FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Adomax Technology Co Ltd/
  3. MNLAX-16

MNLAX-16WiFi Display Dongle

Adomax Technology Co Ltd
WiFi Display Dongle - FCC ID MNLAX-16 - Adomax Technology Co Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 29, 2013
Application Purpose
Original Equipment
Date of Application
Sep 29, 2013
Equipment Note
WiFi Display Dongle
Frequency Range
2422.00000000 - 2452.00000000
Company
Adomax Technology Co Ltd
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Parts List/Tune Up Info

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Performance Designed Products, LLC To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Subject: Request for confidentiality FCC ID: MNLAX-16 Dear FCC TCB: 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Tune up Procedure Schematic Block diagram Operational description Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. Sincerely, Tony Yang 2013-09-29

Cover Letter(s)

Adomax Technology Co Ltd Ad Hoc Mode Declaration We, the undersigning company Company Name: Adomax Technology Co Ltd. Address: 5F/2, No. 192, Chung Hsin Road,Section 2, Hsin Tien City, 231, China Hereby confirm that the following products: Product description: WiFi Display Dongle Type designation: AX-16,WFD-02,MDS-3000 Brand: N/A The EUT doesn’t have Ad Hoc Mode function on “non-US frequencies”. In addition, the frequency selection feature is disabled by firmware for devices marketed to the US. For this product, only channels 1~11 will be used in USA. Country code selection is disabled. Signature: Name and title: To n y Ya n g / Engineer

External Photos

Neutron Engineering Inc. Project No.: 1308C215 Page 2 of 7 Neutron Engineering Inc. Project No.: 1308C215 Page 3 of 7

Internal Photos

Neutron Engineering Inc. Project No.: 1308C215 Page 4 of 7 Neutron Engineering Inc. Project No.: 1308C215 Page 5 of 7 Neutron Engineering Inc. Project No.: 1308C215 Page 6 of 7 Neutron Engineering Inc. Project No.: 1308C215 Page 7 of 7 RFmoduleantenna

Parts List/Tune Up Info

Tune up Procedure Subject: Tune up procedure To whom it may concern: FCC ID: MNLAX-16 WiFi Display Dongle requires no adjustment or tune up procedure except factory default setting. The output power setting of EUT is set in the factory and followed the max peak level in below: WiFi 802.11b 2412~2462MHz 6.25±0.5 dBm 802.11g 2412~2462MHz 9.12±0.5 dBm 802.11n20 2412~2462MHz 8.722±0.5 dBm 802.11n40 2422~2452MHz 8.342±0.5 dBm Yours sincerely, Signature: Contact person:Cathy Wang /Neutron Engineering Inc Date: 2013-9-29

RF Exposure Info

Neutron Engineering Inc. FCC RF EXPOSURE REPORT FCC ID: MNLAX-16 Project No. : 1308C215 Equipment : WiFi Display Dongle Model : AX-16; WFD-02; MDS-3000 Applicant : Adomax Technology Co.,LTD Address : 5F/2, No. 192, Chung Hsin Road,Section 2, Hsin Tien City, 231, Taipei Hsien, Taiwan According: : FCC Guidelines for Human Exposure IEEE C95.1 Neutron Engineering Inc. No.3, Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China. TEL : (0769) 8318-3000 FAX : (0769) 8319-6000 Neutron Engineering Inc. GENERAL CONCULUSION: Table for Filed Antenna: Ant. Brand Model Name Antenna Type Connector Gain (dBi) 1 N/A N/A Internal N/A 0.8 Maximum measured transmitter power: Mode Output Power (dBm) Out Power (mW) Limit (mW) B 6.25 4.22 10 G 9.12 8.17 10 N20 8.72 7.45 10 N40 8.34 6.82 10 Maximum peak power specification in the Tune Up Mode Output Power (dBm) Out Power (mW) Limit (mW) B 6.75 4.70 10 G 9.62 9.16 10 N20 9.22 8.36 10 N40 8.84 7.66 10 According to FCC KDB447498 V05, Appendix A, SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤ 50 mm The maximum measured output peak power of this EUT are 6.25dBm (4.22mW B MODE) ,9.12 dBm (8.17mW G MODE), 8.72 dBm (7.45mW N20 MODE), 8.34 dBm (6.82mW N40 MODE), and the maximum power specification of this device are 6.75dBm (4.70mW B MODE) ,9.62dBm (9.16mW G MODE), 9.22 dBm (8.36mW N20 MODE), 8.84 dBm (7.66mW N40 MODE), therefore all of them are less than 10mW at 5mm distance. Conclusion: No SAR evaluation required since transmitter power is below FCC threshold

Test Report

Neutron Engineering Inc. Report No.: NEI-FCCP-1-1308C215 Page 1 of 122 FCC Radio Test Report FCC ID: MNLAX-16 This report concerns (check one): Original Grant Class II Change Issued Date : Sep. 05, 2013 Project No. : 1308C215 Equipment : WiFi Display Dongle Model Name : AX-16; WFD-02; MDS-3000 Applicant : Adomax Technology Co.,LTD. Address : 5F/2,NO.192, Chung Hsin Road, Section2, Hsin Tien Dist., New Taipei City, Taiwan Tested by: Neutron Engineering Inc. EMC Laboratory Date of Receipt: Aug. 23, 2013 Date of Test: Aug. 23, 2013~ Sep. 04, 2013 Testing Engineer : ( David Mao) Technical Manager : (Leo Hung) Authorized Signatory: (Steven Lu) Neutron Engineering Inc. No.3,Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China. TEL: 0769-8318-3000 FAX: 0769-8319-6000 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1308C215 Page 2 of 122 Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C, or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutron shall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Neutron Engineering Inc. Report No.: NEI-FCCP-1-1308C215 Page 3 of 122 Table of Contents Page 1 . CERTIFICATION 5 2 . SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3 . GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 10 3.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 11 3.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 12 3.5 DESCRIPTION OF SUPPORT UNITS 13 4 . EMC EMISSION TEST 14 4.1 CONDUCTED EMISSION MEASUREMENT 14 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 14 4.1.2 MEASUREMENT INSTRUMENTS LIST AND SETTING 14 4.1.3 TEST PROCEDURE 15 4.1.4 DEVIATION FROM TEST STANDARD 15 4.1.5 TEST SETUP 15 4.1.6 EUT OPERATING CONDITIONS 15 4.1.7 TEST RESULTS 16 4.2 RADIATED EMISSION MEASUREMENT 19 4.2.1 RADIATED EMISSION LIMITS 19 4.2.2 MEASUREMENT INSTRUMENTS LIST ANS SETTING 20 4.2.3 TEST PROCEDURE 21 4.2.4 DEVIATION FROM TEST STANDARD 21 4.2.5 TEST SETUP 22 4.2.6 EUT OPERATING CONDITIONS 23 4.2.7 TEST RESULTS (BETWEEN 30 – 1000 MHZ) 24 4.2.8 TEST RESULTS (ABOVE 1000 MHZ) 31 5 . BANDWIDTH TEST 79 5.1 APPLIED PROCEDURES / LIMIT 79 5.1.1 MEASUREMENT INSTRUMENTS LIST 79 5.1.2 TEST PROCEDURE 79 5.1.3 DEVIATION FROM STANDARD 79 5.1.4 TEST SETUP 79 5.1.5 EUT OPERATION CONDITIONS 79 5.1.6 TEST RESULTS 80 6 . MAXIMUM OUTPUT POWER TEST 88 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1308C215 Page 4 of 122 Table of Contents Page 6.1 APPLIED PROCEDURES / LIMIT 88 6.1.1 MEASUREMENT INSTRUMENTS LIST 88 6.1.2 TEST PROCEDURE 88 6.1.3 DEVIATION FROM STANDARD 88 6.1.4 TEST SETUP 88 6.1.5 EUT OPERATION CONDITIONS 88 6.1.6 TEST RESULTS 89 7 . ANTENNA CONDUCTED SPURIOUS EMISSION 91 7.1 APPLIED PROCEDURES / LIMIT 91 7.1.1 MEASUREMENT INSTRUMENTS LIST 91 7.1.2 TEST PROCEDURE 91 7.1.3 DEVIATION FROM STANDARD 91 7.1.4 TEST SETUP 91 7.1.5 EUT OPERATION CONDITIONS 91 7.1.6 TEST RESULTS 92 8 . POWER SPECTRAL DENSITY TEST 112 8.1 APPLIED PROCEDURES / LIMIT 112 8.1.1 MEASUREMENT INSTRUMENTS LIST 112 8.1.2 TEST PROCEDURE 112 8.1.3 DEVIATION FROM STANDARD 112 8.1.4 TEST SETUP 112 8.1.5 EUT OPERATION CONDITIONS 112 8.1.6 TEST RESULTS 113 9 . EUT TEST PHOTO 121 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1308C215 Page 5 of 122 1. CERTIFICATION Equipment : WiFi Display Dongle Brand Name : N/A Model Name : AX-16; WFD-02; MDS-3000 Applicant : Adomax Technology Co.,LTD. Manufacturer : ATEX Electronic Ltd. Address : E Bldg., Xin Hua Industrial Park, Niu Shan, Dong Chen District, Dong Guan Guang Dong Prouince, China Factory : ATEX Electronic Ltd. Address : E Bldg., Xin Hua Industrial Park, Niu Shan, Dong Chen District, Dong Guan Guang Dong Prouince, China Date of Test : Aug. 23, 2013~ Sep. 04, 2013 Test Item : ENGINEERING SAMPLE Standard(s) : FCC Part15(2012), Subpart C(15.247) / ANSI C63.4-2009 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FCCP-1-1308C215) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment standard and technical standard(s). Neutron Engineering Inc. Report No.: NEI-FCCP-1-1308C215 Page 6 of 122 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standard(s): FCC Part15 (15.247) , Subpart C Standard(s) Section Test Item Judgment Remark 15.207 Conducted Emission PASS 15.247(d) Antenna conducted Spurious Emission PASS 15.247(a)(2) 6dB Bandwidth PASS 15.247(b)(3) Peak Output Power PASS 15.247(e) Power Spectral Density PASS 15…

Text truncated - open the document above for the full version.

Test Setup Photos

Neutron Engineering Inc. Report No.: NEI-FCCP-1-1308C215 Page 121 of 122 9. EUT TEST PHOTO Conducted Measurement Photos Neutron Engineering Inc. Report No.: NEI-FCCP-1-1308C215 Page 122 of 122 Radiated Measurement Photos

Contact Information

Applicant

Tony Yang(Engineer)
[email protected]886-2-29160989Fax: 886-2-29110077

Test Firm

BTL Inc.Daisy Dai
[email protected]008676983183000Fax: 0086 769 83196000

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.42 GHz - 2.45 GHz6.83 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. This device must not be co-located or operating in conjunction with any other antenna or transmitter. When operating in 802.11n, 40 MHz mode, the operating frequency segment is limited to 2422 to 2452 MHz respectively.

Other Applications from Adomax Technology Co Ltd

Cordless Portable Mini Optical Mouse - FCC ID MNLAM6500UP - Adomax Technology Co Ltd
MNLAM6500UP

Cordless Portable Mini Optical Mouse

Sep 27, 2005

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RF OPTICAL MOUSE - FCC ID MNL220020040226 - Adomax Technology Co Ltd
MNL220020040226

RF OPTICAL MOUSE

Mar 11, 2004

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless Mouse - FCC ID MNL160020021025 - Adomax Technology Co Ltd
MNL160020021025

Wireless Mouse

Mar 05, 2003

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless Mouse - FCC ID MNLAM160020021025 - Adomax Technology Co Ltd
MNLAM160020021025

Wireless Mouse

Jan 26, 2003

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless Mouse - FCC ID MNL98929110077 - Adomax Technology Co Ltd
MNL98929110077

Wireless Mouse

Jan 19, 2003

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter