MJCPERMALOGIIPermalog Logger II

Palmer Environmental Ltd
Permalog Logger II - FCC ID MJCPERMALOGII - Palmer Environmental Ltd
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Apr 25, 2001
Application Purpose
Original Equipment
Date of Application
Apr 25, 2001
Equipment Note
Permalog Logger II
Frequency Range
450.00000000 - 470.00000000
Company
Palmer Environmental Ltd
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Palmer Environmental Ltd. Registered in England. Registration No. 1463016 Thursday, 10 August 2000 Dear Mr. Weise, We, Palmer Environmental, Ty Coch House, Llantarnam Park Way, Cwmbran, NP44 3AW, UK, hereby authorize MIKES BABT Product Service, Ohmstrasse 2 - 4, D99392 Strasskirchen to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. I further certify that the applicant nor any party to the applications is subject to a denial of federal benefits, that includes FCC benefits, pursuant to section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C Section 862. This authorization expires 1 year from now. Yours Sincerely Simon Harris Product Support Manager [email protected] Ty Coch House Llantarnam Park Way Cwmbran NP44 3AW United Kingdom Tel: +44 (0) 1633 489479 Fax: +44 (0) 1633 877857 AGENT AUTHORIZATION LETTER Mr Thomas Weise MIKES BABT Product Services Ohmstrasse 2 - 4 D99392 Strasskirchen Germany

Cover Letter(s)

Palmer Environmental Ltd. Registered in England. Registration No. 1463016 Thursday, 10 August 2000 RE: Request for Confidentiality Applicant: Palmer Environmental, Ty Coch House, Llantarnam Park Way, Cwmbran, NP44 3AW, UK Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying as outlined below: Schematics, PCB Layout, Technical Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant too Rule 0.457(d)(1)(ii), disclosure of this application and all accompanying documentation will not be made before the date of the Grant of this Application. Yours Sincerely Simon Harris Product Support Manager [email protected] Ty Coch House Llantarnam Park Way Cwmbran NP44 3AW United Kingdom Tel: +44 (0) 1633 489479 Fax: +44 (0) 1633 877857 CONFIDENTIALITY REQUEST LETTER Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA

External Photos

Attachment E 1 FCC ID MJCPERMALOGII File-No. T 19663-00 MN MIKES BABT PRODUCT SERVICE GmbH ! Ohmstrasse 2-4 ! D-94342 Strasskirchen ! Tel.:+49 94 24 94 07-0 ! Fax:+49 94 24 94 07-60 Rev.Nr. 8.5 Attachment E 2 FCC ID MJCPERMALOGII File-No. T 19663-00 MN MIKES BABT PRODUCT SERVICE GmbH ! Ohmstrasse 2-4 ! D-94342 Strasskirchen ! Tel.:+49 94 24 94 07-0 ! Fax:+49 94 24 94 07-60 Rev.Nr. 8.5

Internal Photos

Attachment E 3 FCC ID MJCPERMALOGII File-No. T 19663-00 MN MIKES BABT PRODUCT SERVICE GmbH ! Ohmstrasse 2-4 ! D-94342 Strasskirchen ! Tel.:+49 94 24 94 07-0 ! Fax:+49 94 24 94 07-60 Rev.Nr. 8.5 Attachment E 4 FCC ID MJCPERMALOGII File-No. T 19663-00 MN MIKES BABT PRODUCT SERVICE GmbH ! Ohmstrasse 2-4 ! D-94342 Strasskirchen ! Tel.:+49 94 24 94 07-0 ! Fax:+49 94 24 94 07-60 Rev.Nr. 8.5 Attachment E 5 FCC ID MJCPERMALOGII File-No. T 19663-00 MN MIKES BABT PRODUCT SERVICE GmbH ! Ohmstrasse 2-4 ! D-94342 Strasskirchen ! Tel.:+49 94 24 94 07-0 ! Fax:+49 94 24 94 07-60 Rev.Nr. 8.5 Attachment E 6 FCC ID MJCPERMALOGII File-No. T 19663-00 MN MIKES BABT PRODUCT SERVICE GmbH ! Ohmstrasse 2-4 ! D-94342 Strasskirchen ! Tel.:+49 94 24 94 07-0 ! Fax:+49 94 24 94 07-60 Rev.Nr. 8.5

Test Report

FCC ID: MJCPERMALOGII TTI - P-G 009 / 98-00 TTI - P-G 089 / 94-50 File No. T 19663-1-00 MN , Page 1 of 21 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel:+9424-9407-0 Fax:+9424-9407-60 Rev.No. 8.5 E M I S S I O N -- T E S T R E P O R T Testreport file no. :T 19663-1-00 MN ______________ Date : Nov. 06, 2000 of issue _________________ Model : Transmitter for detecting leaks in water distribution systems. ______________________________________________ Type : Permalog Logger II ______________________________________________ Applicant : Palmer environmental Ltd. ______________________________________________ Manufacturer : Palmer environmental Ltd. ______________________________________________ Licence holder : Palmer environmental Ltd. ______________________________________________ Address : TY COCH HOUSE, CWMBRAN ______________________________________________ GWENT, NP44 3AW, UK ______________________________________________ Test result accrdg. to the regulation(s) at page 3 : POSITIV This testreport with appendix consists of 51 pages. The testresult only responds to the tested sample. It is not allowed to copy this report even partly without the allowance of the testlaboratory. File No. T 19663-1-00 MN, Page 2 of 21 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel:+9424-9407-0 Fax:+9424-9407-60 Rev.No. 8.5 D I R E C T O R Y Page A) Documentation Directory2________ Testregulations3________ General information4-5________ Discovery of worst case condition 6________ Equipment under Test20________ Summary21________ B) Testdata Conducted emissions 10/150 kHz - 30 MHz 7________ Spurious emissions (magnetic field) 10 kHz - 30 MHz 8-9 ________ Spurious emissions (electric field) 30 MHz - 1000 MHz 10-11 ________ Spurious emissions (electric field) 1 GHz - 18 GHz 12-13 ________ Raiated power of the fundamental wave 14 ________ Conducted power of the fundamental wave 15 ________ Frequency error16-17________ Keeping the requirements of the emission mask 18-19________ Attachment A) Testdata A1-A18________ B) List of Test EquipmentB1________ C) Photos of the test setup C1-C2________ D) Technical description of the test sample D1-D3 (e.g.CDF, Declaration) ________ E) Photos of the EuTE1-E6________ F) Measurement Protocol for FCC, VCCI and AUSTEL --________ File No. T 19663-1-00 MN, Page 3 of 21 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel:+9424-9407-0 Fax:+9424-9407-60 Rev.No. 8.5 T E S T R E G U L A T I O N S The tests were performed according to following regulations : o - EN 50081-1 / 2.1991 o - EN 50081-2 / 7.1993 -------------------------------------------------------------------------------- o - EN 55011 / 3.1991 o - Group 1 o - Group 2 o - class A o - class B o - EN 55014 / 4.1993 o - Household appliances and similar o - tools o - Semiconductor devices o - EN 55014 / A2:1990 o - EN 55104 / 5.1995 Category: o - EN 55015 / A1:1990 o - EN 55015 / 12.1993 o - EN 55022 / 5.1995 o - class A o - class B o - prEN 55103-1/ 3.1995 o - prEN 50121-3-2 / 3.1995 o - EN 60601-1-2 / 4.1994 o - VCCI o - class 1 o - class 2 !- Part 90 Subpart I (90.217) File No. T 19663-1-00 MN, Page 4 of 21 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel:+9424-9407-0 Fax:+9424-9407-60 Rev.No. 8.5 A D D R E S S O F T H E T E S T L A B O R A T O R Y !-MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D - 94342 Strasskirchen o - ______________________________________ ______________________________________ ______________________________________ E N V I R O N M E N T A L C O N D I T I O N S Temperature: 15-35 ° C______ Humidity 45-60 %______ Atmospheric pressure 860-1060 mbar_________ POWER SUPPLY SYSTEM UTILIZED Power supply system : Battery Unom = 3.6 V DC STATEMENT OF MEASUREMENT UNCERTAINTY The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities that can account for a nominal measurement error of ±4dB. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device. SHORT DESCRIPTION OF THE EQUIPMENT UNDER TEST (EUT) Transmitter for detecting leaks in water distribution systems. The EuT transmits to the receiver 1 KHz to indicates no leak and 2 KHz to indicates Leak. Number of received/tested samples: 1 / 1 DEFINITIONS FOR SYMBOLS USED IN THIS TEST REPORT ! - Black box indicates that the listed condition, standard or equipment is applicable for this Report. o - Blank box indicates that the listed condition, standard or equipment was not applicable for this Report. File No. T 19663-1-00 MN, Page 5 of 21 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel:+9424-9407-0 Fax:+9424-9407-60 Rev.No. 8.5 M E A S U R E M E N T P R O T O C O L F O R F C C , V C C I A N D A U S T E L Test Methodology Conducted and radiated emission testing is performed according to the procedures in International Special Committee on Radio Interference (CISPR) Publication 22 (1993), European Standard EN 55022 and Australian Standard AS 3548 (which are based on CISPR 22). The Japanese standard, "Voluntary Control Council for Interference (VCCI) by Data Processing Equipment and Electronic Office Machines, Technical Requirements" is technically equivalent to CISPR 22 (1993). For official compliance, a conformance report must be sent to and accepted by the VCCI. In compliance with FCC Docket 92-152, "Harmonization of Rules for Digital Devices Incorporate International Standards", testing for FCC compliance may be done following the ANSI C63.4-1992 procedures and using the FCC limits or the CISPR 22 Limits. Measurement Error The test system for conducted emissions is defined as the LISN, tuned receiver and coaxial cable. The test system for spurious emissions is defined as the antenna, the pre-ampli…

Text truncated - open the document above for the full version.

Test Setup Photos

Attachment C1 of C2: Photo documentation: FCC ID: MJCPERMALOGII File No.:T 19663-1-00 MN MIKES BABT PRODUCT SERVICE GmbH ! Ohmstrasse 2-4 ! D-94342 Strasskirchen ! Tel.:+49 94 24 94 07-0 ! Fax:+49 94 24 94 07-60 Rev.Nr. 8.5 Test-Setup: Radiated emission 30 MHz - 1000 MHz (front view) Test-Setup: Radiated emission 30 MHz - 1000 MHz (back view) T 1 9 6 6 3 T 1 9 6 6 3 MN Attachment C2 of C2: Photo documentation: FCC ID: MJCPERMALOGII File No.:T 19663-1-00 MN MIKES BABT PRODUCT SERVICE GmbH ! Ohmstrasse 2-4 ! D-94342 Strasskirchen ! Tel.:+49 94 24 94 07-0 ! Fax:+49 94 24 94 07-60 Rev.Nr. 8.5 Test-Setup: Radiated emission 1000 MHz - 10th harmonic of the fundamental wave (front view) Test-Setup: Radiated emission 1000 MHz - 10th harmonic of the fundamental wave (back view)

Contact Information

Applicant

Dean Aronld
[email protected]44-1633-489479Fax: 44-1633-877857

Test Firm

MIKES BABT Product Service GmbHHarald Buchwald
[email protected]49-9424-9481-150Fax: 49-9424-9481-240

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
190.217(b)450 MHz - 470 MHz1.90 µW6K80F1D2300.0000000000 Hz
Confidentiality
Long Term

Other Applications from Palmer Environmental Ltd

MicroCorr Digital Leak Detector Base Station - FCC ID MJCMCD - Palmer Environmental Ltd
MJCMCD

MicroCorr Digital Leak Detector Base Station

Jan 23, 2005

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
MicroCorr Digital Leak Detector Out-Station - FCC ID MJCMD - Palmer Environmental Ltd
MJCMD

MicroCorr Digital Leak Detector Out-Station

Jan 23, 2005

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Permalog 3 - FCC ID MJCP3 - Palmer Environmental Ltd
MJCP3

Permalog 3

May 12, 2004

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Permalog Logger I - FCC ID MJCPERMALOG - Palmer Environmental Ltd
MJCPERMALOG

Permalog Logger I

Dec 26, 2000

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
MJCPT2

TNB - Licensed Non-Broadcast Station Transmitter

Dec 04, 1995

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter