FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Smarthome Products Ltd/
  3. LQP-RX600

LQP-RX600Wireless Chime Receiver

Smarthome Products Ltd
Wireless Chime Receiver - FCC ID LQP-RX600 - Smarthome Products Ltd
Click to zoom

Application Details

Equipment Class
CRR - Superregenerative Receiver
Date of Grant
Sep 23, 2003
Application Purpose
Original Equipment
Date of Application
Sep 23, 2003
Equipment Note
Wireless Chime Receiver
Frequency Range
315.00000000 - 315.00000000
Company
Smarthome Products Ltd
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Mike Kuo From: [email protected] Sent: September24 2003 Wednesday 5:52 PM To: [email protected] Subject: Re: Smarthome Product FCC ID:LQP-RX600, AN03T3195 9/24/2003 In a message dated 9/24/2003 3:10:14 AM Eastern Daylight Time, [email protected] writes: Question #1: What is the associated Transmitter FCC ID number will be used and marketed with this receiver ? Question #2: Two identical internal photo files are submitted. Please provide external photos. Question #3: What is the upper frequency range investigated ? Question #4: Please provide user manual. Hi, Mike. Here is the info on user manual and TX FCC ID. The manual of RX600 is attached. FCC ID of the Tx is LQP-WB007-16. Thanks for your attentions. Wei

External Photos

FCC ID: LQP-RX600 ——————————————————————————————————————————————— Advanced Compliance Lab 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 15 Figure 6.1 Front View FCC ID: LQP-RX600 ——————————————————————————————————————————————— Advanced Compliance Lab 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 16 Figure 7.2 Rear View Figure 7.2 Rear View

ID Label/Location Info

FCC ID: LQP-RX600 ——————————————————————————————————————————————— Advanced Compliance Lab 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 8 2. PRODUCT LABELING Fig 2.1 FCC ID Label Fig. 2.2 Location of Label on the back of EUT FCC ID FCC ID: LQP-RX600 This device complies with part 15 of the FCC Rules. Operating is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

FCC ID: LQP-RX600 ——————————————————————————————————————————————— Advanced Compliance Lab 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 17 Figure 6.3 Inside View FCC ID: LQP-RX600 ——————————————————————————————————————————————— Advanced Compliance Lab 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 18 Figure 6.4 PCB Component View FCC ID: LQP-RX600 ——————————————————————————————————————————————— Advanced Compliance Lab 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 19 Figure 6.5 PCB Foil View

Schematics

FCC ID: LQP-RX600 ——————————————————————————————————————————————— Advanced Compliance Lab 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 11 4. SYSTEM SCHEMATICS Figure 4.1 System Schematics

Test Report

ELECTROMAGNETIC EMISSION COMPLIANCE REPORT of WIRELESS CHIME RECEIVER MODEL: RC533/RC532 FCC ID: LQP-RX600 AUGUST 18, 2003 This report concerns (check one): Original grant x Class II change Equipment type: Superregenerative Receiver Deferred grant requested per 47 CF 0.457(d)(1)(ii)? yes no x If yes, defer until: (date) Company agrees to notify the Commission by (date) of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37? yes no x If no, assumed Part 15, Subpart B for unintentional radiators - the new 47 CFR [10-1-90 Edition] provision. Report prepared for: SMARTHOME PRODUCTS LTD. Report prepared by: Advanced Compliance Lab Report number: 0048-030818-01 The test result in this report IS supported and covered by the NVLAP accreditation 6 Randolph Way Hillsborough, NJ 08844 Tel: (908) 927 9288 Fax: (908) 927 0728 Advanced Compliance Laboratory FCC ID: LQP-RX600 ——————————————————————————————————————————————— Advanced Compliance Lab 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 2 Table of Contents Report Cover Page .........................................................................................................1 Table of Contents ...........................................................................................................2 Figures.............................................................................................................................3 1. GENERAL INFORMATION ...................................................................................4 1.1 Verification of Compliance .........................................................................4 1.2 Equipment Modifications............................................................................5 1.3 Product Information....................................................................................6 1.4 Test Methodology.........................................................................................6 1.5 Test Facility ..................................................................................................6 1.6 Test Equipment ............................................................................................7 1.7 Statement of the Document Use..................................................................7 2. PRODUCT LABELING............................................................................................8 3. SYSTEM TEST CONFIGURATION ......................................................................9 3.1 Justification ..................................................................................................9 3.2 Special Accessories.......................................................................................9 3.3 Configuration of Tested System .................................................................9 4. SYSTEM SCHEMATICS .........................................................................................11 5. RADIATED EMISSION DATA ...............................................................................12 5.1 Field Strength Calculation ..........................................................................12 5.2 Test Methods and Conditions .....................................................................12 5.3 Test Data .......................................................................................................12 6. PHOTOS OF TESTED EUT ....................................................................................14 Figures FCC ID: LQP-RX600 ——————————————————————————————————————————————— Advanced Compliance Lab 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 3 Figure 2.1 FCC ID Label...............................................................................................8 Figure 2.2 Location of Label on Back of the EUT ......................................................8 Figure 3.1 Radiated Test Setup, Front View ..............................................................10 Figure 3.2 Radiated Test Setup, Rear View ...............................................................10 Figure 4.1 EUT Schematics ..........................................................................................11 Figure 6.1 Front View...................................................................................................15 Figure 6.2 Rear View ....................................................................................................16 Figure 6.3 Inside View, Cover Opened .......................................................................17 Figure 6.4 PCB Component View................................................................................18 Figure 6.5 PCB Foil View .............................................................................................19 FCC ID: LQP-RX600 ——————————————————————————————————————————————— Advanced Compliance Lab 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 4 1. GENERAL INFORMATION 1.1 Verification of Compliance EUT: WIRELESS CHIME RECEIVER Model: RC533/RC532 Applicant: SMARTHOME PRODUCTS LTD. Tel: Fax: Room B-812, Sea View Estate, 2-8 Watson Rd. North Point, Hong Kong +(852)2566 1832 +(852)2510 8742 Test Type: FCC Part 15 CERTIFICATION Result: PASS Tested by: ADVANCED COMPLIANCE LABORATORY Test Date: August 18, 2003 Report Number: 0048-030818-01 The above equipment was tested by Advanced Compliance Laboratory for compliance with the requirement set forth in the FCC rules and regulations Part 15. This said equipment in the configuration described in the report, shows the maximum emission levels emanating from equipment are within the compliance requirements. The estimated uncertainty of the test result is given as following. The method of uncertainty calculation is provided in Advanced Compliance Lab. Doc . No. 0048-01-01. Prob. Dist.Uncertainty(dB) Un…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: LQP-RX600 ——————————————————————————————————————————————— Advanced Compliance Lab 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 10 Figure 3.1 Radiated Test Setup, Front View Figure 3.2 Radiated Test Setup, Rear View

Contact Information

Applicant

Katherine Leung
[email protected](852) 2566 1832Fax: (852) 2510 8742

Test Firm

Advanced Compliance LaboratoryWei Li
[email protected]908-927-9288Fax: 908-927-0728

Technical Specifications

#Rule PartsFrequency RangePower Output
115B315 MHz - 315 MHz-

Other Applications from Smarthome Products Ltd

Wireless Door Chime Receiver - FCC ID LQP-WP8901-WC201 - Smarthome Products Ltd
LQP-WP8901-WC201

Wireless Door Chime Receiver

Mar 10, 2015

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
Wireless Plug-in Door Chime Receiver - FCC ID LQP-WP8901-WRP200 - Smarthome Products Ltd
LQP-WP8901-WRP200

Wireless Plug-in Door Chime Receiver

Mar 10, 2015

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
Wireless Door Chime Receiver - FCC ID LQP-RX220 - Smarthome Products Ltd
LQP-RX220

Wireless Door Chime Receiver

Jan 07, 2015

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
Wireless Door Chime Receiver - FCC ID LQP-WP8901 - Smarthome Products Ltd
LQP-WP8901

Wireless Door Chime Receiver

Jan 07, 2015

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
433MHz Wireless Transmitter - FCC ID LQP-WB035 - Smarthome Products Ltd
LQP-WB035

433MHz Wireless Transmitter

Jan 01, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter