® 3125 North 126th Street, Brookfield, WI 53005 Phone: 800.669.9946 Web: www.rft.com ®® Care Manager In-Service Guide P/N: 0510-1067-B Release Date: 02/26/10 Users must read this Guide before using the Product. < Compliance Federal Communication Commission (FCC) Compliance FCC ID: KXU-PGR2CCZ24 IC: 2719A-PGR2CCZ24 This device complies with Part 15 of the FCC rules. Operation is subject to the following to conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. Changes or modifications not expressly approved by RF Technologies could void the user’s authority to operate the equipment. FCC and IC Radiation Exposure Statement for Portable Devices (For the Care Manager model 9600-0500) This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment. This equipment is in direct contact with the body of the user under normal operating conditions. This transceiver must not be co-located or operating in conjunction with any other antenna or transceiver. Industry Canada Compliance Changes or modifications not expressly approved by RF Technologies could void the user’s authority to operate the equipment. The Term “IC” before the radio certification number only signifies that Industry Canada technical specifications were met. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. This device has been designed to operate with the antennas listed below, and having a maximum gain of 3dBi. Antennas not included in this list or having a gain greater than 3dBi are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. Acceptable antennas are PCB antennas in all cases of the Router which uses a 2.4 GHz 1/2 wave RP-SMA. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. Copyright 2010 by RF Technologies, Inc. All Rights Reserved. No Part of this work may be reproduced or copied in any form or by any means without written permission from RF Technologies, Inc. Important Warnings It is important for your facility to implement and enforce the following WARNINGS in order to keep all equipment functioning properly. Disregarding the information and instructions in this document is considered abnormal use and may result in injury or system failure. WARNING ACCESSORIES (SUPPLIES)—To ensure patient safety and proper operation of equipment, use only parts and accessories manufactured or recommended by RF Technologies, Inc. Parts and accessories not manufactured or recommended by RF Technologies, Inc. may not meet the requirements of the applicable safety and performance standards. Failure to use the components and supplies specified by RF Technologies, Inc. may result in equipment and/or system failure. WARNING EXPLOSION HAZARD—This device should not be used in the presence of flammable gas mixtures. It should also not be used in oxygen enriched atmospheres. WARNING HIGH RISK FOR FALL—The CA520 System may not be suitable for patients who are at “HIGH RISK FOR FALL.” Other monitoring measures may also be required. The Motion Alert System should not be a substitute for routine visual monitoring protocol by caregiving personnel. WARNING INSTALLATION AND CONFIGURATION—It is the responsibility of the facility to follow the installation instructions carefully, as outlined in the Series 6.0 Software Administrator Guide, and to use the components and supplies specified by RF Technologies, Inc. for all installations. Failure to use the components and supplies specified by RF Technologies, Inc. may result in equipment and/or system failure. WARNING INSTRUCTIONS FOR SET UP AND USE—It is the responsibility of the facility to follow the instructions for set up and use carefully, as outlined in this manual, and to use the components and supplies specified by RF Technologies, Inc. for set up and use. Do not attempt to use extension cords or other equipment not supplied by RF Technologies, Inc. Failure to use the components and supplies specified by RF Technologies, Inc. may result in equipment and/or system failure. WARNING PATIENT GENERATED ALARMS—Do not rely exclusively on patient generated alarms for patient care and safety. The alarm function of equipment in the possession of patients must be verified periodically and regular patient surveillance is recommended. WARNING PATIENT MONITORING—The most reliable method of patient monitoring combines close personal surveillance with correct operation of monitoring equipment. It is the responsibility of the facility to periodically check on patients in possession of RF Technologies, Inc.'s equipment (i.e. Pendants, Pull Cords, Control Units) to mitigate risk of inappropriate use of equipment or strangulation and stumbling hazards from cables and cords WARNING PRODUCT WARRANTIES—Failure to follow the Warnings and Cautions in this guide voids any and all Product Warranties WARNING STATIC DISCHARGE—Do not touch the conductor portion of any conductor or port. Damage tot he device may result. WARNING STRANGULATIONS AND TRIPPING HAZARD—Due to the possibility of strangulation, all cables and cords should be routed away from the patient’s throat. Cables and cords must be routed in a way to prevent tripping hazards. WARNING SYSTEM INSPECTION—It is the responsibility of the facility to establish and facilitate a regular inspection schedule for your system. RF Technologies, Inc. recommend quarterly inspections of your system for safety and performance by a qualified RF Technologies, Inc. representative. To arrange for a quarterly inspection by …
Text truncated - open the document above for the full version.
