Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Dec 03, 2015
Application Purpose
Original Equipment
Date of Application
Dec 02, 2015
Equipment Note
PROTO N
Frequency Range
2405.00000000 - 2475.00000000
Company
Estes-Cox Corp. d/b/a Estes Industries
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Proto N Proto N Proto N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N PROTO N Estes-Cox Corp. d/b/a Estes Industries

Cover Letter(s)

SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 5.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (obsolete) 2.0 3.0 Jan-31-2012 Updated letter information (obsolete) 3.0 4.0 May-23-2014 Added FCC ID field (current) 4.0 5.0 Sept 16 2014 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 5.0 Estes-Cox Corp. d/b/a Estes Industries Add: 1295 H Street, Penrose, Colorado 81240 United States Tel: 719-372-6565 ext 224 Fax: 719-372-3419 2015-11-21 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA FCC ID: M45-5103 Dear Sir/Madam, Re: Product Certification Representative Authorization Letter We, Estes-Cox Corp. d/b/a Estes Industries hereby authorize SIEMIC, Inc. to act as a Certification Body for certifying for the following project(s): (Product description, model name): PROTO N , 5103, 5104, 5105, 5106 Sincerely, Client’s name / title : Mary Roberts / Technical Services Contact information / address : 1295 H Street, Penrose, Colorado 81240 United States Tel: 719-372-6565 ext 273 Fax: 719 372-3419 E-Mail: [email protected]

Cover Letter(s)

SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 4.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (obsolete) 2.0 3.0 Jan-31-2012 Added IC confidentiality letter form (current) 3.0 4.0 March-26-2015 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 4.0 Estes-Cox Corp. d/b/a Estes Industries 2015-11-21 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: M45-5103 We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Schematics - Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s name / title : Mary Roberts / Technical Services Contact information / address : 1295 H Street, Penrose, Colorado 81240 United States Tel: 719-372-6565 ext 273 Fax: 719 372-3419 E-Mail: [email protected]

Cover Letter(s)

Estes-Cox Corp. d/b/a Estes Industries Add: 1295 H Street, Penrose, Colorado 81240 United States Tel: 719-372-6565 ext 224 Fax: 719-372-3419 Date: 2015-11-21 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA FCC ID: M45-5103 Dear Sir/Madam, We, Estes-Cox Corp. d/b/a Estes Industries Hereby declares the following statement for SIEMIC, INC, PCB board, circuit, structure and internal of these model(s) are the same, Only color and model number is different for these model: Product name: PROTO N Model no.: 5103, 5104, 5105, 5106 Trade Mark: ESTES Sincerely, Client’s name / title : Mary Roberts / Technical Services Contact information / address : 1295 H Street, Penrose, Colorado 81240 United States Tel: 719-372-6565 ext 273 Fax: 719 372-3419 E-Mail: [email protected]

External Photos

IC:5011A-5103 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:M45-5103 Report No.: LCS1511020069E ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 3 1. EXTERIOR PHOTOGRAPHS Fig.1 Fig.2 IC:5011A-5103 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:M45-5103 Report No.: LCS1511020069E ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 3 Fig.3 Fig.4 IC:5011A-5103 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:M45-5103 Report No.: LCS1511020069E ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 3 of 3 Fig.5 Fig.6

ID Label/Location Info

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD FCC ID:M45-5103 Report No.: LCS1511020069E This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 LABEL AND LOCATION Size:L:3.0cm*W:2.0cm PROTO N Model No.: 5103 FCC ID: M45-5103 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Lable location

Internal Photos

IC:5011A-5103 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:M45-5103 Report No.: LCS1511020069E This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 2 1. INTERIOR PHOTOGRAPHS OF EUT Fig.1 Fig.2 IC:5011A-5103 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:M45-5103 Report No.: LCS1511020069E This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 2 Fig.3 Antenna

RF Exposure Info

IC:5011A-5103 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:M45-5103 Report No.: LCS1511020069E ___________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 2 FCC RF Exposure Exposure category: General population/uncontrolled environment EUT Type: Production Unit Device Type: Portable Device Refer Standard: KDB 447498 D01 General RF Exposure Guidance v05r02 FCC Part 2 §2.1093 Evaluation method According to KDB447498 D01 General RF Exposure Guidance v05r01Section 4.3.1 Standalone SAR test exclusion considerations:“ Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.23 “ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. IC:5011A-5103 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:M45-5103 Report No.: LCS1511020069E ___________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 2 Conducted Power Results Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 00 2405 5.942 40 2445 5.843 70 2475 5.423 Manufacturing tolerance GFSK (Peak) Channel Channel 00 Channel 40 Channel 70 Target (dBm) 5.0 5.0 5.0 Tolerance ±(dB) 1.0 1.0 1.0 Evaluation Results Band/Mode f (GHz) Antenna Distance (mm) RF output power (including tune-up tolerance) SAR Test Exclusion Threshold SAR Test Exclusion dBm mW GFSK 2.445 5 6.0 3.9811 1.245<3.0 Yes Conclusion The measurement results comply with the FCC Limit per 47 CFR 2.1093 for the uncontrolled RF Exposure and SAR Exclusion Threshold per KDB 447498 v05r02. .......................END OF REPORT.........................

Test Report

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:M45-5103 Report No.: LCS1511020069E This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 43 FCC/IC TEST REPORT FOR Estes-Cox Corp. d/b/a Estes Industries PROTO N Model No.: 5103 Additional Model No.: Please refer to page 5. Prepared for : Estes-Cox Corp. d/b/a Estes Industries Address : 1295 H Street, Penrose, Colorado 81240 United States Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : October 27, 2015 Number of tested samples : 1 Serial number : Prototype Date of Test : October 27, 2015 – November 17, 2015 Date of Report : November 17, 2015 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:M45-5103 Report No.: LCS1511020069E This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 43 FCC/IC TEST REPORT FCC CFR 47 PART 15 C(15.247): 2014/ RSS-247, Issue 1: 2015 / RSS-Gen, Issue 4: 2014 Report Reference No. ............... : LCS1511020069E Date of Issue ................................. : November 17, 2015 Testing Laboratory Name .......... : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ......................................... : 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China Testing Location/ Procedure ......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ....................... : Estes-Cox Corp. d/b/a Estes Industries Address ......................................... : 1295 H Street, Penrose, Colorado 81240 United States Test Specification Standard ........................................ : FCC CFR 47 PART 15 C(15.247): 2014 RSS-247, Issue 1:2015 RSS-Gen, Issue 4: 2014 Test Report Form No. ................... : LCSEMC-1.0 TRF Originator ............................. : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. ................ : PROTO N Trade Mark ................................... : ESTES Model/ Type reference .................. : 5103 Ratings .......................................... : DC 6V by battery(600mAh) Result ......................................... : Positive Compiled by: Supervised by: Approved by: Kyle Yin/ File administrators Glin Lu/ Technique principal Gavin Liang/ Manager SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:M45-5103 Report No.: LCS1511020069E This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 3 of 43 FCC/IC -- TEST REPORT Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS1511020069E November 17, 2015 Date of issue Type / Model........................... : 5103 EUT......................................... : PROTO N Applicant............................... : Estes-Cox Corp. d/b/a Estes Industries Address.................................. : 1295 H Street, Penrose, Colorado 81240 United States Telephone............................... : / Fax.......................................... : / Manufacturer........................ : Guangdong Cheerson Hobby Technology Co., Ltd. Address................................... : Fengxin No.2 Road, Fengxin Industrial Zone, Chenghai, Shantou City, Guangdong Province, China Telephone............................... : / Fax.......................................... : / Factory................................... : Guangdong Cheerson Hobby Technology Co., Ltd. Address................................... : Fengxin No.2 Road, Fengxin Industrial Zone, Chenghai, Shantou City, Guangdong Province, China Telephone............................... : / Fax.......................................... : / SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:M45-5103 Report No.: LCS1511020069E This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 4 of 43 TABLE OF CONTENTS Description Page 1. GENERAL INFORMATION ....................................................................................................... 5 1.1 Description of Device (EUT) ................................................................................................................ 5 1.2 Support equipment List .......................................................................................................................... 5 1.3 External I/O Cable .................................................................................................................................. 6 1.4 Description of Test Facility .................................................................................................................... 6 1.5 Statement of The Measurement Uncertainty .......................................................................................... 6 1.6 Measurement Uncertainty.............…

Text truncated - open the document above for the full version.

Test Setup Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:M45-5103 Report No.:LCS1511020069E _______________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 1 TEST SETUP PHOTOGRAPHS 1.Photo of Radiated Measurement Below 1G Above 1G

Contact Information

Applicant

Mary Roberts(Technical Services)
[email protected]719 372-6565Fax: 719 372-3419

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]86-0755-82591330Fax: 86-0755-82591332

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.90 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.

Other Applications from Estes-Cox Corp. d/b/a Estes Industries

2.4G remote controller - FCC ID M45-4611 - Estes-Cox Corp. d/b/a Estes Industries
M45-4611

2.4G remote controller

Jul 27, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Proto X/Syncro - FCC ID M45-46066V1 - Estes-Cox Corp. d/b/a Estes Industries
M45-46066V1

Proto X/Syncro

Dec 29, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Proto X - FCC ID M45-46066 - Estes-Cox Corp. d/b/a Estes Industries
M45-46066

Proto X

Sep 29, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2.4GHz two-channel radio transmitter for use with radio-controlled model airplanes - FCC ID M45-45503 - Estes-Cox Corp. d/b/a Estes Industries
M45-45503

2.4GHz two-channel radio transmitter for use with radio-controlled model airplanes

Jul 24, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
R/C TRANSMITTER - FCC ID M45054064 - Estes-Cox Corp. d/b/a Estes Industries
M45054064

R/C TRANSMITTER

Nov 15, 2005

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter