Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
External Photos Figure 1. Axell D-MBR Repeater External Front , Up & side view The following connections are available: Figure 2. D-MBR Front Panel External Front view Unit AC power connection Mobile/Service antenna connection Services and corresponding indicators Ethernet connection Dry contact alarms port Base/Donor antenna connection GPS antenna connection Coupler Mobile GND Figure 3. D-MBR with Removed Front Panel External photo with Removed Front Panel
A 4 Drawing Number Title First Angle Projection Drawn Date Checked Approved Scale THIS IS A PROPRIETARY DESIGN OF AXELL WIRELESS LTD REPRODUCTION OR USE OF THIS DESIGN BY OTHERS IS PERMISSABLE ONLY IF EXPRESSLY AUTHORISED IN WRITING BY AXELL WIRELESS LTD. REVISIONNo DATE BY GENERAL TOLERANCES ISO 2768-1 MEDIUM 2009-04-28 PerW PerW 2010-08-24 2010-08-24 9713000305 A 2:1 PerW ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED Tel : +46 (0)8 475 4700 Fax : +44 (0)8 475 4799 UNLESS STATED OTHERWISE Sheet 1 / 1 Rev. NOTE. 1. MATERIAL: SHEET SILVER COLOR METALIZED POLYESTER WITH ONE SIDE WITH 3M 467MP BACK ADHESIVE + ADHESIVE 200MP ON ONE SIDE. 2. PRINTING 2.1 BACKGROUND "a": SILVER 2.2 SYMBOLS AND FONTS "b" : BLACK 2.3 FONTS: HELVETICA MEDIUM 3. USE RIBBON ACCORDING TO LABEL MANUFACTURER RECOMENDATION. 4. FOR SERIAL NUMBER SEE LABEL INFORMATION. 5. BAR CODE TYPE ACCORDING TO CODE-128 6. THE LABELS MUST BE SUPPLIED ON ROLL. 7. PART MUST COMPLY RoHS REQUIREMENTS. 8. LABEL INFORMATION: YY-Year (2 Digits) MM- Month (2 Digits) ZZZZZZ- Serial No. 76.20 3 8 . 1 0 AXELL35781719D S/N LABEL
11 22 33 44 55 66 77 88 99 1010 1111 1212 A A B B C C D D E E F F G G H H A1 Drawing No Title First AngleProjection Drawn Date Checked Approved THIS IS A PROPRIETARY DESIGN OF AXELL WIRELESS LTDREPRODUCTION OR USE OF THIS DESIGN BY OTHER ISPERMISSABLE ONLY IF EXPRESSLY AUTHORISED IN WRITINGBY AXELL WIRELESS LTD GENERAL TOLERANCES SCALE ALL DIMENSIONS ARE IN mmUNLESS OTHERWISE STATED REVISION No DESCRIPTION DATE BY UNLESS STATED OTHERWISE ISO 2768-1 MEDIUM 2010-05-14 PerW 2010-05-14 PerW 2010-05-14 A PerW Tel : +46 (0)8 475 4700Fax : +46 (0)8 475 4799 Sheet 3 / 3 Rev. 20.00 3 2 . 0 0 VERIZON REPEATER 400AA21000
731 Enterprise Drive Lexington, KY 40510 Telephone: 859-226-1000 Facsimile: 859-226-1040 www.intertek-etlsemko.com MPE Calculation § 1.1310: The criteria listed in table 1 shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in §1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of §2.1093 of this chapter. Part 1.1310 Limits for Maximum Permissible Exposure (MPE) 1.1 Test Procedure An MPE evaluation for was performed in order to show that the device was compliant with §2.1091. The maximum power density was calculated for each transmitter at a separation distance of 20cm. For each transmitter the maximum RF exposure at a 20 cm distance using the formula: 2 )20(4 . cm mW GainAntPowerConducted tyPowerDensi × × = π 731 Enterprise Drive Lexington, KY 40510 Telephone: 859-226-1000 Facsimile: 859-226-1040 www.intertek-etlsemko.com 1.2 Results: The following calculations show that the total power density from each transmitter at 20cm is less than the limit for general population / un-controlled exposure. The device meets the RF exposure limit at a 20cm separation distance as required by part 2.1091 of the FCC rules when used with an antenna not exceeding the maximum antenna gain noted in the following table. Test Summary Frequency (MHz) Maximum Antenna Gain (dBi) MPE @ 20cm (mW/cm^2) Test Result 737 7.30 0.4903 Compliant 751.5 7.51 0.5000 Compliant 881.52 7.66 0.5867 Compliant 2132.5 6.19 0.9990 Compliant 1960 1.28 0.3146 Compliant LTE Lower Block Band: Frequency 737 MHz Limit 0.4913 mW/cm^2 Distance 20 cm Power 26.62 dBm 459.198 mW TX Ant Gain 7.30 dBi EIRP 33.92 dBm Power Density 0.4903 mW/cm^2 at 20cm LTE Upper Block Band: Frequency 751.5 MHz Limit 0.5010 mW/cm^2 Distance 20 cm Power 26.49 dBm 445.6562 mW TX Ant Gain 7.51 dBi EIRP 34.00 dBm Power Density 0.5000 mW/cm^2 at 20cm Cell Band: Frequency 881.52 MHz Limit 0.5877 mW/cm^2 Distance 20 cm Power 27.04 dBm 505.824 mW TX Ant Gain 7.66 dBi EIRP 34.70 dBm Power Density 0.5867 mW/cm^2 at 20cm AWS Band: Frequency 2132.5 MHz Limit 1.0000 mW/cm^2 Distance 20 cm Power 30.82 dBm 1207.81 mW TX Ant Gain 6.19 dBi EIRP 37.01 dBm Power Density 0.9990 mW/cm^2 at 20cm PCS Band: Frequency 1960 MHz Limit 1 mW/cm^2 Distance 20 cm Power 30.71 dBm TX Ant Gain 1.28 dBi EIRP 31.99 1581.24 mW Power Density 0.3146 mW/cm^2 at 20cm
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. EMC Report for Axell Wireless on the Page 1 of 44 731 Enterprise Drive Lexington, KY 40510 Telephone: 859-226-1000 Facsimile: 859-226-1040 www.intertek-etlsemko.com TEST REPORT Report Number: 100189971-LEX-002 Project Number: G100189971 Report Issue Date: 10/22/2010 Model: MW-DFR-PCS-3080 FCCID: NEO-DFR-PCS-3080 Standards: FCC Part 24 Subpart E Tested by: Client: Intertek Testing Services NA, Inc. 731 Enterprise Drive Lexington, KY 40510 Axell Wireless Aerial House Chesham Buckinghamshire HP5 2QD United Kingdom Report prepared by Report reviewed by Jason Centers, Senior Project Engineer Bryan Taylor, Team Leader Intertek Report Number: 100189971-LEX-002 Issued: 10/22/2010 EMC Report for Axell Wireless on the FCCID:NEO-DFR-PCS-3080 Page 2 of 44 TABLE OF CONTENTS 1 Introduction and Conclusion .............................................................................................................. 3 2 Test Summary ...................................................................................................................................... 3 3 Description of Equipment Under Test ............................................................................................... 4 4 Conducted Output Power.................................................................................................................... 6 5 Occupied Bandwidth ........................................................................................................................... 8 6 Conducted Spurious Emissions at Antenna Terminals ................................................................. 15 7 Radiated Spurious Emissions (Transmitter) ................................................................................... 38 8 Measurement Uncertainty ................................................................................................................. 43 9 Revision History................................................................................................................................. 44 Intertek Report Number: 100189971-LEX-002 Issued: 10/22/2010 EMC Report for Axell Wireless on the FCCID:NEO-DFR-PCS-3080 Page 3 of 44 1 Introduction and Conclusion The tests indicated in section 2 were performed on the product constructed as described in section 3. The remaining test sections are the verbatim text from the actual data sheets used during the investigation. These test sections include the test name, the specified test method, a list of the actual test equipment used, documentation photos, results and raw data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complied with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. The INTERTEK-Lexington is located at 731 Enterprise Drive, Lexington Kentucky, 40510. The radiated emission test site is a 10-meter semi-anechoic chamber. The chamber meets the characteristics of CISPR 16-1 and ANSI C63.4. For measurements, a remotely controlled flush-mount metal-top turntable is used to rotate the EUT a full 360 degrees. A remote controlled non-conductive antenna mast is used to scan the antenna height from one to four meters. The test site is listed with the FCC under registration number 485103. The test site is listed with Industry Canada under site number IC 2042M-1. 2 Test Summary Page Test full name FCC Reference Result 6 Conducted Output Power §2.1046 Pass 8 Occupied Bandwidth §2.1049 and §24.238(a) Pass 15 Conducted Spurious Emissions §2.1049, §2.1051, and § 24.238(a)(b) Pass 38 Radiated Spurious Emissions (Transmitter) §2.1053 and §24.238(a)(b) Pass - Frequency Stability §2.1055 Not Required 1 1 The device does not translate frequency. Intertek Report Number: 100189971-LEX-002 Issued: 10/22/2010 EMC Report for Axell Wireless on the FCCID:NEO-DFR-PCS-3080 Page 4 of 44 3 Description of Equipment Under Test Equipment Under Test Manufacturer Axell Wireless Model Number MW-DFR-PCS-3080 Serial Number 1008D1027 FCC Identifier NEO-DFR-PCS-3080 Receive Date 8/27/2010 Test Start Date 8/30/2010 Test End Date 9/30/2010 Device Received Condition Good Test Sample Type Production Frequency Band 1850MHz - 1910MHz (Uplink) 1930MHz – 1990MHz (Downlink) Modulation Type CDMA, W-CDMA, GSM Transmission Control Signal Generator Maximum Output Power (Conducted) 27.81 dBm (Uplink) 30.71 dBm (Downlink) Antenna Type External, User provided Operating Voltage 120VAC Description of Equipment Under Test The test sample was a cell booster device manufactured by Axell Wireless. Operating modes of the EUT: No. Descriptions of EUT Exercising 1 Device was set at max gain and tested at maximum output power at the low, mid and high frequencies in each band with CDMA, GSM and W-CDMA modulations for conducted tests. 2 Device was set at max gain and tested at maximum output power at the low, mid and high frequencies in each band with a CW for radiated spurious tests. Intertek …
Text truncated - open the document above for the full version.
Radiated Setup Radiated Setup Conducted Setup
6 Bareket st. Kiryat-Matalon · Tel-Aviv · Israel
| # | Rule Parts | Frequency Range | Power Output | Emission |
|---|---|---|---|---|
| 6 | 24E | 1.93 GHz - 1.99 GHz | 1 W | F9W4M17 |

BSF3604
Equipment Class
B9B - Part 90 Class B Industrial Booster (non-SMR)
MBF-37D7-3708
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
Class B Booster
Equipment Class
B9B - Part 90 Class B Industrial Booster (non-SMR)
Class B Booster
Equipment Class
B9B - Part 90 Class B Industrial Booster (non-SMR)
Class A Booster
Equipment Class
B9A - Part 90 Class A Industrial Booster (non-SMR)