Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC IDKUJCE9909 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 2.0 2206 Ringwood Avenue San Jose, CA 95131 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (current) 1.0 1.0 Nov-14-2006 Revised wording (current) 1.0 2.0 Sept–25-2007 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 2.0 Apr. 14, 2011 To: SIEMIC, INC. 2206 Ringwood Avenue, San Jose, CA 95131 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, Chungear Industrial Co., Ltd. hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): Product Name: Ceiling Fan Remote Controller (Transmitter) Model Name: TR113A (FCC ID: KUJCE9909) We affirm that between SIEMIC and Chungear Industrial Co., Ltd., any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Peter Chen / Manager Chungear Industrial Co., Ltd. 106 Kanho Rd., Taichung, Taiwan
SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 2.0 2206 Ringwood Avenue San Jose, CA 95131 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (current) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 1.0 2.0 August – 11 - 2008 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 2.0 Apr. 14, 2011 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Confidentiality Request regarding application for certification of FCC ID: KUJCE9909 We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Operational Description - Schematic Diagram The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Peter Chen / Manager Chungear Industrial Co., Ltd. 106 Kanho Rd., Taichung, Taiwan
Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller (Transmitter) FCC ID : KUJCE9909 EUT External Photos Photo 1 General Appearance (Front & Side View) Photo 2 General Appearance (Back & Side View)
Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller (Transmitter) FCC ID : KUJCE9909 ID Label Location z Label Placement Location (Bottom Side of EUT) z ID Label Format Model No.: TR113A Serial No.: FCC ID. : KUJCE9909 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Made in China. ID Label Placement Location
Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller (Transmitter) FCC ID : KUJCE9909 EUT Internal Photos Photo 3 Internal View (Battery Covers Removed) Photo 4 Internal View (Covers Removed) Chungear Industrial Co., Ltd. Ceiling Fan Remote Controller (Transmitter) FCC ID : KUJCE9909 Photo 5 PCB View (Front Side) Photo 6 PCB View (Back Side)
FCC ID. KUJCE9909 Page 1 of 24 AUDIX Technology Corporation Report No.: EM-F100344 TEST REPORT FOR CERTIFICATION On Behalf of Chungear Industrial Co., Ltd Ceiling Fan Remote Controller (Transmitter) Model No.: TR113A FCC ID: KUJCE9909 Prepared for : Chungear Industrial Co., Ltd 106 Kanho Rd., Taichung, Taiwan Prepared By : AUDIX Technology Corporation EMC Department No. 53-11, Tin-Fu Tsun, Lin-Kou Hsiang, Taipei Hsien, Taiwan, R.O.C. Tel : (02) 2609-9301, 2609-2133 Fax : (02) 2609-9303 File Number C1M1104035 Report Number EM-F100344 Date of Test Apr. 12, 2011 Date of Report Apr. 14, 2011 FCC ID. KUJCE9909 Page 2 of 24 AUDIX Technology Corporation Report No.: EM-F100344 TABLE OF CONTENTS Description Page TEST REPORT CERTIFICATION........................................................................................................3 1. GENERAL INFORMATION ..........................................................................................................4 1.1. Description of Device (EUT) .................................................................................................................. 4 1.2. Description of Test Facility..................................................................................................................... 5 1.3. Measurement Uncertainty ....................................................................................................................... 5 2. CONDUCTED EMISSION MEASUREMENT .............................................................................6 3. RADIATED EMISSION MEASUREMENT .................................................................................7 3.1. Test Equipment ....................................................................................................................................... 7 3.2. Test Setup................................................................................................................................................ 7 3.3. Radiation Emission Limits (§15.209) ..................................................................................................... 8 3.4. Operating Condition of EUT................................................................................................................... 8 3.5. Test Procedure......................................................................................................................................... 9 3.6. Radiated Emission Noise Measurement Results .....................................................................................9 3.7. Duty Cycle Factor ................................................................................................................................. 10 4. FUNDAMENTAL MEASUREMENT ..........................................................................................12 4.1. Test Equipment ..................................................................................................................................... 12 4.2. Test Setup.............................................................................................................................................. 12 4.3. Radiation Emission Limits (15.231) ..................................................................................................... 13 4.4. Operating Condition of EUT................................................................................................................. 13 4.5. Test Procedure....................................................................................................................................... 13 4.6. Fundamental Measurement Results ...................................................................................................... 14 5. EMISSION BANDWIDTH MEASUREMENT ...........................................................................15 5.1. Test Equipment ..................................................................................................................................... 15 5.2. Block Diagram of Test Setup ................................................................................................................ 15 5.3. Specification Limits (§15.231-(c))........................................................................................................ 15 5.4. Emission Bandwidth Measurement Results..........................................................................................15 6. PERIODIC OPERATED MEASUREMENT ..............................................................................17 6.1. Test Equipment ..................................................................................................................................... 17 6.2. Block Diagram of Test Setup ................................................................................................................ 17 6.3. Specification Limits [§15.231-(a)-(1)].................................................................................................. 17 6.4. Periodic Operated Measurement Results .............................................................................................. 17 7. DEVIATION TO TEST SPECIFICATIONS...............................................................................19 8. PHOTOGRAPHS............................................................................................................................20 8.1. Photos of Radiated Measurement at Semi-Anechoic Chamber (30~1000MHz).......................................... 20 8.2. Photos of Radiated Measurement at Semi-Anechoic Chamber (Above 1GHz) ........................................ 22 8.3. Photo of Emission Bandwidth/ Periodic Operated/ Measurement ........................................................ 24 FCC ID. KUJCE9909 Page 3 of 24 AUDIX Technology Corporation Report No.: EM-F100344 TEST REPORT CERTIFICATION Applicant Chungear Industrial Co., Ltd Manufacturer #1 Chungear Industrial Co., Ltd Manufacturer #2 Satellite…
Text truncated - open the document above for the full version.
FCC ID. KUJCE9909 Page 20 of 24 AUDIX Technology Corporation Report No.: EM-F100344 8. PHOTOGRAPHS 8.1. Photos of Radiated Measurement at Semi-Anechoic Chamber (30~1000MHz) EUT on Stand EUT on Side FCC ID. KUJCE9909 Page 21 of 24 AUDIX Technology Corporation Report No.: EM-F100344 EUT on Lying FCC ID. KUJCE9909 Page 22 of 24 AUDIX Technology Corporation Report No.: EM-F100344 8.2. Photos of Radiated Measurement at Semi-Anechoic Chamber (Above 1GHz) EUT on Stand EUT on Side FCC ID. KUJCE9909 Page 23 of 24 AUDIX Technology Corporation Report No.: EM-F100344 EUT on Lying FCC ID. KUJCE9909 Page 24 of 24 AUDIX Technology Corporation Report No.: EM-F100344 8.3. Photo of Emission Bandwidth/ Periodic Operated/ Measurement
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 304 MHz - 304 MHz | - |

Ceiling Fan Remote Controller(Transmitter)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Ceiling Fan Remote Controller (Transmitter)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Ceiling Fan Remote Controller (Transmitter)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Ceiling Fan Remote Controller (Transmitter)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
CEILING FAN REMOTE CONTROLLER (TRANSMITTER)
Equipment Class
DTS - Digital Transmission System