FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. R F Technologies Inc/
  3. KXU-CBTX

KXU-CBTXProximity Reader

R F Technologies Inc
Proximity Reader - FCC ID KXU-CBTX - R F Technologies Inc
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Dec 14, 2010
Application Purpose
Original Equipment
Date of Application
Dec 13, 2010
Equipment Note
Proximity Reader
Frequency Range
318.00000000 - 318.00000000
Company
R F Technologies Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

3125 North 126th Street, Brookfield, WI 53005 USA phone: 800.669.9946 web: www.rft.com Series 7.0 Software User Guide PN 0510-1086-B Series 7.0 Software User Guide Supports the 9450 Series Systems, Quick Response Systems, 9500 Series Wired Systems and 9600 Series Systems PN: 0510-1086-B Release Date: 06/29/10 Users must read this Guide before using the Product. Copyright 2009, 2010 by RF Technologies, Inc. All Rights Reserved. No Part of this work may be reproduced or copied in any form or by any means without written permission from RF Technologies, Inc. Important Warnings It is important for your facility to implement and enforce the following WARNINGS in order to keep all equipment functioning properly. Disregarding the information and instructions in this document is considered abnormal use and may result in injury or system failure. WARNING ACCESSORIES (SUPPLIES)—To ensure patient safety and proper operation of equipment, use only parts and accessories manufactured or recommended by RF Technologies, Inc. Parts and accessories not manufactured or recommended by RF Technologies, Inc. may not meet the requirements of the applicable safety and performance standards. Failure to use the components and supplies specified by RF Technologies, Inc. may result in equipment and/or system failure. WARNING EXPLOSION HAZARD—These devices should not be used in the presence of flammable gas mixtures. It should also not be used in oxygen enriched atmospheres. WARNING INSTALLATION AND CONFIGURATION—It is the responsibility of the facility to follow the installation instructions carefully, as outlined in the applicable system guides, and to use the components and supplies specified by RF Technologies, Inc. for all installations. Failure to use the components and supplies specified by RF Technologies, Inc. may result in equipment and/or system failure. WARNING INSTRUCTIONS FOR SET UP AND USE—It is the responsibility of the facility to follow the instructions for set up and use carefully, as outlined in this manual, and to use the components and supplies specified by RF Technologies, Inc. for set up and use. Do not attempt to use extension cords or other equipment not supplied by RF Technologies, Inc. Failure to use the components and supplies specified by RF Technologies, Inc. may result in equipment and/or system failure. WARNING PATIENT GENERATED ALARMS—Do not rely exclusively on patient generated alarms for patient care and safety. The alarm function of equipment in the possession of patients must be verified periodically and regular patient surveillance is recommended. WARNING PATIENT MONITORING—The most reliable method of patient monitoring combines close personal surveillance with correct operation of monitoring equipment. It is the responsibility of the facility to periodically check on patients in possession of RF Technologies, Inc.'s equipment (i.e. Pendants, Pull Cords, Control Units) to mitigate risk of inappropriate use of equipment or strangulation and stumbling hazards from cables and cords WARNING PRODUCT WARRANTIES—Failure to follow the Warnings and Cautions in this guide voids any and all Product Warranties WARNING STATIC DISCHARGE—Do not touch the conductor portion of any conductor or port. Damage to the device may result. WARNING STRANGULATIONS AND TRIPPING HAZARD—Due to the possibility of strangulation, all cables and cords should be routed away from the patient’s throat. Cables and cords must be routed in a way to prevent tripping hazards. WARNING SYSTEM INSPECTION—It is the responsibility of the facility to establish and facilitate a regular inspection schedule for your system. RF Technologies, Inc. recommend quarterly inspections of your system for safety and performance by a qualified RF Technologies, Inc. representative. To arrange for a quarterly inspection by RF Technologies, Inc., call our Technical Support Department at (800)-669-9946 or (262) 790-1771. Failure to provide regular inspection of these products may result in equipment and/or system failure. WARNING SYSTEM MAINTENANCE AND TESTING—It is the responsibility of the facility to establish and facilitate a regular maintenance schedule for your system, as outlined in the applicable system guides. This includes regular inspection, testing, and cleaning. RF Technologies, Inc. recommend monthly maintenance and testing of your system. It is also recommended that your facility keep records of maintenance and test completions. Failure to provide regular maintenance and testing of these products may result in equipment and/or system failure. Bio-Incompatibility Notice Do not use Pendants with people that have sensitivities or allergies to device materials. The device materials include Acrylonitrile butadiene styrene (ABS), Silicon Rubber and Neoprene WARNING SYSTEM WIRING—All permanent supply connections must be done in accordance with National Electric Code, NFPA 70. WARNING USER TRAINING—Only users who have received adequate training on the use of the system, as outlined in this manual, should use the system. It is the responsibility of the facility to ensure all users have been trained. Failure to adequately train employees may cause system failure due to user error. In addition, incorrect use of the equipment may also result in system failure. WARNING WORN OR DAMAGED PARTS—If the control unit pads or cables are worn or damaged, you must have the product serviced. For more information, see the section entitled “Service and Return.” WA R N I N G All RF Technologies transmitters, pendants and banding material “PRODUCT” have been determined to be MR Unsafe as defined by ASTM F 2503-05. Use of “PRODUCT” in a Magnetic Resonance Imaging system will cause injury to patients and staff, MR system malfunction or “PRODUCT” malfunction. Do not bring “PRODUCT” into the MR system area and follow your facilities policies to classify and label “PRODUCT” as MR Unsafe. CAUTION DISPOSAL—At the end of their service life the products described …

Text truncated - open the document above for the full version.

Cover Letter(s)

FCC ID: KXU-CBTX D.L.S. ELECTRONIC SYSTEMS, INC. 166 South Carter Street Genoa City, WI 53128 December 6, 2010 FCC Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Gentlemen: We are submitting for RF Technologies, a Smart Sense Infant Transmitter (318 MHZ with either a 66 kHz or a 262 kHz Transmitter), Model Numbers: 9450-5066 & 9450- 5262, with an FCC ID: KXU-CBTX for Certification. This unit has been tested and complies with Part 15, Subpart C. FCC Certification is not required for the 66 kHz or 262 kHz transmitters since they meet the exemption as described in 47CFR Part 15.201(a). All emissions are >40dB below the limits set forth in 47CFR Part 15.209. These have been tested and verified pursuant to the procedures in 47CFR Part 2, Subpart J. One or the other is on the circuit board with the 318 MHz transmitter. If there are any questions in regard to this application, please call D.L.S. Electronic Systems, Inc. at (262) 279-0210. Enclosed you will find a copy of our test reports with the information and results of tests that is required under Part 15, Section 15.231. Thank you for your assistance in this matter. Sincerely, William M. Stumpf DLS/js

Cover Letter(s)

166 South Carter Street, Genoa City, WI 53128 Request for Confidentiality Date: 12/6/10 FCC Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 RE: Certification Application FCC ID: KXU-CBTX Pursuant to 47 CFR Section 0.459 RF Technologies, Inc. understands that requests for non disclosure and confidential treatment is being made for the following information as stated under the Code of Federal Regulations Chapter 47, Part 0.459 and behalf of APPLICANT NAMED: • Block Diagram • Schematics • Description of Operation The above materials contain trade secrets, proprietary and technical information that would customarily be guarded from competitors under 47 CFR section 0.457(d)(2). Disclosure or publication of any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. RF Technologies, Inc. understands that pursuant to 47 CFR section 0.457(d)(1)(ii) disclosure of the applicant and all accompanying documentation will not be made before the date of the grant. Thank you for your attention to this matter. Signatory William M. Stumpf OATS Manager D.L.S. Electronic Systems, Inc.

Cover Letter(s)

166 South Carter Street, Genoa City, WI 53128 Letter of Agency Date: 12/6/10 FCC Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 To Whom It May Concern: Please be advised that RF Technologies, Inc. authorizes D.L.S. Electronic Systems, Inc. to act on their behalf, until otherwise notified, for applications submitted to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, which include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002(b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you for your attention to this matter. Signatory, William M. Stumpf OATS Manager D.L.S. Electronic Systems, Inc. 166 South Carter Street, Genoa City, WI 53128 FCC Labeling Requirements and Information Date: 12/6/10 FCC Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 RE: FCC Labeling Requirements FCC ID: KXU-CBTX The following label information is required by the FCC Rules and Regulations for certified devices. Also attached, please find marketing information required by the FCC Rules and Regulations. Thank you for your attention to these matters. Sincerely, William M. Stumpf OATS Manager D.L.S. Electronic Systems, Inc. 166 South Carter Street, Genoa City, WI 53128 Modification Letter Date: 12/6/10 FCC Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 RE: Certification Application FCC ID: KXU-CBTX Please be advised that the following information is a list of modifications that will be included in the production process for the above-referenced equipment. Change 1: There were no modifications made during testing. Change 2: Change 3: Change 4: Change 5: Change 6: Change 7: Change 8: Change 9 Change 10: Thank you for your attention to this matter. Signatory William M. Stumpf OATS Manager D.L.S. Electronic Systems, Inc. 166 South Carter Street, Genoa City, WI 53128 Manufacturer’s Letter Date: 12/6/10 FCC Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 RE: Certification Application FCC ID: KXU-CBTX To Whom It May Concern: Please be advised that the manufacturer will ensure that the above-referenced model will be manufactured in accordance with the FCC Rules and Regulations. Thank you for your attention to this matter. Signatory William M. Stumpf OATS Manager D.L.S. Electronic Systems, Inc.

External Photos

Company: RF Technologies, Inc. Models: 9450-5066 & 9450-5262 Photo Description: Outside Front Company: RF Technologies, Inc. Models: 9450-5066 & 9450-5262 Photo Description: Outside Back Company: RF Technologies, Inc. Models: 9450-5066 & 9450-5262 Photo Description: FCC & IC ID’s Company: RF Technologies, Inc. Models: 9450-5066 & 9450-5262 Photo Description: Outside Covers

ID Label/Location Info

Smart Sense Product Marking Model Number Identification 1) Print model number on side of transmitter enclosure 2) Use Size 14 font 3) Printed Information a. Transmitters are labeled with an ink‐jet printer, with 2 lines of information centered on side of transmitter enclosure. b. The first line begins with the ID number (#xxx) followed by the Expiration month/year (EXP: xx/xx). The expiration is one year from the date of shipping. c. The second line contains the model number. Model 9450‐5066 Smart Sense Transmitter, 66 kHz Model 9450‐5262 Smart Sense Transmitter, 262 kHz Product Labeling with RFT Web Address (Both models) Place product label with RFT web address on top of enclosure FCC and IC numbers Molded into the underside of transmitter enclosure

ID Label/Location Info

Safe Place Infant Transmitter Label Artwork Part Number: 0700-0143-B Blank Label: 0150-0711 Created in Adobe Illustrator 10 Background or CMYK Equivalent or CMYK Equivalent

Internal Photos

Internal Photos of both models: Company: RF Technologies, Inc. Models: 9450-5066 & 9450-5262 Photo Description: Inside Covers Company: RF Technologies, Inc. Model: 9450-5066 Photo Description: Circuit Board Side 1 Model: 9450-5066 Photo Description: Circuit Board Side 2 Company: RF Technologies, Inc. Model: 9450-5262 Photo Description: Circuit Board Side 1 Model: 9450-5262 Photo Description: Circuit Board Side 2

Test Report

166 South Carter, Genoa City, WI 53128 1 of 37 Company: RF Technologies Model Tested: 9450-5262 and 9450-5066 Report Number: 16647 Project Number: 4331 i. Cover Page Code of Federal Regulations 47 Part 15 – Radio Frequency Devices Subpart C – Intentional Radiators Section 15.231 Periodic operation in the band 40.66 - 40.70 MHz and above 70 MHz & Section 15.209 Radiated Emission Limits: General Requirements THE FOLLOWING MEETS THE ABOVE TEST SPECIFICATION Formal Name: Smart Sense Infant Transmitter Kind of Equipment: Wireless Infant Security Device Frequency Range: 318 MHz and 262 kHz (Model 9450-5262) 318 MHz and 66 kHz (Model 9450-5066) Test Configuration: Body-worn, battery operated device tested in three orthogonal positions. Model Number(s): 9450-5262, 9450-5066 Model(s) Tested: 9450-5262, 9450-5066 Serial Number(s): none (Test Sample) Date of Tests: December 1, 2,3 and August 30 ,2010 Test Conducted For: RF Technologies, Inc. 3125 N. 126 th Street Brookfield, WI 53005 NOTICE: “This test report relates only to the items tested and must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government”. Please see the "Description of Test Sample" page listed inside of this report. © Copyright 1983 - 2010 D.L.S. Electronic Systems, Inc. COPYRIGHT NOTICE This report must not be reproduced (except in full), without the approval of D.L.S. Electronic Systems, Inc. 166 South Carter, Genoa City, WI 53128 2 of 37 Company: RF Technologies Model Tested: 9450-5262 and 9450-5066 Report Number: 16647 Project Number: 4331 ii. Signature Page SIGNAT URE PAGE Report By: Adam Alger Test Engineer Reviewed By: William Stumpf OATS Manager Approved By: Brian Mattson General Manager 166 South Carter, Genoa City, WI 53128 3 of 37 Company: RF Technologies Model Tested: 9450-5262 and 9450-5066 Report Number: 16647 Project Number: 4331 iii. Table of Contents Table of Contents i. Cover Page .......................................................................................................................................1 ii. Signature Page .................................................................................................................................2 iii. Table of Contents .............................................................................................................................3 iv. NVLAP Certificate of Accreditation ...............................................................................................4 1.0 Summary of Test Report ..................................................................................................................5 2.0 Introduction ......................................................................................................................................5 3.0 Test Facilities ...................................................................................................................................5 4.0 Description of Test Sample ..............................................................................................................6 5.0 Test Equipment ................................................................................................................................7 6.0 Test Arrangements ...........................................................................................................................8 7.0 Test Conditions ................................................................................................................................8 8.0 Modifications Made To EUT For Compliance ................................................................................8 9.0 Additional Descriptions ...................................................................................................................9 10.0 Results ..............................................................................................................................................9 11.0 Conclusion .......................................................................................................................................9 Appendix A – Test Setup Photos ...............................................................................................................10 Appendix B – Measurement Data ..............................................................................................................14 1.0 Emission Bandwidth – 20 dB ................................................................................................... 14 2.0 Automatic Deactivation ............................................................................................................ 16 3.0 Periodic Transmissions ............................................................................................................. 18 4.0 Field Strength of Emissions – Fundamental and Spurious (318 MHz) .................................... 21 5.0 Duty Cycle Correction (318 MHz) ........................................................................................... 24 6.0 Field Strength of Emissions – Fundamental and Spurious (66 & 262 kHz) ............................. 29 7.0 Duty Cycle Correction (66 & 262 kHz) .................................................................................... 32 166 South Carter, Genoa City, WI 53128 4 of 37 Company: RF Technologies Model Tested: 9450-5262 and 9450-5066 Report Number: 16647 Project Number: 4331 iv. NVLAP Certificate of Accreditation 166 South Carter, Genoa City, WI 53128 5 of 37 Company: RF Technologies Model Tested: 9450-5262 and 9450-5066 Report Number: 16647 Project Number: 4331 1.0 Summary of Test Report It was determined that the Smart Sense Infant Transmitter, Models 9450-5262 and 9450-5066, comply with the requirements of CFR 47 Part 15 Subpart C Section 15.231 and 15.209. Subpart C Applicable Technical Requirements Tested: Section Description Procedure Note Compliant? 15.231(c) 20 dB Emission Bandwidth ANSI C63.4-2009 & …

Text truncated - open the document above for the full version.

Test Setup Photos

Company: RF Technologies, Inc. Models: 9450-5066 & 9450-5262 Photo Description: Radiated Setup Company: RF Technologies, Inc. Models: 9450-5066 & 9450-5262 Photo Description: Radiated Position X Company: RF Technologies, Inc. Models: 9450-5066 & 9450-5262 Photo Description: Radiated Position Y Company: RF Technologies, Inc. Models: 9450-5066 & 9450-5262 Photo Description: Radiated Position Y – Prime Company: RF Technologies, Inc. Models: 9450-5066 & 9450-5262 Photo Description: Radiated Position Z

Contact Information

Applicant

Paul Larson(VP, Technology)
[email protected]262-853-6846Fax: 262-790-1784

Technical Contact

DLS Electronic SystemsBill Stumpf
[email protected]262-279-0210

166 South Carter Street · Genoa City, Wisconsin · United States

Test Firm

DLS Electronic Systems, Inc.William Stumpf
[email protected]262-279-0210Fax: 262-279-3630

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231318 MHz - 318 MHz-
Confidentiality
Long Term

Other Applications from R F Technologies Inc

KXU-SRTCCZ24V3

Quick Response Premiere Router/Gateway

Sep 21, 2015

Equipment Class

DTS - Digital Transmission System
Quick Response Premiere Nurse Call with Check In - FCC ID KXU-PCFSZ242 - R F Technologies Inc
KXU-PCFSZ242

Quick Response Premiere Nurse Call with Check In

Apr 12, 2015

Equipment Class

DTS - Digital Transmission System
Baby Check Transmitter - FCC ID KXU-MBTX2 - R F Technologies Inc
KXU-MBTX2

Baby Check Transmitter

Feb 11, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Code Alert CA630 - FCC ID KXU-FMFSZ24 - R F Technologies Inc
KXU-FMFSZ24

Code Alert CA630

Apr 22, 2013

Equipment Class

DTS - Digital Transmission System
Nurse Call/Communication Transmitter - FCC ID KXU-PGR2CCZ24 - R F Technologies Inc
KXU-PGR2CCZ24

Nurse Call/Communication Transmitter

Mar 07, 2010

Equipment Class

DTS - Digital Transmission System