Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
To whom it may concern Date: 27 June 2024 Attestation of Measurement method FCC ID: KVW-QPS2KP2 IC ID: 4431C-QPW2KP2, HVIN: QPW2K Report: 80186184-05_Rev1 and 80186184-06_Rev1 We, CSA Group Bayern GmbH (as agent for Rohde & Schwarz GmbH & Co. KG), hereby want to declare the size of the Rohde & Schwarz GmbH & Co. KG device QPS Walk2000 does not allow to perfom the transmission measurements acc. to FCC §15.517, §15.521 and ISED RSS-220 using the whole device. Thus, the TCB deemed it as necessary to perfom the UWB measurements acc. to FCC §15.517, §15.521 and ISED RSS-220 with a single, separate UWB transmitter unit which behaves exactly like an UWB transmitter in the device, as only one UWB transmitter is active at a time in the application. The measurements acc. to FCC §15.109, §15.209 and ISED ICES-003, Issue 7 have been performed with a complete Rohde & Schwarz QPS Walk2000 device. The manufacturer Rohde & Schwarz will follow the SDoC procedure acc. to FCC 15B and ICES-003. Sincerely, Marie-Luise Schuster GMA Project Coordinator CSA Group Bayern GmbH
Request for Confidentiality Date: 2024-06-27 Subject: Confidentiality Request for FCC ID: KVW-QPW2KP2 and IC: 4431C-QPW2KP2 Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 12.4, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality RequestedExhibit Short TermPermanentBlock Diagrams Short TermExternal Photos Short Term Permanent* 1 Internal Photos Short TermPermanentOperation Description/Theory of Operation Short TermPermanentParts List & Placement/BOM Short TermPermanentTune-Up Procedure Short Term PermanentSchematics Short TermTest Setup Photos Short TermPermanent* 3 User’s Manual Rohde & Schwarz GmbH & Co. KG has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of ___(specify number of days not to exceed 180) ___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify Phoenix Testlab GmbH in the event information regarding the product or the product is made available to the public. Phoenix Testlab GmbH will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: IC currently only distinguishes Permanent Confidentiality exhibits as shown above. Short Term confidentiality is not 1 - The asterisked items (*) require further information to be provided to the TCB before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 and the specific Document link for D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. considered applicable to IC applications. Sincerely, By:__________________________Marie-Luise Schuster (Signature/Title 2 )GMA Project Coordinator 2 -Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
Product Label Lable Location Lable
The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . CSA Group Bayern GmbH File No. 80186184-07 Rev1, page 1 of 10 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 6.3, 2021-11-03 CSA Confidential R F − T E S T R E P O R T - Human Exposure - Type / Model Name : R&S® QPS Walk2000 P2 Product Description : Walk-through security scanner Applicant : Rohde & Schwarz GmbH & Co. KG Address : Mühldorfstraße 15 81614 MÜNCHEN, GERMANY Manufacturer : Rohde & Schwarz GmbH & Co. KG Address : Mühldorfstraße 15 81614 MÜNCHEN, GERMANY Test Result according to the standards listed in clause 1 test standards: POSITIVE Test Report No. : 80186184-07 Rev1 25. June 2024 ________________________________________________________________ ___________ ____________ _______ Date of issue The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: KVW-QPW2KP2 IC: 4431C-QPW2KP2 CSA Group Bayern GmbH File No. 80186184-07 Rev1, page 2 of 10 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 6.3, 2021-11-03 CSA Confidential Contents 1 T E S T S T A N D A R D S 3 2 E Q U I P M E N T U N D E R T E S T 4 2.1 Information provided by the Client 4 2.2 Sampling 4 2.3 Photo documentation of the EUT – See ATTACHMENT A 4 2.4 Equipment type, category 4 2.5 Short description of the equipment under test (EUT) 4 2.6 Variants of the EUT 4 2.7 Operation frequency and channel plan 4 2.8 Transmit operating modes 4 2.9 Antennas 5 2.10 Power supply system utilised 5 3 T E S T R E S U L T S U M M A R Y 6 3.1 Revision history of test report 6 3.2 Final assessment 6 4 T E S T E N V I R O N M E N T 7 4.1 Address of the test laboratory 7 4.2 Environmental conditions 7 4.3 Statement of the measurement uncertainty 7 5 H U M A N E X P O S U R E 8 5.1 RF output power consideration 8 5.2 SAR test exclusion considerations 9 5.3 Exemption limits for routine evaluation - SAR evaluation 10 ATTACHMENT A as separate supplement The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: KVW-QPW2KP2 IC: 4431C-QPW2KP2 CSA Group Bayern GmbH File No. 80186184-07 Rev1, page 3 of 10 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 6.3, 2021-11-03 CSA Confidential 1 T E S T S T A N D A R D S The tests were perf ormed according to f ollowing standards: FCC Rules and Regulations Part 1, Subpart I - Procedures Implementing the National Environmental Policy Act of 1969 Part 1, Subpart I, Section 1.1310 Radiof requency radiation exposure limits Part 1, Subpart 2, Section 2.1091 Radiofrequency radiation exposure evaluation: mobile devices. Part 1, Subpart 2, Section 2.1093 Radiofrequency radiation exposure evaluation: portable devices. KDB 447498 D04 RF Exposure procedures and equipment authorisation policies for mobile and portable devices, November 29, 2021. RSS-102 Issue 5, March 2015 Radio Frequency (RF) Exposure Compliance of Radiocommunication apparatus (All Frequnecy Bands) Health Canada Notice, January 2021 Localized human exposure limits f or radiof requency f ields in the range of 6 GHz to 300 GHz ISED Notice 2016-DRS0001 Applicability of Latest FCC RF Exposure KDB Procedures and September 20, 2016, updated July 2020 Other Procedures ISED Notice 2021-DRS0005 Introduction of an interim exemption limit for routine localized power July 20, 2021 density evaluations of transmitters operating in the 6 – 30 GHz f requency range ANSI C95.1: 2005 IEEE Standard for Safety Levels with respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz ETSI TR 100 028 V1.3.1: 2001-03, Electromagnetic Compatibility and Radio Spectrum Matters (ERM); Uncertainties in the Measurement of Mobile Radio Equipment Characteristics—Part 1 and Part 2 The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: KVW-QPW2KP2 IC: 4431C-QPW2KP2 CSA Group Bayern GmbH File No. 80186184-07 Rev1, page 4 of 10 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 6.3, 2021-11-03 CSA Confidential 2 E Q U I P M E N T U N D E R T E S T 2.1 Information provided by the Client Please note, we do not take any responsibility for information provided by the client or his representative which may have an inf luence on the validity of the test results. 2.2 Sampling The customer is responsible for the choice of sample. Sample configuration, start-up and operation is carried out by the customer or according his/her instructions. 2.3 Photo documentation of the EUT – See ATTACHMENT A 2.4 Equipment type, category Mobile UWB Device 2.5 Short description of the equipment under test (EUT) The QPS Walk2000 is the next generation of a walk through body scanning, designed to improve individuals’ security. The system is meant to be installed in f ixed indoor locations, generally in entrances to secured areas. The QPS Walk2000 automatically detects the existence of concealed unauthorized objects on an individual’s body. The end device consists of 224 transmitter modules and 448 receiver modules. All measurements were performed on a single transmitter to demonstrate that all requirements are f ulf illed. Number of tested samples: 1 Serial number: 100001 Material number: 1342.5100K02. 2.6 Variants of the EUT There are no variants. 2.7 Operation frequency and channel plan The operating f requency band is 3100 MHz to 10600 MHz f or FCC and 1990 MHz to 10600 MHz f or IC. 2.8 Transmit operating modes The signal consists of a sing…
Text truncated - open the document above for the full version.
C O M P A N Y R E S T R I C T E D QPS WALK2000 ANTENNA SPECIFICATION 1 Mechanical Drawing C O M P A N Y R E S T R I C T E D 2 Farfield Radiation Plots f [GHz] New design Phi=90° New design Phi=0° 3.5 4 C O M P A N Y R E S T R I C T E D 5 6 7 C O M P A N Y R E S T R I C T E D 8 9 9.5
The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . CSA Group Bayern GmbH File No. 80186184-05 Rev1, page 1 of 29 Straubinger Straße 100 94447 Plattling GERMANY Tel.:+49(0)9931-98360 Fax:+49(0)9931-9836440 Rev. No. 7.0, 2022-08-03 CSA Confidential EMI − T E S T R E P O R T - FCC Part 15.517, - Type / Model Name : R&S® QPS Walk2000 P2 Product Description : Walk-through security scanner Applicant : Rohde & Schwarz GmbH & Co. KG Address : Mühldorfstraße 15 81614 MÜNCHEN, GERMANY Manufacturer : Rohde & Schwarz GmbH & Co. KG Address : Mühldorfstraße 15 81614 MÜNCHEN, GERMANY Test Result according to the standards listed in clause 1 test standards: POSITIVE Test Report No. : 80186184-05 Rev1 31. July 2024 ________________________________________________________________ ___________ ____________ _______ Date of issue The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: KVW-QPW2KP2 CSA Group Bayern GmbH File No. 80186184-05 Rev1, page 2 of 29 Straubinger Straße 100 94447 Plattling GERMANY Tel.:+49(0)9931-98360 Fax:+49(0)9931-9836440 Rev. No. 7.0, 2022-08-03 CSA Confidential Contents 1 T E S T S T A N D A R D S 3 2 E Q U I P M E N T U N D E R T E S T 4 2.1 Information provided by the Client 4 2.2 Sampling 4 2.3 Photo documentation of the EUT – Detailed photos see ATTACHMENT A 4 2.4 Equipment type 4 2.5 Short description of the equipment under test (EUT) 4 2.6 Variants of the EUT 4 2.7 Operation frequency and channel plan 4 2.8 Transmit operating modes 4 2.9 Antenna 5 2.10 Power supply system utilised 5 2.11 Peripheral devices and interface cables 5 2.12 Determination of worst case conditions for final measurement 5 3 T E S T R E S U L T S U M M A R Y 6 3.1 Revision history of test report 6 3.2 Final assessment 7 4 T E S T E N V I R O N M E N T 8 4.1 Address of the test laboratory 8 4.2 Environmental conditions 8 4.3 Statement of the measurement uncertainty 8 4.4 Conformity Decision Rule 9 4.5 Measurement protocol for FCC and ISED 9 5 T E S T C O N D I T I O N S A N D R E S U L T S 12 5.1 AC power line conducted emissions 12 5.2 UWB Bandwidth 15 5.3 Radiated Emissions 9 kHz to 40 GHz 17 5.4 Radiated Emissions at 1164-1240 MHz and 1559-1610 MHz 23 5.5 Peak Power radiated 27 6 U S E D T E S T E Q U I P M E N T A N D A C C E S S O R I E S 29 ATTACHMENT A as separate supplements The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: KVW-QPW2KP2 CSA Group Bayern GmbH File No. 80186184-05 Rev1, page 3 of 29 Straubinger Straße 100 94447 Plattling GERMANY Tel.:+49(0)9931-98360 Fax:+49(0)9931-9836440 Rev. No. 7.0, 2022-08-03 CSA Confidential 1 T E S T S T A N D A R D S The tests were perf ormed according to f ollowing standards: FCC Rules and Regulations Part 15, Subpart C - Intentional Radiators (February 2024) Part 15, Subpart C, Section 15.203 Antenna requirement Part 15, Subpart C, Section 15.204 External radio frequency power amplifiers and antenna modifications Part 15, Subpart C, Section 15.207 Conducted limits Part 15, Subpart C, Section 15.209 Radiated emission limits, general requirements FCC Rules and Regulations Part 15, Subpart F – Ultra Wideband Operation (February 2024) Part 15, Subpart F, Section 15.503 Def initions Part 15, Subpart F, Section 15.505 Cross ref erence Part 15, Subpart F, Section 15.517 Technical requirements f or indoor UWB systems Part 15, Subpart F, Section 15.521 Technical requirements applicable to all UWB devices ANSI C63.10: 2013 Testing Unlicensed Wireless Devices ETSI TR 100 028 V1.3.1: 2001-03 Electromagnetic Compatibility and Radio Spectrum Matters (ERM); Uncertainties in the Measurement of Mobile Radio Equipment Characteristics—Part 1 and Part 2 KDB 393764 D01 v02r01 (April 25, 2022) Ultra-Wideband (UWB) Devices – Frequently Asked Questions The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permissi on of the test laboratory . FCC ID: KVW-QPW2KP2 CSA Group Bayern GmbH File No. 80186184-05 Rev1, page 4 of 29 Straubinger Straße 100 94447 Plattling GERMANY Tel.:+49(0)9931-98360 Fax:+49(0)9931-9836440 Rev. No. 7.0, 2022-08-03 CSA Confidential 2 E Q U I P M E N T U N D E R T E S T 2.1 Information provided by the Client Please note, we do not take any responsibility for information provided by the client or his representative which may have an inf luence on the validity of the test results. 2.2 Sampling The customer is responsible for the choice of sample. Sample configuration, start-up and operation is carried out by the customer or according his/her instructions. 2.3 Photo documentation of the EUT – Detailed photos see ATTACHMENT A 2.4 Equipment type UWB Device f or Indoor Use 2.5 Short description of the equipment under test (EUT) The QPS Walk2000 is the next generation of a walk through body scanning, designed to improve individuals’ security. The system is meant to be installed in f ixed indoor locations, generally in entrances to secured areas. The QPS Walk2000 automatically detects the existence of concealed unauthorized objects on an individual’s body. The end device consists of 224 transmitter modules and 448 receiver modules. All measurements were performed on a single transmitter to demonstrate that all requirements are f ulf illed. Number of tested samples: 1 Serial number: 100001 Material number: 1342.5100K02 2.6 Variants of the EUT There are no variants. 2.7 Operation frequency and channel plan The operating f requency band is 3100 MHz to 10600 MHz f or FCC. 2.8 Transmit operating modes The signal consists of a single pulse with 12 MHz repetition rate. The test report merely corresponds to …
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15F | 4.66 GHz - 9.38 GHz | - |

R&S QAR50 Quality Automotive Radome Tester
Equipment Class
8CC - Part 18 Consumer Device
R&S QAR Quality Automotive Radome Tester
Equipment Class
8CC - Part 18 Consumer Device
Quick Personnel Security Scanner (for QPS201), Loss Prevention System (for LPS)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
M3SR Series 4400 VHF/Transmitter
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
TNB - Licensed Non-Broadcast Station Transmitter
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter