FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Datamars SA/
  3. NDX-GW2

NDX-GW2Activetag Edge Gateway

Datamars SA

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Sep 19, 2024
Application Purpose
Original Equipment
Date of Application
Sep 19, 2024
Equipment Note
Activetag Edge Gateway
Frequency Range
2402.00000000 - 2480.00000000
Company
Datamars SA
Country
Switzerland

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

FRN: 0009294984 Sincerely yours, Applicant Signature PrintedName:JACKY CHOU Title:COMPLIANCE ENGINEER Address:Via Industria 16, CH-6814 Lamone, Switzerland Tel.:+6495748854 Email:[email protected]

Attestation Statements

DATAMARS SA Attestation Statements Not Covered Entity Applicant To: Federal Communications Commission Date: 05/04/2023 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: NDX-GW2 DATAMARS SA (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely yours, Applicant Signature Printed Name: JACKY CHOU Title: COMPLIANCE ENGINEER Address: Via Industria 16, CH-6814 Lamone, Switzerland Tel.: +6495748854 Email: [email protected]

Attestation Statements

DATAMARS SA Attestation Statements Not Covered Equipment To: Federal Communications Commission Date: 05/04/2023 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) filing FCC ID: NDX-GW2 DATAMARS SA (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Applicant Signature Printed Name: JACKY CHOU Title: COMPLIANCE ENGINEER Address: Via Industria 16, CH-6814 Lamone, Switzerland Tel.: +6495748854 Email: [email protected]

Cover Letter(s)

QF094234 Page 1 of 1 Revision 0 Authority to Act as Agent Date: 05 Apr 2023 TUV Rheinland Group 762 Park Avenue Youngsville, NC 27596 To Whom It May Concern: Datamars SA appoint TUV Rheinland (Shenzhen) Co., Ltd. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with Datamars SA/ Via Industria 16, CH-6814 Lamone, Switzerland. For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date: Issue of FCC grant for the NDX-GW2 By : JACKY CHOU (Signature) (Print Name) Title : COMPLIANCE ENGINEER Telephone : +6495748854 On behalf of : DATAMARS SA (Company Name)

Cover Letter(s)

Confidentiality Letter Date: 05 Apr 2023 Subject: Confidentiality Request for FCC ID: NDX-GW2 and IC ID: 4678A-GW2 Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC/IC application be held confidential.C Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Permanent Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Part List/Tune-Up Procedure Short Term Permanent Schematics Short Term Permanent User’s Manual Short Term Test Setup Photos Short Term Antenna Structure DATAMARS SA has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04- 1705. Sincerely, By: (COMPLIANCE ENGINEER) JACKY CHOU (Signature/Title) (Print name)

RF Exposure Info

1 RF Exposure Compliance 1.1 Test Standards 1.2 MPE Limits of FCC and IC MPE Limit for FCC Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (B) Limits for General Population/Uncontrolled Exposure 0.3-1.34 614 1.63 *100 30 1.34-30 824/f 2.19/f *180/f 2 30 30-300 27.5 0.073 0.2 30 300-1,500 f/1500 30 1,500-100,000 1.0 30 MPE Limit for IC Test standard : FCC 47 CFR Part 2 Section 2.1091 RSS-102 Issue 5 Section 3.2 FCC ID: NDX-GW2 IC: 4678A-GW2 Page 1 of 3 FCC ID: NDX-GW2 IC: 4678A-GW2 RF Exposure Info. 1.3 Test Result Test Result: PASS This device is mobile device, and the applicant declares that the minimum separation distance is greater than 20cm, detail minimum distance refer to to below calculation table. Therefore MPE measurement or computational modeling should be used to determine compliance. MPE Calculation is based on the conducted power, and considering maximum power and antenna gain. The following formula is used to MPE evaluation. (1) The power density according to far-field model is: 2 ),( 4R GP S      Where: P = input power of the antenna. G = antenna gain relative to an isotropic antenna. , = elevation and azimuth angles. R = distance from the antenna to the point of investigation. (2) For single or multiple RF sources, the calculated power density should comply with following: 1 ,   i iLimit i S S Where: i S = the power density when the f is i . iLimit S , = the reference level requirement for power density when f is i . f = operating frequency. Page 2 of 3 FCC ID: NDX-GW2 IC: 4678A-GW2 RF Exposure Info. A. Stand-alone operation mode (worst mode) Operating Mode Band PG (dBm) PG (W) Calculation (mW/cm 2 ) FCC Limit (mW/cm 2 ) Verdict FLRC 2402-2480MHz 1.35 0.001 0.0003 1.0 Pass Wi-Fi 2412-2472MHz 24.88 0.307 0.0612 1.0 Pass Operating Mode Band PG (dBm) PG (W) Calculation (W/m 2 ) IC Limit (W/m 2 ) Verdict FLRC 2402-2480MHz 1.35 0.001 0.003 5.35 Pass Wi-Fi 2412-2472MHz 24.88 0.307 0.612 5.35 Pass B. Simultaneous Transmission operation mode (worst mode) FCC Operating Mode FLRC Ratio Wi-Fi Ratio Sum Ratio Limit Result FLRC + Wi-Fi 0.0003 0.0612 0.0615 <1 Pass IC Operating Mode FLRC Ratio Wi-Fi Ratio Sum Ratio Limit Result FLRC + Wi-Fi 0.0006 0.1143 0.1149 <1 Pass Note: 1. R = 0.2m Page 3 of 3 FCC ID: NDX-GW2 IC: 4678A-GW2 RF Exposure Info.

