Series 5.0 Software User Guide PN 0510-1059-A_DRAFT Series 5.0 Software User Guide Supports the 9450, 9600 Quick Response and Fall Management Systems PN: 0510-1059-A_DRAFT Release Date: 09/5/06 Users must read this guide before using the Product. Copyright 2006 by RF Technologies, Inc. All Rights Reserved. No Part of this work may be reproduced or copied in any form or by any means without written permission from RF Technologies, Inc. Important Warnings It is important for your facility to implement and enforce the following WARNINGS in order to keep all equipment functioning properly. WARNING INSTALLATION AND CONFIGURATION—It is the responsibility of the facility to follow the installation instructions carefully, as outlined in the Series 5.0 Software Administrator Guide, and to use the components and supplies specified by RF Technologies, Inc. for all installations. Failure to use the components and supplies specified by RF Technologies, Inc. may result in equipment and/or system failure. WARNING SYSTEM MAINTENANCE AND TESTING—It is the responsibility of the facility to establish and facilitate a regular maintenance schedule for your system, as outlined in the Series 5.0 Software Administrator Guide. This includes regular inspection, testing, and cleaning. RF Technologies, Inc. recommend monthly maintenance and testing of your system. It is also recommended that your facility keep records of maintenance and test completions. Failure to provide regular maintenance and testing of these products may result in equipment and/or system failure. WARNING SYSTEM INSPECTION—It is the responsibility of the facility to establish and facilitate a regular inspection schedule for your system. RF Technologies, Inc. recommend quarterly inspections of your system for safety and performance by a qualified RF Technologies, Inc. representative. To arrange for a quarterly inspection by RF Technologies, Inc., call our Technical Support Department at (800)-669-9946 or (262) 790-1771. Failure to provide regular inspection of these products may result in equipment and/or system failure. WARNING USER TRAINING—It is the responsibility of the facility to implement structured training procedures for all employees using the system. Only users who have received adequate training on the use of the system, as outlined in this manual, should use the system. Failure to adequately train employees may cause system failure due to user error. In addition, incorrect use of the equipment may also result in system failure. WARNING DISPOSAL—At the end of their service life the products described in this manual, as well as accessories (i.e. lithium batteries, banding material, disposable pads, etc.), must be disposed of in compliance with all applicable federal, state and local guidelines regulating the disposal of products containing potential environmental contaminants. Dispose of the packaging material by observing the applicable waste control regulations. WARNING PRODUCT WARRANTIES—Failure to follow the Warnings and Cautions in this guide voids any and all Product Warranties. Compliance Federal Communication Commission (FCC) Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes or modifications not expressly approved by the party responsible for compliance voids the user’s authority to operate the equipment. FCC and IC Radiation Exposure Statement for Mobile Devices (For the Pull Cord model 0800-0285 and 0800-0317; Universal Transceiver models 0800-0301, 0800-0303, and 0800-0304; Router model 0800-0287; and Asset Transceiver model 0800-0286) This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. FCC and IC Radiation Exposure Statement for Portable Devices (For the Pendant Transceiver model 0800-0288) This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment. This equipment is in direct contact with the body of the user under normal operating conditions. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Industry Canada Compliance Changes or modifications not expressly approved by RF Technologies could void the user’s authority to operate the equipment. The Term “IC” before the radio certification number only signifies that Industry Canada technical specifications were met. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. This device has been designed to operate with the antennas listed below, and having a maximum gain of 3dBi. Antennas not included in this list or having a gain greater than 3dBi are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. Acceptable antennas are PCB antennas in all cases of the Router which uses a 2.4 GHz 1/2 wave RP-SMA. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.)…
Text truncated - open the document above for the full version.
FCC ID: KXU-PCFSZ24 D.L.S. ELECTRONIC SYSTEMS, INC. 1250 Peterson Drive Wheeling, Illinois 60090 FCC Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21045-0429 Gentlemen: We are submitting for RF Technologies, Inc., Inc., a Help Alert Pull Cord Transmitter, Model Number: 0800-0285, with a FCC ID: KXU-PCFSZ24 for Certification. This unit has been tested and complies to Part 15, Subpart C. If there are any questions in regards to this application, please call D.L.S. Electronic Systems, Inc. at (847) 537 6400. Enclosed you will find a copy of our test report with the information and results of tests that is required under Part 15, Section 15.247. Thank you for your assistance in this matter. Sincerely, Arnom C. Rowe EMC-001375-NE DLS/sr
Request for Confidentiality Date: September 1, 2006 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 RE: Certification Application FCC ID: KXU-PCFSZ24 Pursuant to 47 CFR Section 0.459 RF Technologies, Inc. understands that requests for non disclosure and confidential treatment is being made for the following information as stated under the Code of Federal Regulations Chapter 47, Part 0.459 and behalf of APPLICANT NAME: • Block Diagram • Schematics • Descriptions of Operation The above materials contain trade secrets, proprietary and technical information that would customarily be guarded from competitors under 47 CFR section 0.457(d)(2). Disclosure or publication of any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. RF Technologies, Inc. understands that pursuant to 47 CFR section 0.457(d)(1)(ii) disclosure of the applicant and all accompanying documentation will not be made before the date of the grant. Thank you for your attention to this matter. Signatory Arnom C. Rowe EMC ENGINEER EMC-001375-NE D.L.S. Electronic Systems, Inc.
Safety for What Matters Most Wandering Management Solutions u Safety For What Matters Most Wandering Management Solutions u 3125 N. 126th St. Brookfield, WI 53005 1-800-669-9946 n 262-790-1771 n Fax: 262-790-1784 www.rft.com n [email protected] Top Tag line on all cut sheets Tite in Arial Bold Blue logo Centered, indivual tag line RFT logo and address at bottom on all Cut sheets Center text in Arial 10 pt regulat Headings Arial Bold 14 pt Bulleted list with Round Bullets Pull Cord Station 3125 N. 126th St. Brookfield, WI 53005 1-800-669-9946 n 262-790-1771 n Fax: 262-790-1784 www.rft.com n [email protected] Specifications Size Flush mount: 4.5"H x 2.7"W x .56"D (1 1.4cm x 6.7cm x 1.4cm) Surface Mount: 4.5"H x 2.7"W x 2.31"D (1 1.4cm x 6.7cm x 5.7cm) Weight 2.9 oz. (82.21g) Power 3.0V Lithium battery Battery Life 4-5 years Frequency 2.4 GHz Direct Sequence Spread Spectrum Frequency Range 2.405Hz - 2.480 GHz Bandwidth 5 MHz Transmit Power 0 dBm Certification FCC, Part 15 Zigbee 802.15.4 compliant Color White Mounting Options Surface Mount: Fits into a single gang surface plastic enclosure Flush Mount: Fits into a 20 square Inch non-metalic retrofit electrical box or into a 4" square non-metallic junction box with a single gang plaster ring. Features - Advanced 2.4 GHz Direct Sequence Spread Spectrum Technology - Fully supervised with continuous reassurance of proper operation - Optional check-in feature allows staff and residents to record non-alarm events in the computer system - Water resistant design allows for installation near showers and tubs The Pull Cord Station is used with the Quick Responses Wireless Call Solution. This wireless device can be mounted in a resident's room or bathroom, as well as in common areas such as activity rooms and wellness rooms. When used with the Code Alertu computer-based system, an optional Check-In button can be used by residents to "check in" with staff remotely, eliminating the need for staff rounds. Alternatively, it can be used by staff to record the number of times they were in the room assisting a resident. This information can then be used to compare times and quantity of services offered to a resident. Benefits: Easy to Use The Pull Cord Station allows residents to easily summon help with the pull of the cord. When the cord is pulled, a visual display "flag" appears assuring them that help was called for . A simple reset of the Pull Cord sends a reset message to the Wireless Call Solution and its pagers. Aesthetically Pleasing Design The low profile faceplate design of the Pull Cord blends in seamlessly with the wall and other decor. The red pull string aids in assisting residents with poor eyesight when calling for help. Stationary Yet Portable The Pull Cord operates on a self-contained battery, making installation or relocation of the Pull Cord Station very easy. When the battery is low, staff is continuously notified until the battery is changed. Check-In Button When in alarm the Visual Display flag shows "Help"
Letter of Agency Date: September 1, 2006 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: Please be advised that RF Technologies, Inc. authorizes D.L.S. Electronic Systems, Inc. to act on our behalf, until otherwise notified, for applications submitted to American Telecommunications Certification Body, Inc. (ATCB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002(b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you for your attention to this matter. Signatory, Arnom C. Rowe EMC ENGINEER EMC-001375-NE D.L.S. Electronic Systems, Inc. FCC Labeling Requirements and Information Date: September 1, 2006 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 RE: FCC Labeling Requirements FCC ID: KXU-PCFSZ24 The following label information is required by the FCC Rules and Regulations for certified devices. Also attached, please find marketing information required by the FCC Rules and Regulations. Thank you for your attention to these matters. Sincerely, Arnom C. Rowe EMC ENGINEER EMC-001375-NE D.L.S. Electronic Systems, Inc. Modification Letter Date: September 1, 2006 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 RE: Certification Application FCC ID: KXU-PCFSZ24 Please be advised that the following information is a list of modifications that will be included in the production process for the above-referenced equipment. Change 1: There were no modifications made during testing. Change 2: Change 3: Change 4: Change 5: Change 6: Change 7: Change 8: Change 9 Change 10: Thank you for your attention to this matter. Signatory Arnom C. Rowe EMC ENGINEER EMC-001375-NE D.L.S. Electronic Systems, Inc. Manufacturer’s Letter Date: September 1, 2006 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 RE: Certification Application FCC ID: KXU-PCFSZ24 To Whom It May Concern: Please be advised that the manufacturer will ensure that the above-referenced model will be manufactured in accordance with the FCC Rules and Regulations. Thank you for your attention to this matter. Signatory Arnom C. Rowe EMC ENGINEER EMC-001375-NE D.L.S. Electronic Systems, Inc.