FCC ID: KXU-PGR2CCZ24 D.L.S. ELECTRONIC SYSTEMS, INC. 1250 Peterson Drive Wheeling, Illinois 60090 February 26, 2010 FCC Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Gentlemen: We are submitting for RF Technologies, Inc., Inc., an Code Alert Care Manager Transmitter, Model Number: 9600-0500, with an FCC ID: KXU-PGR2CCZ24 for Certification. This unit has been tested and complies to Part 15, Subpart C. If there are any questions in regard to this application, please call D.L.S. Electronic Systems, Inc. at (847) 537 6400. Enclosed you will find a copy of our test report with the information and results of tests that is required under Part 15, Section 15.247. Thank you for your assistance in this matter. Sincerely, Arnom C. Rowe EMC-001375-NE DLS/cp
1250 Peterson Dr., Wheeling, IL 60090 Request for Confidentiality Date: February 26, 2010 FCC Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 RE: Certification Application FCC ID: KXU-PGR2CCZ24 Pursuant to 47 CFR Section 0.459 RF Technologies, Inc. understands that requests for non disclosure and confidential treatment is being made for the following information as stated under the Code of Federal Regulations Chapter 47, Part 0.459 and behalf of APPLICANT NAME: • Block Diagram • Schematics • Description of Operation The above materials contain trade secrets, proprietary and technical information that would customarily be guarded from competitors under 47 CFR section 0.457(d)(2). Disclosure or publication of any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. RF Technologies, Inc. understands that pursuant to 47 CFR section 0.457(d)(1)(ii) disclosure of the applicant and all accompanying documentation will not be made before the date of the grant. Thank you for your attention to this matter. Signatory Arnom C. Rowe EMC ENGINEER EMC-001375-NE D.L.S. Electronic Systems, Inc.
Company: RF Technologies, Inc. Product: Code Alert Care Manager Photo Description: Top Company: RF Technologies, Inc. Product: Code Alert Care Manager Photo Description: Bottom Company: RF Technologies, Inc. Product: Code Alert Care Manager Photo Description: Side 1 Company: RF Technologies, Inc. Product: Code Alert Care Manager Photo Description: Side 2 Company: RF Technologies, Inc. Product: Code Alert Care Manager Photo Description: Side 3 Company: RF Technologies, Inc. Product: Code Alert Care Manager Photo Description: Side 4
3125 N. 126 th Street, Brookfield, Wisconsin 53005 Label Part Number: 0150-0712 Description: Pager FCC Label Revision: A Mark as follows: All lettering to be black Page: 1 Location of Label on Completed Unit Page: 2
Company: RF Technologies, Inc. Product: Code Alert Care Manager Photo Description: Covers Removed Company: RF Technologies, Inc. Product: Code Alert Care Manager Photo Description: Display Removed Company: RF Technologies, Inc. Product: Code Alert Care Manager Photo Description: Apart – Side 1 Company: RF Technologies, Inc. Product: Code Alert Care Manager Photo Description: Apart – Side 2 Company: RF Technologies, Inc. Product: Code Alert Care Manager Photo Description: Motherboard with Display Company: RF Technologies, Inc. Product: Code Alert Care Manager Photo Description: Motherboard Back & Back of Keypad
RF Exposure Statement 1. Standard Applicable According to 1.1307 (b)(1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. This is a portable device. 2. Measurement Result: This is a portable device and the max peak output power is –1.31 dBm (.00074 W). Lower than the low threshold 60/2405 MHz = (24.95 mW), distance <2.5 cm general population category. The SAR/MPE measurement is not necessary.
1250 Peterson Dr., Wheeling, IL 60090 Company: RF Technologies, Inc. Model Tested: 9600-0500 Report Number: 15811 FCC Rules and Regulations / Intentional Radiators Operational in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz, Bands Part 15, Subpart C, Section 15.247 THE FOLLOWING MEETS THE ABOVE TEST SPECIFICATION Formal Name: Code Alert Care Manager FCC ID: KXU-PGR2CCZ24 Kind of Equipment: Wireless Nurse Call and Security Device Frequency Range: 2405 MHz - 2475 MHz Test Configuration: Handheld (Tested at 3.7 vdc) Model Number(s): 9600-0500 Model(s) Tested: 9600-0500 Serial Number(s): N/A Date of Tests: November 9, 10, & 12, 2009 Test Conducted For: RF Technologies, Inc. 3125 N. 126th Street Brookfield, WI 53066 NOTICE: “This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government”. Please see the "Additional Description of Equipment Under Test" page listed inside of this report. © Copyright 1983-2009 D.L.S. Electronic Systems, Inc COPYRIGHT NOTICE This report must not be reproduced (except in full), without the approval of D.L.S. Electronic Systems, Inc. Page -1 of 78- 1250 Peterson Dr., Wheeling, IL 60090 Company: RF Technologies, Inc. Model Tested: 9600-0500 Report Number: 15811 SIGNATURE PAGE Report By: Arnom C. Rowe Test Engineer EMC-001375-NE Reviewed By: William Stumpf OATS Manager Approved By: Brian Mattson General Manager Page -2 of 78- 1250 Peterson Dr., Wheeling, IL 60090 Page -3 of 78- Company: RF Technologies, Inc. Model Tested: 9600-0500 Report Number: 15811 TABLE OF CONTENTS i. Cover Page .......................................................................................................................................1 ii. Signature Page .................................................................................................................................2 iii. Table of Contents .............................................................................................................................3 iv. NVLAP Certificate of Accreditation ...............................................................................................5 1.0 Summary of Test Report ..................................................................................................................6 2.0 Introduction......................................................................................................................................6 3.0 Object ...............................................................................................................................................6 4.0 Test Set-Up ......................................................................................................................................7 5.0 Test Equipment ................................................................................................................................8 6.0 Ambient Measurements ...................................................................................................................9 7.0 Description of Test Sample............................................................................................................10 8.0 Additional Description of Test Sample..........................................................................................11 9.0 Photo Information and Test Set-Up ...............................................................................................11 10.0 Photos Taken During Testing ........................................................................................................12 11.0 Results of Tests ..............................................................................................................................18 12.0 Conclusion .....................................................................................................................................18 TABLE 1 – EQUIPMENT LIST ...............................................................................................................19 1250 Peterson Dr., Wheeling, IL 60090 Company: RF Technologies, Inc. Model Tested: 9600-0500 Report Number: 15811 TABLE OF CONTENTS Appendix A – AC Power Line Conducted Emissions Test .......................................................................20 1a. AC Power Line Conducted Emission Measurements ....................................................................21 Appendix B – Electric Field Radiated Emissions Tests ............................................................................26 1b. Spurious Emissions at the Antenna Terminals/Antenna Connector ..............................................27 1b. RF Conducted Emission Data and Charts made at the Antenna Terminals ..................................28 2b. RF Conducted Emissions Photos Taken During Testing...............................................................41 3b. Restricted Bands ............................................................................................................................42 4b. Restricted Band and Band Edge Compliance ................................................................................42 4b. Data and Graph(s) taken showing the Restricted Band Compliance .............................................43 4b Data and Graph(s) taken showing the Lower Band Edge..............................................................47 4b. Data and Graph(s) taken of the Upper Band Edge with Restricted Band......................................50 5b. Field Strength of Fundamental and Spurious Emission Measurements ........................................53 5b. 30 MHz – 1000 MHz Radiated Graph(s) taken for Fundamental and Spurious Emission............55 5b. Radiated Data and Graph(s) taken for Fundamental and Spurious Emission................................59 6b. Transmitter Duty Cycle Graphs Taken During testing ..................................................................63 7b. 6 dB Bandwidth Graphs ta…
Text truncated - open the document above for the full version.
Company: RF Technologies, Inc. Product: Code Alert Care Manager Photo Description: Radiated – Front – X position Company: RF Technologies, Inc. Product: Code Alert Care Manager Photo Description: Radiated – Front – Y position Company: RF Technologies, Inc. Product: Code Alert Care Manager Photo Description: Radiated – Front – Z position Company: RF Technologies, Inc. Product: Code Alert Care Manager Photo Description: Radiated – Back Company: RF Technologies, Inc. Product: Code Alert Care Manager Photo Description: RF Conducted
1250 Peterson Drive · Wheeling, Illinois · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 740.00 µW |
Quick Response Premiere Router/Gateway
Equipment Class
DTS - Digital Transmission System
Quick Response Premiere Nurse Call with Check In
Equipment Class
DTS - Digital Transmission System
Baby Check Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Code Alert CA630
Equipment Class
DTS - Digital Transmission System
Proximity Reader
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter