FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Smart Technologies & Investment Ltd/
  3. N9KMARTWS201

N9KMARTWS201SMART PANEL

Smart Technologies & Investment Ltd
SMART PANEL - FCC ID N9KMARTWS201 - Smart Technologies & Investment Ltd
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
May 28, 2012
Application Purpose
Original Equipment
Date of Application
May 28, 2012
Equipment Note
SMART PANEL
Frequency Range
433.92000000 - 433.92000000
Company
Smart Technologies & Investment Ltd
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—
β†—

Internal Photos

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ITSS-9000 USER GUIDE COMPLETE WIRELESS ALARM SYSTEM Section 1 – Getting started1.1 General system overview1.2 Introduction to the system1.3 Items included with the system1.4 Introduction to the Smart Panel 1.5 Introduction to the Smart Panel backlightSection 2 – Installing the Complete Wireless Alarm System2.1 Installing the Smart Panel 2.2 Powering up the Smart Panel 2.3 Understanding the battery and AC adaptor iconSection 3 – Using the Complete Wireless Alarm System3.1 Programming your 4-digit PIN3.2 Transmitting an emergency (Panic) alarm 3.2.1 Using the Panic alarm 3.2.2 Using the Panic alarm without activating the siren 3.3 Operating different modes 3.3.1 STANDBY mode3.3.2 ARM mode A. Adjusting Exit DelayB. Adjusting Entry DelayC. Adjusting the Alarm DurationD. Muting the Audible CountdownE. Arming the systemF. Disarming the systemG. Zone settingsH. Triggers in ARM mode 3.3.3 ALERT mode A. Entering the ALERT modeB. Exiting the ALERT modeC. Zone settings 3.3.4 HOME mode A. Entering the HOME modeB. Exiting the HOME modeC. Zone settings Section 4 – Installing the Sensors4.1 Introduction to the Sensors 4.2 Installing the Sensors 4.2.1 Installing the Door/Window Sensor A. Powering up the the Door/Window SensorB. Installing the Door/Window SensorC. Mounting with the double-sided adhesive pad 4.2.2 Installing the Motion Sensor A. Powering up the Motion Sensor B. Installing the Motion SensorC. Sensor sensitivity D. Walk testE. Mounting using screws 4.2.3 Introduction of Key Fob Remote Control A. Introduction CONTENTS 135 13 ITSS-9000A Smart PanelITSS-9000B Window SensorITSS-9000C Motion SensorITSS-9000D Remote Control B. Operation i. Powering up the Key Fob Remote Controlii. Enrolling the Remote Control onto the Smart Paneliii. Operating the Key Fob Remote Controliv. Deleting a Remote Control from the Smart Panelv. Querying the ID Number of a Remote Control 4.3 House Security Code settings4.4 Zone Code settings Section 5 - Troubleshooting5.1 FAQ5.2 Troubleshooting Section 6 – General Information6.1 Product information6.2 Specifications 6.2.1 Smart Panel 6.2.2 Key Fob Remote Control6.2.3 Door/Window Sensor 6.2.4 Motion Sensor 6.3 Maintenance6.4 BatteriesSection 7 – FCC STATEMENTSection 8 – Premium 24/7/365 Central Station Monitoring Available. SECTION 1 – GETTING STARTED 1.1 General system overviewCAUTION! The 9V battery in the Smart Panel is for power back-up purposes only, and the unit should be supplied with main power (through the AC adaptor) at all times. Difficulty in disarming the Smart Panel in ALARM mode may occur when it is powered by the back-up battery alone. This is not a malfunction, and can be resolved by the use of a fresh 9V battery and main power supplied through the AC adaptor included.IMPORTANT! Due to the strong signal of the alarm, we advise that you change the House Security Code settings (explained in Section 4.3), if you suspect that one of your in-range neighbors may also be using this type of alarm systemAlarm system limitationsEven the most advanced alarm systems cannot guarantee 100% protection against burglary or environmental problems. All alarm systems are subject to possible compromise or failure-to-warn for a variety of reasons.* Please note that you may encounter problems with your system if:                                                                            !                        " !                     once per week ensure the sensors and siren(s) are working properly.*Although having an alarm system may make you eligible for reduced insurance premiums, the system is no substitute for insurance.WARNING: Security system devices cannot compensate for loss of life or property. 1.2 Introduction to the system#   $ & ' !           +  features. The system is controlled by a Smart Panel, which gathers information from wireless sensors placed inside and at the entry points of your home or office. If the Smart Panel detects a security breach, indicator lights will flash and the siren(s) will sound. Details of how to correctly install and operate the system are contained within this User Guide.1.3 Items included with the systemPlease check that all of the following items were included in the package before installing the system: A. Smart Panel ITSS-9000A B. Key Fob Remote Control ITSS-9000D C. Door/Window Sensors ITSS-9000B D. Motion Sensor ITSS-9000C E. AC adaptor for Smart PanelF. Double-sided adhesive strips for Door/Window Sensor G. Screws, wall plugs, tamperproof magnet and double-sided adhesive strip for Smart Panel H. Mounting bracket for Motion Sensor 7      8;'  < = 1921 2223 - 1 - Sound output: Chime (ding-dong)Smart Panel – flashes GREEN every 1.5 seconds with triggered zone indicated (To stop panel flashes - press ) 1.4 Introduction to the Smart Panel 1.5 Introduction to the Smart Panel sound alert and backlight LCD Screen:Function Buttons:Programming Buttons: Numeric Buttons: Keypad: Other:9V DC INPUT portSiren outputBattery compartment:4 x Pin header, 4 x Jumper8 x Pin header, 1 x Jumperβ€œRESET” button For AC/DC adaptor120dB For 9V Alkaline back-up battery For House Security Code settingFor Zone Code settingIf you forget the 4-digit PIN, press the β€œRESET” button located in the battery compartment and enter factory default PIN β€œ 1 2 3 4 ” followed by to restore factory settings Operating ModeARM Situation Zone triggered under ARM status Alarm duration: Adjustable between 1 – 6 minutes (siren). Default is 1 minuteS…

Text truncated - open the document above for the full version.

Cover Letter(s)

Smart Technologies & Investment Ltd. April 20, 2012 To: SIEMIC, INC. 2206 Ringwood Avenue, San Jose, CA 95131 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, ______ Smart Technologies & Investment Ltd. ___hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): Product Description: SMART PANEL Model name: WS201 We affirm that between SIEMIC and _ Smart Technologies & Investment Ltd. __, any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Contact information / address: Units C & D, 18/F Spectrum Tower, No.53 Hung To Road, Kwun Tong, Kowloon, Hong Kong

Cover Letter(s)

SCS-F19: Confidentiality Request Letter Page 1 of 1 Rev 2.0 Smart Technologies & Investment Ltd. April 20, 2012 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Confidentiality Request regarding application for certification of FCC ID: N9KSMARTWS201 We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Operational Description - Schematic The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Contact information / address: Units C & D, 18/F Spectrum Tower, No.53 Hung To Road, Kwun Tong, Kowloon, Hong Kong

ID Label/Location Info

FCC Certification label Sample FCC ID: N9KSMARTWS201 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

ID Label/Location Info

FCC Certification label location Sample Label location

Test Report

Page 1 of 39 FCC ID: N9KSMARTWS201 ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20120733 APPLICATION CERTIFICATION On Behalf of Smart Technologies & Investment Ltd. SMART PANEL Model No.: WS201 FCC ID: N9KSMARTWS201 Prepared for : Smart Technologies & Investment Ltd. Address : Units C & D, 18/F Spectrum Tower, No.53 Hung To Road, Kwun Tong, Kowloon, Hong Kong Prepared by : ACCURATE TECHNOLOGY CO., LTD Address : F1, Bldg. A, Changyuan New Material Port, Keyuan Rd. Science & Industry Park, Nanshan, Shenzhen, Guangdong P.R. China Tel: (0755) 26503290 Fax: (0755) 26503396 Report Number : ATE20120733 Date of Test : April 15-23, 2012 Date of Report : April 23, 2012 Page 2 of 39 FCC ID: N9KSMARTWS201 ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20120733 TABLE OF CONTENTS Description Page Test Report Certification 1. GENERAL INFORMATION .......................................................................................................... 5 1.1. Description of Device (EUT)....................................................................................................................5 1.2. Description of Test Facility ......................................................................................................................6 1.3. Measurement Uncertainty.........................................................................................................................6 2. MEASURING DEVICE AND TEST EQUIPMENT ..................................................................... 7 3. SUMMARY OF TEST RESULTS................................................................................................... 8 4. THE FIELD STRENGTH OF RADIATION EMISSION ............................................................ 9 4.1. Block Diagram of Test Setup....................................................................................................................9 4.2. The Field Strength of Radiation Emission Measurement Limits............................................................10 4.3. Configuration of EUT on Measurement .................................................................................................10 4.4. Operating Condition of EUT ..................................................................................................................10 4.5. Test Procedure ........................................................................................................................................11 4.6. The Field Strength of Radiation Emission Measurement Results ..........................................................12 5. 20DB OCCUPIED BANDWIDTH ................................................................................................ 14 5.1. Block Diagram of Test Setup..................................................................................................................14 5.2. The Bandwidth of Emission Limit According To FCC Part 15 Section 15.231(c) ................................14 5.3. EUT Configuration on Measurement .....................................................................................................15 5.4. Operating Condition of EUT ..................................................................................................................15 5.5. Test Procedure ........................................................................................................................................15 5.6. Measurement Result ...............................................................................................................................16 6. RELEASE TIME MEASUREMENT............................................................................................ 17 6.1. Block Diagram of Test Setup..................................................................................................................17 6.2. Release Time Measurement According To FCC Part 15 Section 15.231(a) ..........................................17 6.3. EUT Configuration on Measurement .....................................................................................................18 6.4. Operating Condition of EUT ..................................................................................................................18 6.5. Test Procedure ........................................................................................................................................18 6.6. Measurement Result ...............................................................................................................................19 7. AVERAGE FACTOR MEASUREMENT .................................................................................... 20 7.1. Block Diagram of Test Setup..................................................................................................................20 7.2. Average factor Measurement according to ANSI 63.4: 2003.................................................................20 7.3. EUT Configuration on Measurement .....................................................................................................21 7.4. Operating Condition of EUT ..................................................................................................................21 7.5. Test Procedure ........................................................................................................................................21 7.6. Measurement Result ...............................................................................................................................22 8. AC POWER LINE CONDUCTED EMISSION FOR FCC PART 15 SECTION 15.207(A) .. 23 8.1. Block Diagram of Test Setup..................................................................................................................23 8.2. The Emission Limit ................................................................................................................................23 8.3. Configuration of EUT on Mea…

Text truncated - open the document above for the full version.

Test Setup Photos

Powerline Conducted Emission Radiated Emission Below 1G Above 1G

Contact Information

Applicant

Ling Li(Sales Admin. Manager)
[email protected]852-2357 0104Fax: 852-2389 7524

Test Firm

Accurate Technology Co., Ltd.Sean Liu
[email protected]86-755-26503291Fax: 86-755-26503396

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from Smart Technologies & Investment Ltd

Bluetooth Personal Alarm - FCC ID N9KSMARTMD328E - Smart Technologies & Investment Ltd
N9KSMARTMD328E

Bluetooth Personal Alarm

Jan 11, 2020

Equipment Class

DTS - Digital Transmission System
MaceAlert Smart Panel - FCC ID N9KSMARTMA0136 - Smart Technologies & Investment Ltd
N9KSMARTMA0136

MaceAlert Smart Panel

Dec 10, 2015

Equipment Class

DTS - Digital Transmission System
Keychain Remote Control - FCC ID N9KSMARMA136TX - Smart Technologies & Investment Ltd
N9KSMARMA136TX

Keychain Remote Control

Dec 10, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
KEY PAD CONTROL - FCC ID N9KSMARTWS104 - Smart Technologies & Investment Ltd
N9KSMARTWS104

KEY PAD CONTROL

Nov 14, 2013

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
GTO ACCESS WIRELESS ESTATE INTERCOM - FCC ID N9KGTOF3100 - Smart Technologies & Investment Ltd
N9KGTOF3100

GTO ACCESS WIRELESS ESTATE INTERCOM

Jul 08, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter