Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
PSR-78-9533-NB FCC/IC Label
TEST REPORT FCC MPE Test for PSR-78-9533-NB Certification APPLICANT ADRF KOREA, Inc. REPORT NO. HCT-RF-2602-FC003 DATE OF ISSUE February 10, 2026 Tested by Jae hyeon Chu Technical Manager Jong Seok Lee F-TP22-03(Rev.06) 1 / 9 The report shall not be (partly) reproduced except in full without approval of the laboratory. HCT CO., LTD.2-6, 73, 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea Tel. +82 31 645 6300 Fax. +82 31 645 6401 The report shall not be (partly) reproduced except in full without approval of the laboratory. F-TP22-03 (Rev. 06) Page 2 of 9 HCT CO.,LTD. 2-6, 73, 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea Tel. +82 31 645 6300 Fax. +82 31 645 6401 TEST REPORT REPORT NO. HCT-RF-2602-FC003 DATE OF ISSUE February 10, 2026 A pplicantADRF KOREA, Inc. 196-16 IYEO-RO BAEKSA-MYEON ICHEON-SI, GYEONGGI-DO, 17316, KOREA Product Name Model Name Public Safety Repeater PSR-78-9533-NB FCC IDN52-PSR-78-NB Date of TestDecember 2, 2026 ~ February 10, 2026 Location of TestӍ Permanent Testing Lab ӎ On Site Testing (Address: 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi- do, Republic of Korea) Test Standard UsedCFR 47 Part 2.1091 Test ResultsPASS The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC003 F-TP22-03 (Rev. 06) Page 3 of 9 REVISION HISTORY The revision history for this test report is shown in table. Revision No. Date of Issue Description 0 February 10, 2026 Initial Release Notice Content Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules under normal use and maintenance. The results shown in this test report only apply to the sample(s), as received, provided by the applicant, unless otherwise stated. The test results have only been applied with the test methods required by the standard(s). The laboratory is not accredited for the test results marked *. Information provided by the applicant is marked **. Test results provided by external providers are marked ***. When confirmation of authenticity of this test report is required, please contact www.hct.co.kr The test results in this test report are not associated with the ((KS Q) ISO/IEC 17025) accreditation by KOLAS (Korea Laboratory Accreditation Scheme) / A2LA (American Association for Laboratory Accreditation) that are under the ILAC (International Laboratory Accreditation Cooperation) Mutual Recognition Agreement (MRA). The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC003 F-TP22-03 (Rev. 06) Page 4 of 9 RF Exposure Statement 1. LIMITS According to §1.1310 and §2.1091 RF exposure is calculated. (B) Limits for General Population/Uncontrolled Exposures Frequency range (MHz) Electric field Strength (V/m) Magnetic field Strength (A/m) Power density (mW/cm²) Averaging time (minutes) 0.3 - 1.34 1.34 - 30 30 - 300 300 - 1500 1500 - 100.000 614 824/f 27.5 1.63 2.19/f 0.073 #) (100) #) (180/f²) 0.2 f/1500 1.0 30 30 30 30 30 F = frequency in MHz # = Plane-wave equivalent power density 2. MAXIMUM PERMISSIBLE EXPOSURE Prediction Prediction of MPE limit at a given distance S = PG/4πR² S = Power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC003 F-TP22-03 (Rev. 06) Page 5 of 9 3. RESULTS [Uplink] - Public Safety Narrowband Maximum output Power at antenna input terminal 30.50 dBm Maximum output Power at antenna input terminal 1 122.02 mW Prediction distance 70.00 cm Prediction frequency 799.00 MHz Antenna Gain(typical) 8.65 dBi Antenna Gain(numeric) 7.33 - Power density at prediction frequency(S) 0.1335 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.5327 mW/cm 2 - NPSPAC Maximum output Power at antenna input terminal 30.50 dBm Maximum output Power at antenna input terminal 1 122.02 mW Prediction distance 70.00 cm Prediction frequency 806.00 MHz Antenna Gain(typical) 8.65 dBi Antenna Gain(numeric) 7.33 - Power density at prediction frequency(S) 0.1335 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.5373 mW/cm 2 The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC003 F-TP22-03 (Rev. 06) Page 6 of 9 - B/ILT; SMR Maximum output Power at antenna input terminal 30.50 dBm Maximum output Power at antenna input terminal 1 122.02 mW Prediction distance 70.00 cm Prediction frequency 809.00 MHz Antenna Gain(typical) 8.65 dBi Antenna Gain(numeric) 7.33 - Power density at prediction frequency(S) 0.1335 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.5393 mW/cm 2 - ESMR Maximum output Power at antenna input terminal 30.50 dBm Maximum output Power at antenna input terminal 1 122.02 mW Prediction distance 70.00 cm Prediction frequency 817.00 MHz Antenna Gain(typical) 8.65 dBi Antenna Gain(numeric) 7.33 - Power density at prediction frequency(S) 0.1335 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.5447 mW/cm 2 The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC003 F-TP22-03 (Rev. 06) Page 7 of 9 [Downlink] - Public Safety Narrowband Maximum output Power …
Text truncated - open the document above for the full version.
TEST REPORT FCC Test for PSR-78-9533-NB Certification APPLICANT ADRF KOREA, Inc. REPORT NO. HCT-RF-2602-FC004-R1 DATE OF ISSUE February 20, 2026 Tested by Jae hyeon Chu Technical Manager Jong Seok Lee F-TP22-03(Rev.06) 1 / 216 The report shall not be (partly) reproduced except in full without approval of the laboratory. HCT CO., LTD.2-6, 73, 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea Tel. +82 31 645 6300 Fax. +82 31 645 6401 The report shall not be (partly) reproduced except in full without approval of the laboratory. F-TP22-03 (Rev. 06) Page 2 of 216 HCT CO.,LTD. 2-6, 73, 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea Tel. +82 31 645 6300 Fax. +82 31 645 6401 TEST REPORT REPORT NO. HCT-RF-2602-FC004-R1 DATE OF ISSUE February 20, 2026 A pplicantADRF KOREA, Inc. 196-16 IYEO-RO BAEKSA-MYEON ICHEON-SI, GYEONGGI-DO, 17316, KOREA Product Name Model Name Public Safety Repeater PSR-78-9533-NB FCC IDN52-PSR-78-NB Date of TestDecember 2, 2026 ~ February 20, 2026 Location of TestӍ Permanent Testing Lab ӎ On Site Testing (Address: 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi- do, Republic of Korea) Test Standard UsedCFR 47 Part 90 Test ResultsPASS The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 3 of 216 REVISION HISTORY The revision history for this test report is shown in table. Revision No. Date of Issue Description 0 February 10, 2026 Initial Release 1 February 20, 2026 - Revised the test results in Section 5.2 - Updated the test results in Section 5.3 - Revised the test results in Section 5.4 - Added plots for the Input/Output power in Section 5.5. - Revised the test results in Section 5.6 Notice Content Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules under normal use and maintenance. The results shown in this test report only apply to the sample(s), as received, provided by the applicant, unless otherwise stated. The test results have only been applied with the test methods required by the standard(s). The laboratory is not accredited for the test results marked *. Information provided by the applicant is marked **. Test results provided by external providers are marked ***. When confirmation of authenticity of this test report is required, please contact www.hct.co.kr The test results in this test report are not associated with the ((KS Q) ISO/IEC 17025) accreditation by KOLAS (Korea Laboratory Accreditation Scheme) / A2LA (American Association for Laboratory Accreditation) that are under the ILAC (International Laboratory Accreditation Cooperation) Mutual Recognition Agreement (MRA). The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 4 of 216 CONTENTS 1. GENERAL INFORMATION 5 1.1. APPLICANT INFORMATION 5 1.2. PRODUCT INFORMATION 5 1.3. TEST INFORMATION 5 2. FACILITIES AND ACCREDITATIONS 6 2.1. FACILITIES 6 2.2. EQUIPMENT 6 3. TEST SPECIFICATIONS 7 3.1. STANDARDS 7 3.2. ADDITIONAL DESCRIPTIONS ABOUT TEST 8 3.3. MEASUREMENTUNCERTAINTY 10 3.4. STANDARDS ENVIRONMENTAL TEST CONDITIONS 10 3.5. TEST DIAGRAMS 11 4. TEST EQUIPMENTS 13 5. TEST RESULT 14 5.1. AGC THRESHOLD 14 5.2. OUT-OF-BAND REJECTION 16 5.3. OCCUPIED BANDWIDTH 19 5.4. INPUT-VERSUS-OUTPUT SIGNAL COMPARISON 94 5.5. INPUT/OUTPUT POWER AND AMPLIFIER/BOOSTER GAIN 166 5.6. NOISE FIGURE 177 5.7. OUT-OF-BAND/OUT-OF-BLOCK EMISSIONS AND SPURIOUS EMISSIONS 181 5.8. RADIATED SPURIOUS EMISSIONS 205 5.9. FREQUENCY STABILITY 208 6. Annex A_EUT AND TEST SETUP PHOTO 216 The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 5 of 216 1. GENERAL INFORMATION 1.1. APPLICANT INFORMATION Company Name ADRF KOREA, Inc. Company Address 196-16 IYEO-RO BAEKSA-MYEON ICHEON-SI, GYEONGGI-DO, 17316, KOREA 1.2. PRODUCT INFORMATION EUT Type Public Safety Repeater EUT Serial Number P789533NBXXXXXX Power Supply AC 110~220 Vac Frequency Range Band Name Uplink (MHz) Downlink (MHz) PS Narrowband 799 ~ 805 769 ~ 775 NPSPAC 806 ~ 809 851 ~ 854 B/ILT; SMR 809 ~ 816 854 ~ 861 ESMR 817 ~ 824 862 ~ 869 Tx Output Power Uplink: 30 dBm, Downlink: 33 dBm Antenna Peak Gain Band Name Uplink Downlink PS Narrowband 6.5 dBd 2.6 dBi NPSPAC 3.9 dBi B/ILT; SMR ESMR 1.3. TEST INFORMATION FCC Rule Parts CFR 47 Part 90 Measurement Standards KDB 935210 D05 v01r04, KDB 971168 D01 v03r01, ANSI C63.26-2015 Test Location 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 6 of 216 2. FACILITIES AND ACCREDITATIONS 2.1. FACILITIES The SAC(Semi-Anechoic Chamber) and conducted measurement facility used to collect the radiated data are located at the 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Republic of Korea. The site is constructed in conformance with the requirements of ANSI C63.4. (Version :2014) and CISPR Publication 22. Detailed description of test facility was submitted to the Commission and accepted dated March 11, 2024 (Registration Number: KR0032). 2.2. EQUIPMENT Radiated emissions are measured with one or more of the following types of linearly polarized antennas: tuned dipole, bi-conical, log periodic, bi-log, and/or ridged waveguide, ho…
Text truncated - open the document above for the full version.
The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 60 of 216 Input / Public Safety Narrowband / Downlink / P25 Phase 2 (H-DQPSK) Output / Public Safety Narrowband / Downlink / P25 Phase 2 (H-DQPSK) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 61 of 216 3 dB above the AGC threshold Input / Public Safety Narrowband / Downlink / P25 Phase 2 (H-DQPSK) 3 dB above the AGC threshold output / Public Safety Narrowband / Downlink / P25 Phase 2 (H-DQPSK) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 62 of 216 Input / Public Safety Narrowband / Downlink / FM (12.5 kHz) Output / Public Safety Narrowband / Downlink / FM (12.5 kHz) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 63 of 216 3 dB above the AGC threshold Input / Public Safety Narrowband / Downlink / FM (12.5 kHz) 3 dB above the AGC threshold output / Public Safety Narrowband / Downlink / FM (12.5 kHz) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 64 of 216 Input / Public Safety Narrowband / Downlink / FM (25 kHz) Output / Public Safety Narrowband / Downlink / FM (25 kHz) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 65 of 216 3 dB above the AGC threshold Input / Public Safety Narrowband / Downlink / FM (25 kHz) 3 dB above the AGC threshold output / Public Safety Narrowband / Downlink / FM (25 kHz) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 66 of 216 Input / NPSPAC / Downlink / P25 Phase 1 (C4FM) Output / NPSPAC / Downlink / P25 Phase 1 (C4FM) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 67 of 216 3 dB above the AGC threshold Input / NPSPAC / Downlink / P25 Phase 1 (C4FM) 3 dB above the AGC threshold output / NPSPAC / Downlink / P25 Phase 1 (C4FM) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 68 of 216 Input / NPSPAC / Downlink / P25 Phase 1 (CQPSK) Output / NPSPAC / Downlink / P25 Phase 1 (CQPSK) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 69 of 216 3 dB above the AGC threshold Input / NPSPAC / Downlink / P25 Phase 1 (CQPSK) 3 dB above the AGC threshold output / NPSPAC / Downlink / P25 Phase 1 (CQPSK) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 70 of 216 Input / NPSPAC / Downlink / P25 Phase 2 (H-DQPSK) Output / NPSPAC / Downlink / P25 Phase 2 (H-DQPSK) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 71 of 216 3 dB above the AGC threshold Input / NPSPAC / Downlink / P25 Phase 2 (H-DQPSK) 3 dB above the AGC threshold output / NPSPAC / Downlink / P25 Phase 2 (H-DQPSK) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 72 of 216 Input / NPSPAC / Downlink / FM (12.5 kHz) Output / NPSPAC / Downlink / FM (12.5 kHz) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 73 of 216 3 dB above the AGC threshold Input / NPSPAC / Downlink / FM (12.5 kHz) 3 dB above the AGC threshold output / NPSPAC / Downlink / FM (12.5 kHz) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 74 of 216 Input / B/ILT; SMR / Downlink / P25 Phase 1 (C4FM) Output / B/ILT; SMR / Downlink / P25 Phase 1 (C4FM) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 75 of 216 3 dB above the AGC threshold Input / B/ILT; SMR / Downlink / P25 Phase 1 (C4FM) 3 dB above the AGC threshold output / B/ILT; SMR / Downlink / P25 Phase 1 (C4FM) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 76 of 216 Input / B/ILT; SMR / Downlink / P25 Phase 1 (CQPSK) Output / B/ILT; SMR / Downlink / P25 Phase 1 (CQPSK) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 77 of 216 3 dB above the AGC threshold Input / B/ILT; SMR / Downlink / P25 Phase 1 (CQPSK) 3 dB above the AGC threshold output / B/ILT; SMR / Downlink / P25 Phase 1 (CQPSK) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 78 of 216 Input / B/ILT; SMR / Downlink / P25 Phase 2 (H-DQPSK) Output / B/ILT; SMR / Downlink / P25 Phase 2 (H-DQPSK) The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 79 of 216 3 dB above the AGC threshold Input / B/ILT; SMR / Downlink / P25 Phase 2 (H-DQPSK) 3 dB above the AGC threshold output / B/ILT; SMR / Downlink / P25 Phase 2 (H-DQPSK) The report shall not be (partly) reprodu…
Text truncated - open the document above for the full version.
The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 102 of 216 Input / Public Safety Narrowband / Uplink / FM (12.5 kHz) / Mask C Output / Public Safety Narrowband / Uplink / FM (12.5 kHz) / Mask C The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 103 of 216 3 dB above the AGC threshold Input / Public Safety Narrowband / Uplink / FM (12.5 kHz) / Mask C 3 dB above the AGC threshold output / Public Safety Narrowband / Uplink / FM (12.5 kHz) / Mask C The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 104 of 216 Input / Public Safety Narrowband / Uplink / FM (25 kHz) / Mask C Output / Public Safety Narrowband / Uplink / FM (25 kHz) / Mask C The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 105 of 216 3 dB above the AGC threshold Input / Public Safety Narrowband / Uplink / FM (25 kHz) / Mask C 3 dB above the AGC threshold output / Public Safety Narrowband / Uplink / FM (25 kHz) / Mask C The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 106 of 216 Input / NPSPAC / Uplink / P25 Phase 1 (C4FM) / Mask H Output / NPSPAC / Uplink / P25 Phase 1 (C4FM) / Mask H The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 107 of 216 3 dB above the AGC threshold Input / NPSPAC / Uplink / P25 Phase 1 (C4FM) / Mask H 3 dB above the AGC threshold output / NPSPAC / Uplink / P25 Phase 1 (C4FM) / Mask H The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 108 of 216 Input / NPSPAC / Uplink / P25 Phase 2 (H-CPM)/ Mask H Output / NPSPAC / Uplink / P25 Phase 2 (H-CPM)/ Mask H The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 109 of 216 3 dB above the AGC threshold Input / NPSPAC / Uplink / P25 Phase 2 (H-CPM)/ Mask H 3 dB above the AGC threshold output / NPSPAC / Uplink / P25 Phase 2 (H-CPM)/ Mask H The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 110 of 216 Input / NPSPAC / Uplink / FM (12.5 kHz) / Mask H Output / NPSPAC / Uplink / FM (12.5 kHz) / Mask H The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 111 of 216 3 dB above the AGC threshold Input / NPSPAC / Uplink / FM (12.5 kHz) / Mask H 3 dB above the AGC threshold output / NPSPAC / Uplink / FM (12.5 kHz) / Mask H The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 112 of 216 Input / B/ILT; SMR / Uplink / P25 Phase 1 (C4FM) / Mask D Output / B/ILT; SMR / Uplink / P25 Phase 1 (C4FM) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 113 of 216 3 dB above the AGC threshold Input / B/ILT; SMR / Uplink / P25 Phase 1 (C4FM) / Mask D 3 dB above the AGC threshold output / B/ILT; SMR / Uplink / P25 Phase 1 (C4FM) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 114 of 216 Input / B/ILT; SMR / Uplink / P25 Phase 2 (H-CPM)/ Mask D Output / B/ILT; SMR / Uplink / P25 Phase 2 (H-CPM)/ Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 115 of 216 3 dB above the AGC threshold Input / B/ILT; SMR / Uplink / P25 Phase 2 (H-CPM)/ Mask D 3 dB above the AGC threshold output / B/ILT; SMR / Uplink / P25 Phase 2 (H-CPM)/ Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 116 of 216 Input / B/ILT; SMR / Uplink / FM (12.5 kHz) / Mask D Output / B/ILT; SMR / Uplink / FM (12.5 kHz) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 117 of 216 3 dB above the AGC threshold Input / B/ILT; SMR / Uplink / FM (12.5 kHz) / Mask D 3 dB above the AGC threshold output / B/ILT; SMR / Uplink / FM (12.5 kHz) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 118 of 216 Input / B/ILT; SMR / Uplink / FM (25 kHz) / Mask G Output / B/ILT; SMR / Uplink / FM (25 kHz) / Mask G The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 119 of 216 3 dB above the AGC threshold Input / B/ILT; SMR / Uplink / FM (25 kHz) / Mask G 3 dB above the AGC threshold output / B/ILT; SMR / Uplink / FM (25 kHz) / Mask G The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 120 of 216 Input / ESMR / Uplink / P25 Phase 1 (C4FM) / Mask D Output / ESMR / Uplink / P25 Phase 1 (C4FM) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 121 of 216 3 dB above the AGC threshold Input / ESMR / Uplink / P25 Ph…
Text truncated - open the document above for the full version.
The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 134 of 216 Input / Public Safety Narrowband / Downlink / FM (12.5 kHz) / Mask C Output / Public Safety Narrowband / Downlink / FM (12.5 kHz) / Mask C The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 135 of 216 3 dB above the AGC threshold Input / Public Safety Narrowband / Downlink / FM (12.5 kHz) / Mask C 3 dB above the AGC threshold output / Public Safety Narrowband / Downlink / FM (12.5 kHz) / Mask C The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 136 of 216 Input / Public Safety Narrowband / Downlink / FM (25 kHz) / Mask C Output / Public Safety Narrowband / Downlink / FM (25 kHz) / Mask C The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 137 of 216 3 dB above the AGC threshold Input / Public Safety Narrowband / Downlink / FM (25 kHz) / Mask C 3 dB above the AGC threshold output / Public Safety Narrowband / Downlink / FM (25 kHz) / Mask C The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 138 of 216 Input / NPSPAC / Downlink / P25 Phase 1 (C4FM) / Mask H Output / NPSPAC / Downlink / P25 Phase 1 (C4FM) / Mask H The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 139 of 216 3 dB above the AGC threshold Input / NPSPAC / Downlink / P25 Phase 1 (C4FM) / Mask H 3 dB above the AGC threshold output / NPSPAC / Downlink / P25 Phase 1 (C4FM) / Mask H The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 140 of 216 Input / NPSPAC / Downlink / P25 Phase 1 (CQPSK) / Mask H Output / NPSPAC / Downlink / P25 Phase 1 (CQPSK) / Mask H The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 141 of 216 3 dB above the AGC threshold Input / NPSPAC / Downlink / P25 Phase 1 (CQPSK) / Mask H 3 dB above the AGC threshold output / NPSPAC / Downlink / P25 Phase 1 (CQPSK) / Mask H The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 142 of 216 Input / NPSPAC / Downlink / P25 Phase 2 (H-DQPSK) / Mask H Output / NPSPAC / Downlink / P25 Phase 2 (H-DQPSK) / Mask H The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 143 of 216 3 dB above the AGC threshold Input / NPSPAC / Downlink / P25 Phase 2 (H-DQPSK) / Mask H 3 dB above the AGC threshold output / NPSPAC / Downlink / P25 Phase 2 (H-DQPSK) / Mask H The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 144 of 216 Input / NPSPAC / Downlink / FM (12.5 kHz) / Mask H Output / NPSPAC / Downlink / FM (12.5 kHz) / Mask H The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 145 of 216 3 dB above the AGC threshold Input / NPSPAC / Downlink / FM (12.5 kHz) / Mask H 3 dB above the AGC threshold output / NPSPAC / Downlink / FM (12.5 kHz) / Mask H The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 146 of 216 Input / B/ILT; SMR / Downlink / P25 Phase 1 (C4FM) / Mask D Output / B/ILT; SMR / Downlink / P25 Phase 1 (C4FM) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 147 of 216 3 dB above the AGC threshold Input / B/ILT; SMR / Downlink / P25 Phase 1 (C4FM) / Mask D 3 dB above the AGC threshold output / B/ILT; SMR / Downlink / P25 Phase 1 (C4FM) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 148 of 216 Input / B/ILT; SMR / Downlink / P25 Phase 1 (CQPSK) / Mask D Output / B/ILT; SMR / Downlink / P25 Phase 1 (CQPSK) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 149 of 216 3 dB above the AGC threshold Input / B/ILT; SMR / Downlink / P25 Phase 1 (CQPSK) / Mask D 3 dB above the AGC threshold output / B/ILT; SMR / Downlink / P25 Phase 1 (CQPSK) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 150 of 216 Input / B/ILT; SMR / Downlink / P25 Phase 2 (H-DQPSK) / Mask D Output / B/ILT; SMR / Downlink / P25 Phase 2 (H-DQPSK) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 151 of 216 3 dB above the AGC threshold Input / B/ILT; SMR / Downlink / P25 Phase 2 (H-DQPSK) / Mask D 3 dB above the AGC threshold output / B/ILT; SMR / Downlink / P25 Phase 2 (H-DQPSK) / Mask D The report shall not be (partly) reproduced except in full without approval of the laboratory. Report No. HCT-RF-2602-FC004-R1 F-TP22-03 (Rev. 06) Page 152 of 216 Input / B/ILT; SMR / Downlink / FM (12.5 kHz) / Mask D Output / B/ILT; SMR / Downlink / FM (12.5 kHz) / Mask D The report shall not be (partly) reproduced except in…
Text truncated - open the document above for the full version.
3116 W Vanowen St. · Burbank, California, 91505 · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 9 | 799 MHz - 805 MHz | 957.00 mW | G7W | Amp |
| 2 | 9 | 806 MHz - 809 MHz | 1.072 W | G7W | Amp |
| 3 | 9 | 809 MHz - 816 MHz | 968.00 mW | G7W | Amp |
| 4 | 9 | 817 MHz - 824 MHz | 975.00 mW | G7W | Amp |
| 5 | 9 | 769 MHz - 775 MHz | 2.032 W | G7W | Amp |
| 6 | 9 | 851 MHz - 854 MHz | 2.084 W | G7W | Amp |
| 7 | 9 | 854 MHz - 861 MHz | 1.914 W | G7W | Amp |
| 8 | 9 | 862 MHz - 869 MHz | 1.901 W | G7W | Amp |
Equipment Class
B9A - Part 90 Class A Industrial Booster (non-SMR)Equipment Class
B9B - Part 90 Class B Industrial Booster (non-SMR)Equipment Class
B9A - Part 90 Class A Industrial Booster (non-SMR)Equipment Class
B9B - Part 90 Class B Industrial Booster (non-SMR)Equipment Class
B9A - Part 90 Class A Industrial Booster (non-SMR)