Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
CSI-DSP95-252-AW, CSI-DSP95I-252-AW, CSI-DSP95-255-AW, and CSI-DSP95I-255-AW -2- This page left intentionally blank. Table of Contents Product Registration Information ................................................................................................................... 4 Document Purpose / Intended Users.............................................................................................................. 4 Application ........................................................................................................................................................ 4 Radio and Television Interference .................................................................................................................. 4 Safety Guidelines ............................................................................................................................................. 4 Important Safety Information .......................................................................................................................... 5 Terms used in this manual .............................................................................................................................. 5 Product Introduction ........................................................................................................................................ 5 Band Plan and Filter Naming Convention ...................................................................................................... 6 Filter File Naming Convention ......................................................................................................................... 6 Functional Overview ........................................................................................................................................ 7 LED Indicator .................................................................................................................................................... 7 Local Communication Interface Ports ............................................................................................................ 8 EIA232 Pin Specifi cations................................................................................................................................ 8 USB Interface .................................................................................................................................................... 8 Ethernet ............................................................................................................................................................. 8 Monitoring & Alarms ........................................................................................................................................ 9 System Set-Up Considerations ....................................................................................................................... 9 Selection of external attenuators to be used in line with the Antenna Port(s) ........................................... 9 1:1 Port Confi guration ..................................................................................................................................... 9 Donor Port ....................................................................................................................................................... 10 Server Port ...................................................................................................................................................... 10 Attenuator Selection Guidelines ................................................................................................................... 10 Mounting the Digital Repeater ........................................................................................................................11 Wall Mounting .................................................................................................................................................11 19” Relay Rack Mounting ..............................................................................................................................11 19” Four Post Rack Mounting .......................................................................................................................11 Important Installation Notes .......................................................................................................................... 12 Installation Tips .............................................................................................................................................. 12 Donor Antenna ................................................................................................................................................ 12 Indoor Antennas ............................................................................................................................................. 12 Optional Accessories ..................................................................................................................................... 12 Circuit Operational Description .................................................................................................................... 13 Functional Block Diagram ............................................................................................................................. 13 Mechanical Specifi cations ............................................................................................................................. 14 Environmental Requirements........................................................................................................................ 14 AC Power Specifi cations ............................................................................................................................... 14 Operating Power Parameters .....................................................................…
Text truncated - open the document above for the full version.
MODEL CSI-DSP95-255-AW Repeater FCC ID LABEL FCC ID: NVRCSIDSP95255AW This device complies with parts 27 and 2 of the FCC rules and Industry Canada IC: 4307A-DSP95255AW Model No: CSI-DSP95-255-AW
Evaluation of the CSI Model CSI-DSP95-255-AW BDA For Compliance with FCC Guidelines For Human Exposure to Radio Frequency Electromagnetic Fields 26 October 2011 General The CSI Model CSI-DSP95-255-AW Bi-directional amplifier is considered to be a dual- band “mobile” device operating in both the Cellular Service authorized under part 27. As such, the equipment is required to be evaluated for RF exposure if operated below 1.5 GHz with an effective radiated power (ERP) of 1.5 watts or more or if operated above 1.5 GHz with an effective radiated power (ERP) of 3.0 watts or more, as defined in 2.1091 of FCC rules. Downlink For the downlink portion of the Model CSI-DSP95-255-AW BDA, the maximum rated output power is +35.9dBm (3880 mW) in the 2100 MHz band (>1.5 GHz). As stated in the Model CSI-DSP95-255-AW Manual, the maximum authorized indoor antenna gain is 3 dBi, corresponding to a typical Multi-Band Omni-Directional antenna. The Table below shows the results of the calculated ERP, neglecting cable losses. Frequency Power Out Ant Gain EIRP ERP Limit 2110-2155 MHz 35.9dBm 3 dBi 38.9dBm 4,732 mW 1.5 W As shown in the above table, the level exceeds the allowable limit and must be evaluated for minimum separation distances in order to comply with the exposure limits of 1.1310 of the FCC rules. Using the guidelines in FCC OET Bulletin 65 and Supplement C, the power density at a reasonable distance from the maximum gain antenna was calculated. The minimum safe distance was also determined based on the uncontrolled exposure limits defined in Table 1B of FCC rules 1.1311. The following assumptions are made concerning these calculations: 2100 MHz Band Po = 3880 mw average Cable Loss = 0 dB Ant Gain = 3 dBi Frequency = 2132.5 MHz Main Beam (worst-case) 100% reflection Reasonable Distance = 4 feet (122 cm) Therefore, from OET Bulletin 65, S = (PG)/4R 2 or S = EIRP/4R 2 For 100% reflection, a doubling of the field strength can be expected. The above equation can be modified to, S = (2) 2 PG/4R 2 = EIRP/R 2 Solving for S at a distance of 4 feet (122 cm) gives, S = (3880) (2)/ (122) 2 = 0.17 mw/cm 2 From FCC rules 1.1311, Table 1B, the allowable limit for uncontrolled exposure for frequencies above 1500 MHz is 1.0 mw/cm 2 . The calculated value of 0.17 is below the limit thereby showing compliance under worst- case operating conditions. The Cautions in the Model CSI-DSP95-255-AW manual clearly define the antenna selection and installation criteria in order to maintain a minimum 4 feet (122 cm) separation. Uplink For the uplink portion of the Model CSI-DSP95-255-AW BDA, the maximum rated output power is +27.84dBm (608 mW) in the 1700 MHz Band (>1.5 GHz). As stated in the Model CSI-DSP95-255-AW Manual, the maximum authorized outdoor antenna gain is 14 dBi, corresponding to a typical Multi-Element Yagi-Directional antenna. The Table below shows the results of the calculated ERP for this case, neglecting cable losses. Frequency Power Out Ant Gain EIRP ERP Limit 1710-1755 MHz 27.84 dBm 14 dBi 41.84 dBm 9311 mW 1.5 W As shown in the above table, the level exceeds the allowable limit and must be evaluated for minimum separation distances in order to comply with the exposure limits of 1.1310 of the FCC rules. Using the guidelines in FCC OET Bulletin 65 and Supplement C, the power density at a reasonable distance from the maximum gain antenna was calculated. The minimum safe distance was also determined based on the uncontrolled exposure limits defined in Table 1B of FCC rules 1.1311. The following assumptions are made concerning these calculations: 1700 MHz Band Po = 608 mw average Cable Loss = 0 dB Ant Gain = 14 dBi Frequency = 1732.5 MHz Main Beam (worst-case) Rooftop 100% reflection Reasonable Distance = 6 feet (183 cm) Therefore, from OET Bulletin 65, S = (PG)/4R 2 or S = EIRP/4R 2 For 100% reflection, a doubling of the field strength can be expected. The above equation can be modified to, S = (2) 2 PG/4R 2 = EIRP/R 2 Solving for S at a distance of 6 feet (183 cm) gives, S = (608) (25)/ (183) 2 = 0.15 mw/cm 2 From FCC rules 1.1311, Table 1B, the allowable limit for uncontrolled exposure for frequencies above 1500 MHz is 1.0 mw/cm 2 . The calculated value of 0.15 is below both the limit thereby showing compliance under worst-case operating conditions. The Cautions in the Model CSI-DSP95-255-AW manual clearly define the antenna selection and installation criteria in order to maintain a conservative 6 feet (183 cm) separation.
Test Report No. R-5522N Retlif Testing Laboratories R CERTIFICATION AND SIGNATURES We certify that this report is a true report of the results obtained from the tests of the equipment stated and relates only to the equipment tested. We further certify that the measurements shown in this report were made in accordance with the procedures indicated and vouch for the qualifications of all Retlif Testing Laboratories personnel taking them. Scott Wentworth Branch Manager NVLAP Approved Signatory Todd Hannemann Laboratory Supervisor iNARTE Certified ATL-0255-T Non-Warranty Provision The testing services have been performed, findings obtained, and reports prepared in accordance with generally accepted testing laboratory principles and practices. This warranty is in lieu of all other warranties, either express or implied. Non-Endorsement This test report contains only findings and results arrived at after employing the specific test procedures and standards listed herein. It is not intended to constitute a recommendation, endorsement, or certification of the product or material tested. This report must not be used by the client to claim product endorsement by NVLAP, NIST or any agency of the U.S. Government. Page 2 of 71 Test Report No. R-5522N Retlif Testing Laboratories R CERTIFICATION APPLICATION SUMMARY Applicant/Manufacturer: Cellular Specialties 670 North Commercial Street Manchester, NH 03101 Equipment under Test (EUT): The EUT is a Digital Repeater System operating in the AWS band Model: CSI-DSP95-255-AW FCC ID Number: NVRCSIDSP95255AW IC Certification Number: 4307A-DSP95255AW Applicable Test Standards: FCC Parts 2 & 27, RSS-131, Issue 2 Measurement Procedure: ANSI/TIA-603-C-2004 RSS-131, Issue 2 Device Classification: Mobile EUT Frequency Range Band: Uplink: 1710 MHz to 1755 MHz Downlink: 2110 MHz to 2155MHz Power Output Rating for Uplink (WCDMA): 0.608W Certification Grant based on Uplink (LTE): 0.606W RMS Channel Power Downlink (WCDMA): 3.88W Downlink (LTE): 2.95W Modulation Types: WCDMA (F9W), LTE (F9W) RF Exposure + Antenna Installation: See Attached Installation/Users Manual and MPE Evaluation Measurements Required by FCC: See Report Section 1 (Summary of Test Program) and the following Test Report Data Attachments: - RF Power Output (27.50) - Occupied Bandwidth (2.1049) - Spurious Emissions at Antenna Terminals (27.53) - Effective Radiated Power of Spurious Radiation (27.53) - Intermodulation Characteristics - Frequency Stability (27.54) Additional Measurements Required by RSS -131: - Mean Output Power - Passband Gain & Bandwidth - Spurious Emissions (two tone) Page 3 of 71 Test Report No. R-5522N Retlif Testing Laboratories R SECTION 1 SUMMARY OF TEST PROGRAM RF POWER OUTPUT Measurement Procedure: The RF Power Output test was performed using RMS composite channel power measurements. The measurements were taken with the AGC turned off at maximum output power with all spurious emissions below the -13dBm limit. Testing was repeated with LTE modulation. The measured output power matched the manufacturer’s rated output power. See attached test data. OCCUPIED BANDWIDTH Measurement Procedure: For Occupied Bandwidth, measurements were made to compare the input signal to the output signal. The signal generator output was connected to the spectrum analyzer. A WCDMA modulation signal was then applied to the carrier. Waveforms were then noted on an X-Y plot. Next, the signal generator was connected to the EUT and the output of the EUT was connected to the spectrum analyzer. The output waveform after amplification was then compared to the original input signal to ensure that no significant differences occurred between the input signal and the amplified signal. Testing was performed at three frequencies within each passband (uplink and downlink). Testing was repeated with LTE Modulation. See Occupied Bandwidth Data. SPURIOUS EMISSIONS AT ANTENNA TERMINALS Measurement Procedure: The signal generator output was connected in turn to the uplink and downlink input ports of the EUT. The input power level was at the maximum level which was ascertained during the Power Output test. A spectrum analyzer was connected to the output of the EUT. The input test frequencies used were three frequencies (low, mid & high) within each passband (uplink and downlink). The level of any spurious emission was recorded. Testing was performed in the frequency range of 30MHz to 22GHz. Testing was performed for both WCDMA and LTE modulation types. The spurious emissions limit is -13dBm as specified in FCC Part 27. All emissions were below the specified - 13dBm limit. See attached test data. Page 4 of 71 Test Report No. R-5522N Retlif Testing Laboratories R EFFECTIVE RADIATED POWER OF SPURIOUS RADIATION Measurement Procedure: The test sample was placed on an 80cm high wooden test stand which was located 3 meters from the test antenna on an FCC listed test site. A signal generator was connected to the input of the amplifier. The signal generator output was set to provide the input power level necessary to achieve maximum output power of the amplifier at 3 frequencies (low, mid & high) within each passband (uplink and downlink). The effective radiated power of each out of band spurious emission was measured using the substitution method specified in ANSI/TIA-603-C-2004. The frequency range of the test was 30MHz – 22GHz. The limit for out of band spurious emissions is -13dBm as specified in Part 27. All emissions were below the specified -13dBm limit. See attached test data. INTERMODULATION CHARACTERISTICS (TWO TONE) Measurement Procedure: Two signals were injected, in turn, to each uplink and downlink frequency band via a two way power combiner. Due to the bandwidth of the modulated signals testing was performed with the two signals centered in the passband instead of at both the upper and lower band edges. The output of each signal generator was adjusted so that the two output fundamental frequencies were equal in magnitud…
Text truncated - open the document above for the full version.
101 New Boston Road · Goffstown · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 27 | 2.11 GHz - 2.15 GHz | 3.88 W | F9W | Amp |

700/800 MHZ DUAL BAND INDUSTRIAL BOOSTER
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
AWS Repeater
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
The Co-Pilot Beacon C4
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
THE CO-PILOT BEACON P4
Equipment Class
PCB - PCS Licensed Transmitter
The Co-Pilot Beacon
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter