Equipment Class
AMP - Amplifier
Date of Grant
Sep 23, 2003
Application Purpose
Original Equipment
Date of Application
Sep 23, 2003
Equipment Note
UHF Signal Extender
Frequency Range
457.70000000 - 458.75000000
Company
PBE Europe Ltd. trading as Axell Wireless
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗
↗

ID Label/Location Info

↗
↗

Internal Photos

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Operational Description

↗

Parts List/Tune Up Info

Schematics

↗

Test Report

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

5-Way Channelised UHF Cell Enhancer Maintenance Handbook H/book Number:-50-060601HBKM Issue No:- 1 Date:-04/07/2003 Page:- 1 of 54 5 Channel, Channelised Cell Enhancer Maintenance Handbook For AFL Works Order Nō.:Q108745 Includes AFL product part Nō’s.:50-060602Downlink Amplifier 50-060603Uplink Amplifier 50-060604Power Supply 5-Way Channelised UHF Cell Enhancer Maintenance Handbook H/book Number:-50-060601HBKM Issue No:- 1 Date:-04/07/2003 Page:- 2 of 54 Table of Contents AMENDMENT LIST RECORD SHEET................................................................................................. 4 INTRODUCTION....................................................................................................................................... 5 Scope...........................................................................................................................................................................5 Purpose.......................................................................................................................................................................5 Glossary of Terms.....................................................................................................................................................6 Key to AFL RF Module Drawing Symbols.............................................................................................................7 1.SAFETY CONSIDERATIONS....................................................................................................... 8 1.1Earthing of Equipment................................................................................................................................8 1.2Electric Shock Hazard.................................................................................................................................8 1.3RF Radiation Hazard...................................................................................................................................8 1.4Chemical Hazard..........................................................................................................................................9 1.5Emergency Contact Numbers.....................................................................................................................9 2.OVERVIEW/SYSTEM DESCRIPTION..................................................................................... 10 3.SPECIFICATION.......................................................................................................................... 11 3.15 Channel Channelised Cell Enhancer 50-060601 Parts Lists...............................................................11 3.1.1Downlink Channelised CE 50-060602 Parts List.....................................................................................11 3.1.2Uplink Channelised CE 50-060603 Parts List.........................................................................................12 3.1.3Power Supply Shelf 50-060604 Parts List...............................................................................................13 3.2Technical Specification..............................................................................................................................14 3.3Mechanical Specification...........................................................................................................................15 4.SYSTEM DRAWINGS.................................................................................................................. 16 4.1Drg. Nō. 50-060682, Downlink Amplifier Shelf System Diagram..........................................................16 4.2Drg. Nō. 50-060683, Uplink Amplifier Shelf System Diagram...............................................................17 4.3Drg. Nō. 50-060684, Power Supply Shelf System Diagram....................................................................18 5.SUB-UNIT MODULES.................................................................................................................. 19 5.1Downlink Channelised Cell Enhancer 60-060602 (5U chassis)..............................................................19 5.1.1Bandpass Filters (02-010701)..................................................................................................................19 5.1.1.1Description.......................................................................................................................................19 5.1.1.2Technical Specification....................................................................................................................19 5.1.2UHF 3dB Splitter (05-002603)................................................................................................................20 5.1.2.1Description.......................................................................................................................................20 5.1.2.2Technical Specification....................................................................................................................20 5.1.33dB UHF Splitter (05-002603)................................................................................................................21 5.1.3.1Description.......................................................................................................................................21 5.1.3.2Technical Specification....................................................................................................................21 5.1.4¼Watt 0- -30dB Switched Attenuator (10-000701).................................................................................21 5.1.4.1General Application.........................................................................................................................21 5.1.4.2Switched Attenuators........................................................................................................................21…

Text truncated - open the document above for the full version.

Block Diagram

5-Way Channelised UHF Cell Enhancer Maintenance Handbook H/book Number:-50-060601HBKM Issue No:- 1 Date:-04/07/2003 Page:- 16 of 54 4.SYSTEM DRAWINGS 4.1Drg. Nō. 50-060682, Downlink Amplifier Shelf System Diagram DOWNLINK CCE 80dB 10WSYSTEM DIAGRAM 50-060682 1A - MNR 30/06/03 BY DAT E DESCRIPT IO N No ISSUE 12 3 4 5 6 7 89 A BCDEF 1 23456789 A BCD E F Fax : 01494 777002 Tel : 01494 777000 Aerial Facilities Limited T HIS IS A PRO PRIET ARY DESIG N O F AERIAL F ACIL IT IES L T D.REPRO DUCT IO N O R USE O F T HIS DESIG N BY O T HERS ISPERM ISSIBL E O NL Y IF EXPRESSL Y AUT HO RISED IN WRIT INGBY AERIAL FACIL ITIES L TD. NO DECIM AL PL ACE ± 1 m mO NE DECIM AL PL ACE ± 0 .3 m mTWO DECIMAL PLACES ± 0.1mm AL L DIMENSIO NS ARE IN mm UNL ESS O THERWISE STATED CHKD DRAWN APPDDAT E TOLERANCES SCALE England CUST O MER DRAWING .No TITLE 3A dB BANDPASS FILTER 02-010701 453-454MHz LNA 11-007402 31dB GAIN ATTENUATOR 0-30dB 10-000701 11-007302 31dB GAIN LNA SPLITTER05-002603 05-003803SPLITTER 05-003803 COMBINER 05-002603 COMBINER 11-007302 LNA 21dB GAIN 28dB GAIN PA 12-001901 F REQ UENCY PRO G RAM M ING DAT A B/W=15kHz F REQ UENCY PRO G RAM M ING DAT A B/W=15kHz F REQ UENCY PRO G RAM M ING DAT A B/W=15kHz F REQ UENCY PRO G RAM M ING DAT A B/W=15kHz F REQ UENCY PRO G RAM M ING DAT A B/W=15kHz 5 x 17-003012 GAIN 20dB ALC -15dB CHANNEL MODULE 05-003803SPLITTER COMBINER 05-003803 BANDPASS FILTER 458-459MHz 02-010701 BASE A B P RODUCTION I S S UE MNR 30/06/03 5-Way Channelised UHF Cell Enhancer Maintenance Handbook H/book Number:-50-060601HBKM Issue No:- 1 Date:-04/07/2003 Page:- 17 of 54 4.2Drg. Nō. 50-060683, Uplink Amplifier Shelf System Diagram UPLINK CCE 80dB 10WSYSTEM DIAGRAM 50-060683 1A - MNR 30/06/03 BY DAT E DESCRIPT IO N No ISSUE 12 3 4 5 6 7 89 A BCDEF 1 23456789 A BCD E F Fax : 01494 777002 Tel : 01494 777000 Aerial Facilities Limited THIS IS A PRO PRIETARY DESIG N O F AERIAL FACIL ITIES L TD.REPRO DUCT IO N O R USE O F T HIS DESIG N BY O T HERS ISPERMISSIBL E O NL Y IF EXPRESSL Y AUTHO RISED IN WRITINGBY AERIAL FACIL ITIES L TD. NO DECIM AL PL ACE ± 1 m mO NE DECIMAL PL ACE ± 0 .3 mmTWO DECIMAL PL ACES ± 0 .1 mm AL L DIM ENSIO NS ARE IN m m UNL ESS O THERWISE STATED CHKD DRAWN APPDDAT E TO L ERANCES SCAL E England CUST O M ER DRAWING .No TITLE 3A dB BANDPASS FILTER 02-010701 458-459MHz LNA 11-007402 31dB GAIN A TTE NUA TOR 0-30dB 10-000701 11-007302 31dB GAIN LNA SPLITTER05-002603 05-003803SPLITTER 05-003803 COMBINER 05-002603 COMBINER 11-007302 LNA 21dB GAIN 28dB GAIN PA 12-001901 F REQ UENCY PRO G RAM M ING DAT A B/W=15kHz F REQ UENCY PRO G RAM M ING DAT A B/W=15kHz F REQ UENCY PRO G RAM M ING DAT A B/W=15kHz F REQ UENCY PRO G RAM M ING DAT A B/W=15kHz F REQ UENCY PRO G RAM M ING DAT A B/W=15kHz 5 x 17-003012 GAIN 20dBALC -15dB CHANNEL MODULE 05-003803SPLITTER COMBINER 05-003803 BANDPASS FILTER 453-454MHz 02-010701 A PRODUCTION ISSUE MNR 30/06/03 B MOBILE DC INJECTOR 21-001701 48V DC 453.750MHz453.200MHz453.500MHz453.600MHz453.300MHz SS GD 5-Way Channelised UHF Cell Enhancer Maintenance Handbook H/book Number:-50-060601HBKM Issue No:- 1 Date:-04/07/2003 Page:- 18 of 54 4.3Drg. Nō. 50-060684, Power Supply Shelf System Diagram PSU FOR 50-060602 AND 50-060603SYSTEM DIAGRAM 50-060684 1A - MNR 30/06/03 BY DAT E DESCRIPT IO N No ISSUE 12 3 4 5 6 7 89 A BCDEF 1 23456789 A BCD E F Fax : 01494 777002 Tel : 01494 777000 Aerial Facilities Limited THIS IS A PRO PRIETARY DESIG N O F AERIAL FACIL ITIES L TD.REPRO DUCT IO N O R USE O F T HIS DESIG N BY O T HERS ISPERMISSIBL E O NL Y IF EXPRESSL Y AUTHO RISED IN WRITINGBY AERIAL FACIL ITIES L TD. NO DECIM AL PL ACE ± 1 m mO NE DECIMAL PL ACE ± 0 .3 mmTWO DECIMAL PL ACES ± 0 .1 mm AL L DIM ENSIO NS ARE IN m m UNL ESS O THERWISE STATED CHKD DRAWN APPDDAT E TO L ERANCES SCAL E England CUST O M ER DRAWING .No TITLE 3A 110V AC 24V DC PSU 96-300054PSU 96-300056 110V AC 48V DC LNE 110V AC 24V DC TO 50-06060224V DC TO 50-06060348V DC TO 50-060603 FOR DC INJECTORS PRODUCTION ISSUE MNR 30/06/03 L NE + - EN L + - 1 + 2 -2 - 1 + 2 - 3 + CB1 3A3A CB2 SS GD

ID Label/Location Info

BY DAT E DESCRIPT ION No THI RD ANGLE PROJECTI ON 1 2 34 5 6 7 8 9 A BCDE F 12345678 9 A BCD E F Fax : 01494 777002 Tel : 01494 777000 Aerial Facilities Limited THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES LTD.REPRODUCT ION OR USE OF T HIS DESIGN BY OT HERS ISPERMISSIBLE ONLY IF EXPRESSLY AUTHORISED IN WRITINGBY AERIAL FACILITIES LTD. NO DECIMAL PLACE ± 1mmONE DECIMAL PLACE ± 0.3mmTWO DECIMAL PLACES ± 0.1mm ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED CHKD DRAWN APPDDAT E T OLERANCES SCALE England CUST OMER DRAWING.No TITLE ISSUE 3A FCC IDENT. LABEL POSITION RACK MOUNTED UNIT 80-312190 1A 1:5 DBS 30/9/03 PRODUCTION ISSUE 30/ 9/ 02 DBS Li m i t ed Aerial Facilities POWERALARM FCC IDENT. LABEL v oltage Hig h DANGER Heav y CAUTION Ae ria l Fa c ilitie sLim ited England BY DAT E DESCRIPT ION No ISSUE 1 2 34 5 6 7 8 9 A BCDE F 12345678 9 A BCD E F Fax : 01494 777002 Fax : 01494 777000 Aerial Facilities Limited THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES LTD.RE P RODUCT ION OR US E OF T HIS DE S IGN B Y OT HE RS ISPERMISSIBLE ONLY IF EXPRESSLY AUTHORISED IN WRITINGBY AERIAL FACILITIES LTD. NO DECIMAL PLACE ± 1mmONE DECIMAL PLACE ± 0.3mmTWO DECIMAL PLACES ± 0.1mm ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED CHKD DRAWN APPDDAT E T OLERANCES SCALE England CUST OMER DRAWING.No TITLE 3A FCC IDENT. LABEL POSITIONIP65 STEEL ENCLOSURE 80-312191 1A 1:8 DBS 30/9/03 PRODUCTION ISSUE 30/9/03 DBS PSU ALARM FCC IDENT. LABEL

Operational Description

5-Way Channelised UHF Cell Enhancer Maintenance Handbook H/book Number:-50-060601HBKM Issue No:- 1 Date:-04/07/2003 Page:- 10 of 54 2.OVERVIEW/SYSTEM DESCRIPTION The AFL Channel Selective Cell Enhancer is a 2-way on-band repeater. Various models are available to cover frequency bands from 50MHz to 3000MHz. Its main sphere of applications is in urban areas where the topology is such that shadows occur in the propagation pattern (for example within large buildings, conference centres and tunnels, etc.,) The Channel Selective Cell Enhancer is a 2-port device for direct connection to two antennas, usually a highly directional Yagi or similar aligned towards the base (donor) site and an omni-directional antenna to cover the mobiles. The frequency bands that are passed by the Cell Enhancer are set as per the specific customer requirements. AFL manufacture a wide range of Cell Enhancers, configured for each customer's specific requirements. Two basic physical variants are available, a rack mounted version to fit in a standard 19" rack and an environmentally sealed wall mounted version which requires no further enclosure. The rack-mounted version is usually supplied in 3 units, a power supply unit and 2 RF units (one containing each path). Each shelf/tray unit containing active modules has a ‘D.C. on’ indicator on the front panel and the PSU also has an ‘A.C. on’ indicator. The wall-mounted version is supplied in a single environmentally-protected case. Handles are provided for carrying the unit and the door is fitted with locks. A supply isolator switch is fitted inside the unit and there are ‘.DC. on’ and ‘Alarm on’ indicators on the outside of the door.

Schematics

5-Way Channelised UHF Cell Enhancer Maintenance Handbook H/book Number:-50-060601HBKM Issue No:- 1 Date:-04/07/2003 Page:- 19 of 54 5.SUB-UNIT MODULES 5.1Downlink Channelised Cell Enhancer 60-060602 (5U chassis) 5.1.1 Bandpass Filters (02-010701) 5.1.1.1 Description The bandpass filters are multi-section designs with a bandwidth dependent upon the passband frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with a passband design ripple of 0.1dB. The filters are of combline design, and are carefully aligned during manufacture in order to optimise the insertion loss, VSWR and intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports. Being passive devices, the bandpass filters should have an extremely long operational life and require no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module rather than attempt repair or re-tuning. No adjustments should be attempted without full network sweep analysis facilities to monitor both insertion loss and VSWR simultaneously. 5.1.1.2 Technical Specification PARAMETERSPECIFICATION Passband 453-454 MHz Insertion Loss 1.9 dB typical > 456 MHz > 55 dB Rejection > 458-459 MHz > 60 dB Power Rating 50 Watt Impedance 50 ohm VSWR Better than 1.2:1 5-Way Channelised UHF Cell Enhancer Maintenance Handbook H/book Number:-50-060601HBKM Issue No:- 1 Date:-04/07/2003 Page:- 20 of 54 5.1.2 UHF 3dB Splitter (05-002603) 5.1.2.1 Description The 3dB Splitter/Combiner used is a device for accurately matching two or more RF signals to single or multiple ports, whilst maintaining an accurate 50Ω load to all inputs/outputs and ensuring that the VSWR and insertion losses are kept to a minimum. Any unused ports will be terminated with an appropriate 50Ω load. 5.1.2.2 Technical Specification PARAMETERSPECIFICATION Frequency Range: 380 - 520 MHz Bandwidth: 140 MHz Inputs: 1 Outputs: 2 Insertion Loss: 3.5 dB (typical) Isolation: >18 dB Return Loss (VSWR) – Input: Better than 1.3:1 Return Loss (VSWR) – Output: Better than 1.3:1 Impedance: 50 ς Power Rating – Splitter: 20 Watts Power Rating – Combiner: 0.5 Watt Connectors: SMA female Size: 54 x 44 x 21 mm (including connectors) Weight: 200 g 5-Way Channelised UHF Cell Enhancer Maintenance Handbook H/book Number:-50-060601HBKM Issue No:- 1 Date:-04/07/2003 Page:- 21 of 54 5.1.3 3dB UHF Splitter (05-002603) 5.1.3.1 Description The 3dB Splitter/Combiner used is a device for accurately matching two or more RF signals to single or multiple ports, whilst maintaining an accurate 50Ω load to all inputs/outputs and ensuring that the VSWR and insertion losses are kept to a minimum. Any unused ports will be terminated with an appropriate 50Ω load. 5.1.3.2 Technical Specification PARAMETERSPECIFICATION Frequency Range: 400-500 MHz Power Rating: 5 Watts Insertion Loss: 5.2dB Typical VSWR: 1.2:1 Impedance: 50 Ohms Connectors: SMA Weight: <0.5Kgs Mechanical: Drawing No. 07-003890 5.1.4 ¼Watt 0- -30dB Switched Attenuator (10-000701) 5.1.4.1 General Application In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the gain. 5.1.4.2 Switched Attenuators The AFL switched attenuators are available in two different types; 0 – 30dB in 2 dB steps (as in this case), or 0 – 15dB in 1 dB steps. The attenuation is simply set using the four miniature toggle switches on the top of each unit. Each switch is clearly marked with the attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are designed to maintain an accurate 50Ω impedance over their operating frequency at both input and output. 5-Way Channelised UHF Cell Enhancer Maintenance Handbook H/book Number:-50-060601HBKM Issue No:- 1 Date:-04/07/2003 Page:- 22 of 54 5.1.5 Low Noise Amplifiers (11-007302 & 11-007402) 5.1.5.1 Description The low noise amplifiers used are double stage solid-state low-noise amplifiers. Class A circuitry is used in the units to ensure excellent linearity over a very wide dynamic range. The active devices are very moderately rated to provide a long trouble-free working life. There are no adjustments on these amplifiers, and in the unlikely event of failure then the entire amplifier should be replaced. The two amplifiers are very similar in construction, the only difference is the biasing, which changes the gain figure, see tables below. 5.1.5.2 Technical Specification, (11-007302) PARAMETERSPECIFICATION Frequency range: 380-500MHz Bandwidth: <140MHz Gain: 20-22dB 1dB Compression Point: +23.5dB (typical) 3rd order intercept: +36dB (typical) Input/Output return loss: >20dB Noise figure: <1.3dB Connectors: SMA female Supply: 200-230mA @ 24V DC operational: -10°C to +55°C Temperature range: storage: -30°C to +70°C Weight: <300gms Size: 90 x 55 x 30.2 (case only) 5.1.5.3 Technical Specification (11-007402) PARAMETERSPECIFICATION Frequency range: 380-500MHz Bandwidth: <140MHz Gain: 30-32dB 1dB Compression Point: +22dBm (typical) 3rd order intercept: +34-35dBm (typical) Input/Output return loss: >20dB Noise figure: <1.3dB Connectors: SMA female Supply: 300-330mA @ 24V DC operational:-10°C to +55°C Temperature range: storage: -30°C to +70°C Weight: <300gms Size: 90 x 55 x 30.2 (case only) 5-Way Channelised UHF Cell Enhancer Maintenance Handbook H/book Number:-50-060601HBKM Issue No:- 1 Date:-04/07/2003 Page:- 23 of 54 5.1.5.3 Drg. Nō. 11-007302, LNA Assembly With Alarm Relay BY DAT E DESCRIPT IO N No ISSUE 1 23 456 78 9 ABCDEF 1 2 3 4 5 6 7 8 9 FEDABC Fax : 01494 777002 Tel : 01494 777000 Aerial Facilities Ltd TWO DECIMAL PL ACES ± 0 .1 mmO NE DECIMAL PL ACE ± 0 .3 mmNO DECIM AL PL ACE ± 1 m m BY AERIAL F ACIL IT IES L T D.PERMISSIBL E O NL Y IF EXPRESSL Y AUTHO RISED IN WRITINGRE…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Michael Adam Godsey(VP of Design Engineering)
[email protected]2769881029Fax: 2769885892

Technical Contact

Aerial Facilities LimitedPeter Bradfield
[email protected]+441494777020

Aerial House, Asheridge Road · Buckinghamshire · United Kingdom

Non-Technical Contact

Aerial FacilitiesSteve Gallagher
[email protected]+441494777000

Test Firm

TRL EMC LimitedNeil Roche
[email protected]44-1684-833818Fax: 44-1684-833858

Technical Specifications

#Rule PartsFrequency RangePower OutputEmission
29457.7 MHz - 458.75 MHz200.00 mWF3E
Grant Notes
Power output shown is per channel at the antenna port. The antenna(s) used for this transmitter must be fixed-mounted on indoor/outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of �1.1307(b)(3).

Other Applications from PBE Europe Ltd. trading as Axell Wireless

BSF3604 - FCC ID NEO61-105SERIES - PBE Europe Ltd. trading as Axell Wireless
NEO61-105SERIES

BSF3604

Nov 27, 2022

Equipment Class

B9B - Part 90 Class B Industrial Booster (non-SMR)
MBF-37D7-3708 - FCC ID NEOA218DSERIES - PBE Europe Ltd. trading as Axell Wireless
NEOA218DSERIES

MBF-37D7-3708

Jul 14, 2022

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
Class B Booster - FCC ID NEO36IDRU420 - PBE Europe Ltd. trading as Axell Wireless
NEO36IDRU420

Class B Booster

May 06, 2020

Equipment Class

B9B - Part 90 Class B Industrial Booster (non-SMR)
Class B Booster - FCC ID NEODMBR37073708PS - PBE Europe Ltd. trading as Axell Wireless
NEODMBR37073708PS

Class B Booster

Jan 04, 2016

Equipment Class

B9B - Part 90 Class B Industrial Booster (non-SMR)
Class A Booster - FCC ID NEODMBA30073008PS - PBE Europe Ltd. trading as Axell Wireless
NEODMBA30073008PS

Class A Booster

Aug 30, 2015

Equipment Class

B9A - Part 90 Class A Industrial Booster (non-SMR)