Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
CSI-DSP85-C/P , CSI-DSP85I-C/ P & CSI-DSP85-201-C/P Installation Manual Table Of Contents Product Registration Information ........................................4 Document Purpose/Intended Users ....................................4 Application ......................................................................4 Safety Guidelines and Important Safety Information..............4-5 Terms Used in This Manual ...............................................5 Product Introduction .........................................................5 DSP Band Plan and Filter Naming Convention .......6-7 Functional Overview .............................................8 LED Indicators ....................................................8-9 Local Communications Interface Ports .....................10 Pin-out Chart .....................................................10 USB Interface .....................................................10 Ethernet .............................................................10 Monitoring & Alarms ............................................10 System Set-Up Considerations ............................11-12 Mounting the Repeater.........................................13 Optional Accessories ......................................................14 Important Installation Notes ............................................ 14 Circuit Description ........................................................ 14 Function Block Diagram .....................................15 Mechanical Specifications ..................................16 AC Power Specifications ....................................16 Operating Power Parameters ..............................17 Environmental Requirements ...............................17 Mechanical Drawing .......................................................18 Web Base GUI Session .................................................19-26 Text Menu Interface (Local Access,) ................................27-31 Telnet Session (Remote Access, Login Required) .............31-33 Modem Interface (Remote Access with Login) .................33 Additional Tips ..............................................................33-35 Product Warranty ..........................................................36 FCC Information ............................................................36 Index.............................................................................37 -4- Application This guide should be applied whenever a need exists to add Digital Repeater capability to an existing system or when this capability is being included with a new installation. Safety Guidelines The general safety information in this guideline applies to both operating and service personnel. Specific warnings and cautions will be found in other parts of this manual where they apply, but may not appear in this summary. Failure to comply with these precautions or specific warnings elsewhere in the manual violates safety standards of design, manufacture, and intended use of equipment. Cellular Specialties, Inc. assumes no liability for the customer’s failure to comply with these requirements: Grounding This Digital Repeater system is designed to operate from 100-240 VAC and should always be operated with the ground wire properly connected. Do not remove or otherwise alter the grounding lug on the power cord. Explosive Atmospheres To avoid explosion or fire, do not operate this product in the presence of flammable gases or fumes. Lightning Danger Do not install or make adjustments to this unit during an electrical storm. Use of a suitable lightning arrester, such as CSI’s model number CSI-CAP, is very strongly recommended. No User Serviceable Parts Inside HAZARDOUS VOLTAGES ARE PRESENT WHEN THE COVER IS REMOVED. Opening the chassis will void your warranty. If you suspect a malfunction with this product, call your dealer or the Cellular Specialties Support Line at: (603) 626-6677, Toll Free (USA) 1-877-844-4274. The serial number may be found on the label on the bottom panel, near the power connectors . Note this number below. Retain this manual, along with proof of pur- chase, to serve as a permanent record of your purchase. MODEL NUMBERSERIAL NUMBERDATE OF PURCHASE POINT OF SALE COMPANY Product Registration Information DISCLAIMER: All information and statements contained herein are accurate to the best of the knowledge of Cellular Specialties, Inc. (CSI), but Cellular Specialties makes no warranty with respect thereto, including without limitation any results that may be obtained from the products described herein or the infringement by such products of any proprietary rights of any persons. Use or application of such information or statements is at the users sole risk, without any liability on the part of Cellular Specialties, Inc. Nothing herein shall be construed as licence or recommendation for use, which infringes upon any proprietary rights of any person. Product material and specifications are subject to change without notice. Cellular Specialties’ standard terms of sale and the specific terms of any particular sale apply. Document Purpose / Intended Users The purpose of this document is to provide a step-by-step procedure to help the experienced technician/engineer install and commission an in-building wireless enhancement repeater system using CSI’s DSP85-C/P or DSP85I-C/P Digital Repeater. Following the procedures outlined will minimize risks associated with modifying a live system and prevent service interruptions. This document assumes the technician/engineer understands the basic prin- ciples and functionality involved with Repeater and in-building systems. It is geared to the practical concerns of the installer. - 5 - Product Introduction Cellular Specialties, Inc. (CSI) developed the DSP85 and DSP85I digital repeaters for use within enclosed structures where sufficient signal from local cell sites to operate cell phones is unavailable. Adequate signal must be available outside t…
Text truncated - open the document above for the full version.
March 29, 2010 Federal Communications Commission Office of Engineering and Technology 7435 Oakland Mills Rd. Columbia, MD 21046 Subject: Request for Confidentiality Dear Sir or Madam: Cellular Specialties, Inc. respectfully requests that the schematic diagrams, block diagram, and circuit descriptions submitted with the application for certification under FCC ID: NVRCSI-DSP85201CP be withheld from public disclosure. This request is made under the provisions of Section 0.457 (d) of the Commission’s rules and Section 0.552 (b) (4) of the Freedom of Information Act. This product has been developed at considerable expense, and disclosure of this information would place Cellular Specialties, Inc. at a competitive disadvantage. Thank you for your attention to this matter. Sincerely yours, Burt Salkins Burt Salkins Director of Engineering
October 17, 2007 Retlif Testing Laboratories 101 New Boston Road Goffstown, NH 03045 Attn: Scott Wentworth Ref: AGENT AUTHORIZATION/ANTI-DRUG ABUSE CERTIFICATION Dear Scott, Cellular Specialties, Inc. hereby authorizes Retlif Testing Laboratories, 101 New Boston Road, Goffstown, NH 03045 to act as our agent in all matters pertaining to FCC and Industry Canada Certification of our DSP85-CP Dual Band Bidirectional Amplifier. Cellular Specialties, Inc. (The Applicant) Certifies that neither Cellular Specialties, Inc. nor any party to the application is subject to denial of Federal benefits, that include FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862 because of a conviction for possession or distribution of a controlled substance. Sincerely, Burt Salkins Director of Engineering
MODEL DSP85201CP Frequency Programmable Repeater FCC ID LABEL FCC ID: NVRCSI-DSP85201CP IC: 4307A-DSP85201CP This device complies with parts 22 and/or 24 and 2 of the FCC rules and with Industry Canada specification RSS-131
October 17, 2007 Mr. Scott Wentworth Retlif Laboratories 101 New Boston Rd. Goffstown, NH 03045 Re: Adjustment of the Model DSP85-CP In-building Amplifier in the Field The CSI Model DSP85-CP In-Building Amplifier offers only adjustment of gain (below its factory-set maximum gain level) to the technician during installation and maintenance activities. This adjustment is dependent on the physical environment in which the amplifier is to be installed and is described in the Installation and Users Manual. This is the only adjustment accessible without opening the amplifier. Frequency response and gain thresholds are factory set and in no circumstance are they to be adjusted in the field. Regards, Burt Salkins Burt Salkins Director of Engineering
Evaluation of the CSI Model DSP85-201-CP BDA For Compliance with FCC Guidelines For Human Exposure to Radio Frequency Electromagnetic Fields 29 March 2010 Revised 14 April 2010 General The CSI Model DSP85-201-CP Bi-directional amplifier is considered to be a dual-band “mobile” device operating in both the Cellular Service authorized under subpart H of part 22 and in the Personal Communication Service authorized under part 24. As such, the equipment is required to be evaluated for RF exposure if operated below 1.5 GHz with an effective radiated power (ERP) of 1.5 watts or more or if operated above 1.5 GHz with an effective radiated power (ERP) of 3.0 watts or more, as defined in 2.1091 of FCC rules. Downlink For the downlink portion of the Model DSP85-201-CP BDA, the maximum rated output power is +30.01dbm (1002 mW) in the Cellular Band (<1.5 GHz) and 27.53 dBm (566 mW) in the PCS band (>1.5 GHz). As stated in the Model DSP85-201-CP Manual, the maximum authorized indoor antenna gain is 3 dBi, corresponding to a typical Multi- Band Omni-Directional antenna. The Table below shows the results of the calculated ERP for both cases, neglecting cable losses. Frequency Power Out Ant Gain EIRP ERP Limit 869-894 MHz 30.01 dBm 3 dBi 33.01 dBm 1219 mW 1.5 W 1930-1990 MHz 27.53 dBm 3 dBi 30.53 dBm 689 mW 3.0 W In both the above cases the ERP is well below the allowable limits excluding the downlink from routine evaluation. The Cautions in the Model DSP85-201-CP manual clearly define the antenna selection and installation criteria in order to maintain a minimum 20-centimeter separation. Uplink For the downlink portion of the Model DSP85-201-CP BDA, the maximum rated output power is +30.39dbm (1094 mW) in the Cellular Band (<1.5 GHz) and 28.47 dBm (703 mW) in the PCS band (>1.5 GHz). As stated in the Model DSP85-201-CP Manual, the maximum authorized outdoor antenna gain is 14 dBi, corresponding to a typical Multi- Element Yagi-Directional antenna. The Table below shows the results of the calculated ERP for both cases, neglecting cable losses. Frequency Power Out Ant Gain EIRP ERP Limit 824-849 MHz 30.39 dBm 14 dBi 44.39 dBm 16,755 mW 1.5 W 1850-1910 MHz 28.47 dBm 14 dBi 42.47 dBm 10,768 mW 3.0 W As shown in the above table, the Cellular and PCS band exceeds the allowable limit and must be evaluated for minimum separation distances in order to comply with the exposure limits of 1.1310 of the FCC rules. Using the guidelines in FCC OET Bulletin 65 and Supplement C, the power density at a reasonable distance from the maximum gain antenna was calculated. The minimum safe distance was also determined based on the uncontrolled exposure limits defined in Table 1B of FCC rules 1.1311. The following assumptions are made concerning these calculations: Cellular Band PCS Band Po = 1094 mw average 703 mw Cable Loss = 0 dB 0 dB Ant Gain = 14 dBi 14 dBi Frequency = 836.5 MHz 1920 MHz Main Beam (worst-case) Main Beam Rooftop 100% reflection Rooftop Reasonable Distance = 6 feet (183 cm) 6 feet Therefore, from OET Bulletin 65, S = (PG)/4πR 2 or S = EIRP/4πR 2 For 100% reflection, a doubling of the field strength can be expected. The above equation can be modified to, S = (2) 2 PG/4πR 2 = EIRP/πR 2 Solving for S at a distance of 6 feet (183 cm) gives, Cellular PCS S = (1094) (25)/ π (183) 2 = 0.26 mw/cm 2 S = (703) (25)/ π (183) 2 = 0.17 mw/cm 2 From FCC rules 1.1311, Table 1B, the allowable limit for uncontrolled exposure is f(MHz) / 1500. At 836.5 MHz this corresponds to a level of 0.56 mw/cm 2 . For frequencies above 1500 MHz the limit is 1.0 mw/cm 2 . The calculated values of 0.26 and 0.17 are below both these limits thereby showing compliance under worst-case operating conditions. As in the case of the downlink, the Cautions in the Model DSP85-201-CP manual clearly define the antenna selection and installation criteria in order to maintain a conservative 6- foot separation.
Test Report No. R-5276N FCC ID: NVRCSI-DSP85201CP Certification and Signatures We certify that this report is a true report of the results obtained from the tests of the equipment stated and relates only to the equipment tested. We further certify that the measurements shown in this report were made in accordance with the procedures indicated and vouch for the qualifications of all Retlif Testing Laboratories personnel taking them. Scott Wentworth Branch Manager NVLAP Approved Signatory Todd Hannemann Laboratory Supervisor Non-Warranty Provision The testing services have been performed, findings obtained, and reports prepared in accordance with generally accepted testing laboratory principles and practices. This warranty is in lieu of all other warranties, either express or implied. Non-Endorsement This test report contains only findings and results arrived at after employing the specific test procedures and standards listed herein. It is not intended to constitute a recommendation, endorsement, or certification of the product or material tested. This report must not be used by the client to claim product endorsement by NVLAP, NIST or any agency of the U.S. Government. Page 2 of 78 Test Report No. R-5276N FCC ID: NVRCSI-DSP85201CP CERTIFICATION APPLICATION SUMMARY Applicant/Manufacturer: Cellular Specialties 670 North Commercial Street Manchester, NH 03101 Equipment under Test (EUT): The EUT is a Dual Band Bi-Directional Amplifier Model: DSP85-C/P/DSP85-CP FCC ID Number: FCC ID: NVRCSI-DSP85201CP Applicable Test Standard: FCC Parts 2, 22 & 24 Measurement Procedure: ANSI/TIA-603-C-2004 Device Classification: Mobile EUT Frequency Range Band: Cell Band Uplink: 824MHz TO 849MHz Cell Band Downlink: 869MHz TO 894MHz PCS Band Uplink: 1850MHz to 1910MHz PCS Band Downlink: 1930MHz to 1990MHz Power Output Ratings Based 824MHz to 849MHz (IS-95 CDMA): = .711W on Intermodulation Data Composite 824MHz to 849MHz (W-CDMA): = .817W Power (For Certification Grant): 824MHz to 849MHz (GSM): = 1.09W 869MHz to 894MHz (IS-95 CDMA) = .621W 869MHz to 894MHz (W-CDMA) = .695W 869MHz to 894MHz (GSM) = 1.00W 1850MHz to 1910MHz (IS-95 CDMA) = .382W 1850MHz to 1910MHz (W-CDMA) = .399W 1850MHz to 1910MHz (GSM CDMA) = .703W 1930MHz to 1990MHz (IS-95 CDMA) = .419W 1930MHz to 1990MHz (W-CDMA) = .367W 1930MHz to 1990MHz (GSM) = .566W Modulation Type: GSM (F1D), IS95-CDMA (F9W), W-CDMA (F9W) RF Exposure + Antenna Installation: See Attached Installation/Users Manual and MPE Evaluation Page 3 of 78 Test Report No. R-5276N FCC ID: NVRCSI-DSP85201CP Measurements Required by FCC: See Report Section 1 (Summary of Test Program) and the following Test Report Data Attachments: -RF Power Output -Intermodulation Characteristics (Two-Tone) -Occupied Bandwidth -Spurious Emissions at Antenna Terminals -Effective Radiated Power of Spurious Radiation -Frequency Stability SECTION 1 SUMMARY OF TEST PROGRAM INTERMODULATION CHARACTERISTICS (TWO TONE) Measurement Procedure: Two signals were injected, in turn, to each uplink and downlink frequency band via a two way power combiner. Testing was performed at both the low band edge and high band edge of each pass band. The output of each signal generator was adjusted so that the two output fundamental frequencies were equal in magnitude. Testing was performed for GSM, IS95-CDMA & W-CDMA Modulation types. At the maximum specified input power levels all intermodulation products were at -13dBm or below for each modulation. See attached test data. OCCUPIED BANDWIDTH Measurement Procedure: For Occupied Bandwidth, measurements were made to compare the input signal to the output signal. The signal generator output was connected to the spectrum analyzer. A IS95-CDMA modulation signal was then applied to the carrier. Waveforms were then noted on an X-Y plot. Next, the signal generator was connected to the EUT and the output of the EUT was connected to the spectrum analyzer. The output waveform after amplification was then compared to the original input signal to ensure that no significant differences occurred between the input signal and the amplified signal. Testing was performed at one frequency within each passband (uplink and downlink). Testing was repeated with GSM and W-CDMA Modulation. See Occupied Bandwidth Data. An explanation of the data is as follows: There are two signals superimposed on each plot, one signal is the waveform before modulation, the other is the modulated carrier. In each case the center of the grid shows a narrowband signal projecting out from the center of the modulation envelope. This signal is actually the stored unmodulated signal. Page 4 of 78 Test Report No. R-5276N FCC ID: NVRCSI-DSP85201CP SPURIOUS EMISSIONS AT ANTENNA TERMINALS Measurement Procedure: The signal generator output was connected in turn to the uplink and downlink input ports of the EUT. The input power level was at the maximum level which was ascertained during the Power Output test. A spectrum analyzer was connected to the output of the EUT. The input test frequencies used were three frequencies (low, mid & high) within each passband (cell & pcs uplink and downlink). The level of any spurious emission was recorded. Testing was performed in the frequency range of 30MHz to 20GHz. Testing was performed for GSM, IS95-CDMA & W- CDMA modulation types. The spurious emissions limit is -13dBm as specified in FCC Parts 22 & 24. All emissions were below the specified -13dBm limit. See attached test data. EFFECTIVE RADIATED POWER OF SPURIOUS RADIATION Measurement Procedure: The test sample was placed on a 80cm high wooden test stand which was located 3 meters from the test antenna on an FCC listed test site. A signal generator was connected to the input of the amplifier. The signal generator output was set to provide the input power level necessary to achieve maximum output power of the amplifier at 3 frequencies (low, mid & high) within each passband (cell & pcs uplink and downlink). The effective radiated power of ea…
Text truncated - open the document above for the full version.
Test Report No. R-5276N FCC ID: NVRCSI-DSP85201CP SETUP PHOTOGRAPHS SPURIOUS RADIATED EMISSIONS Page 8 of 78 Test Report No. R-5276N FCC ID: NVRCSI-DSP85201CP SPURIOUS RADIATED EMISSIONS Page 9 of 78 Test Report No. R-5276N FCC ID: NVRCSI-DSP85201CP SPURIOUS RADIATED EMISSIONS Page 10 of 78 Test Report No. R-5276N FCC ID: NVRCSI-DSP85201CP SPURIOUS EMISSIONS AT ANTENNA TERMINALS OCCUPIED BANDWIDTH/RF POWER OUTPUT INTERMODULATION (TWO TONE) Page 11 of 78 Test Report No. R-5276N FCC ID: NVRCSI-DSP85201CP FREQUENCY STABILITY Page 12 of 78 Test Report No. R-5276N FCC ID: NVRCSI-DSP85201CP FREQUENCY STABILITY Page 13 of 78
101 New Boston Road · Goffstown · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 12 | 24E | 1.93 GHz - 1.99 GHz | 566.00 mW | GXW | Amp |

700/800 MHZ DUAL BAND INDUSTRIAL BOOSTER
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
AWS Repeater
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
The Co-Pilot Beacon C4
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
THE CO-PILOT BEACON P4
Equipment Class
PCB - PCS Licensed Transmitter
The Co-Pilot Beacon
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter