LSQTRX900F4Tracking Bracelet Unit

Attenti
Tracking Bracelet Unit - FCC ID LSQTRX900F4 - Attenti
Click to zoom

Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
Aug 12, 2010
Application Purpose
Original Equipment
Date of Application
Aug 12, 2010
Equipment Note
Tracking Bracelet Unit
Frequency Range
418.00000000 - 418.00000000
Company
Attenti
Country
Israel

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Installation Manual for bracelet TRX900F-4 July 2010 2 Installation Manual for bracelet unit TRX900F-4 Bracelet To Attach the Bracelet Match the Bracelet serial number on the Bracelet case to the number on the Bracelet serial number in the hardware list in PCE. The ankle transmitter and strap will be shipped unattached. You must insert one end of the strap into the transmitter and push the locking pins into place. Make sure that the locking pins are flush with the case. Measure the strap to the offender’s leg and cut the strap to fit around the offender’s ankle. You should size the strap so that it allows approximately ¼ inch of space between the offender’s leg and the strap to ensure comfort. Once you have the strap attached, push the locking pin through the holes on the bracelet and into the strap until it locks into place 3 Make sure the locking pin is pushed far enough so that the top of the pin is flush with the bracelet case To Remove the Bracelet Cut the strap Using the screwdriver provided, turn the right locking pin counter clockwise and the left locking pin clockwise to remove Lift each side of the pin up from the strap and remove. Slide both ends of the strap out of its channel. Dispose of the strap Clean the bracelet with mild detergent. Rinse, dry, and return to your inventory. 4 FCC Notices The ankle transmitter TRX-900F-4 complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: 1) This device may not cause harmful interference and 2) This device must accept any interference received, including interference that may cause undesired operation. 3) Changes or modifications not expressly approved by Elmo Tech Ltd could void the user’s authority to operate the equipment.

Block Diagram

TRX-900F-4 Block Diagram The following block diagram illustrates the functional areas within the TRX-900F-4 tracking bracelet Unit (FCC ID: LSQTRX900F4). SPI CSn0 GDO0GDO2 MRD comm

Cover Letter(s)

FCC Confidentiality Form 19.7.10 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen, This letter is to comply with Section 0.457(d)(2)(i) and 0.459 pertaining to confidential material. Elmo Tech would like the following documents regarding this submission for FCC ID: LSQTRX900F4 to be kept confidential. • Permanent Confidentiality: Schematics • Short-term Confidentiality (180 days): Installation Manual The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want this document to be accessible to the general public. Sincerely, Gil Gemer CTO

External Photos

TRX-900F-4 external photograph

ID Label/Location Info

Label Location for LSQTRX900F4 Label Location LSQTRX900F4

ID Label/Location Info

SEE NOTE #10 B B 48.53 35 20 AA Replaceable Insert SECTION B-B 2.30 1.31 74.82 21.60 5.91 3.20 60° 48.040 +0.05 2.20 11.87 - 0.05 0 30° 45.640 +0.05 C SECTION A-A 23.21 6.16 18.21 2.50 R 0.30 2° DETAIL C SCALE 5 : 1 SHARP EDGE ALL AROUND PART IS OVER MOLDED ON PCWINDOW SEE NOTE 12 REV.ECO#DESCRIPTIONDATEAPPROVED A00001134FIRST RELEASE29/04/2010Ron B. A01001361Change the bottom engraving07/06/2010RonB 17/06/2010 SCALE 1:1 APPR. DESIGN DRAWN DATE MATERIAL: FINISH: DIMENSIONS ARE IN mm UNLESS OTHERWISE SPECIFIED DO NOT SCALE DRAWING PROJECT: BTX-900F DESCRIPTION: BTX BOTTOM HOUSING REV. A01 DWG. No.: 32000069 U nless otherwise specified TOLERANCES ARE: NAME SIGN D E F C 1234 B A 3215 C D 4678 A B A3 SHEET 1 OF 2 ELECTRONIC MONITORING TECHNOLOGIES 2 Habrzel St.,P.O.Box 13236,Tel Aviv 61132 ,Israel Tel:+972-3-7671700 Fax:+972-3-7671701 E-mail: engineering @ elmotech.com P/N 32000069 Status: REL IlanB DECIMALS ANGLES .0± 0.1 .00 ± 0.05 ± 0.5 ° .000 ± 0.01 See notes See notes NOTES: ====== MATERIAL:1. PC - GE Lexan 141R-21092• PC - 241R• COLOR: PMS COOL GREY 102. GENERAL WALL THICKNESS: 3 mm3. GENERAL DRAFT ANGLES: 1 .4. RADII NOT DIMESIONED: R=0.3 MM.5. SURFACE TEXTURE6. Internal : Technical polish External : FINE EDM MATERIAL GATE AND EJECTOR LOCATIONS : SHOULD BE APPROVED7. BEFORE MOLD CONSTRUCTION. THIS DRAWING IS FOR GENERAL INFO ONLY. 8. USE 3D FILE '32000069' FOR MOULD MAKING.9. DATE AND RECYCLE MARK10. MASS : 18.58Gr11. PART IS OVER MOULDED ON PC WINDOW P/N 3200012112. IlanB IlanBIlanB17/06/2010 17/06/2010RonBRonB D G G F F E VIEW D 7.64 ±0.03 23.38 ±0.03 6.33 ±0.03 H SECTION G-G 11.25 140° 0.70 DETAIL H SCALE 2 : 1 29° I SECTION F-F 2.20 0.70 DETAIL I SCALE 5 : 1 6° 11.46 ±0.02 5.70 ±0.02 2.80 0 + 0.02 1.01 ±0.02 3.20 ±0.02 DETAIL E SCALE 2 : 1 17/06/2010 SCALE 1:1 APPR. DESIGN DRAWN DATE MATERIAL: FINISH: DIMENSIONS ARE IN mm UNLESS OTHERWISE SPECIFIED DO NOT SCALE DRAWING PROJECT: BTX-900F DESCRIPTION: BTX BOTTOM HOUSING REV. A01 DWG. No.: 32000069 U nless otherwise specified TOLERANCES ARE: NAME SIGN D E F C 1234 B A 3215 C D 4678 A B A3 SHEET 2 OF 2 ELECTRONIC MONITORING TECHNOLOGIES 2 Habrzel St.,P.O.Box 13236,Tel Aviv 61132 ,Israel Tel:+972-3-7671700 Fax:+972-3-7671701 E-mail: engineering @ elmotech.com P/N 32000069 Status: REL IlanB DECIMALS ANGLES .0± 0.1 .00 ± 0.05 ± 0.5 ° .000 ± 0.01 See notes See notes RonB IlanB RonB 17/06/2010 17/06/2010 IlanBIlanB

Internal Photos

TRX-900F-4 internal photograph

Operational Description

TRX-900F-4 Bracelet Transceiver Operational Description The TRX-900F-4 is a small ankle worn device designed for offender monitoring applications.. The device comprises a printed circuit board (PCB) that includes a RF transceiver module with an integral antenna and a microcontroller that controls its operation. The TRX-900F-4 has one 418MHz RF channel over which it communicates with its allocated home unit and/or GPS tracking device The unit is powered by an internal 3.6V Lithium Thionyl Chloride battery. The TRX-900F is attached to the ankle of the offender by means of a fiber optic strap. When attached to the offender, the strap is connected in such a way that the optical fiber is facing an IR transmitter on one side and an IR receiver on the other. The IR transmitter sends light signals periodically via the fiber. The reception of these signals by the IR receiver proves the integrity of the strap. When activated, the TRX-900F-4 transmits signals separated by a pseudorandom interval of between 15 and 16 seconds. After each transmission, the TRX-900F listens for an acknowledge signal in order to ascertain whether its home unit/tracking device is within range. If a defined timeout has expired without receiving an acknowledge signal, the TRX-900F-4 activates an internal vibrator so as to warn the offender that they are out of range before a violation event is generated. As per section 15.231(a)(3), being a security and safety of life equipment this device transmits supervision transmissions, including data (e.g. battery ok, strap not cut, etc), to determine the device integrity. The total duration of transmissions does not exceed more than two seconds per hour: 60 minutes X 4 transmissions per minute X 6 mSec (max.) = 1.44 seconds.

Test Report

DATE: 09 August 2010 I.T.L. (PRODUCT TESTING) LTD. FCC Radio Test Report for ElmoTech Ltd. Equipment under test: Tracking Bracelet TRX 900F-4 Written by: _____________________________ D. Shidlowsky, Documentation Approved by: _____________________________ A. Sharabi, Test Engineer Approved by: _____________________________ I. Raz, EMC Laboratory Manager This report must not be reproduced, except in full, without the written permission of I.T.L. (Product Testing) Ltd. This report relates only to items tested. Test Report E97521.01 ElmoTech Ltd. Page 1 of 35 FCC ACC M Ver 1.1 05Mayl 2000 Test Report E97521.01 ElmoTech Ltd. Page 2 of 35 FCC ACC M Ver 1.1 05Mayl 2000 Measurement/Technical Report for ElmoTech Ltd. Tracking Bracelet TRX 900F-4 FCC ID: LSQTRX900F4 This report concerns: Original Grant: x Class I change: Class II change: Equipment type: Part 15 Security/Remote Control Transceiver 47CFR15 Section 15231 (a-d) Measurement procedure used is ANSI C63.4-2003. Application for Certification: prepared by: Gil Gemer Elmo Tech Ltd. 2 Habarzel St. Tel-Aviv, 61131 Israel Tel: +972-3-767-1700 Fax: +972-3-767-1701 e-mail: [email protected] Test Report E97521.01 ElmoTech Ltd. Page 3 of 35 FCC ACC M Ver 1.1 05Mayl 2000 TABLE OF CONTENTS 1. GENERAL INFORMATION ------------------------------------------------------------------------------- 4 1.1 Administrative Information ................................................................................. 4 1.2 List of Accreditations ......................................................................................... 5 1.3 Product Description ........................................................................................... 6 1.4 Test Methodology .............................................................................................. 6 1.5 Test Facility ....................................................................................................... 6 1.6 Measurement Uncertainty ................................................................................. 6 2. SYSTEM TEST CONFIGURATION --------------------------------------------------------------------- 7 2.1 Justification ........................................................................................................ 7 2.2 Special Accessories .......................................................................................... 7 2.3 Equipment Modifications ................................................................................... 7 2.4 Configuration of Tested System ........................................................................ 7 3. RADIATED MEASUREMENT TEST SET-UP PHOTO -------------------------------------------- 8 4. AVERAGE FACTOR CALCULATION ----------------------------------------------------------------- 9 4.1 Test Instrumentation Used .............................................................................. 11 5. PERIODIC OPERATION ---------------------------------------------------------------------------------12 5.1 Specification .................................................................................................... 12 5.2 Requirements .................................................................................................. 12 5.3 Results............................................................................................................. 12 6. FIELD STRENGTH OF FUNDAMENTAL ------------------------------------------------------------15 6.1 Test Specification ............................................................................................ 15 6.2 Test Procedure ................................................................................................ 15 6.3 Measured Data ................................................................................................ 15 6.4 Test Instrumentation Used, Field Strength of Fundamental ........................... 19 7. RADIATED EMISSION, 9 KHZ – 30 MHZ -----------------------------------------------------------20 7.1 Test Specification ............................................................................................ 20 7.2 Test Procedure ................................................................................................ 20 7.3 Measured Data ................................................................................................ 20 7.4 Test Instrumentation Used, Radiated Measurements .................................... 21 7.5 Field Strength Calculation ............................................................................... 21 8. SPURIOUS RADIATED EMISSION -------------------------------------------------------------------22 8.1 Test Specification ............................................................................................ 22 8.2 Test Procedure ................................................................................................ 22 8.3 Test Data ......................................................................................................... 23 8.4 Test Instrumentation Used, Radiated Measurements .................................... 25 9. BANDWIDTH ------------------------------------------------------------------------------------------------26 9.1 Test procedure ................................................................................................ 26 9.2 Results table .................................................................................................... 27 9.3 Test Equipment Used. ..................................................................................... 28 10. APPENDIX A - CORRECTION FACTORS ----------------------------------------------------------29 10.1 Correction factors for CABLE ......................................................................... 29 10.2 Correction factors for CABLE ......................................................................... 30 10.3 Correction factors for CABLE .........................…

Text truncated - open the document above for the full version.

Test Setup Photos

TRX-900F-4 Test Setup Photographs

Contact Information

Applicant

Yossi Murciano(Quality Assurance Manager)
[email protected]972-3-7671700Fax: 972-3-7671701

Test Firm

ITL Product Testing LTDSteli Loznen
[email protected]972-8-9186100Fax: 972 8 9153101

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231418 MHz - 418 MHz-
Confidentiality
Long Term

Other Applications from Attenti

Dual Comm RF Monitoring System - FCC ID LSQ-E4-RF-2 - Attenti
LSQ-E4-RF-2

Dual Comm RF Monitoring System

Sep 02, 2012

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Wrist Tag - FCC ID LSQ-TRXS-860-2 - Attenti
LSQ-TRXS-860-2

Wrist Tag

Nov 13, 2011

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Wrist Tag - FCC ID LSQ-TRXS-860 - Attenti
LSQ-TRXS-860

Wrist Tag

Nov 13, 2011

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Part 15 - Remote Control / Security Device Transceiver - FCC ID LSQTRX900F2 - Attenti
LSQTRX900F2

Part 15 - Remote Control / Security Device Transceiver

Nov 06, 2011

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
2TRACK BASE UNIT 318 MHz - FCC ID LSQ-SBU2000318 - Attenti
LSQ-SBU2000318

2TRACK BASE UNIT 318 MHz

Aug 02, 2011

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver