FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Lionda Technology Co Ltd/
  3. O63M40002

O63M40002900 MHz Analog Modulation Cordless Telephone

Lionda Technology Co Ltd
900 MHz Analog Modulation Cordless Telephone - FCC ID O63M40002 - Lionda Technology Co Ltd
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Dec 28, 2000
Application Purpose
Original Equipment
Date of Application
Dec 28, 2000
Equipment Note
900 MHz Analog Modulation Cordless Telephone
Frequency Range
926.11700000 - 927.28800000
Company
Lionda Technology Co Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

โ†—
โ†—

Block Diagram

โ†—

Cover Letter(s)

โ†—

External Photos

โ†—
โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—

Operational Description

โ†—

Schematics

โ†—

Test Report

โ†—
โ†—
โ†—

Test Setup Photos

โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Test Report

FCC ID: O63M40002 Inte rte k Te sting Se rvice s Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2741 1693 November 20, 2000 Lionda Technology Co., Ltd. Blk. 2, Laodong 2nd Indโ€™l. Area, Xixian, Baoan, Shenzhen, China. Tel.:86 755 7917824 Fax.:86 755 7917944 Dear Mr. Dan: Enclosed you will find your file copy of a Part 15 Certification (FCC ID: O63M40002). We have forwarded the original to the TCB. For your reference, TCB will normally take another 15-20 days for reviewing the report. Approval will then be granted when no query is sorted. Please contact me if you have any questions regarding the enclosed material. Sincerely, Wilson Loke Manager Enclosure โ€ข The test results rep orted in this rep ort shall refer only to the samp le actually tested and shall not refer or be deemed to refer to bulk from which such a samp le may be said to have been obtained. โ€ข This rep ort shall not be rep roduced excep t in full without p rior authorization form Intertek Testing Services Limit ed FCC ID: O63M40002 Inte rte k Te sting Se rvice s Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2741 1693 Lionda Technology Co., Ltd. Application For Certification 900MHz Analog Modulation Cordless Telephone (FCC ID: O63M40002) WO# 0012258 SKL/kid November 20, 2000 INTERTEK TESTING SERVICES FCC ID: O63M40002 i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1:General Description EXHIBIT 2:System Test Configuration EXHIBIT 3:Emission Results EXHIBIT 4:Equipment Photographs EXHIBIT 5:Product Labelling EXHIBIT 6:Technical Specifications EXHIBIT 7:Instruction Manual EXHIBIT 8:Security Code Information INTERTEK TESTING SERVICES FCC ID: O63M40002 ii MEASUREMENT/TECHNICAL REPORT Lionda Technology Co., Ltd. - MODEL: BellSouth MH9012 FCC ID: O63M40002 This report concerns (check one:) Original Grant X Class II Change Equipment Type : Cordless Telephone (example : computer, modem, transmitter, etc.) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?Yes No X If yes, defer until : date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37 ?Yes No X If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [ 10-1-99 Edition ] Provision. Report prepared by:Wilson Loke Intertek Testing Services. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Phone :852-2173-8575 Fax:852-2741-1693 INTERTEK TESTING SERVICES FCC ID: O63M40002 iii Table of Contents 1.0 General Description ................................................................................................................ 6 1.1 Product Description ............................................................................................................... 6 1.2 Related Submittal(s) Grants ................................................................................................... 7 1.3 Test Methodology .................................................................................................................. 7 1.4 Test Facility............................................................................................................................ 7 2.0 System Test Configuration ...................................................................................................... 9 2.1 Justification ............................................................................................................................ 9 2.2 EUT Exercising Software ....................................................................................................... 9 2.3 Support Equipment List and Description ............................................................................. 10 2.4 Equipment Modification ......................................................................................................11 3.0 Emission Results .................................................................................................................... 13 3.1 Field Strength Calculation .................................................................................................... 14 3.2 Radiated Emission Configuration Photograph - Base Unit .................................................. 15 3.3 Radiated Emission Data - Base Unit .................................................................................... 16 3.4 Radiated Emission Configuration Photograph - Handset..................................................... 19 3.5 Radiated Emission Data - Handset....................................................................................... 20 3.6 Radiated Emission on the bandedge .................................................................................... 23 3.7 Line Conducted Configuration Photograph - Base Unit ..................................................... 25 3.8 Line Conducted Data - Base Unit ........................................................................................ 26 4.0 Equipment Photographs ....................................................................................................... 29 5.0 Product Labelling .................................................................................................................. 31 6.0 Technical Specifications ........................................................................................................ 33 7.0 Instruction Manual ................................................................................................................ 35 8.0 Security Code Information ................................................................................................... 37 INTERTEK TESTING SERVICES FCC ID: O63M40002 iv List of attached file Exhibit typeFile Descriptionfilename Cover LetterLetter of Agencyletter.pdf Test ReportTest Reportreport.doc Operation DescriptionTecโ€ฆ

Text truncated - open the document above for the full version.

Contact Information

Applicant

Dan Coronia(Senior Engineer)
[email protected]86-755-791-7824Fax: 86-755-791-7944

Technical Contact

Intertek Testing Services Hong Kong Ltd.Wilson Loke
[email protected]852-2713-8575

2/F., Garment Centre, ยท Kowloon ยท Hong Kong

Non-Technical Contact

Intertek Testing Services Hong Kong Ltd.Wilson Loke
[email protected]852-2713-8575

Test Firm

Intertek Testing Services Hong KongBilly Chow
[email protected]852-2173-8528Fax: 852-2371-0914

Technical Specifications

#Rule PartsFrequency RangePower Output
215C926.117 MHz - 927.288 MHz-

Other Applications from Lionda Technology Co Ltd

Digital Cordless Phone ๏ฟฝ Handset Unit - FCC ID O63GH5850HDLD03 - Lionda Technology Co Ltd
O63GH5850HDLD03

Digital Cordless Phone ๏ฟฝ Handset Unit

May 23, 2004

Equipment Class

DTS - Digital Transmission System
Analog Cordless Phone - FCC ID O63GH5815BALD04 - Lionda Technology Co Ltd
O63GH5815BALD04

Analog Cordless Phone

Apr 15, 2004

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Analog Cordless Phone - FCC ID O63GH5815HALD04 - Lionda Technology Co Ltd
O63GH5815HALD04

Analog Cordless Phone

Apr 15, 2004

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2.4GHz Digital Spread-Spectrum Cordless Phone - FCC ID O63PM3320DLD04 - Lionda Technology Co Ltd
O63PM3320DLD04

2.4GHz Digital Spread-Spectrum Cordless Phone

Apr 05, 2004

Equipment Class

DTS - Digital Transmission System
2.4GHz Digital Spread-Spectrum Cordless Phone - FCC ID O63PM3375DLD04 - Lionda Technology Co Ltd
O63PM3375DLD04

2.4GHz Digital Spread-Spectrum Cordless Phone

Mar 29, 2004

Equipment Class

DTS - Digital Transmission System