Company: RF Technologies Model: 0800-0285 (Help Alert Pull Cord) FCC ID: KXU-PCFSZ24 IC: 2719A-PCFSZ24 Date: 06-23-2006 Photo Description: Front of EUT Company: RF Technologies Model: 0800-0285 (Help Alert Pull Cord) FCC ID: KXU-PCFSZ24 IC: 2719A-PCFSZ24 Date: 06-23-2006 Photo Description: Back of EUT
Label Part Number: 0150-0546 Description: Pull Cord FCC Label Revision: A UMark as follows: RF Technologies, Inc. Model: 0800-0285 FCC: KXU-PCFSZ24 IC: 2719A-PCFSZ24 Font: Arial Size: 9 All lettering to be black Use 1” x 1.25” label stock (RFT P/N 0440-0023) UProduct FCC/IC Label Location Product: Help Alert Pull Cord
Company: RF Technologies Model: 0800-0285 (Help Alert Pull Cord) FCC ID: KXU-PCFSZ24 IC: 2719A-PCFSZ24 Date: 06-23-2006 Photo Description: Front cover removed Company: RF Technologies Model: 0800-0285 (Help Alert Pull Cord) FCC ID: KXU-PCFSZ24 IC: 2719A-PCFSZ24 Date: 06-23-2006 Photo Description: Circuit board – component side Company: RF Technologies Model: 0800-0285 (Help Alert Pull Cord) FCC ID: KXU-PCFSZ24 IC: 2719A-PCFSZ24 Date: 06-23-2006 Photo Description: Circuit board – solder side Company: RF Technologies Model: 0800-0285 (Help Alert Pull Cord) FCC ID: KXU-PCFSZ24 IC: 2719A-PCFSZ24 Date: 06-23-2006 Photo Description: Inside covers
RF Exposure Exhibit for RF Technologies, Inc. KXU-PCFSZ24 Pull Cord Mobile Devices are defined as a transmitting device designed to be used in other than fixed locations and generally be used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter’s radiating structure(s) and the body of the user or nearby persons. Therefore, this device is classified under section 2.1091 as a “mobile” device. Although this device is categorically excluded from RF exposure evaluation under Part 2, it can be shown that the device meets the limits used for evaluating other devices (those which are not excluded) under this section. Section 2.1091 for mobile devices state that the limits are given in 1.1310. The limit given in 1.1310 for general population/uncontrolled at 2480 MHz is a Maximum Permissible Exposure (MPE) limit of 1 mW/cm 2 . For 2480 MHz this limit is 1 mW/cm 2 . The FCC OET Bulletin 65 Section 2 can be used to determine compliance with guidelines for human exposure to RF radiation. We will use equation 3 of that section for predicting RF fields. S = PG 4πR 2 S = power density (units e.g. mW/cm 2 ) P = power into to the antenna (or power output) (units e.g. mW) G = power gain of the antenna (worst case = 1) R = distance to the center of antenna (units e.g. cm) The highest power measurement for this device is -14.2 dBm. For this prediction we will use a worst-case power of -14.2 dBm or .0375 mW. Since the device is “mobile”, we will use a worst-case distance of 20 cm. For worst-case antenna gain, we will use a gain of one. Using equation 3 of OET Bulletin 65 Section 2, the power density is calculated to be 0.000007567 mW/cm 2 . This is well within the limit given in 1.1310.
1250 Peterson Dr., Wheeling, IL 60090 Company: RF Technologies, Inc. Model Tested: 0800-0285 Report Number: 12318 FCC Rules and Regulations / Intentional Radiators Operational in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz, Bands Part 15, Subpart C, Section 15.247 THE FOLLOWING ''MEETS'' THE ABOVE TEST SPECIFICATION Formal Name: Help Alert Pull Cord Kind of Equipment: Wireless Nurse Call Device Test Configuration: Wireless Connection (Tested at 3 vdc) Model Number(s): 0800-0285 Model(s) Tested: 0800-0285 Serial Number(s): NA Date of Tests: June 19 & 22, 2006 Test Conducted For: RF Technologies, Inc. 3125 N. 126th Street Brookfield, Wisconsin 53066 NOTICE: “This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government”. Please see the "Additional Description of Equipment Under Test" page listed inside of this report. © Copyright 1983- 2006 D.L.S. Electronic Systems, Inc COPYRIGHT NOTICE This report or any portion their of, may not be reproduced or modified in any form without the expressed written consent of D.L.S. Electronic Systems, Inc. Page - 1 - 1250 Peterson Dr., Wheeling, IL 60090 Company: RF Technologies, Inc. Model Tested: 0800-0285 Report Number: 12318 SIGNATURE PAGE Report By: Arnom C. Rowe Test Engineer EMC-001375-NE Reviewed By: William Stumpf OATS Manager Approved By: Brian Mattson General Manager Company Official: RF Technologies, Inc. Page - 2 - 1250 Peterson Dr., Wheeling, IL 60090 Company: RF Technologies, Inc. Model Tested: 0800-0285 Report Number: 12318 TABLE OF CONTENTS i. Cover Page..........................................................................................................................................1 ii. Signature Page....................................................................................................................................2 iii. Table of Contents...................................................................................................................................3 iv. NVLAP Certificate of Accreditation..............................................................................................5 1.0 Summary of Test Report.................................................................................................................6 2.0 Introduction.....................................................................................................................................6 3.0 Object..............................................................................................................................................6 4.0 Test Set-Up.....................................................................................................................................7 5.0 Test Equipment...............................................................................................................................7 6.0 Ambient Measurements..................................................................................................................8 7.0 Description of Test Sample.............................................................................................................9 8.0 Additional Description of Test Sample......................................................................................... 10 9.0 Photo Information and Test Set-Up..............................................................................................11 10.0 Radiated Photos Taken During Testing........................................................................................ 12 11.0 Results of Tests.............................................................................................................................15 12.0 Conclusion....................................................................................................................................15 TABLE 1 – EQUIPMENT LIST..............................................................................................................16 Page -3- 1250 Peterson Dr., Wheeling, IL 60090 Company: RF Technologies, Inc. Model Tested: 0800-0285 Report Number: 12318 TABLE OF CONTENTS Appendix A – Electric Field Radiated Emissions Test............................................................................. 18 1.0 Conducted Emission Measurements............................................................................................. 19 2.0 Spurious Emissions at the Antenna Terminals.............................................................................20 2.0 Conducted Emission Data and Charts made at the Antenna Terminals.......................................21 3.0 Restricted Bands...........................................................................................................................34 4.0 Band Edge and Restrict Band Compliance...................................................................................34 4.0 Data and Graph(s) taken showing the Band Edge Compliance....................................................35 4.0 Data and Graph(s) taken showing the Restrict Band Compliance................................................38 5.0 Field Strength of Spurious Emission Measurements....................................................................42 5.0 Radiated Data and Graph(s) taken for Field Strength Spurious Emission Measurements...........44 6.0 6 dB Bandwidth Graphs taken during testing...............................................................................54 6.0 Peak Power Spectral Density Graph(s) taken during testing........................................................58 6.0 Number of IEEE 802.15.4 Zigbee Frequencies taken during testing...........................................62 6.0 Time of Occupancy Graphs (Duty Cycle) taken during testing...................................................64 6.0 Conducted Peak Output Power Graphs Taken During testing......................................................68 Page…
Text truncated - open the document above for the full version.
Company: RF Technologies Model: 0800-0285 (Help Alert Pull Cord) FCC ID: KXU-PCFSZ24 IC: 2719A-PCFSZ24 Date: 06-23-2006 Photo Description: RF Conducted Company: RF Technologies Model: 0800-0285 (Help Alert Pull Cord) FCC ID: KXU-PCFSZ24 IC: 2719A-PCFSZ24 Date: 06-23-2006 Photo Description: Radiated Company: RF Technologies Model: 0800-0285 (Help Alert Pull Cord) FCC ID: KXU-PCFSZ24 IC: 2719A-PCFSZ24 Date: 06-23-2006 Photo Description: Radiated – Close-up
1250 Peterson Drive · Wheeling, Illinois · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 560.00 µW |
Quick Response Premiere Router/Gateway
Equipment Class
DTS - Digital Transmission System
Quick Response Premiere Nurse Call with Check In
Equipment Class
DTS - Digital Transmission System
Baby Check Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Code Alert CA630
Equipment Class
DTS - Digital Transmission System
Proximity Reader
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter