FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Schrader Electronics/
  3. MRXATFPG4

MRXATFPG4TPMS Transmitter

Schrader Electronics
TPMS Transmitter - FCC ID MRXATFPG4 - Schrader Electronics
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jun 16, 2020
Application Purpose
Original Equipment
Date of Application
Jun 16, 2020
Equipment Note
TPMS Transmitter
Frequency Range
433.92000000 - 433.92000000
Company
Schrader Electronics
Country
Ireland

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

The device under test is manufactured by the grantee (Schrader Electronics) and sold as an OEM product. Per 47 CFR 2.909, 2.927, 2.931, 2.1033, 15.15(b) etc..., the grantee must ensure the end-user has all applicable / appropriate operating instructions. When end-user instructions are required, as in the case of this product, the grantee must notify the OEM to notify the end- user. Schrader Electronics will supply this document to the reseller/distributor dictating what must be included in the end user’s manual for the commercial product. INFORMATION TO BE INCLUDED IN THE END USER'S MANUAL The following information (in blue) must be included in the end product user’s manual to ensure continued FCC and Industry Canada regulatory compliance. The ID numbers must be included in the manual if the device label is not readily accessible to the end user. The compliance paragraphs below must be included in the user's manual. ****************************************************************************** (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. FCC ID:MRXATFPG4 IC: 2546A- ATFPG4 This device complies with Part 15 of the FCC Rules and with Licence exempt RSS standards of Industry Canada. Operation is subject to the following two conditions: WARNING: Changes or modifications not expressively approved by the party responsible for compliance could void the user's authority to operate the equipment. The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. ******************************************************************************

Cover Letter(s)

Willow Run (WR) Test Labs, Inc. 7117 Fieldcrest Dr., Brighton, Michigan 48116 USA Tel: (734) 252-9785, Fax: (734) 926-9785, e-mail: [email protected] Re: Certification for Schrader Electronics FCC ID: MRXATFPG4 IC: 2456A-ATFPG4 REQUEST FOR CONFIDENTIALITY Pursuant to USA FCC 47 CFR 0.457(d) and 0.459 and Canada IC RSP-100, Section 10, Schrader Electronicsrequests that a part of the subject application be held confidential. Schrader Electronics has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to ”competition” would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. ExhibitConf. TypeRational Exh 04 - Block DiagramPermanentIncludes proprietary internal oscillator information. Exh 05 - SchematicsPermanentIncludes proprietary design information Exh 10 - BOM + PlacementPermanentIncludes proprietary design information KDB 726920 II3c1: Images Manuf. proprietary and QS controlled. Exh 12 - Modes of OperationPermanentIncludes proprietary design information Short-Term Confidentiality (FCC Only):Schrader Electronics requests that any exhibits selected above as short term confidential be withheld from public view for a period of days (noted above) from the date of the Grant of Equipment Authorization and prior to marketing. If there are any questions regarding the application or testing performed, please contact us at the above address or call (734) 252-9785, or e-mail [email protected]. Sincerely, Joseph D. Brunett Willow Run (WR) Test Labs, Inc. 9 KDB 726920 II3a1: Perm. Epoxy filled, not user accessible. Exh 09 - Internal PhotosPermanent Permanent Confidentiality:Schrader Electronics requests that any exhibits listed above as permanently confidential be permanently withheld from public review. (Applies only to FCC if ISED does not permit.)

ID Label/Location Info

http://www.tpmseuroshop.com/documents/declaration_conformities Schrader Electronics Ltd Unit 11 Technology Park Belfast Road Antrim, Northern Ireland, BT41 1QS

RF Exposure Info

DTNA GEN2 TRUCK GEN6 EZ PAL WAL TX 433 COMPLIANT PIN 70803106227 RF report DOCUMENT NUMBER: NG23092019 ISSUE LEVEL: 03 2.2. BOM (Ref: 90818106229-RF section updated 04062019) DTNA GEN2 TRUCK GEN6 EZ PAL WAL TX 433 COMPLIANT PIN 70803106227 RF report DOCUMENT NUMBER: NG23092019 ISSUE LEVEL: 03

Test Report

Amber Helm Development L.C. 92723 Michigan Hwy-152 Sister Lakes, Michigan 49047 USA Tel: 888-847-8027 EMC Test Report ATFPG4-WR2009TX Issued:May 31, 2020 regarding USA: CFR Title 47, Part 15.231(Emissions) Canada: ISED RSS-210v10/GENv5(Emissions) for ATFPG4 Category: TPMS Transmitter Judgments: 15.231e/RSS-210v10 Compliant Transmitter Testing Completed: May 20, 2020 TESTING NVLAP LAB CODE 200129-0 Prepared for: Schrader Electronics 11 Technology Park, Belfast Road, Antrim Northern Ireland BT41 1QS United Kingdom Phone: +44 28 9448 3067, Fax: +44 28 9446 8440 Contact: James Kyle, [email protected] Data Recorded by: Reviewed by: Dr. Joseph Brunett, EMC-002790-NEGordon Helm, EMC-002401-NE Prepared by:Date of Issue: May 31, 2020 Dr. Joseph Brunett, EMC-002790-NE A copy of this report will remain on file until June 2030.Page 1 of 17 Date: May 31, 2020Prepared For: Schrader ElectronicsReport No.: ATFPG4-WR2009TX Revision History Rev. No.DateDetailsRevised By r0May 31, 2020Initial Release.J. Brunett Contents Revision History2 Table of Contents2 1 Test Report Scope and Limitations4 1.1 Laboratory Authorization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.2 Report Retention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.3 Subcontracted Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.4 Test Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.5 Limitation of Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.6 Copyright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.7 Endorsements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.8 Test Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 1.9 Traceability and Equipment Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 2 Test Specifications and Procedures6 2.1 Test Specification and General Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 3 Configuration and Identification of the Equipment Under Test7 3.1 Description and Declarations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 3.1.1EUT Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.2Modes of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.3Variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.4Test Samples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.5Functional Exerciser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.6Modifications Made . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.7Production Intent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3.1.8Declared Exemptions and Additional Product Notes . . . . . . . . . . . . . . . . . . . . . . . .8 4 Emissions9 4.1 General Test Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 4.1.1Radiated Test Setup and Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 4.1.2Conducted Emissions Test Setup and Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . 11 4.1.3Power Supply Variation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 4.2 Intentional Emissions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 4.2.1Fundamental Emission Pulsed Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 4.2.2Fundamental Emission Bandwidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 4.2.3Fundamental Emission Field Strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 4.3 Unintentional Emissions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 4.3.1Transmit Chain Spurious Emissions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 5 Measurement Uncertainty and Accreditation Documents17 Amber Helm Development L.C., 92723 Michigan Hwy-152, Sister Lakes, Michigan 49047 USAPage 2 of 17 Date: May 31, 2020Prepared For: Schrader ElectronicsReport No.: ATFPG4-WR2009TX List of Tables 1Test Site List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 2Equipment List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 3EUT Declarations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 4Fundamental Emission Pulsed Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 5Fundamental Emission Bandwidth.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 6Fundamental Emission Field Strength.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 7Transmit Chain Spurious Emissions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 8Measurement Uncertainty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 List of Figures 1Photos of EUT.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 2EUT Test Configuration Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 3Radiated Emissions Diagram of the EUT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 4Radiated Emi…

Text truncated - open the document above for the full version.

Contact Information

Applicant

James Kyle
[email protected]+44 (0) 28 9448 3073Fax: +44 (0) 28 9446 8440

Technical Contact

Amber Helm Development, LCJoseph D. Brunett
[email protected]888-847-8027

3615 East Grand River Road · Williamston, Michigan · United States

Test Firm

AHD (Amber Helm Development, L.C.)Gordon Helm
[email protected]269-429-8352

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231(e)433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from Schrader Electronics

Tyre Pressure Monitor - FCC ID MRXFTMS01 - Schrader Electronics
MRXFTMS01

Tyre Pressure Monitor

Apr 17, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Tyre Pressure Monitoring Sensor - FCC ID MRXBG6FD4 - Schrader Electronics
MRXBG6FD4

Tyre Pressure Monitoring Sensor

Jun 27, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
TPMS Sensor - FCC ID MRXBBFPL4 - Schrader Electronics
MRXBBFPL4

TPMS Sensor

Mar 26, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Tyre Pressure Monitoring System - FCC ID MRXSCHEB - Schrader Electronics
MRXSCHEB

Tyre Pressure Monitoring System

Jan 25, 2023

Equipment Class

DTS - Digital Transmission System
Tyre Pressure Monitor - FCC ID MRXFP4 - Schrader Electronics
MRXFP4

Tyre Pressure Monitor

Aug 30, 2022

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter