FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Attenti/
  3. LSQ-DCU-2010C

LSQ-DCU-2010CData collection unit, DCU 2010C

Attenti
Data collection unit, DCU 2010C - FCC ID LSQ-DCU-2010C - Attenti
Click to zoom

Application Details

Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Date of Grant
Oct 26, 2004
Application Purpose
Original Equipment
Date of Application
Oct 26, 2004
Equipment Note
Data collection unit, DCU 2010C
Frequency Range
318.00000000 - 318.00000000
Company
Attenti
Country
Israel

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

DCU 2010 INSTALLLATION MANUAL Version 1.0 April 2002 ElmoTech Ltd Version 1.0 DCU & Transmitter Field Installation Manual 1 Prepared by: Elmo-Tech Ltd. Corporate Headquarters 2 Ha-Barzel St. P.O. Box 13236 Ramat Ha-Chayal 61132 Tel Aviv Israel Tel: 03 – 6478871 Fax: 03 – 6478872 Visit us at: www.elmotech.com © 2002, Elmo Tech Ltd. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, for purpose other than the user’s manual, without prior permission of Elmo Tech Ltd. NO WARRANTY The technical documentation is being delivered AS-IS, and ElmoTech Ltd. makes no warranty as to its accuracy or use. Any use of the technical documentation or the information contained therein is at risk of the user. Documentation may include technical or other inaccuracies or typographical errors. ElmoTech Ltd. Reserves the right to make change without prior notice. Version 1.0 ElmoTech Ltd DCU & Transmitter Field Installation Manual 2 ElmoTech Ltd Version 1.0 DCU & Transmitter Field Installation Manual 3 TABLE OF CONTENTS Section Page THE MONITOR CENTER/ PROBATION AGENCY.................. 7 EQUIPMENT....................................................................................... 8 THE OFFENDER’S PREMISES...................................................... 9 MONITORING SYSTEM LOCATION...................................................... 9 INSTALLING THE DCU UNIT............................................................ 10 Downloading the Curfew Schedule............................................ 12 I NSTALLING THE TRANSMITTER....................................................... 14 Calibrating the Transmitter........................................................ 14 Attaching the Transmitter........................................................... 16 DCU Range Setting.................................................................... 19 DAILY OPERATING INSTRUCTIONS....................................... 23 I NCOMING CALLS............................................................................ 23 Accepting an incoming call........................................................ 23 OUTGOING CALLS........................................................................... 24 Performing an outgoing call....................................................... 24 GENERAL RULES FOR THE OFFENDER.............................................. 25 REMOVING THE MONITORING SYSTEM.............................. 27 INITIATING AN END OF SERVICE...................................................... 27 D ISCONNECTING AND PACKING THE DCU UNIT.............................. 27 R EMOVING THE TRANSMITTER........................................................ 28 DISCONNECTING THE TRANSMITTER............................................... 29 Version 1.0 ElmoTech Ltd DCU & Transmitter Field Installation Manual 4 TRANSMITTER CLEANING INSTRUCTIONS ........................ 31 C LEANING THE TRANSMITTER:........................................................ 31 TRANSMITTER STRAP REPLACEMENT................................ 33 REASONS FOR STRAP REPLACEMENT............................................... 33 E QUIPMENT NEEDED FOR STRAP REPLACEMENT............................. 34 R EPLACING THE TRANSMITTER STRAPS........................................... 34 FCC NOTICES................................................................................. 36 DCU FCC NOTICES........................................................................ 36 DCU C USTOMER INFORMATION...................................................... 37 T RANSMITTER FCC NOTICES.......................................................... 39 ElmoTech Ltd Version 1.0 DCU & Transmitter Field Installation Manual 5 LIST OF FIGURES Figure Page F IGURE 1 IDEAL DCU LOCATION.......................................................... 9 F IGURE 2 DIAGRAMMATIC VIEW OF A DCU........................................ 11 F IGURE 3 CALIBRATING THE TRANSMITTER........................................ 15 F IGURE 4 ATTACHING THE TRANSMITTER........................................... 17 FIGURE 5 PROTRUDING SIDE OF TRANSMITTER DIRECTED UPWARDS... 17 F IGURE 6 MALE\FEMALE CLIPS ATTACHED........................................ 18 F IGURE 7 DISCONNECTING THE TRANSMITTER.................................... 29 Version 1.0 ElmoTech Ltd DCU & Transmitter Field Installation Manual 6 ElmoTech Ltd Version 1.0 THE MONITOR CENTER/ PROBATION AGENCY At the Monitor Center/Probation Agency: 1. Enter the Offender’s data in the monitoring application. This can be done well in advance, even before the actual equipment is allocated and installed. 2. Enter the following equipment data in the monitoring application. • DCU Serial No. - Check that the number entered matches the number on the DCU unit. • Transmitter Serial No. - Check that the number entered matches the number on the Transmitter. The DCU and Transmitter Serial numbers are visible on the back of each unit. DCU & Transmitter Field Installation Manual 7 Version 1.0 ElmoTech Ltd Equipment Check that you have all the required equipment: • DCU unit and power adapter • Transmitter • Electronic key • Locking device • Strap holder • Strap clips (male and female) • Screwdriver (to open a clip if necessary). It is recommended to use a 5 mm flat head screwdriver. It is always advisable to bring an extra set of strap clips to cater for the event in which the first set may be accidentally damaged during the installation. DCU & Transmitter Field Installation Manual 8 ElmoTech Ltd Version 1.0 THE OFFENDER’S PREMISES Monitoring System Location In order to install the Monitoring System, you will need to find the best location for the DCU unit. The ideal place for the DCU unit is in the center of the house, 3 feet off the ground and at least 1 foot away from the wall. Figure 1 Ideal DCU Location DCU & Transmitter Fi…

Text truncated - open the document above for the full version.

Block Diagram

DCU Block Diagram Figure no.1: Main Module Diagram CPU- 68302 RFMMITBD SCI INTERNAL MODEM LAN OR VMU POWER +BATTERY RAM + FLASH MEMOREY RS232 OR RS485 RESET ON POWER MANUAL RESET REAL TIME CLOCK UART A UART B BUILD IN SENSORS CPU INTERNAL BUS S/wr load control Elmo-Tech LTD Ver. 1.01 DCU_Block Diagram 1.1.1 COMMUNICATION OBJECTS  Telephone.  General purpose-s\w load.  RF. Figure no.2: RF Object Diagram RF RF CPU RF RECIVER CPU INTERNAL BUS RSSI DAT Elmo-Tech LTD Ver. 1.01 DCU_Block Diagram  LED’s internal and external.  Buzzer & Siren  Voice.  Relay.  Button’s  Built in sensors. VOICE BUZZER L L L CPU INTERNAL BUS Panic Button Download Tilt &Case Open L SIREN

Cover Letter(s)

TCB Confidentiality Form 18/07/2004 EMCCert DR. RAŠEK Boelwiese 5 91320 Ebermannstadt Germany Tel.: +49-9194-9331 Fax: +49-9194-7964-84 E-mail: [email protected] URL: http://www.emcc.de Gentlemen: This letter is to comply with Section 0.457(d)(2)(i) pertaining to confidential material. Elmo Tech would like the following document regarding this submission for FCC ID: LSQ-DCU-2010C to be kept confidential. Schematics: 1 Page. The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want this document to be accessible to the general public. Sincerely, Gil Gemer VP R&D

ID Label/Location Info

MODEL: DCU 2010C E17028 ALARM DEVICE I.T.E. US: LSQAL10BDCU2010 FCC ID: LSQ-DCU-2010C Elmo-Tech Ltd. E3 CURRENT :1A RATED VOLTAGE :12VDC Made In Israel

ID Label/Location Info

Label Location

Operational Description

ElmoTech Ltd Version 1.0 THE OFFENDER’S PREMISES Monitoring System Location In order to install the Monitoring System, you will need to find the best location for the DCU unit. The ideal place for the DCU unit is in the center of the house, 3 feet off the ground and at least 1 foot away from the wall. Figure 1 Ideal DCU Location DCU & Transmitter Field Installation Manual 9 Version 1.0 ElmoTech Ltd DCU & Transmitter Field Installation Manual 10 The DCU unit should be in an open area away from other electrical appliances (e.g. personal computers, laptops) or any metal objects. Installing the DCU Unit In order to install the DCU unit: 1. Plug the appropriate end of the power adapter cord into the 12VDC socket at the back of the DCU unit. 2. Plug the power adapter into a wall power socket. The DCU unit makes an audible beeping sound and then runs through a series of built-in-tests to check that everything is in order. 3. After completing the tests successfully the DCU unit beeps again and the two external LED’s, located at the rear of the DCU unit, are turned on. This indicates that the DCU unit is in working order. The LED indicators are: • Left LED - indicates that power is connected • Right LED - indicates that the DCU unit has registered to a telephone network (network registration may take up to one minute after built-in- test completion). ElmoTech Ltd Version 1.0 DCU & Transmitter Field Installation Manual 11 Figure 2 Diagrammatic View of a DCU If, at the end of the start-up self test, audible beeping sounds are heard and all three LED’s flash for 10 seconds, it indicates one of the following possible failures: i Case open micro-switch malfunction. i Tilt sensor malfunction. i Range threshold values lost (maximum reception range is used in this case).

Test Report

LSQ-DCU-2010C Test Report REV ∆ Description Sheet Effected Date Drawn Checked A 15.07.04 D.Lanuel S.Cohen EMC Laboratory Data Collection Unit FCCID: LSQ-DCU-2010C Manufactured by Elmotech Ltd. EMC Test Report According FCC Part 15 Requirements January 04 EMC/30020FC04102 7/18/04 1/1 Function/Title Name Signature Date Prepared by Test Engineer D.Lanuel 15.07.04 Checked by Test Engineer D.Lanuel 15.07.04 Approved by EMC Lab. Manager S.Cohen 15.07.04 LSQ-DCU-2010C Test Report Table of Contents Para Page 1 INTRODUCTION....................................................................................................................................3 2 TEST DATA INFORMATION.....................................................................................................................3 3 TEST SUMMARY AND SIGNATURES.........................................................................................................4 4 E.U.T INFORMATION.............................................................................................................................5 5 UNINTENTIONAL RADIATED EMISSION CLASS B TEST ACCORDING TO 15.109..........................................6 6 CONDUCTED EMISSION, AC POWER LEADS ACCORDING TO FCC 15.107.................................................13 EMC/30020FC04102 7/18/04 2/2 LSQ-DCU-2010C Test Report 1 Introduction a. Scope This document describes the measurement procedures and tests for FCC part 15 of the LSQ- DCU-2010C Manufactured by Elmotech Ltd. 2 Test Data Information a. Description of equipment Under Test Equipment Under Test: DCU Cellular FCCID LSQ-DCU-2010C Manufacturer: Elmotech Ltd. Serial Numbers: 031NA10003 Mode of Operation: RX MODE Receiver operating frequency: 318MHZ Year of Manufacture: 2003 b. Applicant Information: Applicant: Elmotech Ltd. Applicant Address 2, Habarzel Street Tel-Aviv Telephone: +972-3-6478871 FAX: +972-3-6478872 The testing was observed by: Natan Galperin following applicant's personnel: c. Test Performance: Date of reception for testing: 05.06.04 Dates of testing 06.06.04 Test Laboratory Location TADIRAN EMC LAB , Hashoftim 26 Holon 58102 ISRAEL Tel: 972-3-5574476 Fax: 972-3-5575320 Applicable EMC Specification: Federal Communication Commission (FCC), Part 15: Radio Frequency Devices, Sections 15.107 & 15.109 EMC/30020FC04102 7/18/04 3/3 LSQ-DCU-2010C Test Report 3 Test Summary and Signatures. TADIRAN EMC Laboratory has completed testing of E.U.T in accordance with the requirements of the FCC Part 15 Regulations for Class B equipment. The E.U.T has been found to comply with the emission requirements of the FCC Part 15 Regulations given below Test Test Description Section Pass/Fail 1 Unintentional Radiated Emission 15.109 Pass 2 Unintentional Conducted Emission 15.107 Pass a. Test performed by: Mr. D. Lanuel Test Engineer b. Test Report prepared by: Mr. D. Lanuel Test Engineer c. Test Report Approved by: Mr. Samuel Cohen EMC Lab. Manager EMC/30020FC04102 7/18/04 4/4 LSQ-DCU-2010C Test Report 4 E.U.T information a. E.U.T description The EUT, DCU-2010C-2, is a data collection unit, which receives data from 433.92MHz alarm transmitters. It provides communication with monitoring center through modem and POTS lines and infrared communication with a computer. The device is a powered via external AC/12VDC adapter, manufactured by Egeston Ltd, model number N2UFSW3. b. E.U.T Test Configuration The E.U.T test configuration is shown in figure bellow AC/DC Adaptor Internal Battery Integral Antenna E.U.T c. E.U.T Mode of Operation description (1) The test was performed to measure emission at RX Mode (2) Operating Voltage 110 V, AC 60Hz EMC/30020FC04102 7/18/04 5/5 LSQ-DCU-2010C Test Report 5 Unintentional Radiated Emission class B test According TO 15.109 E.U.T: LSQ-DCU-2010C S/N 031NA10003 Test Method: ANSI C63.4 Date: 02/06/04 Relative Humidity: 37% Ambient Temperature: 22c Air Pressure: 1042hpa Test Setup: Figure 5f Testing Engineer: D.Lanuel Date 06/06/04 a. General The test was performed to measure Radiated emission at RX Mode b. Test Results Summary & Conclusions The E.U.T was found in compliance with 15.109 Requirements c. Limits of Radiated Interference Field Strength according 15.109 The test unit shall meet the limits of Table 5C for Class B equipment. Table 5c Limits For Class B equipment Frequency Range (MHz) Quasi-peak Limits (dBμV/m) 30 - 88 40 88 - 216 43 216 - 960 46 Above 960 54 EMC/30020FC04102 7/18/04 6/6 LSQ-DCU-2010C Test Report d. Test Instrumentation and Equipment Table 5d Test Instrumentation and Equipment Item Model Manufacturer Next Date Calibration Spectrum Analyzer 8593E HP 31/01/05 Broadband Antenna BTA-L FRANKONIA 10.04.05 Double Ridged Guide Antenna 3105 EMCO 15.03.05 Low Noise Amplifier (0-1GHz) AM-1300-N MITEQ 14.01.05 Low Noise Amplifier (1-2GHz) SMC-09 MITEQ 14.01.05 Low Noise Amplifier (2-6GHz) MWA-02060- 4025 ELISRA 14.01.05 e. Test Procedure (1) Preliminary Test Procedure 1) The EUT was placed on the top of a rotating table 0.8 meters above the ground at a chamber shielded 2) The E.U.T was set 3 meters away from the receiving antenna, which was mounted on the top of a variable-height antenna tower. 3) The Antenna height varied from one meter to 1.8 meters above the ground and the table was rotated 360°to determine the maximum value of the field strength 4) The antenna was set both horizontal and vertical polarization. (2) Final Test Procedure 1) The EUT was tested at open area for each suspected emission, 2) The test procedure was performed according paragraph d. but the Antenna height varied from one meter to four meters above the ground f. Final Test Setup 80cm 3m EUT Turn Table Ant Tower 1-4m Variable Ground Plan Test Receiver Figure 5f Radiated Emission test configuration EMC/30020FC04102 7/18/04 7/7 LSQ-DCU-2010C Test Report Radiated Emission Test EMC/30020FC04102 7/18/04 8/8 LSQ-DCU-2010C Test Report g. Results (1) Preliminary test Results Table 5.g.1 Preliminary Test Results for RX Mode …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Yossi Murciano(Quality Assurance Manager)
[email protected]972-3-7671700Fax: 972-3-7671701

Test Firm

Elbit Systems Land C41Tadiran Ltd.Samuel Cohen
[email protected]97235574476Fax: 97235575320

Technical Specifications

#Rule PartsFrequency RangePower Output
115B318 MHz - 318 MHz-
Confidentiality
Long Term

Other Applications from Attenti

Dual Comm RF Monitoring System - FCC ID LSQ-E4-RF-2 - Attenti
LSQ-E4-RF-2

Dual Comm RF Monitoring System

Sep 02, 2012

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Wrist Tag - FCC ID LSQ-TRXS-860-2 - Attenti
LSQ-TRXS-860-2

Wrist Tag

Nov 13, 2011

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Wrist Tag - FCC ID LSQ-TRXS-860 - Attenti
LSQ-TRXS-860

Wrist Tag

Nov 13, 2011

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Part 15 - Remote Control / Security Device Transceiver - FCC ID LSQTRX900F2 - Attenti
LSQTRX900F2

Part 15 - Remote Control / Security Device Transceiver

Nov 06, 2011

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
2TRACK BASE UNIT 318 MHz - FCC ID LSQ-SBU2000318 - Attenti
LSQ-SBU2000318

2TRACK BASE UNIT 318 MHz

Aug 02, 2011

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver