L3Z210008AM Deactivator Dual

Gunnebo Gateway AB
AM Deactivator Dual - FCC ID L3Z210008 - Gunnebo Gateway AB
Click to zoom

Application Details

Equipment Class
FAP - Part 15 Anti-Pilferage Device
Date of Grant
Nov 30, 2015
Application Purpose
Original Equipment
Date of Application
Nov 30, 2015
Equipment Note
AM Deactivator Dual
Frequency Range
0.05800000 - 0.05800000
Company
Gunnebo Gateway AB
Country
Sweden

Documents & Files

Select a file to view

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

1(3) External photos AM Deactivator Dual AM Deactivator Dual AM Deactivator Dual 2(3) AM Deactivator Dual AM Deactivator Dual 3(3) AM Deactivator Dual AM Deactivator Dual

ID Label/Location Info

1(1) Label and label location AM Deactivator Dual AM Deactivator Dual

Internal Photos

1(3) Internal photos AM Deactivator Dual AM Deactivator Dual 2(3) AM Deactivator Dual 3(3) AM Deactivator Dual

Test Report

Test report No. 908455-2, Ed. 3 Page 2 (19) Revision History Edition Date Description 1 2009-09-29 First release 2 2014-02-27 Section 7, Occupied 99% bandwidth test is added. Carrier field strength for supply voltage variations is added to section 5.6 3 2015-10-16 New edition where the test results are compared to current requirements (new edition of RSS-Gen). Update is made under project number 1401003. Test report No. 908455-2, Ed. 3 Page 3 (19) CONTENTS Page 1. Client information................................................................................................................ 4 2. Equipment under test (EUT) ............................................................................................... 4 2.1 Identification of the EUT according to the manufacturer/client declaration ............. 4 2.2 Modifications during the test .................................................................................... 4 3. Test specifications .............................................................................................................. 5 3.1 Standards ................................................................................................................. 5 3.2 Additions, deviations and exclusions from standards .............................................. 5 3.3 Test set-up ............................................................................................................... 5 3.4 Test conditions ......................................................................................................... 5 4. Test summary ..................................................................................................................... 6 5. Radiated emission in the frequency range 9 kHz – 1000 MHz .......................................... 7 5.1 Measurement uncertainty ......................................................................................... 7 5.2 Test equipment ........................................................................................................ 7 5.3 Measurement set-up, Magnetic field strength .......................................................... 8 5.4 Measurement set-up, Electric field strength ............................................................. 9 5.5 Limits ...................................................................................................................... 10 5.6 Test protocol .......................................................................................................... 11 6. Conducted disturbance voltage in the frequency range 0,15 - 30 MHz ........................... 15 6.1 Measurement uncertainty ....................................................................................... 15 6.2 Test equipment ...................................................................................................... 15 6.3 Measurement set-up .............................................................................................. 16 6.4 Test protocol .......................................................................................................... 17 7. Occupied 99% bandwidth test .......................................................................................... 18 7.1 Test equipment ...................................................................................................... 18 7.2 Measurement set-up .............................................................................................. 18 7.3 Test protocol .......................................................................................................... 18 8. Photos of the EUT ............................................................................................................ 19 Test report No. 908455-2, Ed. 3 Page 4 (19) CLIENT INFORMATION 1. The EUT has been tested by request of Company: Gunnebo Gateway AB Skogsvaktaregatan 3 591 62 Motala SWEDEN Name of contact: Claes Kemmer EQUIPMENT UNDER TEST (EUT) 2. 2.1 Identification of the EUT according to the manufacturer/client declaration Equipment: AM deactivator Type / Model: AM deactivator Dual Brand name: Gunnebo Serial number: Unmarked Manufacturer: Gunnebo Gateway AB Rating/Supplying voltage: 120 V AC, 60 Hz External antenna connector: No Operating temperature range: 0 to +55 °C Frequency range: 58 kHz Number of channels: 1 Stand by mode supported: No 2.2 Modifications during the test No modifications have been made during the tests. Test report No. 908455-2, Ed. 3 Page 5 (19) TEST SPECIFICATIONS 3. 3.1 Standards 47 CFR Part 15, Subpart C, Intentional radiators 47 CFR Part 15, Subpart B, Unintentional radiators RSS-Gen, Issue 4 (Nov 2014) RSS-210, Issue 8 (Dec 2010) Measurements methods according to ANSI C63.10-2013 3.2 Additions, deviations and exclusions from standards No additions, deviations or exclusions have been made from standards. 3.3 Test set-up Measurement set-up for radiated spurious emissions test is described in corresponding section. Measurement set-up for conducted emissions test is described in corresponding section. 3.4 Test conditions If not additionally specified, the tests were performed under the following environmental conditions: Parameter Normal Supplying voltage 120 V AC, 60 Hz Air temperature 23 °C Test report No. 908455-2, Ed. 3 Page 6 (19) TEST SUMMARY 4. The results in this report apply only to the sample tested. FCC reference IC reference Test Result Note 15.209 RSS-210 2.5 RSS-Gen Table 5 Radiated emission PASS 15.207 RSS-Gen Table 3 Conducted emission PASS - RSS GEN 4.6.1 99 % band width PASS Test report No. 908455-2, Ed. 3 Page 7 (19) RADIATED EMISSION IN THE FREQUENCY RANGE 9 KHZ – 1000 MHZ 5. 5.1 Measurement uncertainty Radiated emission with loop antenna, 9 kHz - 30 MHz:  3,2 dB Radiated disturbance electric field intensity, 30 – 1000 MHz:  4,8 dB The measurement uncertainty describes the overall uncertainty of the given measured value during operation of the EUT. Measuremen…

Text truncated - open the document above for the full version.

Test Setup Photos

TEST SET-UP PHOTOS AM DEACTIVATOR DUAL Magnetic field strength Electric field strength Conducted disturbance voltage

Contact Information

Applicant

Claes Kemmer(Technical Development MAnager)
[email protected]+46-141-237237Fax: +46-141-215080

Technical Contact

Gunnebo Gateway ABClaes Kemmer
[email protected]+46-141-237237

Motala · Sweden

Non-Technical Contact

Gunnebo Gateway ABClaes Kemmer
[email protected]+46-141-237237

Test Firm

Intertek Semko ABHenriki Wikstroem
[email protected]+46 8 750 0000

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.058 MHz - 0.058 MHz-
Confidentiality
Long Term
Grant Notes
The device and its antenna(s) must operate witha minimum separation distance from all persons, as specified in this filing, d(20 cm)

Other Applications from Gunnebo Gateway AB

Anti shoplifting system - FCC ID L3Z210019 - Gunnebo Gateway AB
L3Z210019

Anti shoplifting system

Dec 16, 2015

Equipment Class

FAP - Part 15 Anti-Pilferage Device
AM Deactivator Single - FCC ID L3Z210020 - Gunnebo Gateway AB
L3Z210020

AM Deactivator Single

Nov 30, 2015

Equipment Class

FAP - Part 15 Anti-Pilferage Device
L3ZGS-201

FAP - Part 15 Anti-Pilferage Device

Nov 21, 1995

Equipment Class

FAP - Part 15 Anti-Pilferage Device