Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
s FCC ID: NE3PCS011 March 7, 2005 TIMCO Engineering 849 NW State Road 45 Newberry, Florida 32669 RE: Confidentiality Request for FCC ID: NE3PCS011 Dear Sir or Madam, In accordance with Section 0.459 of the commission rules, Siemens ICM, LLC requests confidentiality for the following Exhibit Types: Operational Description, Parts List/Tune-up Info, Schematics, Block Diagrams, User Manuals, and Internal Photographs. This request is based on the following reasons: Siemens serves a market both new and technically very advanced. Hence competition among equipment providers is very high, with millions of dollars at stake. Siemens’ applications for certification contain technical information regarding technology it spent millions of dollars to develop. If classified as non- confidential, Siemens’ competitors would gain an unfair advantage at Siemens’ expense. User Manuals are not available to the general public in any form. User Manuals are sellable items, made available only to legitimate Siemens customers (mobile telephone operators who own FCC licenses for the appropriate frequency bands). It is Siemens’ policy to provide User Manuals to a third party only upon execution of a Mutual Non-Disclosure Agreement (“NDA”). Siemens base stations are normally installed in a restricted area, accessible only by Siemens or its customer. When not installed in a restricted area, such as a rooftop, Siemens base stations are always locked with temper-proof hardware and locks, again accessible only by Siemens and its customer. Accordingly, only authorized persons, who also previously signed an NDA, have access to the inside of a Siemens base station cabinet. By not classifying User Manuals and Internal Photographs as confidential, the FCC allows Siemens’ competitors (or anyone else) to access to Siemens’ confidential and proprietary information via the FCC’s web site. This would cause irreparable damage to Siemens and place Siemens at a competitive disadvantage. For these reasons, Siemens strongly requests confidentiality for the following Exhibit Types: Operational Description, Parts List/Tune-up Info, Schematics, Block Diagrams, User Manuals, and Internal Photographs. Sincerely, Rashmi J. Contractor Phone Number : 561-322-7065 e-mail: [email protected] Siemens Communications
Siemens AG Blatt Datum Bearb. Gepr. Norm Datum Name Zust.Mitteilung Copyright (C) Siemens AG 2004 A 4 - M A - D S F . d s f 01 C50324-a200-c425-1.dsf H B2 Com MN PG R 21.12.04 Haid 21.12.04 Bi Schild LABEL C50324-A200-C425-*-7406 1- FCC ID: NE3PCS011 ( 74 ) ( 9 ) Schrift SN 34180-B4 / UNIVERS 55 (4 mm hoch) / Lettering SN 34180-B4 / UNIVERS 55 (4 mm high) Schriftstil nur Beispiel, nicht original Textstyle only example, no original Beschriftung nach C50300-A200-C347-*-7404 Lettering according to C50300-A200-C347-*-7404 (...) Hilfsmass / Auxiliary dimension A A B 0 , 5 AA 1 A B
FCC ID:NE3PCS011 NE3PCS011_FDUAMCOPV2_FCUPV1.doc Page 2/69 09/02/2005 TABLE OF CONTENTS 1 EQUIPMENT UNDER TEST (EUT) 4 2 MEASUREMENTS 5 2.1 General description 5 2.1.1 EUT configuration and operating conditions 5 2.1.2 Selected carrier test frequencies 5 2.1.3 Modulation characteristics 5 2.1.4 Measurement test configuration 6 2.1.5 Calibration of the measurement equipment 6 2.2 Summary of the measurements 7 2.3 Test No. 1: RF power output (§ 2.1046) 8 2.3.1 Purpose 8 2.3.2 EUT operation condition 8 2.3.3 Test configuration 8 2.3.4 Measurement procedure and results 8 2.4 Test No. 2: Modulation characteristics (§ 2.1047, § 2.201) 9 2.5 Test No. 3: Occupied bandwidth (§ 2.1049) 10 2.5.1 Purpose 10 2.5.2 EUT operation condition 10 2.5.3 Test configuration 10 2.5.4 Measurement procedure and results 10 2.6 Test No. 4: Spurious emissions at antenna terminals (§ 2.1051, § 2.1057, § 24.238) 11 2.6.1 Purpose 11 2.6.2 Limits 11 2.6.3 EUT operation condition 11 2.6.4 Test configuration 11 2.6.5 Measurement procedure and results 11 2.7 Test No. 5: Field strength of spurious radiation (§ 2.1053, § 2.1057, § 24.238) 15 2.7.1 Purpose 15 2.7.2 Limits 15 2.7.3 EUT operation condition 15 2.7.4 Test configuration 15 2.7.5 Measurement procedure 16 2.7.6 Measurement results & limits 16 2.8 Test No. 6: Frequency stability (§ 2.1055, § 24.235) 18 2.8.1 Purpose 18 2.8.2 Limits 18 2.8.3 EUT operation condition 18 2.8.4 Test configuration 18 2.8.5 Measurement procedure 19 2.8.6 Measurement results 19 2.9 Test No. 7: Slow frequency hopping 20 2.9.1 Introduction 20 2.9.2 Purpose 20 2.9.3 EUT operation condition 20 2.9.4 Test configuration 20 2.9.5 Measurement procedure 20 2.9.6 Measurement results 21 FCC ID:NE3PCS011 NE3PCS011_FDUAMCOPV2_FCUPV1.doc Page 3/69 09/02/2005 3 MEASUREMENT DATA AND SPECTRAL PLOTS 22 3.1 Part list of the RF measurement test equipment 22 3.2 Spectral plots 23 3.2.1 Test No. 1: RF Power Output 23 3.2.2 Test No. 2: Modulation Characteristics 29 3.2.3 Test No. 3: Occupied Bandwidth 29 3.2.4 Test No. 4: Spurious Emissions at the Antenna Terminals 35 3.2.5 Test No. 5: Field Strength of Spurious Radiation 58 3.2.6 Test No. 6: Frequency Stability 63 3.2.7 Test No. 7: Slow Frequency Hopping 66 FCC ID:NE3PCS011 NE3PCS011_FDUAMCOPV2_FCUPV1.doc Page 4/69 09/02/2005 1 Equipment under test (EUT) The equipment under test (EUT) comprises the modules listed in the table below. Module Name Siemens Part No. Serial No. Test No. FCUPV1 S30861-U2408-X-05/01 UEB/SD216729 1, 2, 3, 4, 7 FDUAMCOPV2 (in 2:2 mode) S30861-U2412-X-02/01 RMX/S3300004 1, 2, 3, 4, 7 FCUPV1 S30861-U2408-X-05/01 UEB/SD216724 5 FCUPV1 S30861-U2408-X-05/01 UEB/SD216875 5 FDUAMCOPV2 (in 4:2 mode) S30861-U2412-X-03/01 RMX/S3300009 5 FCUPV1 S30861-U2408-X-05/01 UEB/SD216724 6 FCUPV1 S30861-U2408-X-05/01 UEB/SD216875 6 FDUAMCOPV2 (in 4:2 mode) S30861-U2412-X-03/01 RMX/S3300009 6 For a functional description of the modules, please refer to the appropriate related parts and exhibit sections of this certification application. The tests were conducted with the modules installed in a BS-240XLU II. Worst-case measurement data is reported. To comply with the FCC rules (§2.1051, §24.238), the maximum transmit power at the antenna port of channel numbers 512 (1930.2 MHz) and 810 (1989.8 MHz) is decreased according to the following table. Type of FCU Carrier Frequency [MHz] Channel No. Maximum RF power output GMSK Maximum RF power output 8PSK FCUPV1 1930.2 MHz 512 38.4 dBm = 6.9 W 41.7 dBm = 14.8 W FCUPV1 1989.8 MHz 810 38.5 dBm = 7.1 W 41.7 dBm = 14.8 W A complete description of the transceiver’s calibration/tuning procedure is included in the Parts List and TuneUp exhibit section of this application. FCC ID:NE3PCS011 NE3PCS011_FDUAMCOPV2_FCUPV1.doc Page 5/69 09/02/2005 2 Measurements 2.1 General description 2.1.1 EUT configuration and operating conditions If not stated otherwise, the following standard setup procedure for the EUT under test was used: A BSC simulator is used to control the EUT and is connected to the EUT via the A bis Link. For detailed test system equipment configuration please refer to Fig.1 on page 6. The transmitter modules were tuned up according to the procedure described in the TuneUp exhibit section of this application. During the measurements, one carrier channel was tested at a time. The carrier was set to the maximum power level with all timeslots activated to ensure the maximum emission amplitudes during all measurements. A pseudo random bit pattern was applied to the digital modulator. This ensures that the measurements of the emission characteristics of the transmitter are pursuant to § 2.1049. 2.1.2 Selected carrier test frequencies The measurements were performed at 3 selected carrier test frequencies, according to the following table: Carrier Test Frequency [MHz] Remark 1930.2 lowest possible carrier frequency 1960.0 frequency at the middle of the band 1989.8 highest possible carrier frequency 2.1.3 Modulation characteristics The EUT supports two types of modulation: GMSK and 8PSK. The modulation characteristic of the GMSK and the 8PSK modulation is defined in standard 3GPP TS 05.04. During all measurements described below, a pseudo random sequence was applied to the digital modulator to ensure that the emission characteristics of the transmitter are pursuant to § 2.1049. FCC ID:NE3PCS011 NE3PCS011_FDUAMCOPV2_FCUPV1.doc Page 6/69 09/02/2005 2.1.4 Measurement test configuration If not stated otherwise, the following measurement configuration was used to perform all measurements (see figure below): Freq. Stand. Abis GPIB FSIQ BTS 30 dB HF Test PC, BSC-Sim The EUT is controlled by a BSC simulator via the serial A bis Link. The RF output signal is connected to a spectrum analyzer (FSIQ26, Rohde&Schwarz) via a high power 30 dB attenuator. The attenuator is used to protect the input of the spectrum analyzer from high RF power levels. A description of the analyzer settings is given in each of the sections describing the measurem…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 3 | 24E | 1.99 GHz - 1.99 GHz | 14.8 W | 258KGXW | 0.05 ppm |

850 MHz CAT40, DUAMCO
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
1900 MHz CAT40, DUAMCO
Equipment Class
PCB - PCS Licensed Transmitter
850MHz FLEXCU AND FDUAMCO
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
High Power 1900 MHz Edge CU
Equipment Class
PCB - PCS Licensed Transmitter
850 High Power EDGE Base Station
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter