INTRODUCTION The 9OOMHz Stereo Wireless Pocket Receiver uses latest wireless technology that enables you to enjoy music and TV sound anywhere inside or outside your home. This Pocket Receiver with stereo earphone set works with any of our 9OOMHz Wireless Transmitters for headphones or speaker systems.Please contact your dealer for such 9OOMHz Transmitters. FEATURES 1.900 MHz RF technology. 2. RF technology lets you roam freely throughout your house. 3. Operating distance up to 50 Meters. 4. No line-of-sight limitation. 5. Rechargeable function for optional use with 2AA size rechargeable battery. 6. Virtually interference free stereo quality. 7. Hanging string for easy carrying. TRANSMI’I-IER Please use any of our Transmitters for our 900 MHz Headphones or Speaker Systems. (You may contact your dealer for the Transmitter) POCKET RECEIVER TUNE CONTROL L\ EAR PHONE STEREO NDICATOR JACK I!!-- VOLUME CONTROL ON/OFF SWITCH CHARGE INPUT 1
• The test results reported in this report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be said to have been obtained. • This report shall not be reproduced except in full without prior authorization from Intertek Testing Services Hong Kong Limited FCC ID : MVARS942-001R Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Uni-Art Precise Products Ltd. Application For Certification (FCC ID: MVARS942-001R) Superheterodyne Receiver WO# 9910057 DY/sa January 5, 2000 INTERTEK TESTING SERVICES FCC ID : MVARS942-001R i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1:General Description EXHIBIT 2:System Test Configuration EXHIBIT 3:Emission Results EXHIBIT 4:Equipment Photographs EXHIBIT 5:Product Labelling EXHIBIT 6:Technical Specifications EXHIBIT 7:Instruction Manual EXHIBIT 8:Miscellaneous Information INTERTEK TESTING SERVICES FCC ID : MVARS942-001R ii MEASUREMENT/TECHNICAL REPORT Uni-Art Precise Products Ltd. - MODEL: ARKON RS942 FCC ID: MVARS942-001R January 5, 2000 This report concerns (check one:)Original Grant X Class II Change Equipment Type: Superheterodyne Receiver(example: computer, printer, modem, etc.) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?Yes No X If yes, defer until: Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37?Yes No X If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [10-1-96 Edition] provision. Report prepared by:Daniel Yau Intertek Testing Services 2/F., Garment Center, 576, Castle Peak Road, Hong Kong. Phone: 852-2173-8542 Fax:852-2371-0914 INTERTEK TESTING SERVICES FCC ID : MVARS942-001R iii Table of Contents 1.0 General Description................................................................................................................. 2 1.1 Product Description.............................................................................................................. 2 1.2 Related Submittal(s) Grants .................................................................................................2 1.3 Test Methodology ................................................................................................................ 3 1.4 Test Facility.......................................................................................................................... 3 2.0 System Test Configuration...................................................................................................... 5 2.1 Justification .......................................................................................................................... 5 2.2 EUT Exercising Software.....................................................................................................5 2.3 Special Accessories.............................................................................................................. 5 2.4 Equipment Modification ......................................................................................................6 2.5 Support Equipment List and Description.............................................................................. 6 3.0 Emission Results....................................................................................................................... 8 3.1 Field Strength Calculation .................................................................................................... 9 3.1 Field Strength Calculation (cont’d) .................................................................................... 10 3.2 Radiated Emission Configuration Photograph.................................................................... 11 3.3 Radiated Emission Data .....................................................................................................12 4.0 Equipment Photographs........................................................................................................ 15 5.0 Product Labelling................................................................................................................... 17 6.0 Technical Specifications......................................................................................................... 19 7.0 Instruction Manual................................................................................................................ 21 8.0 Miscellaneous Information.................................................................................................... 23 8.1 Discussion of Pulse Desensitization ................................................................................... 24 8.2 Calculation of Average Factor............................................................................................ 25 8.3 Emissions Test Procedures ................................................................................................. 26 8.3 Emissions Test Procedures (cont'd) .................................................................................... 27 INTERTEK TESTING SERVICES FCC ID : MVARS942-001R iv List of attached file Exhibit typeFile Descriptionfilename Cover LetterLetter of Agencyletter.pdf Test ReportTest Reportreport.doc Operation DescriptionTechnical Descriptiondescri.pdf Test Setup PhotoRadiated Emissionradiated1.jpg, radiated2.jpg External PhotoExternal Photoophoto1.jpg, ophoto2.jpg Internal PhotoInternal Photo iphoto1.jpg, iphoto2.jpg and iphoto3.jpg Block DiagramBlock Diagramblock.pdf SchematicsCircuit Diagramcircuit.pdf ID Label/LocationLabel Artwork and Locationlabel.pdf User ManualUser Manualmanual.pdf INTERTEK TESTING SERVICES FCC ID : MVARS942-001R1 EXHIBIT 1 GENERAL DESCRIPTION INTERTEK TESTING SERVICES FCC ID : MVARS942-001R2 1.0General Description 1.1Product Description The equipment u…
Text truncated - open the document above for the full version.
2/F., Garment Centre, · Kowloon · Hong Kong
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 911.5 MHz - 913.5 MHz | - |

2.4 GHz Digital Headphone (Base)
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Headset
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
900MHz Wireless Headphone
Equipment Class
CSR - Scanning Receiver
900MHz Wireless Headphone
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Bluetooth Headset
Equipment Class