MOZB3V2L2LSmart Key Box

Tokai Rika Co Ltd
Smart Key Box - FCC ID MOZB3V2L2L - Tokai Rika Co Ltd
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jan 12, 2021
Application Purpose
Original Equipment
Date of Application
Jan 12, 2021
Equipment Note
Smart Key Box
Frequency Range
312.10000000 - 312.10000000
Company
Tokai Rika Co Ltd
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

For vehicles sold in U.S.A.: NOTE This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. For vehicles sold in Canada: NOTE This device complies with Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : 1) l'appareil ne doit pas produire de brouillage; 2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Note: We will not supply the user’s manual because our product (B3V2L2L) is one of the vehicle parts. However, we will ask the vehicle manufacturer to include the above statements in the vehicle user’s manual in accordance FCC & IC requirements. Smart Key Box Model B3V2L2L FCC ID: MOZB3R2L2L IC: 2584A-B3V2L2L

External Photos

Exterior Photographs Front View Reverse View Bottom View Top View Smart Key Box Model B3V2L2L FCC ID: MOZB3V2L2L IC: 2584A-B3V2L2L Side View Side View

ID Label/Location Info

Approval Marking Original NOTE: Design, shape, and/or color may be changed. This device will be installed inside vehicle and end-user will not see the mark. FCC compliance statement will be included in User Manual as it is not practical to place on the device according to FCC Rules §15.19. SCALE : FREE Smart Key Box Model: B3V2L2L FCC ID: MOZB3V2L2L IC: 2584A-B3V2L2L Model: B3V2L2L FCC ID: MOZB3V2L2L Contains FCC ID: VIYHRM3012 IC: 2584A-B3V2L2L Contains IC: 7305A-HRM3012

Internal Photos

Front View Reverse View Interior Photographs UHF ANTTENA(TX) LF ANTTENA(RX)

Test Report

Test report No. : 13561032H-A Page : 1 of 23 Issued date : December 8, 2020 FCC ID : MOZB3V2L2L UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Report Cover Page - 13-EM-F0429 Issue # 17.0 RADIO TEST REPORT Test Report No. : 13561032H-A Applicant : TOKAI RIKA CO., LTD. Type of EUT : Smart Key Box Model Number of EUT : B3V2L2L FCC ID : MOZB3V2L2L Test regulation : FCC Part 15 Subpart C: 2020 Test Result : Complied (Refer to SECTION 3.2) 1. This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc. 2. The results in this report appl y only to the sample tested. 3. This sample tested is in compliance with the limits of the above re gulation. 4. The test results in this test report are traceable to the national or international standards. 5. This test report must not be used by the customer to claim product certification, approval, or endorsement by the A2LA accreditation bod y. 6. This test report covers Radio technical requirements. It does not cover administrative issues such as Manual or non-Radio test related Requirements. (if applicable) 7. The all test items in this test report are conducted b y UL Japan, Inc. Ise EMC Lab. 8. The opinions and the interpretations to the result of the description in this report are outside scopes where UL Japan has been accredited. 9. The information provided from the customer for this report is identified in Section 1. Date of test: November 19 and 27, 2020 Representative test engineer: Akihiko Maeda Engineer Consumer Technology Division Approved by: Shinichi Miyazono Engineer Consumer Technology Division CERTIFICATE 5107.02 The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan. There is no testing item of "Non-accreditation". Test report No. : 13561032H-A Page : 2 of 23 Issued date : December 8, 2020 FCC ID : MOZB3V2L2L UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 REVISION HISTORY Original Test Report No.: 13561032H-A Revision Test report No. Date Page revised Contents - (Ori ginal) 13561032H-A December 8, 2020 - - Test report No. : 13561032H-A Page : 3 of 23 Issued date : December 8, 2020 FCC ID : MOZB3V2L2L UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Reference: Abbreviations (Including words undescribed in this report) A2LA The American Association for Laboratory Accreditation MCS Modulation and Coding Scheme AC Alternating Current MRA Mutual Recognition Arrangement AFH Adaptive Frequency Hopping N/A Not Applicable AM Amplitude Modulation NIST National Institute of Standards and Technology Amp, AMP Amplifier NS No signal detect. ANSI American National Standards Institute NSA Normalized Site Attenuation Ant, ANT Antenna NVLAP National Voluntary Laboratory Accreditation Program AP Access Point OBW Occupied Band Width ASK Amplitude Shift Keying OFDM Orthogonal Frequency Division Multiplexing Atten., ATT Attenuator P/M Power meter AV Average PCB Printed Circuit Board BPSK Binary Phase-Shift Keying PER Packet Error Rate BR Bluetooth Basic Rate PHY Physical Layer BT Bluetooth PK Peak BT LE Bluetooth Low Energy PN Pseudo random Noise BW BandWidth PRBS Pseudo-Random Bit Sequence Cal Int Calibration Interval PSD Power Spectral Density CCK Complementary Code Keying QAM Quadrature Amplitude Modulation Ch., CH Channel QP Quasi-Peak CISPR Comite International Special des Perturbations Radioelectriques QPSK Quadri-Phase Shift Keying CW Continuous Wave RBW Resolution Band Width DBPSK Differential BPSK RDS Radio Data System DC Direct Current RE Radio Equipment D-factor Distance factor RF Radio Frequency DFS Dynamic Frequency Selection RMS Root Mean Square DQPSK Differential QPSK RSS Radio Standards Specifications DSSS Direct Sequence Spread Spectrum Rx Receiving EDR Enhanced Data Rate SA, S/A Spectrum Analyzer EIRP, e.i.r.p. Equivalent Isotropically Radiated Power SG Signal Generator EMC ElectroMagnetic Compatibility SVSWR Site-Voltage Standing Wave Ratio EMI ElectroMagnetic Interference TR Test Receiver EN European Norm Tx Transmitting ERP, e.r.p. Effective Radiated Power VBW Video BandWidth EU European Union Vert. Vertical EUT Equipment Under Test WLAN Wireless LAN Fac. Factor FCC Federal Communications Commission FHSS Frequency Hopping Spread Spectrum FM Frequency Modulation Freq. Frequency FSK Frequency Shift Keying GFSK Gaussian Frequency-Shift Keying GNSS Global Navigation Satellite System GPS Global Positioning System Hori. Horizontal ICES Interference-Causing Equipment Standard IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IF Intermediate Frequency ILAC International Laboratory Accreditation Conference ISED Innovation, Science and Economic Development Canada ISO International Organization for Standardization JAB Japan Accreditation Board LAN Local Area Network LIMS Laboratory Information Management System Test report No. : 13561032H-A Page : 4 of 23 Issued date : December 8, 2020 FCC ID : MOZB3V2L2L UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 CONTENTS PAGE SECTION 1: Customer information ......................................................................................................... 5 SECTION 2: Equipment under test (EUT) .............................................................................................. 5 SECTION 3: Test specification, procedures & results ............................................................................ 6 SECTION 4: Operation of EUT during testing ....................................................................................... 9 SECTION 5: Radiated emission (Electric Field Strength of Fundamental…

Text truncated - open the document above for the full version.

Test Setup Photos

Test report No. : 13561032H-A Page : 21 of 23 Issued date : December 8, 2020 FCC ID : MOZB3V2L2L UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 APPENDIX 3: Photographs of test setup Radiated emission (Below 1GHz) Photo 1 Photo 2 Test report No. : 13561032H-A Page : 22 of 23 Issued date : December 8, 2020 FCC ID : MOZB3V2L2L UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Radiated emission (Above 1GHz) Photo 1 Photo 2 Test report No. : 13561032H-A Page : 23 of 23 Issued date : December 8, 2020 FCC ID : MOZB3V2L2L UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Worst case position Below 1 GHz: (Horizontal: X-axis / Vertical: Z-axis) Above 1 GHz: (Horizontal: X-axis / Vertical: Y-axis) X-axis Y-axis Z-axis End of Report

Contact Information

Applicant

Hiroki Unno
[email protected]+81-587-95-0093Fax: +81-587-95-5471

Technical Contact

UL Japan, Inc.Shinichi Miyazono
[email protected]81-596-24-8999

4383-326 Asama-cho, Ise-shi · Mie-ken · Japan

Test Firm

UL Japan, Inc.(Ise)Takayuki Shimada
[email protected]81-596-24-8999Fax: 81-596-24-8999

Technical Specifications

#Rule PartsFrequency RangePower Output
215.231312.1 MHz - 312.1 MHz-
Confidentiality
Long Term

Other Applications from Tokai Rika Co Ltd

MOZB4P2A2A

RKE Transmitter

Apr 16, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Receiver - FCC ID MOZGK2LG - Tokai Rika Co Ltd
MOZGK2LG

Receiver

Jul 08, 2021

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
RKE Transmitter - FCC ID MOZB3W2F2L - Tokai Rika Co Ltd
MOZB3W2F2L

RKE Transmitter

Jun 01, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
RECEIVER - FCC ID MOZBG3AW - Tokai Rika Co Ltd
MOZBG3AW

RECEIVER

Jan 27, 2016

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
Electronic Key - FCC ID MOZBR1ET - Tokai Rika Co Ltd
MOZBR1ET

Electronic Key

Dec 19, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter