
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
l9915bmn.sch-1 - Fri Sep 22 09:08:32 2000 P02 SHEET: 1 OF 1 DATE: TITLE : APPROVED CHECKED DRAWING DESIGN REV C SIZE: R+ AI CLK DISTB T+ SQAO MH9915(V2) BASE SCHEMATIC 25-AUGUST-2000 5V C6 103 C7 103 C12 390P C16 473 R36 470K C18 100P R39 47 C19 104 C20 104 R40680K R41 240K D7 1N4148 C21 10P R42 3.3K R4339K C23 0.47uF C241uF C25 0.47uF R44 12K R45 22K R46 22K R47 22K C26 5N6 C27 1N2 C28 330P C29 10N R48 33K R49 10K C30 470P R50 100K Q3 A539Y R51 10K R52 47K C31 220uF SW1 T/P R54 100K C32 39P(CH) C33 39P(CH) J1 DCJACK C34 10N C36 NA R55 4.7K R56 100K Z1 210Vac J2 MODJACK 6 54 3 21 HYB1 SML-101 R57 82 R58 3.3K R59 2.7K R60 3.3K R61 2.7K R62 100K R64 10K VCC EO ERC DO EPI- EPI+ EB EMUTE BYPATH CMUTEGND CB CPI+ CPI- CRC AGIC DI CO FI FO 1 2 3 4 5 6 7 8 9 10 14 15 16 17 18 19 20 11 12 13 IC4 DBL5015 D9 1N4148 SW2 PAGE R65 10 1/2W D10 1N4003 R67 220K Q5 C945G R68 47 R69 68 R703.9K FUSE1 0.5A/300V R71 220K R72 680K C37 473 L1 10uH L2 10uH L3 10UH L4 10UH C39 100N C40 222M/400V R73560 R7447K R75 82K C42 100N R76 820K R79 22K C43 47uF 1 3 2 IC5 LM7805 Q7 C945G C45 100N X1 3.58MHZ R81 820K C46 100N C52 103 R90 20K R91 10K R92 22K C5315N C54 104 C55 123 C56 100N R93 10/1W Q9 C945G LED1 INUSE/CHARG R94 3.3K D11 5.6V C59 10uF R96 33K R97 100K Q10 A539Y R98 47K R99 10K R100 22M R101 22M R106 68K R107 68K C62 103M/400V C63 470uF D12 1N4004 D13 1N4004 D14 1N4004 D15 1N4004 C65 100N R108 NA R109 NA R1 22M R2 22M R5 22/1W R6 2.2M R7 2.2M R8 180K R9 180K C210uF R15 33K R16 33K C3 100P R3 180K R20 47K C11 473 R23 100K R2533K R27 47K R2933K C10 473 4 11 IC1E KA324 4 11 IC2E KA324 R12 47K D1 1N4148 D2 1N4148 R13 33K R35 39K R34 22K 1 VREF 2 IN1+ 3 IN1- 4 GS1 5 GND 6 OSIN 7 OSOUT 8 CB0 9 DCLK 10 DATA 11 DR/STD 12 EST 13 ST/GT 14 CD/STRDT 15 VCC 16 CB1 17 CB2 18 GS2 19 IN2- 20 IN2+ IC8 NW6006 R30 470K C22 270P R22 100K Q2 945G C35 473 R37 220K R19 1M R21 100K C8 1N R24 1K R26 200K R28 2.2K VR1 47K C9 8N2 C14 8N2 C15 10N R31 4.7K R66 4.7K R7722K D4 5.6V D5 5.6V 1 P20 2 P21 3 P30 4 P31 5 P32 6 P33 7 P42 8 P43 9 P51 10 P60 11 P61 12 P62 13 VSS 14 P63 15 PA0 16 PA1 17 PA2 18 PA3 19 PB0 20 PB1 21 PB2 22 PB3 23 BTG 24 DTMF 25 RESET 26 OSCO 27 OSCI 28 VDD IC6 W921E400 C17 330P C38104 R33 180K 3 + 2 - 1 IC1A KA324 5 + 6 - 7 IC1B KA324 10 + 9 - 8 IC1C KA324 12 + 13 - 14 IC1D KA324 3 + 2 - 1 IC2A KA324 12 + 13 - 14 IC2D KA324 C41 100uF C4424P R38 330K R53 330K R8033K R8233K R83 9.1K C47 102M/400V C48 102M/400V C50 0.22uF R84 10/1W C57 470uF R4 100K R32 100K R17 1.8K R18 47K C13 393 C49 473P Q4 C945G C60 100N R86 10K R87 100K 5 + 6 - 7 IC2B KA324 10 + 9 - 8 IC2C KA324 1 23 45 6 78 9 10 11 C4 470P/2KV C5 470P/2KV VR247K C71 100N R112 100K C69 100N C70 NA C68 NA C72103 D6 1N4148 C73 103 R113 47K STD CLOCK RSSI CH+ CH- CDATA l9915hmn.sch-1 - Fri Sep 22 09:08:59 2000
FCC ID: O63M42002 Inte rte k Te sting Se rvice s Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2741 1693 November 20, 2000 Lionda Technology Co., Ltd. Blk. 2, Laodong 2nd Indโl. Area, Xixian, Baoan, Shenzhen, China. Tel.:86-755-7917824 Fax.:86-755-7917944 Dear Mr. Dan Coronia: Enclosed you will find your file copy of a Part 15 Certification (FCC ID: O63M42002). We have forwarded the original to the TCB. For your reference, TCB will normally take another 15-20 days for reviewing the report. Approval will then be granted when no query is sorted. Please contact me if you have any questions regarding the enclosed material. Sincerely, Wilson Loke Manager Enclosure โข The test results rep orted in this rep ort shall refer only to the samp le actually tested and shall not refer or be deemed to refer to bulk from which such a samp le may be said to have been obtained. โข This rep ort shall not be rep roduced excep t in full without p rior authorization form Intertek Testing Services Limit ed FCC ID: O63M42002 Inte rte k Te sting Se rvice s Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2741 1693 Lionda Technology Co., Ltd. Application For Certification 900MHz 40 Channels Cordless Telephone with Caller ID (FCC ID: O63M42002) WO# 0012260 ALO/kid November 20, 2000 INTERTEK TESTING SERVICES FCC ID: O63M42002 i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1:General Description EXHIBIT 2:System Test Configuration EXHIBIT 3:Emission Results EXHIBIT 4:Equipment Photographs EXHIBIT 5:Product Labelling EXHIBIT 6:Technical Specifications EXHIBIT 7:Instruction Manual EXHIBIT 8:Security Code Information INTERTEK TESTING SERVICES FCC ID: O63M42002 ii MEASUREMENT/TECHNICAL REPORT Lionda Technology Co., Ltd. - MODEL: BellSouth MH9918 FCC ID: O63M42002 This report concerns (check one:) Original Grant X Class II Change Equipment Type : Cordless Telephone (example : computer, modem, transmitter, etc.) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?Yes No X If yes, defer until : date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37 ?Yes No X If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [ 10-1-99 Edition ] Provision. Report prepared by:Wilson Loke Intertek Testing Services. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Phone :852-2173-8575 Fax:852-2741-1693 INTERTEK TESTING SERVICES FCC ID: O63M42002 iii Table of Contents 1.0 General Description ................................................................................................................ 2 1.1 Product Description ............................................................................................................... 3 1.2 Related Submittal(s) Grants ................................................................................................... 4 1.3 Test Methodology .................................................................................................................. 4 1.4 Test Facility............................................................................................................................ 4 2.0 System Test Configuration ...................................................................................................... 6 2.1 Justification ............................................................................................................................ 6 2.2 EUT Exercising Software ....................................................................................................... 6 2.3 Support Equipment List and Description ............................................................................... 7 2.4 Equipment Modification ........................................................................................................ 8 3.0 Emission Results .................................................................................................................... 10 3.1 Field Strength Calculation .................................................................................................... 11 3.2 Radiated Emission Configuration Photograph - Base Unit .................................................. 12 3.3 Radiated Emission Data - Base Unit .................................................................................... 13 3.4 Radiated Emission Configuration Photograph - Handset..................................................... 16 3.5 Radiated Emission Data - Handset....................................................................................... 17 3.6 Radiated Emission on the bandedge .................................................................................... 20 3.7 Line Conducted Configuration Photograph - Base Unit ..................................................... 22 3.8 Line Conducted Data - Base Unit ........................................................................................ 23 4.0 Equipment Photographs ....................................................................................................... 26 5.0 Product Labelling .................................................................................................................. 28 6.0 Technical Specifications ........................................................................................................ 30 7.0 Instruction Manual ................................................................................................................ 32 8.0 Security Code Information ................................................................................................... 34 INTERTEK TESTING SERVICES FCC ID: O63M420021 List of attached file Exhibit typeFile Descriptionfilename Cover LetterLetter of Agencyletter.pdf Test ReportTest Reportreport.doc Operatโฆ
Text truncated - open the document above for the full version.
2/F., Garment Centre, ยท Kowloon ยท Hong Kong
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 926.25 MHz - 927.712 MHz | - |

Digital Cordless Phone ๏ฟฝ Handset Unit
Equipment Class
DTS - Digital Transmission System
Analog Cordless Phone
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Analog Cordless Phone
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
2.4GHz Digital Spread-Spectrum Cordless Phone
Equipment Class
DTS - Digital Transmission System
2.4GHz Digital Spread-Spectrum Cordless Phone
Equipment Class
DTS - Digital Transmission System