Test Report

2J0902-C115N Product Datasheet Key Features 2.4/5.0 GHz ISM - 2410-2490 MHZ - 4920-5925 MHz Connector Mount Ground Plane Independent High Performance Dimensions: Ø13.2 × 115.7 mm www.2j-antennae.comwww.2j-antennasusa.com Page: 1/8 2.4/5.0 GHz ISM Connector Mount DATAMARS SA Via Industria 16, 6814 Lamone, Switzerland www.2j-antennae.comwww.2j-antennasusa.com Page: 2/8 1. Antenna and electrical specifications Antenna Measurement Conditions: Free Space Measured in Certified CTIA 3D Anechoic Chamber 2. Mechanical and environmental specifications Specifications Mounting Type Dimensions (mm) Radome Radome color Operating Temperature (C) Storage Temperature (C) Substance Compliance 2J0902-C115N Connector Mount Ø13.2 × 115.7 ASA Black -40 to +85 -40 to +85 RoHS Parameters Standards Band (MHz) Frequency (MHz) Return Loss (dB) VSWR Efficiency (%) Peak Gain (dBi) Average Gain (dB) Impendance (Ohm) Polarisation Radiation Pattern Max. Input Power (W) Connector Type 2.4/5.0 GHz ISM Antenna WiFi, BT, ZigBee, ISM 50 Linear Omni-Directional 25 RP-SMA-Male Standard 2.4 GHz 2410-2490 ~-22.5 ~1.2:1 ~70.3 ~2.0 ~-1.5 5.0 GHz 4920-5925 ~-14.4 ~1.7:1 ~55.7 ~2.2 ~-2.7 -20 -15 -10 -5 0 23002500270029003100330035003700390041004300450047004900510053005500570059006100 R e tu rn L os s (dB) Frequency (MHz) www.2j-antennae.comwww.2j-antennasusa.com Page: 3/8 3. Antenna parameters 0 1 2 3 4 5 23002500270029003100330035003700390041004300450047004900510053005500570059006100 V S WR Frequency (MHz) www.2j-antennae.comwww.2j-antennasusa.com Page: 4/8 0 10 20 30 40 50 60 70 80 90 23002500270029003100330035003700390041004300450047004900510053005500570059006100 E f ficie n cy (%) Frequency (MHz) 0 1 2 3 4 23002500270029003100330035003700390041004300450047004900510053005500570059006100 P eak G ain (dBi) Frequency (MHz) -4 -3 -2 -1 0 23002500270029003100330035003700390041004300450047004900510053005500570059006100 A v er ag e Gain (d B) Frequency (MHz) www.2j-antennae.comwww.2j-antennasusa.com Page: 5/8 Radiation pattern reference www.2j-antennae.comwww.2j-antennasusa.com Page: 6/8 2450 and 5500 MHz Radiation pattern www.2j-antennae.comwww.2j-antennasusa.com Page: 7/8 4. Antenna drawings R6,6 RP SMA Male connector www.2j-antennae.comwww.2j-antennasusa.com Page: 8/8 5. Antenna Images

Test Report

Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN233FVW 001 Auftrags-Nr.: Order no.: 168403102 Seite 1 von 18 Page 1 of 18 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2022-12-15 Auftraggeber: Client: DATAMARS SA Via Industria 16, 6814 Lamone, Switzerland Prüfgegenstand: Test item: Activetag Edge Gateway Bezeichnung / Typ-Nr.: Identification / Type no.: GW2-Ethernet/WiFi(Part Number: 880 0004-658) Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: FCC CFR Title 47, Part 15, Subpart C, Section 15.249 RSS-210 Issue 10 December 2019 RSS-Gen Issue 5 March 2019 Wareneingangsdatum: Date of sample receipt: 2022-12-20 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A003389847-002 Prüfzeitraum: Testing period: 2022-12-20 – 2023-02-15 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: genehmigt von: authorized by: Datum: Date: 2024-06-30 Ausstellungsdatum: Issue date: 2024-06-30 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: NDX-GW2 IC: 4678A-GW2 HVIN: GW2 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 17-18F, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen 518052, P. R. China Mail: [email protected] · Web: www.tuv.com Jonat han Li Winnie Hou Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN233FVW 001 Test report no.: Seite 2 von 18 Page 2 of 18 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2021, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision rule for statements of conformity, based on numerical measurement results, in this test report is based on the “Zero Guard Band Rule” and “Simple Acceptance” in accordance with ILAC G8:2019 and IEC Guide 115:2021, unless otherwise specified in the applied standard mentione…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Damien Pachoud(CTO)
[email protected]0041919357478Fax: 0041919450330

Technical Contact

DATAMARS SAJACKY CHOU
[email protected]+6495748854

Via Industria 16 · Lamone · Switzerland

Test Firm

TUV Rheinland (Shenzhen) Co., Ltd.Gina Yang
[email protected]86 755 8268 1497

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term
Grant Notes
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device contains one 2.4 GHz WLAN transmitter.

Other Applications from Datamars SA

NDX-OMNIMAX2

RFID Scanner with Bluetooth Low Energy

Jun 02, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
NDX-PLCAT1

NINA-B4

May 04, 2026

Equipment Class

DTS - Digital Transmission System
RFID handheld reader for animal indentification - FCC ID NDX-COMPACTMAX - Datamars SA
NDX-COMPACTMAX

RFID handheld reader for animal indentification

Aug 17, 2014

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
RFID handheld reader for livestock applications - FCC ID NDX-OMNIMAX - Datamars SA
NDX-OMNIMAX

RFID handheld reader for livestock applications

Jan 19, 2014

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
RFID handheld reader for livestock applications - FCC ID NDX-TRACKING1 - Datamars SA
NDX-TRACKING1

RFID handheld reader for livestock applications

Dec 16, 2013

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral