ltd/
  3. KUJCE10301

KUJCE10301Ceiling Fan Remote Controller (Transmitter)

Chungear Industrial Co Ltd
Ceiling Fan Remote Controller (Transmitter) - FCC ID KUJCE10301 - Chungear Industrial Co Ltd
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Apr 28, 2014
Application Purpose
Original Equipment
Date of Application
Apr 28, 2014
Equipment Note
Ceiling Fan Remote Controller (Transmitter)
Frequency Range
303.87500000 - 303.87500000
Company
Chungear Industrial Co Ltd
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CEILINGFAN REMOTECONTROLLER OPERATIONAND INSTALLATIONINSTRUCTIONS (Pleasekeep this instructionpamphlet.) IMPORTANTPOINTSTO REMEMBER: 1.Read and save these instructions. 2.Please note that all fixed wiring appliancesshouldbe installedby a qualifiedelectrician. 3.The supplyto the remotecontrolreceivershouldbe connectedthrougha mains switch,i.e. existingwall switch. 4.Disconnectfrom power supplyat wall switch before workingon remotecontrolreceiveror ceilingfan. 5.Install receiverinto the ceilingfan canopyof the fan to ensure proper protection. 6.This unit is to be used for the controlof ceilingfan and in aAC 110/120V 60Hz power supplyonly. 7.Do not install in damp locationsor immersein water. (For indoor use only.) 8.Do not pull on or cut leads shorter. 9.Do not drop or bump the unit. 10. PLEASENOTE:The batterywill weakenwith age and shouldbe replacedbefore leakingtakes place as this will damagethe transmitter.Disposeof used batteryproperly,keep the batteryout of reach of children. 11. CAUTION:To reducethe risk of fire or injury, do not use this productin conjunctionwith any variable (rheostat)wall control. INSTALLATIONIN STRUCTIONS 1.Ceilingfan must be set at HIGH speed and light kit (If any) at ON positionby pressingthe β€œLight Switch ” after installation. 2.Once the connectionhas been made, the receiverinserts into the drop rod hangingbracket.The canopy comes up to cover the receiverand bracket. IMPORTANT YOU MUSTSET CEILINGFAN MANUALSWITCHTO HIGH SPEEDAND LIGHTKIT (IF ANY) TO ON POSITIONBEFOREOPERATINGREMOTECONTROL. CAUTION:INCORRECTWIRE CONNECTIONWOULDDAMAGETHIS RECEIVER. CODESWITCH 1.CODESWITCH:Codes are set by pushingdip switchesup or down. It is imperativethat the code used for both transmitterand receiveris exactlythe same, otherwiseremotecontrollerwill not work. Please note the code switch will enable you to operatea secondremotecontrollerindependently.For example,if you have two ceilingfans with 2 remotecontrolunits, set 2 differentcodes for each set of transmitter/receivers.This means you can operateeach ceilingfan independently. 2.Your remotecontrolis ready for use after batteryinstallation. FUNCTIONSOF TRANSMITTER OFF: Turn off the fan. HI: Turn on the fan at high speed . MED: Turn on the fan at mediumspeed LOW: Turn on the fan at low speed LIGHT: Press and releaseimmediatelyto turn on or off the light. Press and hold to dim or brightenlights to the desired level and release.(Only for the tungstenbulb.) . Ceiling Fan Remote Control Wiring Connection TRANSMITTER OFF HI MED LOW LIGHT TR191A FCC IDKUJCE10301 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Cover Letter(s)

SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (current) 2.0 3.0 Jan-31-2012 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 3.0 Apr. 24, 2014 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, Chungear Industrial Co., Ltd. hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): Product Name: Ceiling Fan Remote Controller (Transmitter) Model Name: TR191A We affirm that between SIEMIC and Chungear Industrial Co., Ltd. any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Peter Chen / Manager Chungear Industrial Co., Ltd. 106 Kanho Rd., Taichung, Taiwan

Cover Letter(s)

SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (current) 2.0 3.0 Jan-31-2012 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 3.0 Apr. 24, 2014 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Chungear Industrial Co., Ltd. for FCC ID: KUJCE10301 We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Schematics - Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Peter Chen / Manager Chungear Industrial Co., Ltd. 106 Kanho Rd., Taichung, Taiwan

External Photos

Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller (Transmitter) FCC ID : KUJCE10301 EUT External Photos Photo 1 General Appearance (Front & Side View) Photo 2 General Appearance (Back & Side View)

ID Label/Location Info

Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller (Transmitter) FCC ID : KUJCE10301 ID Label Location z Label Placement Location (Back View of EUT) TR191A z ID Label Format FCC ID KUJCE10301 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. ID Label Placement Location

Internal Photos

Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller (Transmitter) FCC ID : KUJCE10301 EUT Internal Photos Photo 3 Internal View (Removed Battery Cover) Photo 4 Internal View (Removed Covers) Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller (Transmitter) FCC ID : KUJCE10301 Photo 5 Internal View (Main Board, Front View) Photo 6 Internal View (Main Board, Back View)

Test Report

FCC ID. KUJCE10301 Page 1 of 25 AUDIX Technology Corporation Report No.: EM-F140232 TEST REPORT FOR CERTIFICATION On Behalf of Chungear Industrial Co., Ltd Ceiling Fan Remote Controller (Transmitter) Model No.: TR191A FCC ID: KUJCE10301 Prepared for : Chungear Industrial Co., Ltd 106 Kanho Rd., Taichung, Taiwan Prepared By : AUDIX Technology Corporation EMC Department No. 53-11, Dingfu, Linkou Dist., New Taipei City 244, Taiwan Tel : (02) 2609-9301, 2609-2133 Fax : (02) 2609-9303 File Number C1M1403275 Report Number EM-F140232 Date of Test 2014. 03. 27 ~ 04. 21 Date of Report 2014. 04. 22 FCC ID. KUJCE10301 Page 2 of 25 AUDIX Technology Corporation Report No.: EM-F140232 TABLE OF CONTENTS Description Page TEST REPORT CERTIFICATION........................................................................................................3 1. DESCRIPTION OF VERSION .......................................................................................................4 2. GENERAL INFORMATION ..........................................................................................................5 2.1. Description of Device (EUT) .................................................................................................................. 5 2.2. Description of Test Facility..................................................................................................................... 7 2.3. Measurement Uncertainty ....................................................................................................................... 7 3. CONDUCTED EMISSION MEASUREMET................................................................................8 4. RADIATED EMISSION MEASUREMENT .................................................................................9 4.1. Test Equipment ....................................................................................................................................... 9 4.2. Test Setup................................................................................................................................................ 9 4.3. Radiation Emission Limits (Β§15.209) ................................................................................................... 11 4.4. Operating Condition of EUT................................................................................................................. 11 4.5. Test Procedure....................................................................................................................................... 11 4.6. Radiated Emission Noise Measurement Results ................................................................................... 12 5. FUNDAMENTAL MEASUREMENT ..........................................................................................14 5.1. Test Equipment ..................................................................................................................................... 14 5.2. Test Setup.............................................................................................................................................. 14 5.3. Radiation Emission Limits (15.231) ..................................................................................................... 15 5.4. Operating Condition of EUT................................................................................................................. 15 5.5. Test Procedure....................................................................................................................................... 15 5.6. Fundamental Measurement Results ...................................................................................................... 16 6. EMISSION BANDWIDTH MEASUREMENT ...........................................................................17 6.1. Test Equipment ..................................................................................................................................... 17 6.2. Block Diagram of Test Setup ................................................................................................................ 17 6.3. Specification Limits (Β§15.231-(c))........................................................................................................ 17 6.4. Emission Bandwidth Measurement Results..........................................................................................17 7. PERIODIC OPERATED MEASUREMENT ..............................................................................19 7.1. Test Equipment ..................................................................................................................................... 19 7.2. Block Diagram of Test Setup ................................................................................................................ 19 7.3. Specification Limits [Β§15.231-(a)-(1)].................................................................................................. 19 7.4. Periodic Operated Measurement Results .............................................................................................. 19 8. DEVIATION TO TEST SPECIFICATIONS...............................................................................21 9. PHOTOGRAPHS............................................................................................................................22 9.1. Photos of Radiated Measurement at Semi-Anechoic Chamber (30~1000MHz) .................................. 22 9.2. Photos of Radiated Measurement at Semi-Anechoic Chamber (Above 1GHz)................................. 23 9.3. Photo of Section RF Near Field Measurement......................................................................................25 FCC ID. KUJCE10301 Page 3 of 25 AUDIX Technology Corporation Report No.: EM-F140232 TEST REPORT CERTIFICATION Applicant Chungear Industrial Co., Ltd Manufacturer #1 Chungear Industrial Co., Ltd Manufacturer #2 Satellite Electronic (Zhongshan) Ltd.…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID. KUJCE10301 Page 22 of 25 AUDIX Technology Corporation Report No.: EM-F140232 9. PHOTOGRAPHS 9.1. Photos of Radiated Measurement at Semi-Anechoic Chamber (30~1000MHz) EUT on Stand EUT on Side FCC ID. KUJCE10301 Page 23 of 25 AUDIX Technology Corporation Report No.: EM-F140232 EUT on Lying 9.2. Photos of Radiated Measurement at Semi-Anechoic Chamber (Above 1GHz) EUT on Stand FCC ID. KUJCE10301 Page 24 of 25 AUDIX Technology Corporation Report No.: EM-F140232 EUT on Side EUT on Lying FCC ID. KUJCE10301 Page 25 of 25 AUDIX Technology Corporation Report No.: EM-F140232 9.3. Photo of Section RF Near Field Measurement

Contact Information

Applicant

Peter Chen(Engineer Manager)
[email protected]886-4-2359-6418Fax: 886-4-2359-6419

Test Firm

Audix Technology CorporationLeon Liu
[email protected]886-2-26092133Fax: 886-2-26099303

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231303.875 MHz - 303.875 MHz-
Confidentiality
Long Term

Other Applications from Chungear Industrial Co Ltd

Ceiling Fan Remote Controller(Transmitter) - FCC ID KUJCE11101 - Chungear Industrial Co Ltd
KUJCE11101

Ceiling Fan Remote Controller(Transmitter)

May 03, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Ceiling Fan Remote Controller (Transmitter) - FCC ID KUJCE10901 - Chungear Industrial Co Ltd
KUJCE10901

Ceiling Fan Remote Controller (Transmitter)

Sep 03, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Ceiling Fan Remote Controller (Transmitter) - FCC ID KUJCE10705 - Chungear Industrial Co Ltd
KUJCE10705

Ceiling Fan Remote Controller (Transmitter)

Apr 11, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Ceiling Fan Remote Controller (Transmitter) - FCC ID KUJCE10721 - Chungear Industrial Co Ltd
KUJCE10721

Ceiling Fan Remote Controller (Transmitter)

Feb 18, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
CEILING FAN REMOTE CONTROLLER (TRANSMITTER) - FCC ID KUJCE10406 - Chungear Industrial Co Ltd
KUJCE10406

CEILING FAN REMOTE CONTROLLER (TRANSMITTER)

Nov 18, 2015

Equipment Class

DTS - Digital Transmission System